Sharp KC-860E User Manual [en, ru, de, es, fr, it, cs]

KC-840E KC-850E KC-860E
R
* Plasmacluster is a
trademark of Sharp Corporation.
AIR PURIFIER with Humidifying Function OPERATION MANUAL
LUFTREINIGER mit Befeuchtungsfunktion BEDIENUNGSANLEITUNG
Purifi cateur d’air avec fonction d’humidifi cation MANUEL D’UTILISATION
LUCHTREINIGER met luchtbevochtiger GEBRUIKSAANWIJZING
PURIFICATORE D’ARIA con funzione di umidifi cazione
MANUALE D’USO
GER ENG
FRE
DUTITASPA
KC-840E
KC-850E
KC-860E
Free standing type Freistehendes Modell Type mobile Vrijstaand type Modello strutturalmente indipendente Tipo vertical sin soporte Тип установки: отдельностоящий Volně stojící Voľne stojaca Különálló típus Вільностоячий тип
床置き・卓上兼用型
PURIFICADOR DE AIRE con Función de humidifi cación MANUAL DE USO
Воздухоочиститель с функцией увлажнения РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ČISTIČKA VZDUCHU
ČISTIČKA VZDUCHU s funkciou zvlhčovania NÁVOD NA POUŽITIE
LÉGTISZTÍTÓ párásító funkcióval HASZNÁLATI ÚTMUTATÓ
ОЧИСНИК ПОВІТРЯ з Функцією Зволожування ПОСІБНИК З ЕКСПЛУАТАЦІЇ
RUS
SLK
HUN CZE
UKR
SHARP CORPORATION
OSAKA, JAPAN
加湿空気清浄機 取扱説明書
Printed in China TINS-A460KKRZ 10L-
JPN
CN 1
Please read before operating your new Air Purifi er
The air purifi er draws in room air from the air intake, passes the air through a Pre-Fil- ter, a Washable Deodorizing Filter and a HEPA Filter inside of the unit, then discharg­es the air through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the fi lter and also helps absorb odours. The Washable Deodorizing Filter gradually absorbs odours as they pass through the fi lter.
Some odours absorbed by the fi lters may break down over time, resulting in additional odour. Depending on the usage environment, especially when the product is used in extreme environments (significantly more severe than normal household use), this odour may become strong in a shorter period than expected. If the odour persists, the
lters should be replaced.
NOTE
• The air purifi er is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke). If the source of the odour still exists, the air purifi er may not completely remove the odour.
HEPA Filter
Washable Deodorizing Filter
Pre-Filter
(Common illustration has used “KC-850E”.)
ENGLISH
FEATURES
Unique Combination of Air Treatment Technologies Triple Filtration System + Plasmacluster + Humidifi cation
TRAPS DUST*
Washable pre-filter traps dust and other large airborne particles.
DECREASES ODOURS
Washable deodorizing fi lter absorbs many common household odours.
REDUCES POLLEN & MOLD*
HEPA filter traps 99.97% of particles as small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the way nature cleans the environment by emitting a balance of positive and negative ions.
HUMIDIFIES
Runs up to 10 hours per fi lling.** *When air is drawn through the filter sys-
tem. **Room size:
up to 48 m up to 38 m2 (KC-850E) up to 26 m2 (KC-840E)
Sensor Technology continuously monitors air quality, and automatically adjusting op­eration based on detected air purity and humidity.
2
(KC-860E)
CONTENTS
......
...
E-10 E-10 E-10
E-10
E-12
E-12 E-13 E-14 E-15
E-16 E-18
..
E-19
IMPORTANT SAFETY INSTRUCTIONS
• WARNING ..................................................
• CAUTIONS CONCERNING OPERATION .
• INSTALLATION GUIDELINES ....................
• FILTER GUIDELINES ................................
PART NAMES
• ILLUSTRATIVE DIAGRAM .........................
• BACK ..........................................................
• FRONT MONITOR .....................................
PREPARATION FOR USE ............................
• FILTER INSTALLATION .............................
• REFILLING WATER TANK .........................
OPERATION
• MAIN UNIT DISPLAY .................................
• CLEAN AIR & HUMIDIFY MODE ...............
• CLEAN AIR MODE .....................................
• CLEAN ION SHOWER MODE ...................
• FAN SPEED BUTTON ................................
• Plasmacluster ON/OFF BUTTON .............
• LIGHTS CONTROL BUTTON ..................
• WATER SUPPLY INDICATOR LIGHT ......
• ADJUSTMENT OF SENSOR
DETECTION SENSITIVITY ......................
CARE AND MAINTENANCE
• FILTER INDICATOR LIGHT .....................
• BACK PANEL AND SENSORS ................
• UNIT ........................................................
• WATER TANK ...........................................
• WASHABLE DEODORIZING
FILTER CARE ..........................................
• HUMIDIFYING TRAY ...............................
• HUMIDIFYING FILTER .............................
FILTER REPLACEMENT GUIDELINES
TROUBLESHOOTING SPECIFICATIONS
.............................................
...............................................
.................
............................
....................................
INFORMATION ON PROPER DISPOSAL
E-2 E-2
E-3 E-3 E-3
E-4 E-4
E-4 E-5
E-6 E-6
E-7 E-8 E-8
E-8 E-9 E-9 E-9
E-11 E-11
E-11 E-11
ENG
Thank you for purchasing this SHARP Air Purifier. Please read this manual carefully before using the air purifi er. After reading, keep the manual in a conven­ient location for future reference.
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING
• Read all instructions before using the unit.
• Use only a 220~240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened.
• Periodically remove dust from the plug.
• Do not insert fi ngers or foreign objects into the air intake or air outlet.
• When removing the power plug, always hold the plug and never pull on the cord.
Electrical shock and/or fi re from a short circuit may result.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or fi replaces.
When re lling the Water Tank, cleaning the unit, or when the unit is not in use, be sure to unplug
the unit. Electrical shock and/or fi re from a short circuit may result
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Centre or similarly qualifi ed person in order to avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as a bathroom.
• Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
• Only a Sharp Authorized Service Centre should service this air purifi er. Contact the nearest Service Centre for any problems, adjustments, or repairs.
• When carrying the unit, remove the Water Tank and Humidifying Tray fi rst and hold the unit by han- dles on both sides.
• Do not drink the water in the Humidifying Tray or Water Tank.
• Change the water in the Water Tank daily with fresh tap water and regularly clean the Water Tank and Humidifying Tray. (See E-12 and E-13). When unit is not in use, dispose of the water in the Water Tank and Humidifying Tray. Leaving water in the Water Tank and/or Humidifying Tray may result in mold, bacteria, and bad odours.
In rare cases, this bacteria may cause harmful physical effects.
• This appliance is not intended for use by persons (including children) with reduced physical, sen­sory or mental capabilities, or lack of experience and knowledge, unless they have been given su­pervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
– To reduce the risk of electrical shock, fi re or injury to persons:
NOTE
If this air purifi er should cause interference to radio or television reception, try to correct the interfer- ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation distance between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con­nected.
• Consult the dealer or an experienced radio/TV technician for help.
– Radio or TV Interference
E-2
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters, or where it may come into contact with steam.
• Always operate the unit in an upright position.
• Hold the unit by using the handles on both sides when moving.
Do not move when the unit is in operation.
• Do not operate the unit without the fi lters, Water Tank, and Humidifying Tray properly in- stalled.
• Do not wash and reuse the HEPA fi lter.
Not only does it not improve fi lter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
Do not use volatile fl uids and/or detergents. The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result.
• Frequency of maintenance required (descaling) will depend on the hardness or the impuri­ties of the water that you use; the harder the water the more often descaling will be neces­sary.
• Keep the unit away from water.
INSTALLATION GUIDELINES
• When using the unit, place at least 2m away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid use in locations where furniture, fabrics or other items may come in contact with and restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate conditions are when room temperature is between 5 – 35 ºC.
