Scotsman CU1526MA-6,CU1526MW-6,CU2026MA-6,CU3030MA-6,CU3030MW-6,CU2026MW-6,CU1526,CU2026,CU3030 Installation Manual

Installation Manual for Cuber-with-bin Manuale di installazione per fabbricatore di ghiaccio a cubetti con contenitore Manual de instalación de la máquina de cubitos de hielo con recipiente Manuel d’installation des modèles de machines à glaçon à bac Installationsanleitung für Eiswürfelbereiter mit Behälter Models Modelli Modelos Modèles Modelle CU1526, CU2026, CU3030
Introduction
CU1526, CU2026, CU3030
Installation Manual
The design of this cuber is the result of years of experience and testing. Standard features include a removable bin for service and an on-off switch at the front of the cabinet for easy operational control.
Keep this manual for future reference.
This installation manual is divided into three main sections: Installation, which provides the trade person with the information needed to set up and install this product; a Use and Operation is provided for reference; and a Maintenance section is also provided for reference.
Note any Caution or Warning symbols when they appear on the product or in this manual. They indicate potential hazards.
Table of Contents
Installation: Product Specifications ............................... Page 2
Model Number Description ................................... Page 3
Water .............................................. Page 4
Bin Removal ........................................... Page 5
Plumbing Requirements ..................................... Page 6
Electrical ............................................. Page 7
Final Check List ......................................... Page 7
Initial Start Up .......................................... Page 8
Adjustments ........................................... Page 9
Use and Operation........................................ Page 10
Control Switches......................................... Page 11
Cleaning, Sanitation and Maintenance ............................. Page 12
What to do before calling for service .............................. Page 13
2007
Page 1
CU1526, CU2026, CU3030 Installation Manual
Installation: Product Specifications
Location Limitations:
The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room. Water cooled models discharge warm water into the building’s drain. Space needs to be provided for service access.
Space Limitations
Do not block air flow at the front.
Airflow is in the front left and out the front right.
Environmental Limitations
Minimum Maximum
Air temperature
Water temperature
Water pressure
o
10
C. 38oC.
o
4
C. 38oC.
1 bar 5 bar
Power supply – acceptable voltage ranges
Minimum Maximum
230 volt model 207 volts 253 volts
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed above.
Room Temp Air In
Air Flow
Warm Air Out
Product Information
The product is a self contained cuber with bin. That type of machine is designed to be free standing or it can be built in under the counter.
2007
Page 2
Model Number Description
CU1526, CU2026, CU3030
Installation Manual
Example:
CU2026MA-6A
C= cuber
U=under the counter type
20= nominal ice capacity in 10s of pounds
26= nominal width of cabinet
M=medium or full dice cube. S=small or half
dice cube. A=Condenser type. A=air cooled. W=water
cooled
-6=230 volt 50 Hz
A=Series revision code. A=first series
Note: In some areas of this manual model numbers may include only the first six characters of the model number, meaning that the cube size, condenser type and voltage differences are not critical to the information listed there.
Product Description & Electrical Requirements
Scotsman ice systems are designed and manufactured with the highest regard for safety and performance.
Scotsman assumes no liability of responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any part and/or other components not specifically approved by Scotsman.
Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to change without notice.
Dimensions wxdxh**
676 mm x 699 mm x 838 mm
676 mm x 699 mm x 838 mm
778 mm x 762 mm x 838 mm
Table notes: Small cube models have the same electrical characteristics as Medium. Series revision code omitted.
* Or HACR type circuit breakers. ** Screws thru base add 7 mm to height if not using legs. If using legs add between 150 mm to 173 mm.
Model
CU1526MA-6 230/50/1 Air 15
CU1526MW-6 230/50/1 Water 15
CU2026MA-6 230/50/1 Air 15
CU2026MW-6 230/50/1 Water 15
CU3030MA-6 230/50/1 Air 15
CU3030MW-6 230/50/1 Water 15
Electrical volts/Hz/phase
Condenser Maximum Fuse Size*
2007
Page 3
CU1526, CU2026, CU3030 Installation Manual
Water
The quality of the water supplied to the ice machine will have an impact on the time between cleanings and ultimately on the life of the product. Water can contain impurities either in suspension or in solution. Suspended solids can be filtered out. In solution or dissolved solids cannot be filtered, they must be diluted or treated. Water filters are recommended to remove suspended solids. Some filters have treatment in them for suspended solids. Check with a water treatment service for a recommendation.
