NFORMATION ON PROPER DISPOSAL ......................... E-23
Thank you for purchasing the SHARP Air Purifier. Please read this manual carefully for the correct
usage information. Before using this product, be sure to read the section: “Important Safety Instructions.”
After reading this manual, retain it in a convenient location for future reference.
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
WARNING - To reduce the risk of electrical shock, fire or injury to persons:
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is
loosened.
• Periodically remove dust from the power plug.
• Do not insert fingers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
• Do not remove the power plug when your hands are wet.
• Do not use this unit near gas appliances or fireplaces.
• When pouring the water into the Tank, when cleaning the unit and when not using the unit, be
sure to unplug the power cord.
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a
bathroom.
• Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
• Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
• When carrying the Main Unit, please remove the Tank and MIST Tray and hold the Handles on both
sides.
• Do not drink in jest the water in the MIST Tray or Tank.
It may cause illness.
• Change the Tank water every day with fresh tap water.
Keep inside the Tank clean. (See Tank maintenance E-12)
Leaving water in the Tank will result in mold, bacteria, and bad odours.
In rare cases, this bacteria cause harmful physical effects.
• When not in use, dispose the water in the Tank and MIST Tray.
Leaving water in the Tank and MIST Tray will cause mold and bacteria.
NOTE - Radio or TV Intreference
If this air purifier should cause interference to radio or television reception, try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation distance between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
E-2
CAUTIONS CONCERNING OPERATION
• Do not block the intake and air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Do not lay the unit down when using.
• Always hold the handles on both sides of the unit when moving it.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in
bodily injury.
• Do not operate the unit without the filter.
• Do not wash and reuse HEPA filter .
Not only does it not improve filter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
The unit surface may be damaged or cracked.
In addition, the sensors may malfunction as a result.
• The frequency of maintenance (descaling) will depend on the hardness or the impurities of
the water that you use; the harder the water the more often descaling will be necessary.
INSTALLATION GUIDELINES
• During the operation of the product, please place the unit at least 2m away from equipments
which involve electric wave such as televisions, radios or wave clocks, in case electrical
interference occurs to such equipments.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid locations where curtains, etc., come into contact with the intake or air outlet.
Curtains, etc., may become dirty or a malfunction may occur.
• Avoid locations where the unit is exposed to condensation, due to drastic temperature changes.
(Use under appropriate conditions between 5 and 35˚C in the room.)
• Place on a stable surface with sufficient air circulation.
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
When placing the unit on an uneven surface, the water may leak from the Tank.
• Do not install when there is generation of lampblack, such as in a kitchen, etc.
The unit surface may crack or the sensor may malfunction as a result.
• Leave about 60cm of space from the ceiling and wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for extended
period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In
addition, periodically clean the wall.
ENGLISH
DEUTSCH
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the filters.
E-3
Please read before operating your new Air Purifier
The air purifier draws in room air from its air intake, lets the air pass through a
Washable Active Carbon Filter (deodorization filter) and a HEPA Filter (dust
collection filter) inside of the unit, then discharges the air from its air outlet.
The air purifier unit repeats this process by moving its internal fan.
As air passes through, a new HEPA Filter can remove 99.97% of dust particles, of as small as 0.3 microns. The Washable Active Carbon Filter gradually
absorbs odour elements as they repeatedly pass through the filter. (Odour
elements are absorbed by HEPA Filter as well.)
Some odour ingredients absorbed by the filters may become separated and
may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in a
condition significantly more severe than household use, this odour may become strong in a shorter period than expected.
If the odour persists, then the filters are fully expended and it is necessary to
purchase the optional replacement filter.
NOTE
• The air purifier is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot
completely remove the odour. (for example, odours from construction materials and pet odours).
• It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
Washable Active Carbon Filter
E-4
(Common illustration has used “KC-6500E”)
FEATURES
New Air Purifier with "Humidifying" ability beyond the "Two-in-one"
effect
"Synergy" of humidification and Plasmacluster ion realize the more powerful deodorization
and eliminating of airborne dust, mold, or microbes.
1.Simultaneously generating the Plasmacluster ions and vaporized mist realize the longer life
of ions and higher performance of purification.
(Not available to get this effect from separate Humidifier and Air Purifier.)
2. Powerfully decompose and remove the airborne microbes or house dust.
3. Effectively eliminating of static electricity which tend to be caused in a dry environment.
4. Powerful deodorizing - not only the airborne odour but the adherent one which is inside of
the fabric of clothes.
5. Provide the appropriate humidity in the room, and controls the activity of viruses in the dry
room.
6. Usual air purifying operation is available by selecting humidify off mode.
Powerful Humidifying Ion Shower Operation
Enhanced Ion Shower operation with humidification releases concentrated Plasmacluster ions
by repeating its airflow cycles between strong and gentle, effectively removes the airborne
dust, pollen, mold, and allergen.
