approximate number of ions supplied into air of 1 cm which is measured around the center of a room with the “high-density plasmacluser 7000” applicable floor area (at 1.2 m height above the fl oor) at the maximum wind volume in humidifying & air purifying mode, or in air purifying mode, when a humidifier/air purifier or an air purifier using the high-density plasmacluster ion evolving device is placed close to a wall. This product is equipped with a device corresponding to this capacity.
3
ENGLISHMALAYSIA
中文
,
Free standing type
Jenis berdiri sendiri
直立式
Please read before operating your new Air Purier
The air purier draws in room air from the air intake, passes the air through a Pre-Filter, a Washable Deodorizing Filter and a HEPA Filter inside of the unit, then
discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the lter and also helps absorb
odours.
The Washable Deodorizing Filter gradually absorbs odours as they pass through the lter.
Some odours absorbed by the lters may break down over time, resulting in additional odour. Depending on the usage environment, especially when the product is used in extreme environments (significantly more severe than normal household use), this odour may become strong in a shorter period than expected. If the odour persists, the
lters should be replaced.
NOTE
• The air purier is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke). If the source of the odour still exists, the air purier may not completely remove the odour.
HEPA Filter
Deodorizing Filter
Pre-Filter
(Common illustration has used “KC-A60E”.)
ENGLISH
FEATURES
Unique Combination of Air Treatment Technologies Triple Filtration System + Plasmacluster
+ Humidication
TRAPS DUST*
Washable pre-filter traps dust and other large airborne particles.
DECREASES ODOURS
Washable deodorizing lter absorbs many
common household odours.
REDUCES POLLEN & MOLD*
HEPA filter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the
way nature cleans the environment by emitting a balance of positive and negative
ions.
HUMIDIFIES
Runs up to 10 hours per lling.**
*When air is drawn through the filter sys-
tem.
**Room size:
up to 48 m up to 38 m
up to 26 m2 (KC-A40E)
Sensor Technology continuously monitors
air quality, and automatically adjusting op-
eration based on detected air purity and humidity.
2
(KC-A60E)
2
(KC-A50E)
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
• WARNING
• CAUTIONS CONCERNING OPERATION
• INSTALLATION GUIDELINES
• FILTER GUIDELINES
PART NAMES
• FRONT / BACK
• MAIN UNIT DISPLAY
• ILLUSTRATIVE DIAGRAM
PREPARATION .............................................
• FILTER INSTALLATION
• REFILLING THE WATER TANK
OPERATION
• CLEAN AIR & HUMIDIFY
• CLEAN AIR
• CLEAN ION SHOWER
• FAN SPEED
• PLASMACLUSTER ION ON/OFF
USEFUL FUNCTION
• LIGHTS CONTROL
• CHILD LOCK
• SOUND INDICATOR SETTING
• ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
CARE AND MAINTENANCE
• FILTER INDICATOR
• CARE INDEX
• HUMIDIFYING DISINSTALLATION
• WATER TANK
• HUMIDIFYING FILTER
• HUMIDIFYING TRAY AND COVER
• BACK PANEL
• DEODORIZING FILTER
• UNIT
• FILTER REPLACEMENT
TROUBLESHOOTING
.............................................
...............................................
...............................
.................
............................
...
E-2
E-4
E-6
ENGLISH
E-8
E-10
E-11
E-16
SPECIFICATIONS
....................................
Thank you for purchasing this SHARP Air Purifier. Please read this manual carefully before using the air purier.
After reading, keep the manual in a conven-
ient location for future reference.
E-1
E-19
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING
Read all instructions before using the unit.
Use only a 220~240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened.
• Periodically remove dust from the plug.
• Do not insert ngers or foreign objects into the air intake or air outlet.
• When removing the power plug, always hold the plug and never pull on the cord.
Electrical shock and/or re from a short circuit may result.
Do not damage the power cord by caster when moving the main unit.
(It may cause electric shock, heat generation or re.)
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
When relling the Water Tank, cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electrical shock and/or re from a short circuit may result
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a
Sharp authorized Service Centre or similarly qualied person in order to avoid a hazard.
Only a Sharp Authorized Service Centre should service this air purier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as a bathroom.
Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
When carrying the unit, remove the Water Tank and Humidifying Tray rst and hold the unit by han-
dles on both sides.
Do not drink the water in the Humidifying Tray or Water Tank.
