PE202
LOW FLOW MAGMETER
APPLICATIONS
Chemical injection
Corrosive materials
Low ow applications
Pulsating ows
(e.g., metering pump)
Features
• No moving parts
• Requires no straight pipe
• Pulse and/or 4-20 mA output
• Chemical and corrosion
resistant
• Insensitive to uid density and
uid viscosity changes
The PE202 magmeter is designed for low-ow chemical injection or
difcult-to-meter applications with pulsating metering pumps in 3/4” to
1/4” pipe/tube. The housing is made of sturdy splashproof HDPE plastic.
With no moving parts, the PE202 can handle uids containing particulate
matter without clogging or jamming, keeping maintenance at a minimum.
With no metallic parts (100% PVDF body and PVDF carbon ber-lled
electrodes), the meter is corrosion-resistant and compatible with a wide
range of chemicals. Accuracy is maintained with conductive uids (>20
microSiemens) of varying viscosities and densities.
The PE meter is compact enough to t most pump/injection systems.
With zero straight pipe required after an elbow, it can be easily mounted
in tight spaces. The mounting bracket adds stability.
The PE meter has an optoisolated current sinking pulse output that can
be connected to the Seametrics FT430/440 rate/total display or FT520
batch processor, as well as an optoisolated 4-20 mA current loop for
powering analog devices. Outputs and power are provided through a 20
foot (6 meter) cable with 8-pin female circular connector.
Contact Your Supplier
o
m
e
i
p
f
i
a
t
n
r
e
y
C
ISO
9001:2008
253.872.0284 seametrics.com
PROUDLY
MADE
IN THE
USA
PE202
LOW FLOW MAGMETER
Features
Mounting bracket
8-pin circular bulkhead connector, 20 foot (6 meter) cable provided
Internals made of chemical and corrosion-resistant PVDF
Sturdy HDPE housing
½” male NPT
ttings standard
Threaded male or female NPT adapters
can be purchased separately
(available in PVDF and PP)
(Female NPT available in 1/2” only)
Specications*
Pipe Size 3/4”, 1/2”, 3/8”, 1/4” **
Fittings 1/2” NPT ttings standard in 3/4” or 3/8” owbody. NPT threaded adapters available for above pipe sizes.
Materials Body PVDF
Electrodes PVDF carbon ber lled
Ground PVDF carbon ber lled
Housing HDPE with 25% glass
Adapters (NPT) Polypropylene or PVDF
Temperature Ambient 0˚ to 130˚ F (-18˚ to 54˚ C)
Fluid 32˚ to 200˚ F (0˚ to 93˚ C)
Pressure 150 psi
Flow Range -075 20 GPM max. (0.2 GPM cutoff)
-038 3 GPM max. (0.03 GPM cutoff)
Accuracy -075 ±1% plus ±0.005 GPM of reading across rated range
-038 ±1% plus ±0.002 GPM of reading across rated range
Output Signal Optoisolated current sinking or current sourcing pulse output: 30 Vdc, 5 mA max
-075 500 pulses/liter (1892 pulses/gallon)
-038 1000 pulses/liter (3785 pulses/gallon)
Power 10–15 Vdc, 150 mA (linear power supply recommended)
Conductivity >20 microSiemens
Empty Pipe Detection Hardware/software, conductivity-based
Environmental
* Specications subject to change • Please consult our website for current data (seametrics.com).
** Requires adaptors
NOTE: Consult factory for applications owing sodium hypochlorite, sodium chlorite, sodium chlorate.
For applications with the listed chemicals, the following conditions apply:
• Max concentration 15% / Max temperature 100˚ F
• Flow is greater than 20% of max for accurate reading
Optoisolated 4-20 mA current loop: 7 Vdc plus load voltage drop min; 50 Vdc max
NEMA 4X standard; IP66 splashproof standard
253.872.0284 Page 2 seametrics.com