WJ-Series
TURBINE METERS
APPLICATIONS
Remote totalizing
Pacing electronic metering
pumps
Cooling water monitoring
Industrial uid control
Water/Wastewater treatment
3” and 6” WJ Meters
Features
• Non-resettable mechanical
totalizer
• 2, 3, 4, 6, 8” pipe sizes
• Optional pulse output
• Rugged construction
• Accurate and economical
Contact Your Supplier
WJ-Series turbine meters are dry-register mechanical totalizers that
offer accurate, economical reading of high ows with low pressure loss.
The horizontal-axis turbine drives a vertical shaft, which is magnetically
coupled to the sealed register.
In addition to mechanical totalizing, registers can be equipped with
magnetic pulse reed sensors well suited for remote totalizing, pacing of
electronic metering pumps, and water treatment applications.
Bodies are manufactured of tough cast iron and epoxy-coated for
protection. Tungsten steel shafts and jewel bearings further enhance the
durability of these meters. Simple removal of the top ange brings out
all parts for inspection, repair, or replacement. The meter has a tamperevident seal to call attention to unauthorized access.
Compatible Seametrics controls include the PT35 pulse timer, the PD10
pulse divider, and the PS40 pulse splitter for running multiple pulseresponsive devices (e.g. pumps, counter timers and remote totalizers)
with a single WJ meter.
o
m
e
i
p
f
i
a
t
n
r
e
y
C
ISO
9001:2008
253.872.0284 seametrics.com
PROUDLY
MADE
IN THE
USA
WJ-Series
TURBINE METERS
Features
Register seal
Lid
Display
150 lb. ANSI drilling ange
Epoxy-coated cast iron body
Security bolt
& seal
Security Seals
3” Meter
Gaskets
included
Specications* Flow Range (GPM)
Materials Meter Body Cast iron, epoxy coating
Register Plate ABS plastic
Drive Magnet Alnico
Turbine Plastic
Turbine Shafts Tungsten steel
Bearings Jewel
Flanges 150 lb ANSI drilling
Maximum Pressure 150 psi (10 bar)
Maximum Temperature 105˚ F (40˚ C)
Accuracy Above Transition¹ ± 2% of reading
Below Transition
Reed Switch 100 mA @ 24 Vac/dc
* Specications subject to change. Please consult our website for
current data. (seametrics.com)
Note 1: See ow range table.
1
± 5% of reading
Minimum 2 5.3 8 20 33
Max. Continuous 132 352 528 1320 2200
Transition² 13 35 53 132 220
Note 2: The ow rate at which accuracy changes from ± 2% of reading
(above Transition) to ± 5% of reading (below Transition).
253.872.0284 Page 2 seametrics.com
2” 3” 4” 6” 8”