Change the water in the Water Tank daily with fresh tap water and regularly clean the Water Tank
and Humidifying Tray. (See E-12 and E-13). When unit is not in use, dispose of the water in the Water Tank and Humidifying Tray. Leaving water in the Water Tank and/or Humidifying Tray may result in mold, bacteria, and bad odours.
In rare cases, this bacteria may cause harmful physical effects.
This appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-
pervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
– To reduce the risk of electrical shock, re or injury to persons:
NOTE
If this air purier should cause interference to radio or television reception, try to correct the interfer-
ence by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation distance between the unit and radio/TV receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
Consult the dealer or an experienced radio/TV technician for help.
– Radio or TV Interference
E-2
CAUTIONS CONCERNING OPERATION
Do not block the intake and/or air outlet.
Do not use the unit near or on hot objects, such as stoves or heaters, or where it may come into
contact with steam.
Always operate the unit in an upright position.
• Hold the unit by using the handles on both sides when moving. Do not move when the unit is in operation.
Do not move or change the direction of the main unit while dragging the casters.
Lift it up and move such as a tatami mat, a oor which gets damaged easily, an uneven place, and
thick-poled carpet.
When moving by the caster, move it slowly to horizontal direction.
When moving, make sure to stop operation and remove the water tank and Humidifying Tray by
holding the side handle of the unit.
When remove the water tank, be careful not to get your nger caught in.
• Do not operate the unit without the lters, Water Tank, and Humidifying Tray properly
installed.
• Do not wash and reuse the HEPA lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
Do not use volatile uids and/or detergents. The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result.
• Frequency of maintenance required (descaling) will depend on the hardness or the impurities of
necessary.
• Keep the unit away from water.
the water that you use; the harder the water the more often descaling will be
ENGLISH
INSTALLATION GUIDELINES
• When using the unit, place at least 2m away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid use in locations where furniture, fabrics or other items may come in contact with and
restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate conditions are when room temperature is between 5 – 35 ºC.
• Place on a stable surface with sufcient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly. Place the unit on an even surface to avoid water leakage from the Water Tank and/or Humidifying
Tray.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack or the sensor may malfunction as a result.
• Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper airow.
The wall directly behind the air outlet may become dirty over time. When using the unit for an ex
tended period of time in the same location, periodically clean the wall and protect the wall with a vinyl sheet, etc. to prevent the wall from becoming dirty.
FILTER GUIDELINES
Follow the instructions in this manual for correct care and maintenance of the lters.
-
E-3
PART NAMES
FRONT / BACK
1 2
3
1 Main Unit Display
2
Front Monitor
3
Main Unit
(Ref.E-5)
1
2
3 4
5
6 7
8
1 Air Outlet 6 Float 2 Handle 3 Sensor
•Dust Senser
•Temperture / Humidity Senser
•Odour Senser (KC-A60E•KC-A50E ONLY)
4 Water Tank
5 Humidifying Filter
(2 Locations)
(Internal)
7 Humidifying Tray 8 Caster
9 HEPA Filter 10 Deodorizing Filter 11 Back Panel 12 Air Inlet
13 Power Cord / Plug
9
10
11 12
13
(Shape of plug depends on country.)
(4 Locations)
(white)
(black)
(Pre-Filter)
INCLUDED
• Operation manual
• Slipper
×4
E-4
MAIN UNIT DISPLAY
2
3
1
6 7 8
5
4
1 POWER ON Button
a CLEAN AIR MODE Button /INDICATOR LIGHT b CLEAN AIR & HUMIDIFY MODE Button / INDICATOR LIGHT c CLEAN ION SHOWER MODE Button / INDICATOR LIGHT
2 LIGHT CONTROL Button 5 CHILD-LOCK Button /
3 Plasmacluster Ion ON / OFF Button /
INDICATOR LIGHT
4 FILTER RESET Button /
INDICATOR LIGHT
(green)
(red)
a
b
6 Plasmacluster Sign
7 FAN SPEED Button /
8 POWER OFF Button
c
(green)
(green)
(green)
INDICATOR LIGHT
INDICATOR LIGHT
(green)
(green)
ILLSTRARATIVE DIAGRAM
Humidity Monitor
Indicates approximate humidity level
in the room.
Humidity setting cannot be adjusted.
Odour Monitor*
Indicates the odour intensity of the
room in 3 stages colours.
green
ENGLISH
red
Humidify Light
green
off red
(Flash
ing)
Humidity ON
Humidity OFF
need to supply water
E-5
Faint Strong
* KC-A60E, KC-A50E ONLY
Dust Moniter
Indicates the air purity of the room in 5 stages colours.