• Place on a stable surface with suffi cient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly. Place the unit on an even surface to avoid water leakage from the Water Tank and/or Humidifying
Tray.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack or the sensor may malfunction as a result.
• Place the unit about 30 cm~60 cm(1~2 ft) away from the wall in order to ensure proper air­ ow.
The wall directly behind the air outlet may become dirty over time. When using the unit for an ex-
tended period of time in the same location, periodically clean the wall and protect the wall with a vinyl sheet, etc. to prevent the wall from becoming dirty.
ENG
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the fi lters.
E-3
PART NAMES
ILLUSTRATIVE DIAGRAM – FRONT
Air Outlet
Main Unit Display
Front Monitor
Main Unit
KC-860E
BACK
Handle (2 locations left and right)
Sensors
• Dust Sensor
Temperature / Humidity Sensor
Odour Sensor(KC860E•KC850E)
Tank Handle
KC-850E
Air Outlet
Main Unit Display
Front Monitor
Main Unit
KC-840E
Air Outlet
HEPA Filter (white)
Washable Deodorizing Filter (black)
Tabs
Water Tank (For humidifying)
Humidifying Filter Filter Frame
Tank Cap
Float
Humidifying Tray
Power Cord
Plug
(Shape of plug depends on country.)
E-4
Air Inlet
Date Label
(Rating Label)
Back Panel (Pre-Filter)
Senso Reading
FRONT MONITOR
depending on odour
G
r
t
n
intensity
S
g
ed
ur
e
ow
Cle
All g
All g
Cle
g py
Sen
so
n
G
n
Ye
G
reen
Ye
n
d
A
ell
re
y
e
Reading
n
Very lm
e
d
e
All re
All re
Very lm
Indicates condition and humidity of room air.
KC-850E KC-860E
Indicates the room condition of odour, dust, and humidity.
ENG
DUST MONITOR
The dust sensor continuously monitors the air and changes colour depending on air purity. KC-860E has 5 levels of dust detector.
Sensor Reading
Clean
All green
Clean
All green
Green
Flashing
Yellow
Green
Flashing
Yellow
Very lmpure
Flashing
All red
Very lmpure
Flashing
All red
When the dust sensor detects dust, the fl ashing light moves depending on dustiness.
Plasmacluster Indicator Light (blue)
Blue: Plasmacluster ON Light off: Plasmacluster OFF
ODOUR MONITOR
The odour sensor continuously monitors the air and changes colour depending on odour intensity.
Odour in the room
Odou
Faint
in
ree
Green Yellow
Dust and odor are detected by different sensors.The colours may not change simultaneously.
in th
Yell
room
tron
Strong
R
Red
Water Supply Indicator Light (red)
This light will illuminate when the water tank needs to be refi lled.
Humidity Indicator Light (green)
Displays the approximate humidity level in the room. Humidity setting cannot be adjusted.
(Ex.) At 60 % humidily
80 % or more Less than 30 %
KC-840E
DUST MONITOR
The dust sensor continuously monitors the air and changes colour depending on air purity.
Clean
a
All green
a
Clean
ree
All green
When the dust sensor detects dust, the fl ashing light moves depending on dustiness.
Sensor Reading
Green
e
r
Flashing
Yellow
Green
Flashing
Flashing
Yellow
Flashing
pur
Very lmpure
All red
pur
Very lmpure
ll r
All red
Humidity Indicator Light (green)
Displays the approximate humidity level in the room. Humidity setting cannot be adjusted.
High – 65 % or more Med – 65 % or less of 40 % or more Low – 40 % or less
Water Supply Indicator Light(red)
This light will illuminate when the water tank needs to be refi lled.
Plasmacluster Indicator Light (blue)
Blue: Plasmacluster ON Light off: Plasmacluster OFF
E-5
Unplug the unit before installing
PREPARATION FOR
USE
or adjusting the fi lters.
FILTER INSTALLATION
To maintain the quality of the fi lters, they are packed in plastic bags and placed in the unit. Be sure to remove the fi lters from the plastic bags and replace the fi lters in the unit before initial use.
Remove the fi lters
1
Remove the Back Panel.
1
Gently push down on the tabs, then tilt and remove the back panel.
Tabs on the top
Back Panel
Remove the Wash-
2
able Deodorizing Filter (black) and HEPA Filter (white) from the plastic bags.
Install the fi lters
2
Install the HEPA Filter.
1
Please make sure that the HEPA Filter is placed in proper orientation.
Installing the filter backwards will affect the performance of the unit.
Tab
Insert the Back Panel’s 2 bottom tabs (left and right) into the small holes in the
2
unit, and slide the Washable Deodor­izing Filter between the HEPA Filter and the Back Panel.
Washable Deodorizing Filter
HEPA Filter
Back Panel
Bottom tabs
HEPA Filter
Washable Deodorizing Filter
Gently push in the up-
3
per tabs (left and right) to lock in place.
Upper tabs
Fill in the usage start
4
date on the Date Label.
Use the usage start date as a guide for when the fi lters should be replaced.
Date Label
E-6
REFILLING THE WATER TANK
The unit can be used in the Clean Air Mode without putting water in the Water Tank. When using the Clean Air & Humidify Mode, or the CLEAN ION SHOWER Mode, the Water Tank should be fi lled with water.
Remove the Water Tank by unlatching the
1
top.
Remove the Water Tank Cap and carefully
2
ll the Water Tank with tap water.
• Change the water in the Water Tank every day with fresh tap water.
After fi lling, securely tighten the Tank Cap.
3
• Check to see that there is no water leaking.
• Be sure to wipe off any excess water on the outside of the Water Tank.
• When carrying the Water Tank, hold it with both hands so that the Water Tank opening is facing up.
ENG
Tank Handle
Water Tank
Humidifying Tray
Water Tank
Tank Cap
tighten
Replace the Water Tank in the unit.
4
• The top latch will “click” in place when the Water Tank
is properly installed.
CAUTION
• Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result.
• Do not use hot water (40 ºC), chemical agents, aromatic substances, dirty water, or other damaging substances, deformation and/or malfunction may occur.
• Use only fresh tap water. Use of other water sources may promote the growth of mold, fun­gus and/or bacteria.
E-7
OPERATION
MAIN UNIT DISPLAY
Filter Reset Button/ Indicator Light (red)
Light Control Button
Fan Speed Button/ Indicator Light (green)
Plasmacluster ON/OFF Button/ Indicator Light (green)
Power ON Button
Press any of the buttons to se­lect mode and start the unit.
Clean Air & Humidify MODE Button/
Indicator Light (green)
Clean Air MODE Button/ Indicator Light (green)
Power OFF Button
CLEAN ION SHOWER MODE Button/
Indicator Light (blue)
CLEAN AIR & HUMIDIFY MODE
Use the Clean Air & Humidify Mode to quickly clean the air, reduce odours and to humidify.
Fill Water Tank. (See E-7)
1
Press the CLEAN AIR & HUMIDIFY MODE Button.
2
• If the power cord was not unplugged between uses, the unit will automatically re-start at the previously selected settings.
Press the FAN SPEED Button to select the de-
3
sired fan speed.
• Indicator lights will show the fan speed currently selected.
Press the Power OFF Button to turn the unit off.
About Automatic Humidify Mode
The Temperature/Humidity sensors automatically detect and adjust humidity according to changes in room temperature. Depending on the size and humidity of the room, humidity may not reach 55~65 %. In such cases, it is recommended that CLEAN AIR & HUMIDIFY/MAX MODE be used.
Temperature Humidity
~18 ºC 65 %
18 ºC~24 ºC 60 %
24 ºC~ 55 %
E-8
CLEAN AIR MODE
Use the Clean Air Mode when additional humidity is not required.
Press the CLEAN AIR MODE Button on the display.
1
• If the power cord was not unplugged between uses, the unit will automatically re-start at the previously selected settings.
Press the FAN SPEED BUTTON to select the de-
2
sired fan speed.
• Indicator lights will show the fan speed currently selected.
