![](/html/f1/f1e0/f1e05aaf662fb41b69ef82f7aae6667cacdac9b43f3c76f67f8e37f8411a18c6/bg1.png)
PD10
PULSE DIVIDER
INSTRUCTIONS
PD10 PULSE DIVIDER INSTRUCTIONS
9001:2008
ISO
CERTIFIED COMPANY
![](/html/f1/f1e0/f1e05aaf662fb41b69ef82f7aae6667cacdac9b43f3c76f67f8e37f8411a18c6/bg2.png)
GENERAL INFORMATION & SPECIFICATIONS
Designed for use as a meter accessory, the PD10 divider is
used primarily for pacing electronic metering pumps. Any
number from one to 9999 can be set on rotary switches.
Each time the divider has received the set number of pulses
from the meter, it puts out one pulse to stroke the pump.
The PD10 is also useful in boiler and cooling tower feed and
bleed operations, and for lowering frequency output of high
frequency meters. Compatible with all Seametrics ow meters,
the PD10 creates a programmable pulse meter with an easily
adjustable pulse rate.
FEATURES
Protective cover
Rotary Switches (4)
Mounting Holes:
(Double-backed pressure-sensitive
tape also supplied standard)
The PD10 comes in two different housings: an enclosure that
can be mounted near the pump, and a watertight housing for
mounting on the meter.
Potted for environmental
protection
Wall (Pump) housing shown
(Meter mount also available)
To leads or metering
pump connector
SPECIFICATIONS*
Page 2
Enclosure Wall (Pump) Mount
Meter Mount
Temperature
Divider Range
Setting Mechanism
Power
Maximum Sensor Load
Maximum Input Frequency
Maximum Output Frequency
Output
Output Pulse Width
Input Connection Wall Mount
Meter Mount
Output Connection Wall Mount
Meter Mount
*Specications subject to change • Please consult our website for current data (www.seametrics.com).
Epoxy-encapsulated ABS housing with cover
Cast aluminum sealed housing
0˚ to 130˚ F (-18˚ to 55˚ C)
1 to 9999
Rotary switches
7 - 30 Vdc @ 4 mA
20 mA
350 Hz (pulses/second)
8 Hz (pulses/second)
Solid state relay; 0-250 V, 170 mA max AC/DC
0.1 second
Seametrics connector
Terminal
Pump connector on 24 inch lead
Comes with 18 foot lead
Input connector for
Seametrics meter connector