Clean
Impure
green
red
1
2
Be sure to remove the power
PREPARATION
FILTER INSTALLATION
Remove the Back Panel.
plug from the wall outlet.
1
HEPA lter (White)
Remove the Filters from the
2
Install the Filters in the correct
3
HEPA lter (White)
Deodorizing lter (Black)
plastic bag.
order as shown.
Deodorizing lter (Black)
Click
4
Fill in the usage start date on the
5
Install the Back Panel.
Date Label.
E-6
1
2
3
1
2
REFILLING THE WATER TANK
When using the Clean Air & Humidify Mode, or the Clean ION Shower Mode.
Remove the Water Tank.
1
Fill the Water Tank with tap water.
2
MAX
CAUTION
Check to see that there is no water leaking.
• Be sure to wipe off any excess water on the outside of the Water Tank.
• When carrying the Water Tank, hold it
Tighten
with both hands so that the Water Tank
opening is facing up.
ENGLISH
Install the Water Tank.
3
CAUTION
• Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result.
• Do not use hot water (40 ºC), chemical agents, aromatic substances, dirty water, or other damag-
ing substances, deformation and/or malfunction may occur.
• Use only fresh tap water. Use of other water sources may promote the growth of mold, fungus and/ or bacteria.
Click
E-7
OPERATION
CLEAN AIR & HUMIDIFY
Using to quickly clean the air, reduce odours and to humidify.
START
• Select the desired fan speed.(Ref. E-9)
• Unless the power cord has been un­plugged, the operations starts in the pre-
vious mode it was operated in.
NOTE
• Fill the Water Tank.(Ref. E-7)
• When the Water Tank is empty, the unit will operation “CLEAN AIR MODE”and is
ashing(red).
STOP
About Automatic Humidify Mode
The Temperature/Humidity sensors automatically detect and adjust humidity according to changes in room temperature. Depending on the size and humidity of the room, humidity may not reach 55~65 %. In such cases, it is recommended that CLEAN AIR & HUMIDIFY/ MAX MODE be used.
CLEAN AIR
Using when additinal humidity is not required.
START
• Select the desired fan speed.(Ref. E-9)
• Unless the power cord has been un­plugged, the operations starts in the pre-
vious mode it was operated in.
Temperature Humidity
~18 ºC 65 %
18 ºC~24 ºC 60 %
24 ºC~ 55 %
STOP
E-8
CLEAN ION SHOWER
Releases high-density Plasmacluster ions and discharges strong air ow for 60 minutes.
START
NOTE
• If the “Plasmacluster Ion is OFF,
the plasmacluster ion will be not released.
• When the operation nishes, the unit will return to
the prior operation mode.
It is able to change the other mode and during
this mode.
FAN SPEED
Select the desired fan speed.
ENGLISH
AUTO POLLEN
MAX
MED
LOW
NOTE
AUTO
POLLEN
The fan speed is automatically switched (between HIGH and LOW) depending on the amount of impurities in the air. The sensors detect impurities for efcient air purcation.
The unit will operate at High Level for 10 minutes, then will alternate between MEDIUM and HIGH.
10 minutes: High fan level 20 minutes: Medium fan level 20 minutes: High fan level
PLASMACLUSTER ION ON/OFF
When Plasmacluster is ON, both the Indicator Light and Plasmacluster Indicator Light turn on.
ON
OFF
E-9
USEFUL FUNCTION
LIGHT CONTROL
Use this function to select the desired brightness.
brighter
darker
turn off
CHILD LOCK
Operation of the unit display will be locked.It is the same method as starting operation.
ON
more 3 sec.
CANCELLATION
more 3 sec.
SOUND INDICATOR SETTING
The unit can be set to signal with an audible deep when the Water Tank is empty.
ON
(with the unit OFF)
more 3 sec. more 3 sec.
CANCELLATION
(with the unit OFF)
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
DUST MONITOR and ODOUR MONITOR is constantly red to reduce sensitivity, and set to “high’ if the DUST MONITOR and ODOUR MONITOR is constantly green to increase sensitivity. RED••••••••SET to “LOW’ GREEN•••SET to “HIGH’
1
(with the unit OFF)
more 3 sec.
2 3
CAUTION
• If the power OFF Button is not pushed within 8 seconds of adjusting sensor sensitivity, the setting will be saved automatically.
• The sensor sensitivity setting will be saved even if the unit is unplugged.