Press the Power OFF Button to turn the unit off.
CLEAN ION SHOWER MODE
CLEAN ION SHOWER Mode with humidifi cation releases high-density Plasmacluster ions. By continuously discharging strong airfl ow for 15 minitues, the unit effectively removes air-
borne dust, pollen, mold and allergens from the air as they are drawn through the fi lter system. Water must be in the Water Tank when this mode is selected.
The unit humidifi es when there’s water in the Water Tank, and it operates without humidifying
when there’s no water in it.
ENG
Press the CLEAN ION SHOWER MODE Button
1
on the display to select this mode.
When the operation fi nishes, the unit will return to the prior operation.
Press the Power OFF Button to turn the unit off.
Fan Speed Button
Please note the fan speed cannot be adjusted during the CLEAN ION SHOWER MODE.
AUTO operation
POLLEN mode
operation
MAX operation MEDIUM operation LOW operation
The fan speed is automatically switched (between HIGH and LOW) depend­ing on the amount of impurities in the air. The sensors detect impurities for effi cient air purfi cation.
The unit will operate at High Level for 10 minutes, then will atternate be­tween MEDIUM and HIGH.
The unit will operate at maximum fan speed. The unit will operate at medium fan speed. The unit will operate quietly using minimal air intake.
*HiGH fan speed is an intermediate speed between MEDIUM and MAX.
10 minutes: High fan level 20 minutes: Medium fan level 20 minutes: High fan level
E-9
OPERATION
Plasmacluster ON/OFF Button
Press the Plasmacluster ON/OFF Button to turn Plasmaclus­ter Ion Mode ON and OFF. When Plasmacluster is ON, both the Indicator Light and Plasmacluster Indicator Light turn on.
LIGHTS CONTROL Button
Use when the light on the
front panel is too bright.
CAUTION
The lights on the front monitor are always brighter when starting.
Refer to the diagram on the right to select the desired brightness on the front panel.
The lights on the front panel are brighter.
 「 」
 「 」
 「 」
The lights on the front panel are brighter.
The lights on the front panel are darker.
The lights on the front panel are darker.
The lights on the front monitor turn off.
The lights on the front monitor turn off
WATER SUPPLY INDICATOR LIGHT
When the Water Tank is empty, the Water Supply Indicator Light will fl ash to indicate that the Water Tank should be refi lled. Please note the light
will not fl ash even when the Water Tank is empty during the Clean Air Mode and the Clean ION SHOWER Mode.
Sound indicator setting for water supply.
In addition to the Indicator Light, the unit can be set to signal with an audible beep when the Water Tank is empty. With the unit OFF, press the Lights Control button for 3 seconds to turn the audible signal ON.
Cancellation
To cancel the audible signal, with the unit OFF, press the Lights Control button again more than 3 seconds.
Flashing
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
Set to “low” if the DUST MONITOR and ODOUR MONITOR is constantly red to reduce sensitivity, and set to “high’ if the DUST MONITOR and ODOUR MONITOR is constantly green to increase sensitivity.
With the unit OFF, press the Fan Speed Button for 3 seconds.
1
The Fan Speed Indicator Lights will display the currently set sensor sensitivity level. The factory setting is Standard, indicated by the MED light.
Press the Fan Speed Button to set the desired sensor sensitivity.
2
Refer to the diagram on the right to select the desired sensor sen­sitivity level.
Press the Power OFF Button.
3
Note that if the Power OFF Button is not pushed within 8 seconds of adjusting sensor sensitivity, the setting will be saved automati­cally. The sensor sensitivity setting will be saved even if the unit is unplugged.
E-10
Fan Speed Indicator Light
Sensor Detection sensitivity
High Standard Low
CARE AND MAINTENANCE
To maintain optimum performance of this air purifi er, please clean the unit including the sensor and fi lters periodically. When cleaning the unit, be sure to fi rst unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
ENG
FILTER INDICATOR LIGHT
The Filter Indicator Light will illuminate as a reminder to perform maintenance
of the Back Panel, Sensors, and Humidifying Filter. The Indicator Light will turn
on after approximately 720 hours of use.
After performing maintenance, reset the Filter Indicator. Plug the unit in, turn
power ON, and press the RESET button for 3 seconds. The Filter Indicator
Light will go off. Even if the Filter Indicator Light is already off, the RESET but-
ton should be pressed to reset the maintenance timer.
Care Cycle
After 720 hours of use
30days × 24hours = 720)
(
BACK PANEL and SENSORS
Care Cycle
Gently remove dust from the sensor opening and the
back panel, using a vacuum cleaner attachment or
similar tool.
When the back panel has stubborn dirt
In case of oily dirt, soak the back panel in water with kitchen detergent.
1
Avoid scrubbing the back panel hard when washing. Rinse the back panel repeatedly with clean water to re-
move the solution residue.
2
Drip dry fi lter to remove excess water.
Whenever dust accumulates on the unit or every 2 months
Sensor
Back Panel
Back Panel
3
SENSOR FILTER CARE
Remove the sensor filter and tap it lightly over a sink
or bin to dislodge dust. If it is very dirty, wash it gently
with lukewarm water. Do not use any detergents or
chemicals of any kind to clean the lter. Dry the fi lter
completely before replacing in the unit. Do not operate
unit without all fi lters properly installed.
Sensor Filter
UNIT
Care Cycle
To prevent dirt or stains on the unit, clean regularly. If stains are allowed to remain, they may
become diffi cult to remove.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fl uids
Benzene, paint thinner, polishing powder, may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Whenever dust accumulates on the unit or every 2 months
E-11
CARE AND MAINTENANCE
WATER TANK
Care Cycle
Rinse the inside of the tank by leaving a small amount of luke­warm water inside, closing the tank cap firmly, and shaking the tank. Mild household detergents may be used to clean the inside of the tank, but detergent should be diluted and the tank
should be thoroughly rinsed to remove all detergent residue. (Note the Water Tank is not dishwasher safe.)
TANK CAP CARE
The small cap back of the tank cap is removable. When the tank cap and small cap are dirty and slimy, cleaning is necessary. Use a cotton swab or a toothbrush.
Every day when Humidifying
care cycle... once a month
Tank Cap
Tank Cap
Water Tank
Toothbrush
WASHABLE DEODORIZING FILTER CARE
HAND WASH ONLY! DO NOT DRY IN CLOTHES DRYER!
Care Cycle
Rinse dirt from the WASHABLE DEODORIZING
1
FILTER under lukewarm water.
Remove dust on the washable deodorizing fi lter before washing.
When an unpleasant odour is noticed from the air outlet. When performance of fi lter seems to be reduced and odours persist.
CAUTION
• When washing the fi lter for the fi rst time, the rinse water may be brown. This does not affect deodorization performance.
• Avoid bending or folding the fi lter when washing.
Drip dry fi lter to remove excess water.
2
Dry filter completely in a well ventilated area. If
3
possible, dry outdoors.
Dry fi lter in a sideways position to avoid warping of the fi lter. The fi lter takes about 6 hours to dry out.
CAUTION
• Avoid drying fi lter outdoors during inclement weather (e.g. rain or cold temperatures).
Do not allow fi lter to freeze.
• If fi lter is dried indoors, take precautions, such as placing towels, etc under the fi lter to prevent water damage to the fl oor.
Replace the fi lter in unit. (See E-6).
4
Dry fi lter completely before replacing to prevent odours. Do not operate unit without all fi lters properly installed.
E-12
HUMIDIFYING TRAY
Care Cycle
Remove the Water Tank and Humidifying
1
Tray.
Unlatch the Water Tank first, then re­move the tray. Use both hands when pulling out the Hu­midifying Tray to avoid spilling water.
Remove the Humidifying Filter from the Humidifying Tray. Drain accumulated wa-
2
ter by tilting the Humidifying Tray slowly.
Humidifying Filter
1 month
Frequency of maintenance cycle will depend on the hardness of the water. Avoid spilling water when removing or cleaning the tray.
