Please read before operating your new Air Purifi er
Some odour ingredients absorbed by the fi lter may become separated and
may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in
a condition signifi cantly more severe than household use, this odour may
become strong in a shorter period than expected.
In this case we recommend purchasing the optional replacement fi lter.
NOTE
• The air purifi er is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke.) If the odour sources still exist, it cannot
completely remove the odour(for example, odours from construction materials and pet odours).
• It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
Dust Collection / Deodorizing Filter
Elements removed by filter
Dust
pollen, dust, particles of
cigarette smoke, pet dander
Plasmacluster technology uses plasma discharge to produce and release
the same positive and negative ions
as those found in nature ("Plasmacluster ions").
This is a unique air cleaning technology of the SHARP CORPORATION
for breaking down and inactivating
such potential allergens as the feacal
matter or corpses of aerial mites*
viruses *
2
and mold and bacteria *3
1
suspended in the air, and has been
substantiated by third-party organizations both in Japan and overseas.
When there is a high density of Plasmacluster ions in the air, the smell of
cigarette smoke trapped in curtains
or sofas is removed in about 80 min-
4
, and when clothing is hung in
utes*
a place exposed to the direct air expelled from the unit generating Plasmacluster ions, the smell of sweat is
reduced to a virtually imperceptible
level in one night (about 6 hours).
*1 Graduate School of Advanced Sci-
ences of Matter, Hiroshima University,
Japan
Measurement of action on the poten-
tial allergens of aerial mites in (13m²)
*2 Retroscreen Virology, Ltd., London, UK
Measurement of ratio of viruses elimi-
nated from the air in a 1m³ box
*3 Ishikawa Health Service Association,
Japan
Measurement of aerial mold and bac-
teria with an air sampler (13m²)
*4 Japan Spinners Inspecting Foundation,
Thank you for purchasing the SHARP Air Purifi er. Please read this manual carefully for the
correct usage information. Before using this
product, be sure to read the section: “Important
Safety Instructions.”
After reading this manual, retain it in a convenient location for future reference.
.....
E-2
E-2
E-3
E-3
E-3
E-4
E-4
E-4
E-5
E-5
E-6
E-6
E-7
E-8
E-8
E-9
E-9
E-9
E-10
E-10
E-11
E-12
E-13
E-14
E-15
ENGLISH
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
WARNING
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet
is loosened.
• Periodically remove dust from the power plug.
• Do not insert fi ngers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fi re from short circuit may occur as a result.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or fi replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not using the
unit.
Electrical shock from bad insulation and/or fi re from short circuit may occur as a result.
• When refi lling the Water Tank, cleaning the unit, or when the unit is not in use, be sure to
unplug the unit. Electrical shock and/or fi re from a short circuit may result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp Authorised Service Centre or similarly qualifi ed person in order to avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air or in very high humidity conditions, such as a
bathroom.
• Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
• Only Sharp Authorised Service Centre should service this air purifi er. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
• When carrying the unit, remove the Water Tank and Humidifying Tray fi rst and hold the unit by han-
dles on both sides.
• Do not drink the water in the Humidifying Tray or Water Tank.
• Change the water in the Water Tank daily with fresh tap water and regularly clean the Water Tank
and Humidifying Tray. (See E-11 and E-12). When unit is not in use, dispose of the water in the
Water Tank and Humidifying Tray. Leaving water in the Water Tank and/or Humidifying Tray may
result in mold, bacteria, and bad odours.
In rare cases, this bacteria may cause harmful physical effects.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
- To reduce the risk of electrical shock, fi re or injury to persons:
NOTE
If this air purifi er should cause interference to radio or television reception, try to correct the interfer-
ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
- Radio or TV Interference
E-2
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Always operate the unit in an upright position.
• Always hold the handle on both sides of the unit when moving it.
Holding the back panel when carrying may cause it to detach, thus dropping the unit and resulting
in bodily injury.
• Do not operate the unit without the fi lters, Water Tank, and Humidifying Tray properly in-
stalled.
• Do not wash and reuse the fi lter .
Not only does it not improve fi lter performance, it may cause electrical shock or malfunction.
• Clean the exterior with a soft cloth only.
Do not use volatile fl uids and/or detergents.
The unit surface may be damaged or cracked.
In addition, the sensors may malfunction as a result.
INSTALLATION GUIDELINES
• During the operation of the product, please place the unit at least 2 m away from equipment
utilizing electrical waves such as televisions, radios or wave clocks.
• Avoid use in locations where furniture, fabrics or other items may come in contact with and
restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or rapid temperature
changes. (Use under appropriate conditions between 0 and 35˚C in the room.)
(If it is unavoidable please allow unit to stand for 1 hour before switching on.)
• Place on a stable surface with suffi cient air circulation.
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
• Avoid use in locations where grease or oily smoke is generated (such as in a kitchen, etc.).
The unit surface may crack or the sensor may malfunction as a result.
• Place the unit about 30 cm~60 cm(1~2 ft) away from the wall in order to ensure proper airfl ow.
The wall directly behind the air outlet may become dirty over time. When using the unit for an extended period of time in the same location, periodically clean the wall and protect the wall with a
vinyl sheet, etc. to prevent the wall from becoming dirty.
ENGLISH
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the fi lters.
Use only fi lters designed for this product.
E-3
PART NAMES
MAIN UNIT DISPLAY
Plasmacluster Ion ON/OFF Button
POWER ON/OFF Button
MODE Button
Humidify Mode
Indicator Light
Filter Reset Button
Filter Indicator Light
ILLUSTRATIVE DIAGRAM
Odour
Sensor
Fan Speed
Indicator Lights
CLEAN SIGN
The odour sensor continuosly monitors
the air and changes colour depending
on air punity.
Plasmacluster
Ion ON/OFF
Indicator Light
Green OrangeRed
CleanVery Impure
Main Unit Display
Handle
E-4
Main Unit
Loading...
+ 13 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.