High Standard
Low
E-10
1
2
3
Be sure to remove the power
CARE AND MAINTENANCE
plug from the wall outlet
FILTER INDICATOR
The Indicator Light will turn on after approximately 720 hours. (30days×24hours=720)
Reminder to perform maintenance of parts below. After performing maintenance, reset the Filter Indicator. (Ref. E-12)
more 3 sec.
CARE INDEX
.
Filter Indicator Light turn on.
Humidifying Filter (Ref. E-12)
Humidifying Tray Cover (Ref. E-13)
Water Tank (Ref. E-12)
Back Panel (Ref. E-13)
Humidifying Tray (Ref. E-13)
Notice an unpleasant odor from the air out-
let.
• Filter performance appears fall and / or
odor persist.
Unit (Ref. E-14)
HEPA Filter Cannot be care.
Deodoiziing Filter (Ref. E-14)
ENGLISH
HUMIDIFYING DISINSTALLATION
After maintenance, replace the parts accurately.
frame colour : gray
E-11
CARE AND MAINTENANCE
WATER TANK
Rinse the inside with a small amount of water.
CAUTION
Do not shake the Water Tank with holding the carrying handle.
NOTE
HUMIDIFYING FILTER
Rinse with plenty of water.
CAUTION
• Do not remove the Humidifying Filter from a lter frame.
• Avoid spilling water from the Humidifying Tray.
NOTE
1.
Soak in water with the descaling solution about 30minutes.
for Stubborn dirt...
Tank Cap
Tooth Brushs
for Stubborn dirt...
Clean inside of the water tank with a soft sponge and the tank cap with a cotton swab or a toothbrush.
CAUTION
2.
Remove the descaling solution with plenty of water.
Descaling solution
• Citric acid (available at some drugstores)
• 100% bottled lemon juice with no pulp.
<For using citric acid>
2 1/2 cups of water
<For using lemon juice>
3 cups of water
When using lemon juice, soak time more longer.
stir well!
3 teaspoons
stir well!
1/4 cup
E-12
Be sure to remove the power plug from the wall outlet.
HUMIDIFYING TRAY AND COVER
1. Remove the Humidifying Tray Cover.
2. Rinse the inside of the Humidifying Tray and the
Humidifying Tray Cover
Humidifying Tray Cover with a toothbrush.
CAUTION
• Do not remove the Float and the Roller.
• If the Float and / or the Roller comes off. (Ref. E-17)
Float
Roller
NOTE
TRAY
COVER
for Stubborn dirt...
1.
2.
3.
4.
1.
2.
Clean difcult to Reach parts
Fill the tray half way with water. Add a small amount of kitchen
detergent.
Sork for 30 minutes.
Remove the kitchen detergent
with clean water.
Soak in water with a small
amount of kitchen detergent
about 30 minutes.
Remove the kitchen detergent
with clean water.
with a cotton swab or toothbrush.
CAUTION
DO NOT use the detergents shown on E-14.
If cause deformation, tarnishing, cracking (water leakage)
ENGLISH
BACK PANEL
Back Panel
Gently remove dust with a vacuum cleaner attachment or similar tool.
NOTE
for Stubborn dirt...
1.
2.
3.
Soak in water with kitchen deter-
gent about 10 minutes.
CAUTION
DO NOT scrub the back panel
hard.
Remove the kitchen detergent
with clean water.
Dry lter completely in a well ven-
tilated area.
E-13
CARE AND MAINTENANCECARE AND MAINTENANCE
DEODORIZIING FILTER
1
2
3
HAND WASH ONLY! DO NOT DRY IN CLOTHES DRYER!
Remove the dust on the DEODORIZING FILTER.
Rinse the DEODORIZING FILTER with water.
CAUTION
• When washing the lter for the rst time, the rinse water may be brown.
This does not affect deodorization performance.
• Avoid bending or folding the lter when washing.
Remove as much of the moisture as possible.
4
When possible , dry outdoors.
UNIT
Dry lter completely in a well ventilated area.
(about 6 hours to dry out)
CAUTION
• Avoid drying lter outdoors during inclement weather (e.g. rain or cold temperatures).
• Do not allow lter to freeze.
If lter is dri els, etc under the lter to prevent water damage to the oor.
Wipe with a dry, soft cloth.
CAUTION
Do not use volatile uids
Benzene paint thinner, polish powder, may damage the
surface.
Do not use detergents
Detergent ingredients may damage the unit.
e
d indoors, take precautions, such as placing tow-
E-14
FILTER REPLACEMENT
Replacement timing
Filter life will vary depending on the room environment, usage, and location of the unit. If dust or odour persists, replace the lter. (Refer to “Please read before operating your new Air Purier”) The following lter life and replacement period is based on the condition of smoking 5 cigarettes per day and the dust collection/deodorization power is reduced by half compared with that of new lter. We recommend to replace the lter more frequently if the product is used in a condition signicantly
severer than normal household use.