Dual Filtering System
ENGLISH
1) Washable Active Carbon Filter
Collect the large dust particles at the surface, and absorbes odour elements.
Washable to maintain optimum deodorization performance.
2) HEPA (High Efficiency Particulate Air) Filter with Microbial control.
High efficiency filter can remove the dust particles as small as 0.3 microns.
DEUTSCH
E-5
PART NAMES
ILLUSTRATIVE DIAGRAM
(KC-6400E)
Control Panel
(KC-6500E)
Air Outlet
Temperature / Humidity Sensor
Odour Sensor
HEPA Filter (white)
Washable Active Carbon Filter
(black)
Main Unit
Front Panel
Control Panel
Air Outlet
Odour Sensor
Temperature / Humidity Sensor
Dust Sensor
Dust Sensor Filter
HEPA Filter (white)
Washable Active Carbon Filter
(black)
Filter Support
Main Unit
Front Panel
E-6
BACK
(KC-6400E)
Handle
(2 locations left and right)
Air Inlet
(left and right/bottom side)
Tank Handle
Tank
Tank Cap
Float
MIST Filter
Air Outlet
Date Label
Power Cord
Power Plug
ENGLISH
MIST Tray
(KC-6500E)
Handle
(2 locations left and right)
Air Inlet
(left and right/bottom side)
Tank Handle
Tank
Tank Cap
Float
MIST Filter
MIST Tray
INCLUDED
(Shape of plug depends on country.)
DEUTSCH
Air Outlet
Date Label
Power Cord
Power Plug
(Shape of plug depends on country.)
• Operation manual
E-7
PART NAMES
MAIN UNIT DISPLAY
Plasmacluster ON/OFF Indicator Light (green)
Plasmacluster ON/OFF Button
Plasmacluster Indicator Light
Clean Air Mode
Mode Selection Button
Operation Indicator
Light(green)
ION SHOWER
Mode Button
(Humidification +
Plasmacluster)
Colour
Cycle of light and shade
blue
Light off
Mode
Ion SHOWER
Plasmacluster ON
Plasmacluster OFF
CLEAN-SIGN Light
Air of room
redorangegreen
the colour of CLEAN-SIGN
DETERMINING THE BASE IMPURITY RATE
Clean
ION SHOWER Indicator Light (blue.green)
E-8
Humidify Mode
Mode Selection Button
Operation Indicator
Light(green)
Humidity Indicator Light (green)
Displays a rough measure of the current level of indoor
humidity. (Inputting your preferred humidity settings is not
allowed)
The unit will check the current level of humidity for one minute
immediately after the power is turned ON, during which time
numbers 30 - 70 flash sequentially.
MIST Filter Indicator Light (red)
Informs you when you must clean your
MIST Filter.
After cleaning
MIST Filter Reset Button
The Mist Filter Indicator Light turns off.
Power ON/OFF Button
Water Supply Indicator Light
(red)
Informs you when the tank needs to be
refilled with water.
(Ex.) At 50% humidity
ENGLISH
DEUTSCH
E-9
PREPARATION
Be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
To maintain the quality of the filters, they are installed in the main unit and packed in the
plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
Remove the filters
1
Remove the Front Panel.
1
Push in the hooks,
then pull the Front
Panel.
Front Panel
Hook
Remove the Filter Support.
2
Push in the hooks
on top , then pull
the Filter Support.
(Only KC-6500E)
2
Install the filters
Place the HEPA Filter within
1
the main unit.
Please make sure that the HEPA
Filter is placed in proper orientation.
Do not install the
filter backwards or
the unit will not
operate properly.
HEPA Filter
Place the Washable Active
2
Carbon Filter into the main
unit.
KC-6400E
Filter Support
Remove the Washable Active
3
Carbon Filter (black) and
HEPA Filter (white) from the
plastic bags.
HEPA Filter
Wachable Active
Carbon Filter
(At open)
The filter may sometimes discharge
deodorant powder, but such discharge does
not affect deodorizing performance.
Fit the Washable Active
Carbon Filter to the tab on
the top of the main unit.
Fit the band to the tab facing toward
you in the direction indicated by the
arrow, and insert fully.
band(blue)
E-10
KC-6500E
Place the Filter Support through
the bands (2 places) located at the
corners of the Washable Active
Carbon Filter.
Replace the Front Panel.
3
Filter Support
Washable Active
Carbon Filter
Band(blue)
Replace the Filter Support and
the Washable Active Carbon
Filter back to the main unit.
Filter Support
Front Panel
Fill in the usage start date
4
on the Date Label.
Use the date as a guide for the Filter Replacement schedule.
ENGLISH
DEUTSCH
E-11
Date Label
PREPARATION
Pour water into the Tank
This product can be used as an air purifier
without putting water in the tank.
Hold the tank handle and remove the tank.
1
Remove the tank cap and pour water.
2
• Use drinkable tap water.
(Generally speaking, tap water is sterilized with chlorine to suppress propagation of bacteria.)
• Change the tank water every day with fresh tap water.
