SEH myUTN-2500 Quick guide

USB Deviceserver
myUTN-2500

Quick Installation Guide

MHAB-QI-myUTN2500 Version: 2.1 | 2018-11

Overview

This 'Quick Installation Guide' describes the hardware installation and initial setup of the myUTN-2500.
1.
Do you need assistance? Contact us!
Monday to Thursday Friday
8:00 a.m. to 4:45 p.m. and 8:00 a.m. to 3:15 p.m. (CET)
+49 (0)521 94226-44
support@seh.de
www.seh-technology.com

Überblick

Dieser 'Quick Installation Guide' beschreibt die Hardware-Installation und Inbetriebnahme des myUTN-2500.
Inhaltsverzeichnis
14.
Benötigen Sie Hilfe? Kontaktieren Sie uns!
Montag–Donnerstag Freitag
8:00–16:45 Uhr 8:00–15:15Uhr
+49 (0)521 94226-44
support@seh.de
www.seh.de

Contents

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Purpose .....................................................................................................................................2
Scope of Supply .....................................................................................................................2
Technical Data.........................................................................................................................3
LED Display ..............................................................................................................................4
Type Plate.................................................................................................................................4
Safety Regulations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Software Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Getting Started: SEH UTN Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Starting the SEH UTN Manager ........................................................................................9
Assigning an IP Address to the UTN Server................................................................10
Adding the UTN Server to the Selection List.............................................................11
Connecting the USB Device to the Client...................................................................12
Configuring the UTN Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Regulatory Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
1 [en] Quick Installation Guide

General Information

Purpose

The USB Deviceserver 'myUTN-2500' allows you to access non-network-ready USB devices (e.g. hard disks, etc.) in the network. For this purpose, the USB devices will be connected to the USB ports of the myUTN-2500. The software tool 'SEH UTN Manager' handles the access to the USB devices.
The SEH UTN Manager is installed on all clients that are intended to access a USB device in the network. The SEH UTN Manager shows the availability of all UTN servers in the network and establishes a connection between the client and the USB port including the connected USB device.
The administration of the myUTN-2500 is done via the 'myUTN Control Center'.

Scope of Supply

Check the package content before getting started:
UTN server USB Deviceserver 'myUTN-2500'
Quick Installation Guide
Power pack External power pack
The Quick Installation Guide provides a brief description of the installation of the myUTN-
2500. (This document)
Quick Installation Guide [en] 2

Technical Data

Link LED
(green)
Activity LED
(yellow)
USB ports 1–3
(port 3 = port for charging, 1.5 A)
LED for the USB ports 1–3
(green/orange)
Power LED
(yellow)
Status LED
(green)
Connector for the
included power pack
Reset buttonNetwork connector (RJ-45)
Properties Values
Network connector
logical:
physical: Device connection 3 × USB 3.0 SuperSpeed Current input • 200 mA at 12VDC without load
IEEE 802.3 (1000BaseT, 100BaseTX, and 10BaseT) 1 × RJ-45 (STP, category 5 or better)
• 2400 mA at 12VDC with full load on the USB ports
Power consumption • approx. 2.9 W without load
• approx. 30 W with full load on the USB ports
• approx. 26 kWh/year
Operating Environment Ambient temperature: 5–40 °C
Relative humidity: 20–80 %
Dimensions Width: 140 mm
Height 32 mm Depth: 99 mm Weight: 160 g
3 [en] Quick Installation Guide

LED Display

The LEDs of the UTN server provide information about its status.
LED Action Color Description
Link permanently on
green–There is a connection to the network.
permanently off
Activity blinks at
irregular intervals
Status permanently off
blinks 3 times
blinks 2 times
Power permanently on
permanently off
USB ports
permanently off
1–3
permanently on
There is no connection to the network.
yellow Indicates the exchange of network
data packets.
If the activity LED blinks periodically at the same time, the BIOS mode is signalized.
green
Indicates the assignment of a Zeroconf IP address.
green
Indicates the assignment of an IP address that does not correspond to
0.0.0.0 or that comes from outside the Zeroconf range.
yellow–The device is powered.
The device is not powered.
No USB device is connected to the respective port.
green
A USB device is connected to the respective port.
permanently on
orange
The connection to the respective port and the attached USB device is activated.
Important:
During the activation procedure, the behavior of the LEDs differs from this description.

