Sharp FU-55SE Operating Manual

4.5 (2)

R

Floor / Tabletop type Boden- / Tischgerät Type mobile

De instalación en el suelo / mesa Tipo da pavimento / tavola Vloermodel / tafelmodel

L

“Plasmacluster” is trademark of Sharp Corporation.

FU-55SE

AIR PURIFIER

 

 

 

 

 

 

 

 

 

ENGLISH

 

 

 

OPERATION MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

LUFTREINIGER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEUTSCH

 

 

 

 

 

 

 

 

BEDIENUNGSANLEITUNG

 

 

 

 

 

 

 

 

 

 

PURIFICATEUR D'AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

FRANÇAIS

 

 

 

MANUEL D'UTILISATION

 

 

 

 

 

 

 

 

 

 

PURIFICADOR DE AIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

ESPAÑOL

 

 

 

MANUAL DE USO

 

 

 

 

 

 

 

 

 

 

PURIFICATORE DELL’ARIA

 

 

 

 

 

 

 

 

 

 

 

 

 

ITALIANO

 

 

 

MANUALE OPERATIVO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LUCHTREINIGER

 

NEDERLANDS

 

 

 

GEBRUIKSAANWIJZING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

FEATURES

Cluster Ion Balance Control

The unit controls the ratio of Negative cluster ions and Positive cluster ions depending on the condition of the room.

• Clean mode

Approximately the same amount of Positive and Negative cluster ions are discharged. This mode is effective for reducing some airborne mold.

• Ion control mode

It is said that plenty of Negative cluster ions exist in places such as waterfalls or forests in natural environment. In this operation mode, Negative cluster ions will be released in an increased rate, in order to bring the room atmosphere close to this condition.

• AUTO cluster ion mode

The unit will switch between Clean mode and Ion control mode automatically depending on the amount of pollution in the air detected by dust and odor sensor.

HEPA filter

• High-efficiency dust collection

Active carbon filter

Powerful deodorization by large particles of columnar charcoal.

FOR UNDERSTANDING THE PRODUCT

Some of the odor ingredients absorbed by the filters become separated and are discharged through the Air Outlet as odor.

Depending on the usage environment, this odor may become strong in several months and the Air Outlet may smell.

In this case, purchase an exchange filter FZ-60SEF of the option goods, and replace the filters.

This equipment complies with the requirements of Directives 89/336/EEC and 73/23/EEC as amended by 93/68/EEC.

CONTENTS

SAFETY PRECAUTIONS ........................

E-2

• CAUTIONS CONCERNING THE OPERATION

OF THIS PRODUCT ....................................

E-3

• CAUTIONS CONCERNING

E-3

THE INSTALLATION ....................................

• ABOUT THE FILTER ...................................

E-3

NAMES OF PARTS .................................

E-4

• MAIN UNIT DISPLAY ...................................

E-4

• EXPLODED DIAGRAM ................................

E-4

• BACK ...........................................................

E-6

• ACCESSORIES ...........................................

E-6

SPECIFICATIONS ...................................

E-6

PREPARATION ........................................

E-7

• INSERTING BATTERIES

E-7

IN THE REMOTE CONTROL .......................

• USING THE REMOTE CONTROL ...............

E-7

• INSTALLING THE FILTERS .........................

E-8

OPERATION ..........................................

E-10

• MAIN UNIT OPERATION ..........................

E-10

• REMOTE CONTROL OPERATION...........

E-11

GUIDE FOR OPERATION .....................

E-12

CARE AND MAINTENANCE.................

E-13

• MAIN UNIT ................................................

E-13

• FILTER CLEANING ...................................

E-13

• DUST SENSOR, ODOR SENSOR ...........

E-13

• GUIDE FOR LIFE OF FILTERS ................

E-14

TROUBLE SHOOTING ..........................

E-15

 

 

Thank you for purchasing the SHARP FU-60SE. Please read this manual carefully for the correct operation. Before using this product, be sure to read The section: “Safety Precautions.” After reading this manual, retain it in a convenient location for future reference.

This product is for household use only.

E-1

ENGLISH

FU-55SE_Eng.6.5

1

03.7.17, 8:53 AM

SAFETY PRECAUTIONS

Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loose.

Electrical shock, short circuit and/or fire may occur as a result.

Do not damage, break, coat, forcefully bend, pull, twist, bundle, pinch or place heavy objects on the power cord.

If the power cord is damaged, fire and/or electrical shock may occur as a result.

Use AC 220-240V only.

Fire and/or electrical shock may occur as a result.

Do not modify. Repair and disassembly of this product are to be performed by authorized service personnel only.

Fire, electrical shock and/or bodily injury may occur if not.

For repair, contact your dealer of purchase or the nearest Sharp Service Centre.

