Device of this mark is a trademark
of Sharp Corporation.
“Plasmacluster” and “Device of a cluster of
grapes” are registered trademarks of Sharp
Corporation in Japan, USA and elsewhere.
“High-Density 7000” is a trademark of
Sharp Corporation.
OPERATION MANUAL
PEMBERSIH UDARA
dengan Fungsi Pelembapan
BUKU PANDUAN OPERASI
加湿空气净化器
使用说明书
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm
which is measured around the center of a room with
the “high-density plasmacluser 7000” applicable floor
area (at 1.2 m height above the fl oor) at the maximum
wind volume in humidifying & air purifying mode, or
in air purifying mode, when a humidifier/air purifier or
an air purifier using the high-density plasmacluster
ion evolving device is placed close to a wall.
This product is equipped with a device corresponding to
this capacity.
3
ENGLISHMALAYSIA
中文
,
Free standing type
Jenis berdiri sendiri
直立式
Please read before operating your new Air Purier
The air purier draws in room air from the air intake, passes the air through a
Pre-Filter, a Washable Deodorizing Filter and a HEPA Filter inside of the unit, then
discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust
particles as small as 0.3 microns that pass through the lter and also helps absorb
odours.
The Washable Deodorizing Filter gradually absorbs odours as they pass through the
lter.
Some odours absorbed by the lters may break down over time, resulting in additional
odour. Depending on the usage environment, especially when the product is used in
extreme environments (significantly more severe than normal household use), this
odour may become strong in a shorter period than expected. If the odour persists, the
lters should be replaced.
NOTE
• The air purier is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke). If the source of the odour still exists, the
air purier may not completely remove the odour.
HEPA Filter
Deodorizing Filter
Pre-Filter
(Common illustration has used “KC-A60E”.)
ENGLISH
FEATURES
Unique Combination of Air Treatment
Technologies
Triple Filtration System + Plasmacluster
+ Humidication
TRAPS DUST*
Washable pre-filter traps dust and other
large airborne particles.
DECREASES ODOURS
Washable deodorizing lter absorbs many
common household odours.
REDUCES POLLEN & MOLD*
HEPA filter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the
way nature cleans the environment by
emitting a balance of positive and negative
ions.
HUMIDIFIES
Runs up to 10 hours per lling.**
*When air is drawn through the filter sys-
tem.
**Room size:
up to 48 m
up to 38 m
up to 26 m2 (KC-A40E)
Sensor Technology continuously monitors
air quality, and automatically adjusting op-
eration based on detected air purity and
humidity.
Thank you for purchasing this SHARP Air
Purifier. Please read this manual carefully
before using the air purier.
After reading, keep the manual in a conven-
ient location for future reference.
E-1
E-19
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
WARNING
• Read all instructions before using the unit.
• Use only a 220~240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet
is loosened.
• Periodically remove dust from the plug.
• Do not insert ngers or foreign objects into the air intake or air outlet.
• When removing the power plug, always hold the plug and never pull on the cord.
Electrical shock and/or re from a short circuit may result.
•
Do not damage the power cord by caster when moving the main unit.
(It may cause electric shock, heat generation or re.)
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
•
When relling the Water Tank, cleaning the unit, or when the unit is not in use, be sure to unplug
the unit. Electrical shock and/or re from a short circuit may result
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a
Sharp authorized Service Centre or similarly qualied person in order to avoid a hazard.
• Only a Sharp Authorized Service Centre should service this air purier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet,
such as a bathroom.
• Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
• When carrying the unit, remove the Water Tank and Humidifying Tray rst and hold the unit by han-
dles on both sides.
• Do not drink the water in the Humidifying Tray or Water Tank.
• Change the water in the Water Tank daily with fresh tap water and regularly clean the Water Tank
and Humidifying Tray. (See E-12 and E-13). When unit is not in use, dispose of the water in the
Water Tank and Humidifying Tray. Leaving water in the Water Tank and/or Humidifying Tray may
result in mold, bacteria, and bad odours.
In rare cases, this bacteria may cause harmful physical effects.
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-
pervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
– To reduce the risk of electrical shock, re or injury to persons:
NOTE
If this air purier should cause interference to radio or television reception, try to correct the interfer-
ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation distance between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
• Consult the dealer or an experienced radio/TV technician for help.
