The USB Deviceserver 'myUTN-2500' allows you to access non-network-ready
USB devices (e.g. hard disks, etc.) in the network. For this purpose, the USB
devices will be connected to the USB ports of the myUTN-2500. The software
tool 'SEH UTN Manager' handles the access to the USB devices.
The SEH UTN Manager is installed on all clients that are intended to access a USB
device in the network. The SEH UTN Manager shows the availability of all UTN
servers in the network and establishes a connection between the client and the
USB port including the connected USB device.
The administration of the myUTN-2500 is done via the 'myUTN Control Center'.
Scope of Supply
Check the package content before getting started:
UTN serverUSB Deviceserver 'myUTN-2500'
Quick
Installation
Guide
Power pack External power pack
The Quick Installation Guide provides a brief
description of the installation of the myUTN-
2500.
(This document)
Quick Installation Guide[en]2
Technical Data
Link LED
(green)
Activity LED
(yellow)
USB ports 1–3
(port 3 = port for charging, 1.5 A)
LED for the USB ports 1–3
(green/orange)
Power LED
(yellow)
Status LED
(green)
Connector for the
included power pack
Reset buttonNetwork connector (RJ-45)
PropertiesValues
Network connector
logical:
physical:
Device connection3 × USB 3.0 SuperSpeed
Current input• 200 mA at 12VDC without load
IEEE 802.3 (1000BaseT, 100BaseTX, and 10BaseT)
1 × RJ-45 (STP, category 5 or better)
• 2400 mA at 12VDC
with full load on the USB ports
Power consumption• approx. 2.9 W without load
• approx. 30 W with full load on the USB ports
• approx. 26 kWh/year
Operating EnvironmentAmbient temperature:5–40 °C
Relative humidity:20–80 %
Dimensions Width:140 mm
Height32 mm
Depth:99 mm
Weight: 160 g
3[en]Quick Installation Guide
LED Display
The LEDs of the UTN server provide information about its status.
LEDActionColorDescription
Linkpermanently on
green–There is a connection to the network.
permanently off
Activityblinks at
irregular
intervals
Statuspermanently off
blinks 3 times
blinks 2 times
Powerpermanently on
permanently off
USB ports
permanently off
1–3
permanently on
There is no connection to the
network.
yellowIndicates the exchange of network
data packets.
–
If the activity LED blinks periodically
at the same time, the BIOS mode is
signalized.
green
Indicates the assignment of a
Zeroconf IP address.
green
Indicates the assignment of an IP
address that does not correspond to
0.0.0.0 or that comes from outside
the Zeroconf range.
yellow–The device is powered.
The device is not powered.
–
No USB device is connected to the
respective port.
green
A USB device is connected to the
respective port.
permanently on
orange
The connection to the respective
port and the attached USB device is
activated.
Important:
During the activation procedure, the behavior of the
LEDs differs from this description.
Type Plate
The type plate gives important product information, such as hardware and
certification information as well as the serial number. The serial number
contains the production date: nnn YYYY MM nnnnn.
This information helps you e.g. during maintenance and you need it for support
requests as well as for the guarantee extension.
Quick Installation Guide[en]4
Safety Regulations
UTN servers are network devices for use in office environments. The myUTN2500 is designed for the integration of USB devices into TCP/IP networks.
Important:
Before starting the installation and the initial setup
procedure as well during the operation of the UTN
server, note the following safety regulations. Their
purpose is to protect yourself and others from personal
injuries, and to avoid damage to the equipment.
• Read the documentation and make sure that your system meets the requirements listed therein.
• Avoid contact with humidity or liquids.
• The device must only be connected and operated if it is in perfect condition.
• Make sure that no-one steps on or stumbles over the cables.
• If the supplied power cord cannot be used in your country, acquire an appropriate power cord that suits national provisions. For more information, consult your retailer.
• Do not connect a telephone cable to the RJ-45 connector. The RJ-45 connector may only be connected to SELV voltages. For the connection to the RJ-45
connector only STP cabling (category 5 or better) may be used. The shielding
must fit flushly to the connector.
• Do not open the housing. Unauthorized modifications to the device can affect the product certification and are forbidden.
• The device must not be directly connected to outdoor lines.
• The device must only be operated using the power pack included in the
package.
• Only use a certified USB cable (< 3 m) listed at www.usb.org
• Electrostatic discharges (ESD) may impair device performance.
• An interruption of the supply voltage may impair device performance or
cause malfunctions.
.
5[en]Quick Installation Guide
Hardware Installation
USB devices
myUTN-2500
network
clients with software tool
'SEH UTN Manager'
USB 3.0
USB 3.0
USB 3.0
You can directly connect three USB devices to the myUTN-2500.
1. Connect the USB device to a USB port of the UTN server.
Important:
USB device and UTN server can be connected via a USB
cable, if required.
Only use USB cables shorter than 3 meters.
2. Repeat step 1 if you want to connect more than one USB device.)
3. Connect the network cable (RJ-45) to the UTN server.
4. Connect the power cord to the UTN server.
The UTN server boots and then is ready for use.
Quick Installation Guide[en]6
Software Installation
The software tool 'SEH UTN Manager' organizes the access of the USB devices.
The SEH UTN Manager is available in two versions:
•Complete version
• Minimal version (only command-line interface)
The complete version has a graphical user interface and offers additional
features. A detailed description can be found in the myUTN User Manual.
The SEH UTN Manager is installed on all clients that are intended to access a USB
device in the network. Different installation files are available, depending on the
operating system.
First, you have to download the installation file for the SEH UTN Manager from
the website of SEH Computertechnik GmbH:
http://www.seh-technology.com/services/downloads/
download-deviceserver/myutn-2500.html
System requirements:
–Windows 7 or later except for Windows Server 20081;
OS X respectively macOS 10.9 or later
–The installation can only be carried out by users with administrative rights.
Important:
The SEH UTN Manager is also available for selected
Linux systems.
All information necessary for installing and using the
SEH UTN Manager in Linux environments can be found
in the myUTN User Manual Linux. The documentation is
available via the link given above.
1. Start the installation file.
2. Install the complete version of the SEH UTN Manager (including graphical
user interface). To do so, follow the installation routine.
The SEH UTN Manager is installed on your client.
1. Windows 7 and Windows Server 2008 R2: KB3033929 (https://technet.microsoft.com/en-us/li-
brary/security/3033929) must be installed.
7[en]Quick Installation Guide
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.