Periodically remove dust from the power plug

Accumulated dust on the power plug may cause bad insulation from humidity, etc. Fire and/or electrical shock may occur as a result.

When cleaning the unit, be sure to remove the power plug from the wall outlet.

In addition, never handle the power plug with wet hands. Electrical shock and/or bodily injury may occur as a result.

Do not use the unit where there are oil ingredients such as cooking oil, etc., in the air.

Cracking of the unit surface may occur as a result.

Do not wipe the unit with benzene or paint thinner. Also, do not spray insecticides on the unit.

Cracking, electrical shock and/or fire may occur as a result.

Do not operate the unit when using indoor smoke-generating insecticides.

Chemical ingredients may accumulate within the unit and then discharge from the Air Outlet when the unit operates. Discharge of such chemicals may be unhealthy to your body.

Do not allow the unit to intake flammable gases, sparks from lit cigarettes, incense, etc.

The unit may ignite as a result.

Do not use the unit where it is humid, such as in a bathroom, or where the unit may get wet.

Electrical shock and/or malfunction may occur as a result.

Do not insert fingers or foreign objects into the intake or Air Outlet.

Electrical shock and/or malfunction may occur as a result.

When removing the power plug, always hold the plug and never pull the cord.

Electrical shock and/or fire from short circuit may occur as a result.

Ventilate when using the unit along with a heating appliance.

Carbon monoxide poisoning may occur as a result.

Remove the power plug when not using the unit.

Electrical shock from bad insulation and/or fire from short circuit may occur as a result.

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard.

The batteries must be removed from the appliance before it is scrapped and that they are disposed of safely.

E-2

FU-55SE_Eng.6.5

2

03.7.17, 8:53 AM

CAUTIONS CONCERNING THE OPERATION OF THIS PRODUCT

Do not block the intake and Air Outlet.

Do not use the unit near or on hot objects, such as a stove, etc. Also, do not use the unit where it may come into contact with steam.

Do not use the unit on its side.

Deformation, malfunction and/or overheating of the motor may occur as a result.

Do not install when there is generation of lampblack, such as in a kitchen.

Do not use detergent when cleaning the unit.

The unit surface may become damaged or cracked. In addition, the sensors may malfunction as a result.

Do not operate the unit without the filter.

It will have no purification effect. In addition, it becomes the cause of the trouble.

Do not wash and reuse filters.

They do not have effect, and it becomes an electric shock and the cause of the trouble.

CAUTIONS CONCERNING THE INSTALLATION

DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS

Location where there are inverter lighting equipment or electronic spontaneous lighting equipment

The remote control may become inoperative. In this case, move away from such lighting equipment or change direction.

Location exposed to direct sunlight

The unit may not receive signals from the remote control.

The unit may not respond to the signals of the remote control if the ends of fluorescent lighting become black or lights flicker due the depletion of service life; however, this is not a malfunction of the remote control or the main unit. In this case, replace the lighting with new fluorescent tubes.

TAKE CAUTION TO THE FOLLOWING DURING INSTALLATION

Leave at least 2m of space from televisions, radios and wave clocks.

Electrical interference may occur if not.

Leave at least 60cm of space from the wall

The motor may overheat, causing malfunction if not.

Avoid a location where sensors are exposed to direct wind

The unit may not operate properly.

Avoid a location where curtains, etc., come into contact with the intake or Air Outlet.

Curtains, etc., may become dirty or malfunction may occur as a result.

EFFECTIVE OPERATION

• Place on a stable surface with sufficient air circulation

ABOUT THE FILTER

Do not wash and reuse HEPA filter and Active carbon filter. They do not effect, and may become a cause of electric shock and trouble.

The wall, etc., behind the Air Outlet may become dirty as time passes. When using the unit for extensive period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall, etc.

E-3

ENGLISH

FU-55SE_Eng.6.5

3

03.7.17, 8:53 AM

Sharp FU-55SE Operating Manual

NAMES OF PARTS

MAIN UNIT DISPLAY

AUTO operation lamp Fan level lamps

OFF timer display lamps

(set using remote control)

Filter lamp

If the Filter lamp is lit, it indicates filter replacement period.

CLUSTER ION LAMP

Cluster ion operation is selected using the remote control.

Blue light

When the cluster ion operation is in Clean mode or AUTO cluster ion mode and the air in the room is dirty, this light turns on and the unit will operate in Clean mode.

Green light

When the cluster ion operation is in Ion control mode or AUTO cluster ion mode and the air in the room is clean, this light turns on and the unit will operate in Ion control mode.

Light off

No cluster ions are generated.

• The light can be turned off by using the ‘DISPLAY ON/OFF button’ on the remote control even while cluster ions are generated (Please turn off the lights when not required.)

EXPLODED DIAGRAM

E-4

FU-55SE_Eng.6.5

4

03.7.17, 8:53 AM

Loading...
+ 12 hidden pages