– Radio or TV Interference
E-2
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters, or where it may come into
contact with steam.
• Always operate the unit in an upright position.
• Hold the unit by using the handles on both sides when moving.
Do not move when the unit is in operation.
• Do not move or change the direction of the main unit while dragging the casters.
• Lift it up and move such as a tatami mat, a oor which gets damaged easily, an uneven place, and
thick-poled carpet.
• When moving by the caster, move it slowly to horizontal direction.
• When moving, make sure to stop operation and remove the water tank and Humidifying Tray by
holding the side handle of the unit.
• When remove the water tank, be careful not to get your nger caught in.
• Do not operate the unit without the lters, Water Tank, and Humidifying Tray properly
installed.
• Do not wash and reuse the HEPA lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
Do not use volatile uids and/or detergents.
The unit surface may be damaged or cracked.
In addition, the sensors may malfunction as a result.
• Frequency of maintenance required (descaling) will depend on the hardness or the
impurities of
necessary.
• Keep the unit away from water.
the water that you use; the harder the water the more often descaling will be
ENGLISH
INSTALLATION GUIDELINES
• When using the unit, place at least 2m away from equipment utilizing electric waves such
as televisions or radios to avoid electrical interference.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid use in locations where furniture, fabrics or other items may come in contact with and
restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or drastic temperature
changes. Appropriate conditions are when room temperature is between 5 – 35 ºC.
• Place on a stable surface with sufcient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
Place the unit on an even surface to avoid water leakage from the Water Tank and/or Humidifying
Tray.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack or the sensor may malfunction as a result.
• Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper airow.
The wall directly behind the air outlet may become dirty over time. When using the unit for an ex
tended period of time in the same location, periodically clean the wall and protect the wall with a
vinyl sheet, etc. to prevent the wall from becoming dirty.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lters.
aCLEAN AIR MODE Button /INDICATOR LIGHT
bCLEAN AIR & HUMIDIFY MODE Button / INDICATOR LIGHT
cCLEAN ION SHOWER MODE Button / INDICATOR LIGHT
2LIGHT CONTROL Button5CHILD-LOCK Button /
3Plasmacluster Ion ON / OFF Button /
INDICATOR LIGHT
4FILTER RESET Button /
INDICATOR LIGHT
(green)
(red)
a
b
6Plasmacluster Sign
7FAN SPEED Button /
8POWER OFF Button
c
(green)
(green)
(green)
INDICATOR LIGHT
INDICATOR LIGHT
(green)
(green)
ILLSTRARATIVE DIAGRAM
Humidity Monitor
Indicates approximate humidity level
in the room.
Humidity setting cannot be adjusted.
Odour Monitor*
Indicates the odour intensity of the
room in 3 stages colours.
green
ENGLISH
red
Humidify Light
green
off
red
(Flash
ing)
Humidity ON
Humidity OFF
need to supply water
E-5
FaintStrong
* KC-A60E, KC-A50E ONLY
Dust Moniter
Indicates the air purity of the room
in 5 stages colours.
Clean
Impure
green
red
1
2
Be sure to remove the power
PREPARATION
FILTER INSTALLATION
Remove the Back Panel.
plug from the wall outlet.
1
HEPA lter (White)
Remove the Filters from the
2
Install the Filters in the correct
3
HEPA lter (White)
Deodorizing lter (Black)
plastic bag.
order as shown.
Deodorizing lter (Black)
Click
4
Fill in the usage start date on the
5
Install the Back Panel.
Date Label.
E-6
1
2
3
1
2
REFILLING THE WATER TANK
When using the Clean Air & Humidify Mode, or the Clean ION Shower Mode.
Remove the Water Tank.
1
Fill the Water Tank with tap water.
2
MAX
CAUTION
•
Check to see that there is no water leaking.
• Be sure to wipe off any excess water on
the outside of the Water Tank.
• When carrying the Water Tank, hold it
Tighten
with both hands so that the Water Tank
opening is facing up.
ENGLISH
Install the Water Tank.
3
CAUTION
• Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result.
• Do not use hot water (40 ºC), chemical agents, aromatic substances, dirty water, or other damag-
ing substances, deformation and/or malfunction may occur.
