Seametrics PC Specifications

PC42
PC-Series
Power Supply
PC3
Features
Single or dual power supply
Rugged plastic housing
Wall, panel, DIN rail or outlet mounting
styles
24 Vdc and 12 Vdc, depending on model
Model Power Regulation Mounting
PC42 Dual 24 Vdc
o
m
e
i
p
f
i
a
t
n
r
e
y
C
ISO
9001:2008
PC3 24 Vdc Unregulated Outlet
PC12 12 Vdc Regulated Wall or DIN rail
and 12 Vdc
Regulated Wall or Panel
Applications
Power supplies for:
Flowmeters
Indicators and controllers
4-20 mA loop devices
Magmeter/indicator combinations
PC12
PC-SERIES POWER SUPPLY
PC42 Dual Power Supply
PC42
The PC42 dual regulated power supply is designed for applications in which a magmeter is used together with a 4-20 mA transmitter such as the AO55 or FT440. Although a single 24 Vdc power supply can be used, there is a risk of a ground loop interfering with proper operation of the 4-20 mA current loop. This risk is eliminated by the dual power supply.
The housing is rugged molded ABS plastic, NEMA 4X rated. It can be wall or panel mounted. The PC42 can be hardwired to the AC main supply or plugged into a standard outlet using the included power cord. Inside there are separate terminals to connect the two devices to the fully isolated supplies.
Installation and Connections
Remove the cover to expose the four mounting holes at the bottom of the cover screw tubes. Mark the mounting surface, drill, and attach with screws. Do not drill additional holes in the box. Doing so will allow moisture into the enclosure.
Specications*
Input Power 115 Vac/230 Vac ±10%,
Output Voltage/Current
(Regulated)
Terminal Block Wire 22–12 AWG
Operating Temperature -4˚ to 140˚ F (-20˚ to 60˚ C)
Environmental NEMA 4X
* Specications subject to change. Please consult our website
for current data (seametrics.com)
internally switchable, 50/60 Hz
12 Vdc ±1% @ 350 mA 24 Vdc ±4% @ 100 mA
Dimensions
4.93”
12.52 cm
Caution 1: Important! Do not connect power to the PC42 until all connections have been made and
conrmed correct, and the cover has been put back into
place.
Caution 2: It is essential for safety and proper operation to use a ground connection for the 115 Vac power. Do not use this power supply without proper grounding.
PWR
SW
G
AC
Earth
AC
Ground
Pre-wired power cord Replace if required
115Vac, 50/60Hz
AC
AC
350 mA Max
4.93”
12.52 cm
4-20 mA Device
Analog Output
-
+
24V12V
-
-
+
+
(N/C)
FT420
FT440
Display Module
Display Module
-
Power Input
+
-
Sensor Input
S
+
1.25”
3.175 cm TYP
Waterproof strain reliefs for power outputs (12 Vdc & 24 Vdc). Remove cover to access terminal blocks.
3 Conductor power cord, supplied (may be replaced with suitable wiring)
Remove the 4 screws to access mounting holes. Holes are on
4.330” centers.
2.92”
7.42 cm
100 mA Max
EX800/EX100 Series
Magmeter
+
-
+
(N/C)
(N/C)
-
0.75”
1.91 cm
Power Input
Pulse Output
Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA
(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com
Loading...
+ 2 hidden pages