Tank Handle
Water Tank
Do not hold this part.
Humidifying Tray
Rinse the inside of the Humidifying
3
Tray with lukewarm water to remove impurities.
• Do not remove the Styrofoam fl oat.
• Clean diffi cult-to- reach parts with a cotton-tipped swab or tooth brush.
Float
Replace the Humidifying Filter and re-
4
place the Humidifying Tray in the unit.
The Humidifying Filter will not
t if placed in backwards. Be sure there is no gap between the Humidifying tray and the unit when the Humidifying Tray is replaced in the unit. The unit may not operate properly if the Humidifying Tray is not prop­erly replaced in the unit.
Colour: Gray
When Water Deposits are Diffi cult to Remove
Fill Humidifying Tray half­way with lukewarm water,
1
add a small amount of mild kitchen detergent, and leave to soak for about 30 min­utes.
Dilute detergent according to instructions on the container. Clean diffi cult-to-reach parts with a cotton swab or tooth brush.
Rinse the Humidifying
2
Tray with lukewarm wa­ter.
• Rinse until all detergent residue is removed.
• Inadequate rinsing may cause the de­tergent odour or changes in the shape/ colour of the main unit.
CAUTION
• Use only mild kitchen detergents to clean the Humidifying Tray. Use of non-designated chemicals or deter­gents can cause deformation, tar­nishing, cracking (water leakage).
ENG
If the Styrofoam fl oat comes off, replace by inserting the tabs of the Float into the holes in the Humidifying Tray as shown in the diagram.
Insert the tab of the oat into the hole.
Insert the fl oat below this tab.
Insert the tab on the other side of the oat into the hole.
E-13
CARE AND MAINTENANCECARE AND MAINTENANCE
HUMIDIFYING FILTER
Care Cycle
Frequency of maintenance cycle will depend on the hardness or the impuri you use; the harder the water the more often descaling will be necessary.
Pay attention not to spill water when cleaning the fi lter.
Remove the Water Tank and
1
Humidifying Tray.
Once a month or when the Filter Indicator Light is on.
ties of the water that
Rinse the Humidifying Filter re-
5
peatedly with lukewarm water to remove all the solution resi-
Humidifying fi lter
Humidifying Tray
Water Tank
Humidifying Tray
due.
Inadequate rinsing may cause odour and affect the performance and/or appear­ance of the unit.
* Do not scrub the Humidi-
fying Filter, rinse gently under lukewarm water only.
Attach the Humidifying Filter
Remove the Humidifying Filter
2
from the Humidifying Tray.
Avoid spilling water from the Humidifying Tray.
Preparing the descaling solu-
3
tion.
Citric acid, available at some drugstores, or 100 % bottled lemon juice are used for descaling. Choose either one to use, and prepare the descaling solution.
<For using citric acid>
Dissolve 3 teaspoons of citric acid and 2 1/2 cups of lukewarm water in a suitable container, and stir well.
<For using lemon juice>
100 % bottled lemon juice can be used for descaling. Use only 100 % bottled lemon juice with no pulp (strain juice if necessary). Combine 1/4 cup lemon juice and 3 cups of lukewarm water in a con­tainer large enough to hold the Humidify­ing Filter and stir well.
P
re-soak the Humidifying Filter
4
in the solution for 30 minutes before cleaning.
When using lemon juice, it is recommended to pre­soak longer than citric acid.
6
to the Humidifying Tray, and replace the Humidifying Tray in the unit.
•The Humidifying Filter will not fit if placed in backwards. Be sure there is no gap between the Humidifying Tray and the unit when the Humidifying Tray is replaced in the unit. The unit may not operate properly if the Humidifying Tray is not properly replaced in the unit.
•When not using the unit for a long peri­ods of time, dry the Humidifying Filter completely before replacing.
Plug in the unit, turn power
7
ON, and press the Filter Reset Button on the display for more than 3 seconds to reset.
You may notice reddish-brown or white deposits forming on the surface of the Humidifying Filter. These impurities (cal­cium, etc.) are due to the impurities con­tained in tap water; this is not a defect. Replace the Humidifying Filter when it is covered completely in white deposits.
E-14
FILTER REPLACEMENT GUIDELINES
Filter life will vary depending on the room environment, usage, and location of the unit. If dust or odours persist, replace the fi lters.
(Refer to “Please read before operating your new Air Purifi er”)
Guide for fi lter replacement timing
ENG
HEPA Filter
Filter life can be greatly reduced depending on the room environment. Cigarette smoke, pet dander, and other airborne particles can reduce fi lter life. Check fi lters regularly and replace as necessary.
Up to 5 years after opening
Washable Deodorizing Filter
The fi lter can be repeatedly used after washing, or it can be replaced.
Humidifying Filter
Filter life can be greatly reduced depending on the room environment. Even if 2 years have not passed, replace the Humidifying Filter if you notice the following:
• Mineral deposits (white, black, or red masses) which are not removed after cleaning or the Humidi­fying Filter is still dirty.
• Filter is severely damaged or warped.
Up to 2 years after opening
Replacement Filters
• HEPA Filter: 1unit
Model FZ-C150HFE (for KC-860E) FZ-C100HFE (for KC-850E) FZ-C70HFE (for KC-840E)
• Washable Deodorizing Filter: 1unit
Model FZ-C150DFE (for KC-860E) FZ-C100DFE (for KC-850E) FZ-C70DFE (for KC-840E)
• Humidifying Filter: 1unit Model FZ-C100MFE
(Gray)
Humidifying fi lter
Replacing the Filters
1. Replace fi lters according to the instructions provided with the replacement fi lters.
2. Use the date labels as a reminder for when the fi lters should be replaced.
Filter Frame (Gray)
Filter Frame (white)
Disposal of Filters
Please dispose of used fi lters according to any local laws and regulations. HEPA Filter materials:
• Filter: Polypropylene • Frame: Polyester
Washable Deodorizing Filter materials:
• Polyester, Rayon, Activated charcoal
Humidifying Filter materials:
• Rayon, Polyester
E-15
(white)
TROUBLESHOOTING
Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction.
SYMPTOM REMEDY (not a malfunction)
Odours and smoke are not removed.
The Front Monitor illuminates green even when the air is impure.
The Front Monitor illuminates orange or red even when the air is clean.
A clicking or ticking sound is heard from the unit.
The discharged air has an odour.
The unit does not operate when cigarette smoke is in the air.
Filter Indicator Light is illuminated.
• Clean or replace the fi lters if they appear to be heavily soiled. (See E-11,E-12,E-14)
• The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again.
• Sensor operation is affected if the dust sensor openings are dirty or clogged. Gently clean the dust sensors (See E-11).
• Clicking or ticking sounds may be audible when the unit is generating ions.
• Check to see if the fi lters are heavily soiled.
• Clean or replace the fi lters.
• Plasmacluster Air Purifi ers emit small traces of ozone which may produce an odour.
• Is the unit installed in a location that is diffi cult for the sensor to detect cigarette smoke?
• Are the dust sensor openings blocked or clogged?
(In this case, clean the openings.) (See E-11)
• After replacing fi lters, connect the power cord to an outlet and press the Filter Reset Button. (See E-11)
The Front Monitor are turned off.
The Water Supply Indicator Light does not illuminate when the tank is empty.
Water lever in the tank does not decrease or decreases slowly.
The Front Monitor lights change colour frequently.
• Check to see if the Lights OFF Mode selected. If so, then press the Lights Control Button to activate the indicator lights. (See E-10)
• Check Styrofoam fl oat for impurities. Clean the Humidifying- Tray. Ensure unit is located on a level surface.
• Check to see if the Humidifying Tray and Water Tank are cor­rectly installed. Check the Humidifying Filter.
• Clean or replace the filter when it is heavily soiled (See E-14 and E-15).
• The Front Monitor lights automatically change colours as im­purities are detected by the dust sensor and odour sensor.
