Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord
1
can result in damage to the unit and cause electrical shock.
Be careful not to expose your body directly to the outlet air for a long time. It may affect
2
your physical conditions.
When using the air conditioner for infants, children, elderly, bedridden, or disabled people
3
make sure the room temperature is suitable for those in the room.
E-16
ENGLISH
Never insert objects into the unit. Inserting objects can result in injury due to the high
4
speed rotation of internal fans.
Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe,
5
water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause
electric shock.
If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation
6
immediately and turn the circuit breaker OFF.
Follow local rules and regulations for power supply cord cabling. Improper cable
7
connection can cause the power supply cord, plug and the electrical outlet to overheat
and cause fire.
Use only the manufacture-specified power cord for replacement. Replacement should be
8
performed by a qualified technician or a service person.
WARNINGS FOR INSTALLATION / REMOVAL / REPAIR
• Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric
shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the
installation/removal/repair of the unit.
This equipment complies with the requirements of Directives 89/336/EEC and 73/23/
EEC as amended by 93/68/EEC.
E-1
PRECAUTIONS
CAUTIONS FOR USE
Open a window or door periodically to ventilate the room, especially when using gas
1
appliances. Insufficient ventilation may cause oxygen shortage.
Do not operate the buttons with wet hand. It may cause electric shock.
2
For safety, turn the circuit breaker off when not using the unit for an extended period of
3
time.
Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly
4
in place.
Do not put anything on the outdoor unit nor step on it. The object or the person may fall
5
down or drop, causing injury.
This unit is designed for residential use. Do not use for other applications such as in a
6
kennel or greenhouse to raise animals or grow plants.
Do not place a vessel with water on the unit. If water penetrates into the unit, electrical
7
insulations may deteriorate and cause electric shock.
Do not block the air inlets nor outlets of the unit. It may cause insufficient performance
8
or troubles.
Be sure to stop the operation and turn the circuit breaker off before performing any
9
maintenance or cleaning. A fan is rotating inside the unit and you may get injured.
Do not splash or pour water directly on the unit. Water can cause electrical shock or
10
equipment damage.
This appliance is not intended for use by young children or infirm persons without
11
supervision.
Young children should be supervised to ensure that they do not play with the appliance.
CAUTIONS FOR LOCATION / INSTALLATION
• Make sure to connect the air conditioner to power supply of the rated voltage and
frequency.
Use of a power supply with improper voltage and frequency can result in equipment
damage and possible fire.
• Do not install the unit in a place where inflammable gas may leak. It may cause fire.
Install the unit in a place with minimal dust, fumes and moisture in the air.
• Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting
of the room, furniture etc.
• Make sure a leak breaker or a circuit breaker is installed, depending on the installation
location, to avoid electrical shock.
E-2
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
INDOOR TEMP. OUTDOOR TEMP.
COOLING
HEATING
D.B. = Dry-bulb W.B. = Wet-bulb
upper limit
lower limit
upper limit
lower limit
32˚C D.B.43˚C D.B.
23˚C W.B. -
21˚C D.B.21˚C D.B.
15˚C W.B. -
27˚C D.B.24˚C D.B.
-18˚C W.B.
20˚C D.B.-7˚C D.B.
--8˚C W.B.
• The built-in protective device may prevent the unit
from operating when used
out of this range.
• Condensation may form on
the air outlet if the unit operates continuously in the
COOL or DRY mode when
humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re-start in the same settings which were active before
the power failure, except for timer settings.
If the timers were set before a power failure, they will need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on
to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
• When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an
automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the
inside and outside fans stop operating.
• After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
HEATING EFFICIENCY
• The unit employs a heat pump that draws heat from the outside air and releases it into the room.
The outside air temperature therefore greatly affects the heating efficiency.
• If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
• It takes time to warm up and heat the entire room because of the forced air circulation system.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
ENGLISH
SET THE CORRECT TEMPERATURE
• Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower
in the HEAT mode will save approximately 10 percent in power consumption.
• Setting the temperature lower than necessary during cooling operation will result in increased
power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
• Blocking direct sunlight during cooling operation will reduce power consumption.
• Close the windows and doors during cooling and heating operations.
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR
CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION
MAKE MOST OF THE TIMER OFF FUNCTION
DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN
EXTENDED PERIOD OF TIME
• The indoor unit still consumes a small amount of power when it is not operating.
! Inlet (Air)
@ Interconnecting Cord
# Refrigerant Tube and
$ Outlet (Air)
E-5
PART NAMES
REMOTE CONTROL
DISPLAY
FULL
POWER
MODE
FAN
SWING
1h
CLEAN
SET/C
1
2
3
4
5
6
7
8
9
0
q
w
e
r
t
y
u
i
o
1 TRANSMITTER
2 DISPLAY (Liquid Crystal Display)
3 DISPLAY Button
4 FULL POWER Button
5 ON/OFF Button
6 THERMO. (Thermostat) Button
7 MODE Button
8 FAN Button
9 ONE-HOUR OFF TIMER Button
0 TIMER ON Button (for setting the timer)
q TIMER OFF Button (for setting the timer)
w PLASMACLUSTER Button
(only for models AY-XPM7CR/AY-XPM9CR/AYXPM12CR)
e TIME ADVANCE Button
r TIME REVERSE Button
t SELF CLEAN Button
(only for models AY-XPM7CR/AY-XPM9CR/AYXPM12CR)
y TIMER SET/CANCEL Button
u Indicates BATTERY COMPARTMENT is
below this mark
i CLOCK Button
o SWING Button
L.C.D. REMOTE CONTROL DISPLAY
p THERMOSTAT SETTING FOR AUTO AND
DRY MODES
a SELF CLEAN SYMBOL
(only for models AY-XPM7CR/AY-XPM9CR/
AY-XPM12CR)
s TRANSMITTING SYMBOL
d MODE SYMBOLS
: AUTO: DRY
: HEAT: COOL
f TEMPERATURE INDICATOR
g FULL POWER SYMBOL
h FAN SPEED SYMBOLS
: AUTO: LOW
: HIGH: SOFT
E-6
p
a
s
d
AM
PM
AM
PM
AUTO
C
j TIMER ON INDICATOR/CLOCK
Indicates the on timer preset time or current
time.
k TIMER OFF INDICATOR
Indicates the preset time for off timer or onehour off timer.
l PLASMACLUSTER SYMBOL
(only for models AY-XPM7CR/AYXPM9CR/AY-XPM12CR)
f
g
h
j
k
l
SETTING DUST COLLECTION FILTER AND DEODORANT FILTER
(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
The dust collection filter and the deodorant filter are packed as accessory of this unit.
During operation of the air conditioner, the filters remove dust and tobacco smoke
from the air and discharges clean air.
Take out the air filters.
1
1 Open the open panel.
1
2
DUST COLLECTION FILTER (gray)
Set the black side facing upward.
3
2 Push the air filters up slightly to unlock
them.
3 Pull the air filters down to remove
them.
ENGLISH
Filter stopper
DEODORANT FILTER (green)
Filter stopper
3
2
1
Set the dust collection filter and the deo-
2
dorant filter under the filter stoppers located on the air filter.
Reinstall the air filters
3
1 Reinstall the air filters in the original
positions.
2 Close the open panel.
3 Push the arrow-marked of the panel
firmly to lock it in place.
Precautions
• The filters are sealed in a plastic bag to keep their dust collection effect.
Do not open the bag until using the filters. (Otherwise the filters life may get shorter.)
• Do not expose the filters to direct sunlight. (Otherwise they may deteriorate.)
E-7
Loading...
+ 17 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.