RO water. This machine can be supplied with Reverse Osmosis water, but the water conductivity must be no less than 10 microSiemens/cm.
Potential for Airborne Contamination
Installing an ice machine near a source of yeast or similar material can result in the need for more frequent sanitation cleanings due to the tendency of these materials to contaminate the machine. Most water filters remove chlorine from the water supply to the machine which contributes to this situation. Testing has shown that using a filter that does not remove chlorine, such as the Scotsman Aqua Patrol, will greatly improve this situation, while the ice making process itself will remove the chlorine from the ice, resulting in no taste or odor impact. Additionally, devices intended to enhance ice machine sanitation, such as the Scotsman Aqua Bullet, can be placed in the machine to keep it cleaner between manual cleanings.
Water purge
Cube ice machines use more water than what ends up in the bin as ice. While most water is used during ice making, a portion is designed to be drained out every cycle to reduce the amount of hard water scale in the machine. That’s known as water purge, and an effective purge can increase the time between needed water system cleaning.
In addition, this product has the capability to automatically vary the amount of water purged based on the purity of the water supplied to it. The water purge rate can also be set manually. Adjustments of purge due to local water conditions are not covered by warranty.
Uncrate and Set Up
Remove the carton, and using part of the carton as a cushion, tip the unit on its back to remove the skid and attach the legs (supplied) or casters (optional).
Return the unit to an upright position.
Place the ice machine in the selected location and level it by adjusting the bin leg levelers.
This manual covers several models. The model number on the product is located in two places, on the back dataplate and on the model and serial number tag, located behind the front panel. See the illustration for the dataplate and serial tag locations.
2007
Page 4
Bin Removal
CU1526, CU2026, CU3030
Installation Manual
The ice storage bin is removable to allow access to the refrigeration system for service.
Note: It is not necessary to remove the bin to start or operate the machine.
1. Remove front louvers.
2. If the machine is in an ice making mode, push and release the Manual Harvest button to release any ice that might be on the evaporator.
3. Push and hold the controller's Off button to shut the machine off.
4. Remove all ice from the bin.
5. Disconnect the drain tube from the bin drain fitting.
7. Remove two bolts from the back wall of the bin.
CU1526 or CU2026 - bolts are both under
the reservoir CU3030 - one bolt is under the reservoir, the
other is in the upper right corner.
6. Remove two bolts from the bottom of the bin, one on the left and one on the right.
8. Pull the bin forward and off the chassis.
August 2006
Page 5
CU1526, CU2026, CU3030 Installation Manual
Plumbing Requirements
All models require connection to cold, potable water. A hand actuated valve within site of the machine is required. A 3/4 GAS BSPP inlet water adapter and copper washer ship in the bin. Use them to connect to the 3/8" male flare connection at the back of the cabinet.
Water cooled models have a 1/2" FPT drain fitting plus a 3/8” FPT condenser inlet water connection.
Water Filters
If connecting to water filtration, filter only the water to the reservoir, not to the condenser. Install a new filter cartridge.
All models require drain tubing to be attached to them. Air cooled models have a single ¾” FPT drain fitting in the back of the cabinet. Water cooled models have the same fitting plus an additional ½” FPT drain fitting in the back of the cabinet.
Install new tubing when replacing a prior ice machine, as the tubing will have been sized for the old model and might not be correct for this one.
Warning: Connect only to potable water.
2. Connect drain tubing to drain fittings.
3. Route the drain tubing to building drain. Follow local codes for air gap.
Drain Tubing:
Use rigid drain tubes and route them separately – do not Tee into the bin’s drain and, if water cooled, do not Tee the condenser drain into the reservoir or bin drain.
Vent the reservoir drain. A vertical vent at the back of the drain, extended about 200 mm will allow the gravity drain to empty and also keep any surges during draining from discharging water out the vent..
Horizontal runs of drain tubing needa6mmfall per meter of run for proper draining.
Follow all applicable codes.