• Use only fresh tap water. Use of other water sources may promote the growth of mold, fungus and/
or bacteria.
Click
E-7
OPERATION
CLEAN AIR & HUMIDIFY
Using to quickly clean the air, reduce odours and to humidify.
START
• Select the desired fan speed.(Ref. E-9)
• Unless the power cord has been unplugged, the operations starts in the pre-
vious mode it was operated in.
NOTE
• Fill the Water Tank.(Ref. E-7)
• When the Water Tank is empty, the unit will operation “CLEAN AIR MODE”and is
ashing(red).
STOP
About Automatic Humidify Mode
The Temperature/Humidity sensors automatically detect and adjust
humidity according to changes in room temperature. Depending on
the size and humidity of the room, humidity may not reach 55~65 %.
In such cases, it is recommended that CLEAN AIR & HUMIDIFY/
MAX MODE be used.
CLEAN AIR
Using when additinal humidity is not required.
START
• Select the desired fan speed.(Ref. E-9)
• Unless the power cord has been unplugged, the operations starts in the pre-
vious mode it was operated in.
TemperatureHumidity
~18 ºC65 %
18 ºC~24 ºC60 %
24 ºC~55 %
STOP
E-8
CLEAN ION SHOWER
Releases high-density Plasmacluster ions and discharges strong air ow for 60 minutes.
START
NOTE
• If the “Plasmacluster Ion is OFF,
the plasmacluster ion will be not released.
• When the operation nishes, the unit will return to
the prior operation mode.
It is able to change the other mode and during
this mode.
FAN SPEED
Select the desired fan speed.
ENGLISH
AUTOPOLLEN
MAX
MED
LOW
NOTE
AUTO
POLLEN
The fan speed is automatically switched (between HIGH and LOW) depending
on the amount of impurities in the air. The sensors detect impurities for efcient
air purcation.
The unit will operate at High Level
for 10 minutes, then will alternate
between MEDIUM and HIGH.
10 minutes: High fan level
20 minutes: Medium fan level
20 minutes: High fan level
PLASMACLUSTER ION ON/OFF
When Plasmacluster is ON, both the Indicator Light and Plasmacluster Indicator Light turn on.
ON
OFF
E-9
USEFUL FUNCTION
LIGHT CONTROL
Use this function to select the desired brightness.
brighter
darker
turn off
CHILD LOCK
Operation of the unit display will be locked.It is the same method as starting operation.
ON
more 3 sec.
CANCELLATION
more 3 sec.
SOUND INDICATOR SETTING
The unit can be set to signal with an audible deep when the Water Tank is empty.
ON
(with the unit OFF)
more 3 sec.more 3 sec.
CANCELLATION
(with the unit OFF)
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
DUST MONITOR and ODOUR MONITOR is constantly red to reduce sensitivity, and set to “high’ if
the DUST MONITOR and ODOUR MONITOR is constantly green to increase sensitivity.
RED••••••••SET to “LOW’ GREEN•••SET to “HIGH’
1
(with the unit OFF)
more 3 sec.
2
3
CAUTION
• If the power OFF Button is not pushed within 8 seconds of adjusting sensor
sensitivity, the setting will be saved automatically.
• The sensor sensitivity setting will be saved even if the unit is unplugged.
High
Standard
Low
E-10
1
2
3
Be sure to remove the power
CARE AND MAINTENANCE
plug from the wall outlet
FILTER INDICATOR
The Indicator Light will turn on after approximately 720 hours. (30days×24hours=720)
Reminder to perform maintenance of parts below.
After performing maintenance, reset the Filter Indicator. (Ref. E-12)
more 3 sec.
CARE INDEX
.
Filter Indicator Light turn on.
•
Humidifying Filter (Ref. E-12)
Humidifying
Tray Cover
(Ref. E-13)
Water Tank (Ref. E-12)
Back Panel
(Ref. E-13)
Humidifying Tray (Ref. E-13)
Notice an unpleasant odor from the air out-
•
let.
• Filter performance appears fall and / or
odor persist.
Unit (Ref. E-14)
HEPA Filter
Cannot be care.