E-16
ERROR DISPLAY
KC-850E•KC-860E
If error occurs again, contact the Sharp Service Centre.
DIGITAL INDICATION
LAMP INDICATION ERROR DETAILS REMEDY
Flashing of the Clean Air & Humidify Indicator Light.
Flashing of the Fan Speed Indicator Light '
Flashing of the Clean Ion Shower Indicator Light.
Flashing of the Clean Air Indi­cator Light.
Flashing of the Fan Speed In­dicator Light ' '.
Flashing of the Fan Speed In­dicator Light ' '.
'.
Abnormal humidity fi lter Verify if the Humidifying Filter,
Abnormal fan motor
Abnormal temperature­humidity sensor
Problem in circuit board
Humidifying Tray and Water Tank are properly installed and then turn power ON again.
Turn power OFF to cancel the error display, wait one minute, and then turn power ON.
Unplug the unit, wait one minute, and plug the unit in again.
ENG
KC-840E
LAMP INDICATION ERROR DETAILS REMEDY
Flashing of the Clean Air & Humidify Indicator Light.
Flashing of the Fan Speed Indicator Light '
Flashing of the Humidity Indi­cator Light ‘High’ or ‘Low’.
Flashing of the Clean Ion Shower Indicator Light.
Flashing of the Clean Air Indi­cator Light.
Flashing of the Fan Speed In­dicator Light '
Flashing of the Fan Speed In­dicator Light '
'.
'.
'.
Abnormal humidity fi lter Verify if the Humidifying Filter,
Abnormal fan motor
Abnormal temperature­humidity sensor
Problem in circuit board
Humidifying Tray and Water Tank are properly installed and then turn power ON again.
Turn power OFF to cancel the error display, wait one minute, and then turn power ON.
Unplug the unit, wait one minute, and plug the unit in again.
E-17
SPECIFICATIONS
Model KC-860E KC-850E KC-840E
Power supply 220 ~ 240 V 50/60 Hz
56 19 5.5 (4.9) 41 11.6 3.8 (3.3) 26 9.5 3.7 (3.4)
396 240 84 306 168 60 210 132 48
/hour)
3
Rated Power (W)
Fan Speed (m
Fan Speed Adjustment MAX MED LOW MAX MED LOW MAX MED LOW
CLEAN AIR
51 39 17 47 35 15 45 34 15
56 21 8.8 (8.2) 40 13.5 6.8 (6.3) 21 11.5 6.1 (5.8)
50 39 25 47 35 22 42 34 20
396 240 120 288 168 84 186 132 54
/hour)
3
Noise Level (dBA)
Fan Speed (m
730 500 300 600 400 230 450 330 170
Rated Power (W)
Noise Level (dBA)
Humidifi cation (mL/hour)*2
CLEAN AIR
& HUMIDIFY
Dust/odour/Temperature & Humidity Dust/Temperature & Humidity
)*1 ~48 ~38 ~26
2
Dust collection HEPA with Microbial control *3
Deodorization Washable Deodorizing
Recommended Room Size (m
Water Tank Capacity (L) 4.3 4.0 3.0
Sensors
Filter type
Cord Lenght (m) 2.0
Dimensions (mm) 398 (W) × 288 (D) × 627 (H) 378 (W) × 265 (D) × 586 (H) 360 (W) × 233 (D) × 550 (H)
Weight (kg) 11.0 9.0 8.0
The class of the HEPA fi lter by EN1822 2009 is E11.
Humidifi cation Amount increases as temperatures rise or humidity decreases.
Humidifi cation Amount decreases as temperatures decrease or humidity rises.
*1 • The Recommended Room Size is appropriate for operating the unit of maximum fan speed.
• The Recommended Room Size area indicates the space where a certain amount of dust particles can be removed in 30 minutes.
• Measurement Condition: 20 ºC, 30 % humidity (JEM1426)
*2 • Humidifi cation Amount changes in accordance with indoor and outdoor temperature and humidity.
*3 •
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this
product consumes about 0.7 W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.
E-18
Attention: Your product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collection system for these products.
A. Information on Disposal for Users (private households)
1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin!
Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. In some countries* your local retailer may also take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
If your used electrical or electronic equipment has batteries or accumulators, please dispose of these separately beforehand according to local requirements.
By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.
ENG
For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of
. Information on Disposal for Business Users.
B
www.swico.ch or www.sens.ch.
1. In the European Union
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.
For Spain: Please contact the established collection system or your local authority for take-back of your used products.
2. In other Countries outside the EU
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.
E-19
EN
Bitte lesen Sie sich diese Bedienungsanleitung vor der ersten Inbetriebnahme Ihres neuen Luftreinigers sorgfältig durch.
Der Luftreiniger saugt die Raumluft durch seinen Lufteinlass ein, führt diese Luft durch einen Vorfilter, einen auswaschbaren Desodorierungsfilter sowie einen HEPA-Filter im Inneren des Geräts und gibt die gereinigte Luft anschließend über den Luftauslass wieder aus. Der HEPA-Filter ist in der Lage, 99,97 % aller bis zu 0,3 Mikrometer klei­nen Staubpartikel zu beseitigen, die mit der angesaugten Luft durch den Filter geführt werden, und trägt so auch dazu bei, schlechte Gerüche zu beseitigen. Der auswasch­bare Desodorierungsfi lter absorbiert Schritt für Schritt die Gerüche beim Passieren der Luft durch den Filter.
Einige der durch die Filter absorbierten Gerüche können sich allerdings gegenseitig beeinfl ussen und so nach einer bestimmten Zeit eine eigene Geruchsentwicklung ver- ursachen. Je nach Betriebsumgebung und insbesondere bei Verwendung des Gerätes unter extremen Bedingungen (die nicht mehr den Bedingungen in einem herkömmli­chen Haushalt entsprechen), kann sich diese Geruchsentwicklung in einer kürzeren Zeit als ursprünglich angenommen verstärken. Falls diese Geruchsentwicklung anhält,
sollten die Filter ausgetauscht werden.
HINWEIS
• Der Luftreiniger wurde für die Beseitigung von in der Luft enthaltenem Staub und Gerüchen kon­zipiert; für eine Beseitigung schädlicher Gase (beispielsweise von in Zigarettenrauch enthaltenem Kohlenmonoxid) ist er nicht geeignet. Falls die Quelle eines bestimmten Geruchs nicht eliminiert wird, ist auch der Luftreiniger nicht in der Lage, diesen Geruch vollständig zu beseitigen.
HEPA-Filter
Auswaschbarer Desodorierungsfi lter
Vorfi lter
(Dieselbe Abbildung wurde auch beim Modell „KC-850E“ verwendet.)
DEUTSCH
LEISTUNGSMERKMALE
Einzigartige Kombination unterschied­lichster Technologien zur Luftbehand­lung Dreifachfi lter-System + Plasmacluster + Luftbefeuchtung
SAMMELT STAUB*
Der auswaschbare Vorfi lter entfernt Staub und andere größere Partikel aus der Luft.
REDUZIERT GERÜCHE
Der auswaschbare Desodorierungsfilter absorbiert die meisten herkömmlichen Haushaltsgerüche.
REDUZIERT POLLEN UND SCHIMMEL­PILZE*
Der HEPA-Filter fängt 99,97 % aller bis zu 0,3 Mikrometer kleinen Partikel ein.
AUFFRISCHUNG
Die Plasmacluster-Technologie sorgt für eine Verbesserung der Raumluft ähnlich wie in der Natur: sie gibt eine genau aus­balancierte Menge an positiven und nega­tiven Ionen ab.
LUFTBEFEUCHTUNG
Eine Füllung reicht für bis zu 10 Stunden.** *Wenn Luft durch das Filtersystem geführt
wird. **Raumgröße:
bis zu 48m bis zu 38m2. (KC-850E) bis zu 26m2. (KC-840E)
Die Sensortechnologie überwacht ständig die Luftqualität und stellt den Betrieb auf Grundlage der ermittelten Luftreinheit und
-feuchtigkeit automatisch ein.