Type Plate

The type plate gives important product information, such as hardware and certification information as well as the serial number. The serial number contains the production date: nnn YYYY MM nnnnn.
This information helps you e.g. during maintenance and you need it for support requests as well as for the guarantee extension.
Quick Installation Guide [en] 4

Safety Regulations

UTN servers are network devices for use in office environments. The myUTN­2500 is designed for the integration of USB devices into TCP/IP networks.
Important:
Before starting the installation and the initial setup procedure as well during the operation of the UTN server, note the following safety regulations. Their purpose is to protect yourself and others from personal injuries, and to avoid damage to the equipment.
• Read the documentation and make sure that your system meets the require­ments listed therein.
• Avoid contact with humidity or liquids.
• The device must only be connected and operated if it is in perfect condition.
• Make sure that no-one steps on or stumbles over the cables.
• If the supplied power cord cannot be used in your country, acquire an appro­priate power cord that suits national provisions. For more information, con­sult your retailer.
• Do not connect a telephone cable to the RJ-45 connector. The RJ-45 connec­tor may only be connected to SELV voltages. For the connection to the RJ-45 connector only STP cabling (category 5 or better) may be used. The shielding must fit flushly to the connector.
• Do not open the housing. Unauthorized modifications to the device can af­fect the product certification and are forbidden.
• The device must not be directly connected to outdoor lines.
• The device must only be operated using the power pack included in the package.
• Only use a certified USB cable (< 3 m) listed at www.usb.org
• Electrostatic discharges (ESD) may impair device performance.
• An interruption of the supply voltage may impair device performance or cause malfunctions.
.
5 [en] Quick Installation Guide

Hardware Installation

USB devices
myUTN-2500
network
clients with software tool 'SEH UTN Manager'
USB 3.0
USB 3.0
USB 3.0
You can directly connect three USB devices to the myUTN-2500.
1. Connect the USB device to a USB port of the UTN server.
Important:
USB device and UTN server can be connected via a USB cable, if required. Only use USB cables shorter than 3 meters.
2. Repeat step 1 if you want to connect more than one USB device.)
3. Connect the network cable (RJ-45) to the UTN server.
4. Connect the power cord to the UTN server. The UTN server boots and then is ready for use.
Quick Installation Guide [en] 6

Software Installation

The software tool 'SEH UTN Manager' organizes the access of the USB devices. The SEH UTN Manager is available in two versions:
•Complete version
• Minimal version (only command-line interface)
The complete version has a graphical user interface and offers additional features. A detailed description can be found in the myUTN User Manual.
The SEH UTN Manager is installed on all clients that are intended to access a USB device in the network. Different installation files are available, depending on the operating system.
First, you have to download the installation file for the SEH UTN Manager from the website of SEH Computertechnik GmbH:
http://www.seh-technology.com/services/downloads/
download-deviceserver/myutn-2500.html
System requirements: – Windows 7 or later except for Windows Server 20081;
OS X respectively macOS 10.9 or later
The installation can only be carried out by users with administrative rights.
Important:
The SEH UTN Manager is also available for selected Linux systems. All information necessary for installing and using the SEH UTN Manager in Linux environments can be found in the myUTN User Manual Linux. The documentation is available via the link given above.
1. Start the installation file.
2. Install the complete version of the SEH UTN Manager (including graphical
user interface). To do so, follow the installation routine.
The SEH UTN Manager is installed on your client.
1. Windows 7 and Windows Server 2008 R2: KB3033929 (https://technet.microsoft.com/en-us/li-
brary/security/3033929) must be installed.
7 [en] Quick Installation Guide
Loading...
+ 22 hidden pages