Deodoiziing Filter
(Ref. E-14)
ENGLISH
HUMIDIFYING DISINSTALLATION
After maintenance, replace the parts accurately.
frame colour : gray
E-11
CARE AND MAINTENANCE
WATER TANK
Rinse the inside with a small amount of water.
CAUTION
•Do not shake the Water Tank with holding the carrying handle.
NOTE
HUMIDIFYING FILTER
Rinse with plenty of water.
CAUTION
• Do not remove the Humidifying Filter from a lter frame.
• Avoid spilling water from the Humidifying Tray.
NOTE
1.
Soak in water with the descaling solution about 30minutes.
for Stubborn dirt...
Tank Cap
Tooth Brushs
for Stubborn dirt...
Clean inside of the water tank
with a soft sponge and the
tank cap with a cotton swab or
a toothbrush.
CAUTION
2.
Remove the descaling solution with plenty of water.
Descaling solution
• Citric acid (available at some drugstores)
• 100% bottled lemon juice with no pulp.
<For using citric acid>
2 1/2 cups of water
<For using lemon juice>
3 cups of water
When using lemon juice, soak time more longer.
stir well!
3 teaspoons
stir well!
1/4 cup
E-12
Be sure to remove the power
plug from the wall outlet.
HUMIDIFYING TRAY AND COVER
1. Remove the Humidifying Tray Cover.
2. Rinse the inside of the Humidifying Tray and the
Humidifying Tray Cover
Humidifying Tray Cover with a toothbrush.
CAUTION
• Do not remove the Float and the Roller.
• If the Float and / or the Roller comes off. (Ref. E-17)
Float
Roller
NOTE
TRAY
COVER
for Stubborn dirt...
1.
2.
3.
4.
1.
2.
Clean difcult to Reach parts
Fill the tray half way with water.
Add a small amount of kitchen
detergent.
Sork for 30 minutes.
Remove the kitchen detergent
with clean water.
Soak in water with a small
amount of kitchen detergent
about 30 minutes.
Remove the kitchen detergent
with clean water.
with a cotton swab or toothbrush.
CAUTION
DO NOT use the detergents
shown on E-14.
If cause deformation, tarnishing,
cracking (water leakage)
ENGLISH
BACK PANEL
Back Panel
Gently remove dust with a vacuum cleaner
attachment or similar tool.
NOTE
for Stubborn dirt...
1.
2.
3.
Soak in water with kitchen deter-
gent about 10 minutes.
CAUTION
DO NOT scrub the back panel
hard.
Remove the kitchen detergent
with clean water.
Dry lter completely in a well ven-
tilated area.
E-13
CARE AND MAINTENANCECARE AND MAINTENANCE
DEODORIZIING FILTER
1
2
3
HAND WASH ONLY!
DO NOT DRY IN CLOTHES DRYER!
Remove the dust on the DEODORIZING FILTER.
Rinse the DEODORIZING FILTER with water.
CAUTION
• When washing the lter for the rst time, the rinse water may
be brown.
This does not affect deodorization performance.
• Avoid bending or folding the lter when washing.
Remove as much of the moisture as possible.
4
When possible , dry outdoors.
UNIT
Dry lter completely in a well ventilated area.
(about 6 hours to dry out)
CAUTION
• Avoid drying lter outdoors during inclement weather (e.g.
rain or cold temperatures).
• Do not allow lter to freeze.
•
If lter is dri
els, etc under the lter to prevent water damage to the oor.
Wipe with a dry, soft cloth.
CAUTION
Do not use volatile uids
•
Benzene paint thinner, polish powder, may damage the
surface.
Do not use detergents
•
Detergent ingredients may damage the unit.
e
d indoors, take precautions, such as placing tow-
E-14
FILTER REPLACEMENT
Replacement timing
Filter life will vary depending on the room environment, usage, and location of the unit. If dust or
odour persists, replace the lter.
(Refer to “Please read before operating your new Air Purier”)
The following lter life and replacement period is based on the condition of smoking 5 cigarettes per
day and the dust collection/deodorization power is reduced by half compared with that of new lter.
We recommend to replace the lter more frequently if the product is used in a condition signicantly
severer than normal household use.
