MJ-Series meters use the multi-jet principle, which has been an
internationally-accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in low-quality water. Seametrics
oers cold or hot water models. The impeller is centered in a ring of jets,
with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the pointers is replaced by a magnet, which is detected by an encapsulated sensor attached to the outside of the lens. Pulse rate is determined by the dial on which the magnet is placed, and by the number of sensors (single or double).
Changing the pulse rate requires no special tools and can be done in the eld. Mechanically, all MJ-Series meters are the same. The dierence among *MJE/ MJHE, *MJR/MJHR and *MJT/MJHT meters is in the sensor. MJE/MJHE meters use a solid-state, long-lasting Hall-eect sensor, which requires power. It is
suited for use with Seametrics controls and metering pumps (LMI for instance)
that have sensor power. MJR/MJHR meters use a two-wire reed switch. They provide a dry contact closure and do not require power. MJT/MJHT meters
totalize only and do not have a sensor.
*Note on Nomenclature: Meter names that include “H” are hot water models. Without the “H” = cold water models.
C
C
o
o
d
d
m
m
e
e
i
i
p
p
i
i
a
a
t
t
n
n
r
r
e
e
y
y
C
C
ISO
ISO
9001
9001
253.872.0284 seametrics.com
253.872.0284 seametrics.com
MJ/MJH-SERIES
MJ/MJH-SERIES
MJ/MJH-SERIES
MJ/MJH-SERIES
PULSE METER
PULSE METER
PULSE METER
PULSE METER
FEATURES
Available in cold or hot water models
Either MJE/MJHE or MJR/MJHR sensor
fastens to lens without removing top
Calibration plug seal wire for tamper evidence
Cast bronze body
Union end couplings for easy service
SPECIFICATIONS*
Power
Temperature Model
Pressure
Materials
Accuracy
Pulse Output
Cable Length
Flow Rates (GPM)
6 mA at 12 Vdc (MJE/MJHE only)
Cold water 105˚ F (40˚ C) max
Hot Water 194˚ F (90˚ C) max
150 psi operating
Body Cast bronze, epoxy powder coated inside and out
Internals Engineered thermoplastic
Magnet Alnico
+/- 1.5% of reading
MJE/MJHE MJR/MJHR MJT/MJHT
Sensor Hall-eect device Reed switch Totalizer only
Max Current 20 mA+ 20mA n/a
Max Voltage 24 Vdc 24 Vdc or Vac n/a
12’ (4 m) standard (2000’ maximum run)
3/4” 1” 1-1/2” 2”
Minimum 0.22 0.44 0.88 1.98
Maximum 22 52 88 132
*Specications subject to change • Please consult our website for current data (www.seametrics.com).
253.872.0284 Page 2 seametrics.com
MJ/MJH-SERIES
20 15 10
5 0
2.5 5 7.5 10
12.5
15
17.5
20
22.5
25
5101520253035404550
10 20 30 40 50 60 70 80 90 100
3/4"
13 26 39 52 65 78 91 104117 130
1"
1
-1/2"
2"
MJ/MJH-SERIES
PULSE METER
PULSE METER
DIMENSIONS
C
A (body) B (w/couplings) C (IPS thread) D (NPT thread)
D
A
B
3/4” 1” 1-1/2” 2”
7-1/2” 10-1/4” 11-3/4” 11-3/4”
11-5/8” 15” 17” 17-5/8”
1” 1-1/4” 2” 2-1/2”
3/4” 1” 1-1/2” 2”
PULSE RATES
3/4” 1” 1 1/2” 2”
Pulses per Gallon
Gallons per Pulse
Cubic Feet per Pulse
Pulses per Cubic Meter
Liters per Pulse
*MJR/MJHR dual reed switch meters only †MJR/MJHR single reed switch meters only
20*
10
4†
2*
1
1
5*
10
50*
100
1
5*
10
1
10
100
1
10
100
4†
2*
1
1
5*
10
50*
100
1
5*
10
1
10
100
1
10
100
4†
2*
1
1
5*
10
50*
100
1
5*
10
1
10
100
1
10
100
4†
2*
1
1
5*
10
50*
100
1
5*
10
1
10
100
1
10
100
PRESSURE DROP CURVE
Pressure drop in P.S.I.
FLOW RATES (GPM
3/4” 1” 1-1/2” 2”
Minimum 0.22 0.44 0.88 1.98
Maximum 22 52 88 132
Rate of ow in gallons per minute (GPM)
)
253.872.0284 Page 3 seametrics.com
MJ/MJH-SERIES
MJ/MJH-SERIES
PULSE METER
PULSE METER
HOW TO ORDER
MODEL SIZE PULSE RATE OPTIONS
Cold water, Reed switch = MJR Cold water, Hall-eect sensor = MJE
Cold water, Totalizer only = MJT
Hot water, Reed switch = MJHR Hot water, Hall-eect sensor = MJHE
Hot water, Totalizer only = MJHT
3/4” = -075
1” = -100
1-1/2” = -150
2” = -200
†*20 Pulse/Gal = 20P †10 Pulse/Gal = 10P *4 Pulse/Gal = 4P *2 Pulse/Gal = 2P 1 Gal/Pulse = 1G *5 Gal/Pulse = 5G 10 Gal/Pulse = 10G *50 Gal/Pulse = 50G 100 Gal/Pulse = 100G 1 CF/Pulse = 1CF *5 CF/P = 5CF 10 CF/P = 10CF 1 CM/P = 1CM 10 CM/P = 10CM 100 CM/P = 100CM
1L/P = 1L
10 L/P = 10L
100 L/P = 100L
†3/4” Only *MJR/MJHR Meters Only
LMI 4-pin pump connector = -06
Seametrics 3- pin control connector = -07
LMI 5-pin pump connector = -106
ACCESSORIES
Pulse splitter = PS40
Pulse timer = PT35
CONTACT YOUR SUPPLIER
Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA
(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com
LT-65650059r2.5 20200203
2/3/2020
Loading...