2
. (KC-860E)
INHALT
WICHTIGE SICHERHEITSHINWEISE
• WARNUNG ................................................. D-2
• SICHERHEITSHINWEISE FÜR DEN
BETRIEB .................................................... D-3
• RICHTLINIEN ZUR INSTALLATION .......... D-3
• RICHTLINIEN ZUM UMGANG MIT
FILTERN ..................................................... D-3
BEZEICHNUNG DER EINZELNEN KOMPONENTEN
• EXPLOSIONSZEICHNUNG .......................
• RÜCKSEITE ...............................................
ANZEIGENFELD AN DER VORDERSEITE
VORBEREITUNG DER INBETRIEBNAHME
• FILTERINSTALLATION .............................. D-6
AUFFÜLLEN DES WASSERBEHÄLTERS
BETRIEB
• ANZEIGEN AM HAUPTGERÄT ................. D-8
• LUFTREINIGUNGS- UND
LUFTBEFEUCHTUNGSMODUS ............... D-8
• LUFTREINIGUNGSMODUS ...................... D-9
• IONENDUSCHE-REINIGUNGSMODUS ... D-9
• GEBLÄSEGESCHWINDIGKEITS-TASTE .. D-9
• PLASMACLUSTER-EIN-/AUS-TASTE ..... D-10
• LEUCHTANZEIGENSTEUERTASTE ....... D-10
• WASSERVORRATS-ANZEIGELEUCHTE .. D-10
• EINSTELLUNG DER SENSOR-
EMPFINDLICHKEIT ................................. D-10
.....................................................
PFLEGE UND WARTUNG
• FILTER-ANZEIGELEUCHTE ....................
• RÜCKWAND UND SENSOREN ..............
• GERÄT .....................................................
• WASSERBEHÄLTER ...............................
• PFLEGE DES AUSWASCHBAREN
DESODORIERUNGSFILTERS ................
• LUFTBEFEUCHTUNGSWANNE .............
• LUFTBEFEUCHTUNGSFILTER ...............
• RICHTLINIEN FÜR DEN FILTER AUS -
TAUSCH ...................................................
STÖRUNGSBESEITUNG TECHNISCHE DATEN
.......................................
.....................
.......................
............................
ENTSORGUNGSINFORMATIONEN
......
...........
D-2
D-4 D-4
D-4
...
D-5
...
D-6
... D-7
D-8
D-11 D-11
D-11 D-11 D-12
D-12 D-13 D-14
D-15 D-16
D-18 D-19
GER
Wir danken Ihnen herzlich für den Kauf eines Luftreinigers von SHARP. Bitte lesen Sie sich diese Bedienungsanleitung sorgfältig durch, bevor Sie den Luftreiniger in Betrieb nehmen. Bewahren Sie die Bedienungsanleitung nach dem Lesen an einem sicheren Ort auf, damit Sie bei Bedarf nachschlagen können.
D-1
WICHTIGE SICHERHEITSHINWEISE
Bei der Verwendung elektrischer Geräte müssen eine Reihe grundlegender Sicherheitshinweise einschließlich der folgenden beachtet werden:
WARNUNG
- Bitte halten Sie sich an die folgenden Anweisungen, um das Risiko von Strom­schlägen, Bränden oder Verletzungen bei Personen zu vermeiden:
• Lesen Sie sich die Bedienungsanleitung vor der Inbetriebnahme sorgfältig durch.
• Verwenden Sie ausschließlich eine Steckdose mit einer Spannung von 220 ~ 240 Volt.
• Verwenden Sie das Gerät auf keinen Fall, wenn das Netzkabel oder der Netzstecker beschädigt oder wenn der Anschluss an die Wandsteckdose instabil ist.
• Entfernen Sie regelmäßig den auf dem Stecker befi ndlichen Staub.
• Stecken Sie niemals Ihre Finger oder irgendwelche Gegenstände in den Lufteinlass oder -auslass.
• Halten Sie beim Entfernen des Netzsteckers stets den Stecker selbst und niemals das Kabel fest.
Anderenfalls kann es zu einem Kurzschluss und dadurch zu einem elektrischen Schlag bzw. Brand kommen.
• Fassen Sie den Stecker niemals mit feuchten Händen an.
• Verwenden Sie dieses Gerät niemals in der Nähe von Gasgeräten oder offenen Flammen.
Stellen Sie sicher, dass Sie das Gerät stets von der Stromversorgung abtrennen, bevor Sie den Wasserbehälter
auffüllen, das Gerät reinigen oder das Gerät über einen längeren Zeitraum hinweg nicht verwendet werden soll. Anderenfalls kann es zu einem Kurzschluss und dadurch zu einem elektrischen Schlag bzw. Brand kommen.
• Falls das Netzkabel beschädigt ist, muss es durch den Hersteller selbst, eine seiner Service Niederlas­sungen, ein durch Sharp autorisierten Dienstleister oder durch einen qualifizierten Techniker ausge­tauscht werden, um mögliche Risiken zu vermeiden.
• Betreiben Sie das Gerät niemals, wenn Sie Insektenspray verwenden oder wenn es sich in einem Raum befi n- det, in dem ölige Rückstände, Rauch von Räucherstäbchen, Funken eben angezündeter Zigaretten, chemische Dämpfe o. ä. in der Luft vorhanden sind; dasselbe gilt für Räume wie beispielsweise Badezimmer, in denen das Gerät feucht werden könnte.
• Lassen Sie bei der Reinigung des Geräts die gebotene Vorsicht walten. Stark ätzende Reinigungsmittel können eine Beschädigung der Außenfl äche verursachen.
• Die Servicearbeiten an diesem Luftreiniger sollten ausschließlich durch ein von Sharp autorisierten Dienstleister ausgeführt werden. Konsultieren Sie bei irgendwelchen Fragen oder Problemen hinsichtlich erforderlicher Ein­stellungen oder Reparaturen eine Service-Niederlassung in Ihrer Nähe.
• Entfernen Sie vor einem Transport des Geräts zuerst den Wasserbehälter und die Luftbefeuchtungswanne und halten Sie das Gerät beim Transport an beiden Griffen fest.
• Trinken Sie niemals das Wasser aus der Luftbefeuchtungswanne oder dem Wasserbehälter.
• Ersetzen Sie das Wasser im Wasserbehälter täglich durch frisches Leitungswasser und reinigen Sie den Wasserbe­hälter und die Luftbefeuchtungswanne in regelmäßigen Abständen. (Siehe dazu Seite D-12 und D-13).
Lassen Sie das Wasser aus dem Wasserbehälter und der Luftbefeuchtungswanne ab, wenn Sie das Gerät über
einen längeren Zeitraum hinweg nicht verwenden. Falls das Wasser im Wasserbehälter bzw. in der Luftbefeuch­tungswanne belassen wird, kann es zu Schimmelpilz- oder Bakterienbildung kommen, was schlechte Gerüche zur Folge hat.
In einigen wenigen Fällen können die so entstandenen Bakterien sogar schädliche Auswirkungen auf die Ge-
sundheit haben.
• Dieses Gerät ist nicht für die Benutzung durch Personen (einschließlich Kindern) gedacht, die nur über eingeschränkte körperliche, sensorische oder geistige Fähigkeiten oder mangelndes Wissen oder Erfahrung verfügen.
Es sei denn ihnen wurde Aufsicht oder Anweisung zur Benutzung des Gerätes, von einer für deren Sicherheit verant-
wortliche Person, gegeben.
Kinder sollten beaufsichtigt werden, damit sie nicht mit dem Gerät spielen.
HINWEIS
- Störung des Radio- oder Fernsehempfangs
Falls dieser Luftreiniger eine Störung des Radio- oder Fernsehempfangs verursacht, versuchen Sie bitte, die Störung durch eine oder mehrere der folgenden Maßnahmen zu beseitigen:
• Richten Sie die Empfangsantenne anders aus oder installieren Sie diese an einem anderen Ort.
