The Home Screen
FT430/440/450
Quick Start Guide
GPD
MID
The left/right keys are used to move through the menus and position the cursor during data entry. The up arrow is
used to scroll through the available values that are to be entered. For example, numerical values for K factor entry or
selection of units from the available options. The enter key (represented on the keypad by the check mark) is used to
save selected entries and in conjunction with the exit tab to move between menus screens. As one
navigates the menus, the current parameter setting is shown and instructions are displayed for how to change the
selected parameter.
Set K Factor (SET K
R UNITSET K T UNIT SET D
086238.235
PRESS TO SET NUMBER
OF PULSES RECEIVED PER
GALLON OF FLOW
SET P RESET EXIT
The Home screen displays total ow volume and ow rate. The four buttons below
the LCD display are used to access menu screens for viewing and changing setup
parameters.
Press the check mark key to enter a submenu.
)
The K factor is the number of pulses the ow
sensor provides to the FT430/440/450 for every
gallon of ow. (Note that the decimal is xed at
three places. If you only have two decimal places
for your K-factor, enter a zero for the third digit.
If unable to set K-factor, the unit is “locked”
to prevent tampering. Please contact your
distributor for assistance.)
086238.235
PRESS AND TO CHANGE
AND TO EXIT
SET P RESET EXIT
R UNITSET K T UNIT SET D
Set Rate Display (R UNIT
R UNITSET K T UNIT SET D
FLOW RAT E = GPD
PRESS TO SET UNITS
FOR DISPLAY
SET P RESET EXIT
253.872.0284 Page 1 of 2 seametrics.com
View or change the ow rate display units.
)
R UNITSET K T UNIT SET D
RATE: GALLONS / MIN
PRESS AND TO CHANGE
SET P RESET EXIT

Set Total Display Units (T UNIT)
FT430/440/450
Quick Start Guide
R UNITSET K T UNIT SET D
TOTAL = GALLONS
PRESS TO SET UNITS
FOR DISPLAY
SET P RESET EXIT
View or change the total volume display units.
Set Number of Decimal Places (SET D
R UNITSET K T UNIT SET D
000
PRESS TO CHOOSE
NUMBER OF DECIMAL PLACES
IN TOTAL DISPLAY
SET P RESET EXIT
View or change the number of decimals
displayed in the total volume display.
R UNITSET K T UNIT SET D
TOTAL: GALLONS
PRESS TO CHANGE
SET P RESET EXIT
)
R UNITSET K T UNIT SET D
PRESS TO CHANGE
SET P RESET EXIT
000
Set Pulses for Pulse Out 1 (SET P
R UNITSET K T UNIT SET D
00000.0 GALLONS
PRESS TO SET NUMBER OF
GALLONS TOTALIZED PER
PULSE SENT OUT PULSE1
SET P RESET EXIT
Exit & Save Setup (EXIT
R UNITSET K T UNIT SET D
PRESS TO EXIT MENU AND
RETURN TO FLOW DISPLAY
SET P RESET EXIT
The factory setting will show Set P which allows you to view or change the volume
of ow totalized per pulse sent to pulse out 1. The units for Set P follow the units
selected for the rate display.
(With EXIT highlighted, pressing the up arrow four times will allow Output 1 to be an alarm.
The alarm can be set to trigger on either a high or low ow condition as determined by the user.
Refer to the FT430/440/450 instruction manual for details.)
)
Return to the home screen or the previous menu if in a submenu.
(Pressing the up arrow four times while EXIT is highlighted will bring you to a secondary menu,
allowing you to set alarms, set pulse output 2, change the input and jitter lters, as well as
access protected features. Refer to the FT430/440/450 instruction manual for details.)
)
Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA
(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com
LT-14244r1.1-20160222
2/22/16