Seametrics SEB Specifications

FEATURES
9001:2008
CERTIFIED COMPANY
ISO
Single-jet meter
Compact brass body
Union couplings
Easy installation and maintenance
Interfaces with many controls and displays
APPLICATIONS
Industrial control operations
Low ow situations
Clean water
SEB
Low Flow Meter
GENERAL INFORMATION
The SEB is a plated brass low ow meter suited for clean water. It is available in 1/2” and 3/4” thread, with union­type meter couplings for easy installation and service. This meter is ideal for ow rates between 0.2 GPM (0.76 LPM) and 18 GPM (68.14 LPM). The SEB has only one moving part, the propeller.
A 5-30 Vdc square wave output makes the SEB ideal for many industrial control applications. This signal interfaces easily with programmable logic controllers and computer input boards. SEB meters can also be used in conjunction with the Seametrics FT420 ow computer for reading ow rate and total ow, or AO55 for 4-20 mA output. For me­tering pump pacing applications, a standard PD10 pulse divider is recommended.
SPECIFICATIONS*
Sensor
Fittings
Materials Body Rotor Chamber Rotor Shaft Bearings
Maximum Temperature
Maximum Pressure
Cable
Flow Range
Standard K-Factor
Accuracy
Regulatory
*Specications subject to change. Please consult our website for the most current data (www.seametrics.com).
GMR 5-30 Vdc current sinking pulse
1/2”, 3/4” male NPT union couplings
Nickel-plated brass
Brass
Thermoplastic Tungsten carbide Water-cooled thermoplastic
185˚ F (85˚ C)
175 psi (12 bar)
#22 AWG 3-cond, 12’ Maximum run 2,000’ (610 m)
1/2”: 0.2 - 10 GPM (0.76 - 37.85 LPM)
3/4”: 0.2 - 18 GPM (0.76 - 68.14 LPM)
1/2”: 550 pulses per gallon
3/4”: 330 pulses per gallon
+/- 1% of full scale
Mark
FEATURES
(-)
(+)
Signal
(White)
(Red)
(Black)
Power 5-30Vdc
Dim. 1/2 Inch3/4 Inch
A
F
E
D
C
B
2.5
9.2
2.8
4.35
3/4 in. BSPP
1/2 NPT 3/4 NPT
1 in. BSPP
5.1
2.8
10.4
2.5
(-)
(+)
Signal
(White)
(Red)
(Black)
Power 5-30Vdc
Hall-effect 12 Vdc signal interfaces with a variety of electronics
Removeable top contains electronics, isolated from uid
Union ends with couplings Easy installation and service
Compact nickel-plated body
INSTALLATION and MAINTENANCE
SEB
Low Flow Meter
Installation. Single-jet meters like the SEB are somewhat
insensitive to upstream and downstream ow conditions. For best results, however, upstream and downstream straight pipe of ve pipe diameters is recommended.
Maintenance. The SEB’s Hall-effect sensor and cap are eld­replaceable.
DIMENSIONS SENSOR CONNECTION
D
12 ft. (3.66 m) cable
(White)
(Black)
(Red)
E
A
(Meter Thread, Male BSPP)
Dim. 1/2 Inch3/4 Inch
B (with fittings)
F (Male NPT)
A
B
C
D
E
F
2.5
9.2
2.8
4.35
3/4 in. BSPP
1/2 NPT
Signal
(-)
(+)
Power 5-30Vdc
2.5
10.4
2.8
5.1
1 in. BSPP
3/4 NPT
HOW TO ORDER
MODEL SIZE
SEB
SEB
ACCESSORIES
Remote rate and total display = FT420W Pulse divider = PD10
4-20 mA output = AO55W
Seametrics Incorporated • 19026 72nd Avenue South • Kent, Washington 98032 • USA
(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • www.seametrics.com
1/2” = -050 3/4” = -075
CONTACT YOUR SUPPLIER
LT-65650048-120913
12/09/2013