•HEPA lter About 10 years after opening
•Deodorizing lter* About 10 years after opening
•Humidifying lter About 10 years after opening
*Washable deodorizing filter can be repeatedly used after washing,
or it can be replaced
.
Replacement Filter Model
Please consult your dealer for purchase of replacement lter.
REPLACEMENT FILTER MODEL
AIR PURIFIER MODEL
KC-A40FZ-A40HFEFZ-A40DFE
KC-A60FZ-A60HFEFZ-A60DFE
NOTE
HEPA Filter :
1 unit
Use the date label as a reminder for next replacement.
Deodorizing
Filter : 1 unit
Humidifying
Filter : 1unit
FZ-A60MFEKC-A50FZ-A50HFEFZ-A50DFE
Disposal of Filters
Please dispose of used filters according to any local laws and
regulations.
HEPA Filter material :
• Filter : Polypropylene
• Frame: Polyester
ENGLISH
Humidifying Filter
Filter Frame (white)
Filter Frame (gray)
Deodorizing Filter material :
• Deodorizer : Activates charcoal
• Filter : Polyester, Rayon
Humidifying Filter material :
• Filter : Rayon, Polyester
HEPA lter
Deodorizing lter
E-15
TROUBLESHOOTING
Before calling for service, please review the Troubleshooting chart below, since the problem may not
be a unit malfunction.
SYMPTOMREMEDY (not a malfunction)
Odours and smoke are not removed.
The Front Monitor illuminates
green even when the air is impure.
The Front Monitor illuminates
orange or red even when the air
is clean.
A clicking or ticking sound is
heard from the unit.
The discharged air has an
odour.
The unit does not operate when
cigarette smoke is in the air.
• Clean or replace the lters if they appear to be heavily soiled.
(Ref. E-11,E-12,E-14)
• The air could be impure at the time the unit was plugged in.
Unplug the unit, wait one minute, and plug the unit in again.
• Sensor operation is affected if the dust sensor openings are
dirty or clogged. Gently clean the dust sensors. (Ref. E-11).
• Clicking or ticking sounds may be audible when the unit is gen-
erating ions.
• Check to see if the lters are heavily soiled.
• Clean or replace the lters.
• Plasmacluster Air Puriers emit small traces of ozone which
may produce an odour.
• Is the unit installed in a location that is difcult for the sensor to
detect cigarette smoke?
• Are the dust sensor openings blocked or clogged?
(In this case, clean the openings.) (Ref. E-11)
Filter Indicator Light is illuminated.
The Front Monitor are turned
off.
The Water Supply Indicator
Light does not illuminate when
the tank is empty.
Water lever in the tank does not
decrease or decreases slowly.
The Front Monitor lights change
colour frequently.
• After replacing lters, connect the power cord to an outlet and
press the Filter Reset Button. (Ref. E-11)
• Check to see if the Lights OFF Mode selected. If so, then press
the Lights Control Button to activate the indicator lights.
(Ref. E-10)
• Check Styrofoam oat for impurities. Clean the HumidifyingTray.
Ensure unit is located on a level surface.
• Check to see if the Humidifying Tray and Water Tank are cor-
rectly installed. Check the Humidifying Filter.
• Clean or replace the lter when it is heavily soiled.
(Ref. E-14 and E-15).
• The Front Monitor lights automatically change colours as impuri-
ties are detected by the dust sensor and odour sensor.
E-16
SYMPTOMREMEDY (not a malfunction)
When the Roller / Float was removed.
FLOAT
1. Insert the oat under
this tab.
2. Inner the tab
of oat into
the hole.
3. Insert the tab on the other
side of the oat into the
hole.
AUTO RESTART
Cross-Section view
Tab
• Install the Roller / Float in order below.
ROLLER
Fix the roller in the tray from side way.
Float
Float
NOTE
Check the direction
of the roller.
ENGLISH
After a power failure, automatically resume
the operation when the power recovers.
ON
(with the unit OFF)
(simultaneously for more 3 sec.)
If the , , lamp lights up
for 10 seconds, the setting is
complete.
Auto Restart can be set.
• Even when the plug is unplugged or the breaker
is thrown during the operation, the operation
resumes at the previous operation mode and
settings if the power recovers.
CANCELLATION
(with the unit OFF)
(simultaneously for more 3 sec.)
E-17