• Vergrößern Sie den Abstand zwischen dem Gerät und dem Radio/Fernsehgerät.
• Schließen Sie das Gerät an eine Steckdose an, die mit einem anderen Stromkreis verbunden ist als die Steckdose, an die das Radio/Fernsehgerät angeschlossen ist.
• Konsultieren Sie Ihren Händler oder einen erfahrenen Radio-/Fernsehtechniker.
D-2
SICHEITHEITSHINWEISE FÜR DEN BETRIEB
• Blockieren Sie niemals den Lufteinlass bzw. -auslass.
• Verwenden Sie das Gerät niemals in der Nähe oder auf heißen Objekten wie beispielsweise Her­de, oder an Orten, an denen es mit heißem Dampf in Kontakt kommen könnte.
• Betreiben Sie das Gerät ausschließlich in aufrechter Stellung.
• Halten Sie das Gerät beim Transport immer an beiden Griffen fest.
Transportieren Sie das Gerät nicht, wenn es in Betrieb ist.
• Betreiben Sie das Gerät niemals, wenn die Filter, der Wasserbehälter oder die Luftbefeuch­tungswanne nicht ordnungsgemäß installiert sind.
• Waschen Sie den HEPA-Filter niemals aus; er kann nicht wiederverwendet werden.
Die Filterleistung würde dadurch nicht verbessert, obendrein besteht die Gefahr von Stromschlä-
gen oder Fehlfunktionen.
• Reinigen Sie die Außenfl ächen des Geräts nur mit einem weichen und trockenen Tuch.
Verwenden Sie keine leicht fl üchtigen Flüssigkeiten und/oder Reinigungsmittel. Anderenfalls könnte die Oberfl äche beschädigt oder rissig werden. Darüber hinaus könnte es zu einer Fehlfunktion der Sensoren kommen.
• Die Häufi gkeit der erforderlichen Wartung (Entkalkung) variiert je nach Wasserhärte oder Reinheit des von Ihnen verwendeten Wassers; je härter das Wasser ist, desto häufi ger ist eine Entkalkung erforderlich.
• Halten Sie das Gerät von Wasser fern.
RICHTLINIEN ZUR INSTALLATION
• Stellen Sie das Gerät für die Inbetriebnahme mindestens 2 m von Geräten entfernt auf, die elektromagnetische Felder erzeugen können oder mit Hochfrequenz arbeiten (wie beispiels­weise Fernsehgeräte oder Radios), um elektrische Störungen zu vermeiden.
• Meiden Sie Aufstellungsorte, an dem sich der Sensor im direkten Luftstrom (Wind) befi ndet.
Anderenfalls funktioniert das Gerät nicht ordnungsgemäß.
• Meiden Sie Aufstellungsorte, an denen Möbel, Textilien oder andere Gegenstände mit dem Lufteinlass bzw. -auslass in Kontakt kommen oder diesen blockieren könnten.
• Meiden Sie Aufstellungsorte, an denen das Gerät Kondensation oder extremen Temperatur­schwankungen ausgesetzt wäre. Die Betriebsumgebung ist geeignet, wenn die Raumtem­peratur zwischen 5 und 35 ºC liegt.
• Stellen Sie das Gerät auf einer stabilen Oberfl äche auf und achten Sie auf eine ausrei- chende Luftzirkulation.
Wenn das Gerät auf einem dicken Teppich aufgestellt wird, kann es zu leichten Vibrationen kom-
men.
Stellen Sie das Gerät auf einer ebenen Oberfl äche auf, damit kein Wasser aus dem Wasserbehäl-
ter bzw. der Luftbefeuchtungswanne austritt.
• Meiden Sie Aufstellungsorte, an denen sich Fett oder öliger Rauch ansammelt.
Anderenfalls könnte die Geräteoberfl äche rissig werden oder es könnte eine Fehlfunktion des Sen-
sors verursacht werden.
• Stellen Sie das Gerät 30~60 cm (1~2 ft) von der Wand entfernt auf, um eine ausreichende Luftbewegung zu gewährleisten.
Mit der Zeit kann es zu einer Verunreinigung der Wand direkt hinter dem Luftauslass kommen.
Wenn Sie das Gerät über einen längeren Zeitraum hinweg am selben Ort verwenden, reinigen Sie die dahinter befi ndliche Wand bitte regelmäßig und schützen Sie sie durch eine Vinylfolie o. ä., um eine Verunreinigung der Wand zu vermeiden.
GER
RICHTLINIEN ZUM UMGANG MIT FILTERN
• Befolgen Sie für eine ordnungsgemäße Pfl ege und Wartung der Filter alle in dieser Bedienungsan- leitung aufgeführten Anweisungen.
D-3
BEZEICHNUNG DER EINZELNEN KOMPONENTEN
EXPLOSIONSZEICHUNG - VORDERSEITE
KC-860E
RÜCKSEITE
Luftauslass
Hauptgerät­Anzeige
Vorderanzeige
Hauptgerät
KC-850E
Luftauslass
Hauptgerät-
Anzeige
Vorderanzeige
Hauptgerät
KC-840E
Griff (2, links und rechts)
Sensoren
• Staubsensor
Temperatur-/Feuchtigkeitssensor
Geruchssensor (KC860E•KC850E)
Tankgriff
Wasserbehälter (zur Luftbefeuchtung)
Luftbefeuchtungsfi lter
Filterrahmen
Tankdeckel
Schwimmer
Luftbefeuchtungswanne
Netzkabel
Stecker
(Die Steckerform variiert je nach Bestimmungsland.)
Lufteinlass
Datumsaufkleber
(Nennleistungs-Aufkleber)
Luftauslass
HEPA-Filter (weiß)
Auswaschbarer Desodo­rierungsfi lter (schwarz)
Laschen
Rückwand (Vorfi lter)
D-4
ANZEIGENFELD AN DER VORDERSEITE
ach Geruchsint
Luft.ensität der
g
g
Hier werden die Umgebungsbedingungen sowie die Feuchtigkeit der Raumluft angezeigt.
KC-850E KC-860E
Zeigt den Zustand der Raumluft nach Geruch, Staub und Feuchtigkeit an.
STAUBANZEIGE
Der Staubsensor überwacht die Raumluft ständig und ändert seine Farbe je nach Reinheitsgrad der Luft. Der KC-860E hat 5 Stufen der Stauberkennung.
Staub im Raum
Rein
Blinkend
Alle grün
Rein
Alle grün
Wenn der Staubdetektor Staub erkennt, bewegt sich das Blinklicht je nach Staub­anfall schneller oder langsamer.
Stark verunreinigt
Grün
Blinkend
Gelb Alle rot
Stark verunreinigt
Grün
Gelb
Alle rot
Plasmacluster-Leuchtanzeige (blau)
Blau: Plasmacluster Ein Erloschen: Plasmacluster Aus
GERUCHSANZEIGE
Der Geruchssensor überwacht die Raumluft ständig und ändert seine Far­be je nach Geruchsintensität der Luft.
Geruch im Raum
Schwach Stark
Grün Gelb Rot
Staub und Geruch werden von verschie­denen Sensoren erfasst. Daher ändern sich die Farben möglicherweise nicht gleichzeitig.
Wasserversorgungs-Leuchtanzeige (rot)
Diese Anzeige leuchtet, wenn der Was­serbehälter aufgefüllt werden muss.
Feuchtigkeits-Leuchtanzeige (grün)
Hier wird der ungefähre Feuchtigkeitsgrad der Raumluft angezeigt. Die Feuchtigkeits­einstellung kann nicht reguliert werden.
(Bsp.) Bei einer Luftfeuchtigkeit von 60 %
80 % oder mehr Weniger als 30 %
GER
KC-840E
STAUBANZEIGE
Der Staubsensor überwacht die Raumluft ständig und ändert seine Farbe je nach Reinheitsgrad der Luft.
