Sennheiser SKP 100 G3 - 01-09, SKP 100 evolution wireless G3 Instruction Manual

SKP 100
Instruction manual
1
Contents
Contents
The SKP 100 G3 plug-on transmitter .............................................................. 3
Areas of application ........................................................................................ 3
The frequency bank system .......................................................................... 3
Delivery includes .................................................................................................. 4
Product overview ................................................................................................. 5
Overview of the SKP 100 G3 plug-on transmitter .................................... 5
Overview of the displays ................................................................................ 5
Putting the plug-on transmitter into operation .......................................... 6
Inserting the batteries/accupack ................................................................. 6
Charging the accupack .................................................................................... 6
Plugging the plug-on transmitter onto a microphone ............................. 6
Using the plug-on transmitter ......................................................................... 7
Switching the plug-on transmitter on/off ................................................. 7
Deactivating the lock mode temporarily .................................................... 8
Muting the audio signal or deactivating the RF signal ............................ 8
Selecting a standard display ......................................................................... 9
Using the operating menu ............................................................................. 10
The buttons .................................................................................................... 10
Overview of the operating menu ............................................................... 10
Working with the operating menu .......................................................... 11
Adjusting settings via the operating menu ............................................... 13
The main menu “Menu” .............................................................................. 13
The extended menu “Advanced Menu” ................................................... 15
Synchronizing the plug-on transmitter with a receiver .......................... 17
Synchronizing the plug-on transmitter with the receiver –
individual operation ..................................................................................... 17
Synchronizing plug-on transmitters with receivers –
multi-channel operation .............................................................................. 17
Cleaning the plug-on transmitter ................................................................. 18
Recommendations and tips ........................................................................... 18
If a problem occurs ... ....................................................................................... 19
Accessories ......................................................................................................... 20
Specifications .................................................................................................... 21
Manufacturer Declarations ............................................................................. 22
Index .................................................................................................................... 23
Supplementary information can be found on the SKP 100 G3 product page on our website at www.sennheiser.com.
2
Important safety instructions
Important safety instructions
• Read this instruction manual.
• Keep this instruction manual. Always include this instruction manual when passing the product on to third parties.
• Heed all warnings and follow all instructions in this instruction manual.
• Use only a cloth for cleaning the product.
• Do not place the product near any heat sources such as radiators, stoves, or other devices (including amplifiers) that produce heat.
• Only use attachments/accessories specified by Sennheiser.
• Refer all servicing to qualified service personnel. Servicing is required if the product has been damaged in any way, liquid has been spilled, objects have fallen inside, the product has been exposed to rain or moisture, does not operate properly or has been dropped.
• WARNING: To reduce the risk of short circuits, do not use the product near water and do not expose it to rain or moisture.
Replacement parts
When replacement parts are required, be sure the service technician uses replacement parts specified by Sennheiser or those having the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards.
Intended use
Intended use of the ew 100 G3 series products includes:
• having read these instructions, especially the chapter “Important safety instructions”,
• using the products within the operating conditions and limitations described in this instruction manual.
“Improper use” means using the products other than as described in these instructions, or under operating conditions which differ from those described herein.
3
The SKP 100 G3 plug-on transmitter
The SKP 100 G3 plug-on transmitter
This plug-on transmitter is part of the evolution wireless series generation 3 (ew G3). With this series, Sennheiser offers high-quality state-of-the-art RF transmission systems with a high level of operational reliability and ease of use. Transmitters and receivers permit wireless transmission with studio-quality sound.
Features of the evolution wireless 100 G3 series:
• Optimized PLL synthesizer and microprocessor technology
HDX noise reduction system
•Pilot tone squelch control
• Switching bandwidth of 42 MHz
• Increased immunity to intermodulation and interferences in
multi-channel operation
Areas of application
The plug-on transmitter can be combined with the EK 100 G3 diversity receiver and the EM 100 G3 stationary receiver. These receivers are available in the same UHF frequency ranges and are equipped with the same frequency bank system. This has the advantage that
• a transmission system is ready for immediate use after switch-on,
• several transmission systems can be operated simultaneously on the
preset frequencies without causing intermodulation interference.
The frequency bank system
The plug-on transmitter is available in 6 UHF frequency ranges with 1,680 transmission frequencies per frequency range:
Each frequency range (A–E, G) offers 21 frequency banks with up to 12 channels each:
Each of the channels in the frequency banks “1” to “20” has been factory- preset to a fixed frequency (frequency preset).
Transmitter Combinable with ... Receivers
SKP 100 G3 all dynamic
microphones We recommend
using dynamic Sennheiser microphones
EK 100 G3 diversity receiver
EM 100 G3 stationary receiver
condenser microphones that are not phantom­powered, e.g. the Sennheiser K6 system
533.875
EM 100
20.12
PEAK
MUTE
P
-10
0 40 25 10
-20
-30
AF
RF
MHz
516 – 558
566 – 608
626 – 668
734 – 776
780 – 822
823 – 865
Range A: Range G: Range B: Range C: Range D: Range E:
Frequency bank 1 ... 20
Frequency bank U
Channel 12 – frequency preset
Channel 1 – frequency preset
Channel 2 – frequency preset
Channel 12 – freely selectable frequency
Channel 1 – freely selectable frequency
Channel 2 – freely selectable frequency
4
Delivery includes
The factory-preset frequencies within one frequency bank are intermodulation-free. These frequencies cannot be changed.