•HEPA lter About 10 years after opening
•Deodorizing lter* About 10 years after opening
•Humidifying lter About 10 years after opening
*Washable deodorizing filter can be repeatedly used after washing,
or it can be replaced
.
Replacement Filter Model
Please consult your dealer for purchase of replacement lter.
REPLACEMENT FILTER MODEL
AIR PURIFIER MODEL
KC-A40 FZ-A40HFE FZ-A40DFE
KC-A60 FZ-A60HFE FZ-A60DFE
NOTE
HEPA Filter :
1 unit
Use the date label as a reminder for next replacement.
Deodorizing
Filter : 1 unit
Humidifying Filter : 1unit
FZ-A60MFEKC-A50 FZ-A50HFE FZ-A50DFE
Disposal of Filters
Please dispose of used filters according to any local laws and
regulations.
HEPA Filter material :
• Filter : Polypropylene
• Frame: Polyester
ENGLISH
Humidifying Filter
Filter Frame (white)
Filter Frame (gray)
Deodorizing Filter material :
• Deodorizer : Activates charcoal
• Filter : Polyester, Rayon
Humidifying Filter material :
• Filter : Rayon, Polyester
HEPA lter
Deodorizing lter
E-15
TROUBLESHOOTING
Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction.
SYMPTOM REMEDY (not a malfunction)
Odours and smoke are not re­moved.
The Front Monitor illuminates green even when the air is im­pure.
The Front Monitor illuminates orange or red even when the air is clean.
A clicking or ticking sound is
heard from the unit.
The discharged air has an odour.
The unit does not operate when
cigarette smoke is in the air.
• Clean or replace the lters if they appear to be heavily soiled. (Ref. E-11,E-12,E-14)
• The air could be impure at the time the unit was plugged in.
Unplug the unit, wait one minute, and plug the unit in again.
• Sensor operation is affected if the dust sensor openings are
dirty or clogged. Gently clean the dust sensors. (Ref. E-11).
• Clicking or ticking sounds may be audible when the unit is gen-
erating ions.
• Check to see if the lters are heavily soiled.
• Clean or replace the lters.
• Plasmacluster Air Puriers emit small traces of ozone which
may produce an odour.
• Is the unit installed in a location that is difcult for the sensor to
detect cigarette smoke?
• Are the dust sensor openings blocked or clogged? (In this case, clean the openings.) (Ref. E-11)
Filter Indicator Light is illumi­nated.
The Front Monitor are turned off.
The Water Supply Indicator Light does not illuminate when
the tank is empty.
Water lever in the tank does not
decrease or decreases slowly.
The Front Monitor lights change colour frequently.
• After replacing lters, connect the power cord to an outlet and
press the Filter Reset Button. (Ref. E-11)
• Check to see if the Lights OFF Mode selected. If so, then press
the Lights Control Button to activate the indicator lights.
(Ref. E-10)
• Check Styrofoam oat for impurities. Clean the HumidifyingTray.
Ensure unit is located on a level surface.
• Check to see if the Humidifying Tray and Water Tank are cor-
rectly installed. Check the Humidifying Filter.
• Clean or replace the lter when it is heavily soiled. (Ref. E-14 and E-15).
• The Front Monitor lights automatically change colours as impuri-
ties are detected by the dust sensor and odour sensor.
E-16
SYMPTOM REMEDY (not a malfunction)
When the Roller / Float was removed.
FLOAT
1. Insert the oat under
this tab.
2. Inner the tab
of oat into
the hole.
3. Insert the tab on the other
side of the oat into the
hole.
AUTO RESTART
Cross-Section view
Tab
• Install the Roller / Float in order below.
ROLLER
Fix the roller in the tray from side way.
Float
Float
NOTE
Check the direction of the roller.
ENGLISH
After a power failure, automatically resume the operation when the power recovers.
ON
(with the unit OFF)
(simultaneously for more 3 sec.)
If the , , lamp lights up
for 10 seconds, the setting is
complete.
Auto Restart can be set.
• Even when the plug is unplugged or the breaker is thrown during the operation, the operation
resumes at the previous operation mode and
settings if the power recovers.
CANCELLATION
(with the unit OFF)
(simultaneously for more 3 sec.)
E-17
Loading...
+ 43 hidden pages