Alle grün
Alle grün
Wenn der Staubdetektor Staub erkennt, bewegt sich das Blinklicht je nach Staub­anfall schneller oder langsamer.
Rein
Blinkend
Rein
Blinkend
Staube im Raum
Stark verunreinigt
Grün
Blinkend
Gelb Alle rot
Stark verunreinigt
Grün
Blinkend
Gelb Alle rot
Feuchtigkeits-Leuchtanzeige (grün)
Hier wird der ungefähre Feuchtig­keitsgrad der Raumluft angezeigt. Die Feuchtigkeitseinstellung kann nicht reguliert werden.
Hoch – 65 % oder mehr Mittel – zwischen 65 und 40 % Niedrig – 40 % oder weniger
Wasserversorgungs-Leuchtan­zeige (rot)
Diese Anzeige leuchtet, wenn der Was­serbehälter aufgefüllt werden muss.
Plasmacluster-Leuchtanzeige (blau)
Blau: Plasmacluster Ein Erloschen: Plasmacluster Aus
D-5
VORBEREITUNG DER INBETRIEBNAHME
Trennen Sie das Gerät von der Stromversorgung, bevor Sie die Filter installieren oder einstellen
FILTERINSTALLATION
Damit die hohe Qualität der Filter auch während des Transports beibehalten werden kann, wurden sie in Plastikbeuteln verpackt im Gerät installiert. Stellen Sie vor der ersten Inbetriebnahme des Geräts unbedingt sicher, dass Sie die Filter aus ihren Plastikbeuteln herausnehmen und ordnungsgemäß im Gerät installieren.
Filter herausnehmen
1
Nehmen Sie die Rück-
1
wand ab.
Drücken Sie die Laschen vorsichtig nach unten, kippen Sie die Rück­wand an und entfernen Sie diese.
Laschen an der Oberseite
Rückwand
Entnehmen Sie den
2
auswaschbaren De­sodorierungsfi lter (schwarz) und den HEPA-Filter (weiß) aus den Plastikbeuteln.
Filter installieren
2
Installieren Sie den HEPA-Filter.
1
Prüfen Sie, dass der HEPA-Filter ordnungsgemäß eingesetzt ist.
Falls die Installation verkehrt herum durchgeführt wird, wird die Leistung des Geräts erheb­lich beeinträchtigt.
Lasche
Setzen Sie die beiden unteren Laschen
2
der Rückwand (links und rechts) in die kleinen Öffnungen des Geräts ein und schieben Sie den auswaschbaren De­sodorierungsfi lter zwischen den HEPA- Filter und die Rückwand.
Auswaschbarer Desodorie­rungsfi lter
HEPA-Filter
Rückwand
Untere Laschen
HEPA-Filter
Auswasch­barer Desodo­rierungsfi lter
Drücken Sie leicht
3
gegen die oberen Laschen (links und rechts), bis der Filter einrastet.
Tragen Sie das Datum der
4
Inbetriebnahme auf dem Datumsaufkleber ein.
Verwenden Sie das Datum der Inbetriebnahme als Richt­linie für den künftigen Aus­tausch der Filter.
D-6
Obere Laschen
Datumsaufkleber
AUFFÜLLEN DES WASSERBEHÄLTERS
Im Luftreinigungsmodus kann das Gerät betrieben werden, ohne dass zuerst der Wasserbehälter aufge­füllt werden muss. Wenn Sie das Gerät allerdings im Luftreinigungs- und Luftbefeuchtungs- oder Ionen­dusche-Reinigungsmodus verwenden, sollten Sie den Wasserbehälter auffüllen.
Bauen Sie den Wasserbehälter aus, indem
1
Sie die Oberseite lösen.
Tankgriff
GER
Wasserbehälter
Luftbefeuch­tungswanne
Nehmen Sie den Deckel des Wasserbehäl-
2
ters ab und befüllen Sie den Wasserbehäl­ter vorsichtig mit frischem Leitungswasser.
• Ersetzen Sie das Wasser im Wasserbehälter täglich durch frisches Leitungswasser.
Schließen Sie den Tankdeckel nach dem
3
Befüllen fest und sicher.
• Stellen Sie sicher, dass keinerlei Wasser austritt.
• Wischen Sie überschüssiges Wasser von der Außen­seite des Wasserbehälters ab.
• Halten Sie den Wasserbehälter beim Transport mit beiden Händen fest und achten Sie darauf, dass die Wasserbehälteröffnung immer nach oben weist.
Setzen Sie den Wasserbehälter wieder in
4
das Gerät ein.
• Die obere Lasche rastet mit einem Klicken ein, sobald der Wasserbehälter ordnungsgemäß installiert ist.
Wasserbehälter
Tankdeckel
Anziehen
VORSICHT
• Halten Sie das Gerät von Wasser fern. Sonst könnte ein Kurzschluss und/oder ein Strom­schlag verursacht werden.
• Verwenden Sie kein heißes Wasser (40 ºC), chemische Zusätze, aromatische Substanzen, verunreinigtes Wasser oder andere schädliche Flüssigkeiten; anderenfalls kann es zu einer Verformung bzw. Fehlfunktion kommen.
• Verwenden Sie ausschließlich frisches Leitungswasser. Die Verwendung einer anderen Wasserquelle kann eine Schimmelpilz- bzw. Bakterienbildung fördern.
D-7
BETRIEB
ANZEIGEN AM HAUPTGERÄT
Filter-Rückstelltaste/ Anzeigeleuchte (rot)
Leuchtanzei­gensteuertaste
Gebläsegeschwindigkeits­Taste/ Anzeigeleuchte (grün)
Plasmacluster-Ein-/Aus-Taste/ Anzeigeleuchte (grün)
EIN-Taste
Drücken Sie eine beliebige Taste, um einen Modus auszuwählen und das Gerät zu starten.
Luftreinigungs- und Luftbefeuchtungs­MODUS-Taste/ Anzeigeleuchte (grün)
LuftreinigungsMODUS­Taste/ Anzeigeleuchte (grün)
AUS-Taste
IONENDUSCHE-REINIGUNGSMO­DUS-Taste/Anzeigeleuchte (blau)
LUFTREINIGUNGS- UND LUFTBEFEUCHTUNGSMODUS
Verwenden Sie den Luftreinigungs- und Luftbefeuchtungsmodus, um die Raumluft schnell und effektiv zu reinigen, unerwünschte Gerüche zu beseitigen und die Luft zu befeuchten.
Füllen Sie den Wasserbehälter auf. (Siehe dazu Seite D-7.)
1
Drücken Sie die LUFTREINIGUNGS- UND LUFT­BEFEUCHTUNGSMODUS-Taste.
2
• Falls Sie das Netzkabel zwischen den einzelnen Verwen­dungen nicht vom Stromnetz getrennt haben, wird das Gerät automatisch mit den zuvor ausgewählten Einstel­lungen gestartet.
Drücken Sie zur Einstellung der gewünschten Gebläsege­schwindigkeit die GEBLÄSEGESCHWINDIGKEITS-Taste.
3
• Die Anzeigeleuchte leuchtet und zeigt die gegenwärtig ausgewählte Gebläse­geschwindigkeit an.
Drücken Sie die AUS-Taste, um das Gerät auszuschalten.
Wissenswertes über den automatischen Luftbefeuchtungsmodus
Die Temperatur-/Feuchtigkeitssensoren erfassen die Luftfeuch­tigkeit automatisch und stellen die Feuchtigkeit entsprechend der Raumtemperatur ein. Je nach Größe und Luftfeuchtigkeit des Raums erreicht die Luftfeuchtigkeit u. U. nicht mehr als 55 ~ 65 %. In solchen Fällen empfehlen wir Ihnen die Verwen­dung des LUFTREINIGUNGS- UND LUFTBEFEUCHTUNGS­MODUS.
Temperatur
~ 18 ºC 18 ºC ~ 24 ºC 24 ºC ~
Luftfeuch­tigkeit
65 % 60 % 55 %
D-8
Loading...