Be sure to remove the power plug from the wall outlet.
Tank Handle
Tank
After supplying water, securely tighten the
3
tank cap.
• Check to see that there is no water leak.
• Be sure to wipe off any excess water around the tank.
• When carrying the tank, hold it with both hands so
that the tank opening is facing up.
Tank Cap
Tank
Mount the tank to the main unit.
4
• Insert the tank cap into the dented part of the unit.
• Make sure the tank is firmly attached by pushing it
in until you hear a click.
CAUTION
• Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result.
• Do not use hot water (of 40˚C or higher), chemical agents, aromatic substances, dirty water,
etc. Deformation and/or malfunction may occur as a result.
• Do not use mineral water, ionized alkaline water, well water, purified water, etc. Propagation of
mold fungus and bacteria may occur as a result.
• Securely tighten the tank cap. If the tank cap is difficult to tighten, loosen the cap one full turn
to properly set the cap to the tank.
Water Supply Indicator Light (red)
When the tank is dry and the water in the tray
begins to dry up, the Water Supply Indicator Light
will begin to flash.
Fill the tank with water.
When not operating in Humidify Mode, press the
Humidify Mode Selection Button to turn the mode
OFF; the Water Supply Indicator Light will turn off.
E-12
(Ex.) When water runs out during
Automatic Humidify Mode
Flashing
OPERATION
Plasmacluster ON/OFF
Indicator Light
CLEAN-SIGN
Light
POWER ON/OFF BUTTON
Press the POWER ON/OFF Button on the main unit.
1
• Mode activates after the short "beep".
• Unless unplug the power cord, the operation starts in the previous
mode the unit was operated in.
• When stop operation during ION SHOWER Operation, the unit
will back to the prior operation of ION SHOWER Operation.
• When the tank is dry, the Water Supply Indicator Light turns on.
When not operating in Humidify Mode, turn the mode OFF by
pressing the Humidify Mode Selection Button; the Water Supply
Indicator Light will turn off.
Clean Air Mode
Mode
Selection
Button
Plasmacluster Indicator
Light
Operation Indicator
Light
ION
SHOWER
Mode
Button
ION SHOWER
Indicator Light
Humidify Mode
Operation Indicator
Light
Humidity
Indicator Light
Mode Selection
Button
Power ON/OFF
Button
ENGLISH
DEUTSCH
Press the POWER ON/OFF Button on the main unit.
2
• Mode stops running after the long "beep".
ION SHOWER Mode Operation
When pushing the ION SHOWER Mode button, the ION SHOWER
operation will be activated. (Direct start is available even when the unit
is not turned on.)
The concentrated Plasmacluster Ions (ION SHOWER) will be generated
in the room like a shower for 15 minutes, repeating the airflow cycles
between strong and gentle. (The Plasmacluster Indicator Light repeats
its colour cycles between light and shade.), and effectively controls the
airborne dust, pollen, mold, and allergen.
• When the operation finishes, the unit will return to the prior operation.
• When pushing the ION SHOWER button while the ION SHOWER
operation mode is working, the unit will return to the prior operation.
Shower (Humidification + Plasmacluster Ion) Mode
E-13
OPERATION
Mode Selection Button
The operation mode can be switched, and the Indicator Light will turn on.
Clean Air
During operation
Humidify
During operation
Humidify and Clean Air Mode
Use the Clean Air Mode and Humidify Mode together to quickly remove house dust floating
in the air as well as eliminates odour. (for fresh air and those of saturated ones.)
During Normal Use
Clean Air : AUTO
Humidify : AUTO
For Quiet Use at Bedtime, Etc.
Clean Air : AUTO
Humidify : LOW
When Air is Dry
Clean Air : AUTO
Humidify : HIGH
4 sensors (a *Dust Sensor and an Odour Sensor for detecting
impurities in the air, and Temperature/Humidity Sensors for
detecting temperature and humidity) are used to automatically
control airflow volume in accordance with the state of your room.
2 sensors (a *Dust Sensor and an Odour Sensor for detecting
impurities in the air) are used to automatically control airflow
volume in accordance with the amount of impurities detected in
your room, while humidifying gently and quietly in "Humidify LOW"
Mode.
2 sensors (a *Dust Sensor and an Odour Sensor for detecting
impurities in the air) are used to automatically control airflow
volume in accordance with the amount of impurities detected in
your room, humidifying vigorously in "Humidify HIGH" Mode.
(Operation noise increases)
Only KC-6500E is equipped with the Dust sensor.
*
About Automatic Humidify Mode
The Temperature/Humidity
Sensors control humidity
automatically in accordance
with changes in room
temperature.
Depending on the size and dryness of your room, humidity
*
may not reach 55 - 65%. In such cases, it is recommended
to operate in "Humidify HIGH" Mode.
E-14
When operating Clean Air
Mode and Humidify Mode
together, Humidify Mode
takes priority.
Loading...
+ 36 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.