For an overview of the frequency presets, please refer to the supplied frequency information sheet. Updated versions of the frequency information sheet can be downloaded from the SKP 100 G3 product page on our website at www.sennheiser.com.
The frequency bank “U” allows you to freely select and store transmission frequencies. It might be that these transmission frequencies are not intermodulation-free.
Delivery includes
The packaging contains the following items: 1 SKP 100 G3 plug-on transmitter 2 AA size batteries, 1.5 V 1 instruction manual 1 frequency information sheet 1 RF power information sheet
5
Product overview
Product overview
Overview of the SKP 100 G3 plug-on transmitter
Overview of the displays
After switch-on, the plug-on transmitter displays the “Frequency/Name standard display. For further illustrations and examples of the different standard displays, refer to page 9. The display backlighting is automatically reduced after approx. 20 seconds.
Microphone input, XLR-3 socket
(female, unbalanced)
Mechanical locking ring of
XLR-3 socket
Infra-red interfaceDisplay panel, backlit in orange
UP button (
왖)
DOWN button (
왔)
Operation and battery status
indicator, red LED lit = ON flashing = LOW BATTERY
ON/OFF button
with ESC function (cancel)
MUTE switchSET buttonBattery compartment cover
Display Meaning
Audio level “AF Modulation of the plug-on transmitter with
peak hold function.
Frequency Current transmission frequencyName Freely selectable name of the transmitterTransmission icon RF signal is being transmittedLock mode icon Lock mode is activatedP” (pilot tone) Pilot tone transmission is activatedMUTE Microphone input is mutedBattery status Charge status:
MHz
533.875 ew100 G3
MUTE
P
AF
햲햳
approx. 100% approx. 70% approx. 30%
charge status is critical, the red
LOW BATTERY LED is flashing
:
6
Putting the plug-on transmitter into operation
Putting the plug-on transmitter into operation
Inserting the batteries/accupack
For powering the plug-on transmitter, you can either use two 1.5 V AA size batteries or the rechargeable Sennheiser BA 2015 accupack (see “Accessories” on page 20).
Slide the battery compartment cover in the direction of the
embossed arrow and open the cover 쐈.
Insert the two batteries or the accupack as shown below. Please
observe correct polarity when inserting the batteries/accupack.
Close the battery compartment.
The battery compartment cover locks into place with an audible click.
Charging the accupack
Remove the BA 2015 accupack.Insert the BA 2015 accupack into the L 2015 charger (see
“Accessories” on page 20).
Plugging the plug-on transmitter onto a microphone
Plug the microphone’s XLR-3M socket onto the transmitter’s XLR-3F
socket .
Tighten the locking ring in the direction of the arrow.
The L 2015 charger can only charge the BA 2015 accupack. Standard batteries (primary cells) or individual rechargeable battery cells cannot be charged.
The transmitter uses the microphone body as an antenna – therefore microphones with a metal casing should be used for best signal transmission.
7
Using the plug-on transmitter
Using the plug-on transmitter
To establish a transmission link, proceed as follows:
1. Switch the diversity receiver on (see the instruction manual of the receiver).
2. Switch the plug-on transmitter on (see next section). The transmission link is established and the diversity receiver’s RF level display “RF” reacts.
If you cannot establish a transmission link between plug-on transmitter and receiver, read the chapter “Synchronizing the plug-on transmitter with a receiver” on page 17.
Switching the plug-on transmitter on/off
To switch the plug-on transmitter on (online operation):
To switch the plug-on transmitter off:
If necessary, deactivate the lock mode (see page 8).
To switch the plug-on transmitter on and to deactivate the RF signal on
switch-on (offline operation):
It is vital to observe the notes on frequency selection on page 17.
Press the ON/OFF button 쐊.
The plug-on transmitter transmits an RF signal. The red
ON LED lights up and the “Frequency/Name” standard
display appears on the display panel. The transmission icon is displayed.
You can switch the plug-on transmitter on and deactivate the RF signal on switch-on. For more information, see below.
Keep the ON/OFF button 쐊 pressed until “OFF” appears on
the display panel. The red ON LED goes off and the display panel turns off.
When in the operating menu, pressing the ON/OFF button will cancel your entry (ESC function) and return you to the current standard display.
Keep the ON/OFF button 쐊 pressed until “RF Mute On?
appears on the display panel.
Press the SET button.
The transmission frequency is displayed but the plug-on transmitter does not transmit an RF signal. The transmission icon is not displayed.
Use this function to save battery power or to prepare a plug-on transmitter for use during live operation without causing interference to existing transmission links.
ON/OFF
ON/OFF
ON/OFF
SET
MHz
533.875 ew100 G3
MUTE
P
AF
Loading...
+ 18 hidden pages