1. Connect water supply to water inlet fittings. Install new tubing when replacing a prior ice machine.
Water Filter (if used)
Water Inlet
Shut off valve
Drain
Tubing
Floor Drain
Water Cooled
Supply Location
Bin Drain
Connection
Potable
Water
Connection
Water Cooled
Drain Location
Air Cooled Model Plumbing Connections
Water Cooled Plumbing Connections
2007
Page 6
Electrical
The machine is supplied with a power cord, and only requires the addition of a plug. Connect the plug to the power cord in compliance with the local electrical codes. Select an appropriately certified plug based on the country of use, current rating of the appliance and suitability for use with 1.5 mm2 x 3 conductor type H05VV-F cord.
This is a cord-connected unit, and must be connected to a separate power supply. Check the dataplate for the voltage, ampacity and maximum fuse size and per the dataplate use fuses or HACR circuit breakers.
Note: In case the power cord is damaged, it must be replaced by a like cord. Replacement cords are available from Scotsman's local representative. Replacement should only be done by a qualified technician to prevent possible risks.
CU1526, CU2026, CU3030
Installation Manual
Follow All Local Codes - This Unit Must Be Grounded. Do not use extension cords and do not disable or by-pass ground prong on electrical plug.
The power cord plug will be the disconnect means for this machine.
Final Check List
After connections,
1. Wash out the bin. If desired, the interior of the bin could be sanitized.
2. Locate the ice scoop (if supplied) and have it available for use when needed.
Final Check List:
1. Is the unit located indoors in a controlled environment?
2. Is the unit located where it can receive adequate cooling air?
3. Has the correct electrical power been supplied to the machine?
4. Have all the water supply connections been made?
5. Have all the drain connections been made?
6. Has the unit been leveled?
7. Have all unpacking materials and tape been removed?
8. Is the water pressure adequate?
9. Have the drain connections been checked for leaks?
10. Has the bin interior been wiped clean or sanitized?
11. Have any water filter cartridges been replaced?
12. Have all required kits and adapters been properly installed?
2007
Page 7
CU1526, CU2026, CU3030
Manual Harvest
Clean
Code
Display
Component Operation Indicator Lights
Code Description
.... ......FreezeCycle
flashes....FreezeCycleisPending
.... ......HarvestCycle
flashes....ManualHarvest
.... ......BinisFull
.... ......CleanCycle
.... ......BoardLocked
.... ......TestMode
.... ......Off
.... ......SelfTestFailed
flashes....MaxFreeze-Retrying
..... ......MaxFreezeTimeShutDown
flashes....MaxHarvest-Retrying
.... ......MaxHarvestTimeShutDown
.... ......SlowWaterFill
.... ......HighDischarge Temp
.... ......SumpTempSensorFailure
.... ......DischargeTempSensorFailure
flashes...ShortFreeze-Retrying
Short Freeze - Thin ice
- Unit Remotely
Locked Out - Contact Leasing Company
F F H H b C L d O E 1 1 2 2 3 4 5 7 8
8............
All 4Upper Lights Flashing
Control Operation - See Manual
Water LightOn
De-Scale LightOn
Flush Setting
TestMode
Recall DiagnosticCodes
Reset fromCode 1, 2,4 or 8
- Restore water supply to
machine.
- Clean and sanitize
machine.
- ToChange: Depress Off for 3 seconds. Press On to select purge (1-5) setting or Afor Automatic.
- Depress Off for 3 seconds,
then depress Clean for 3 seconds.
- Depress Off for 3 seconds. Press Harvest repeatedly to go from most recent to oldest of 10.
- Depress
Off then Depress On.
TechnicianSection
02-4302-01
On Off
Power
Status
De-scaleWater
Sanitize
Installation Manual
Initial Start Up
1. Remove left front louver. Check machine for any packing or wires rubbing moving parts. Note location of control board at the left.
2. Switch the on-off switch to On.
3. Switch on the electrical power to the machine. Observe that some of the control’s indicator lights glow and its display shows O.
4. Open the water supply valve.
5. Push and release the ON button. The code display will begin to blink F.
The purge valve opens and the water pump starts. In a few seconds the purge valve closes and the water pump stops. Water will flow into the machine until the reservoir is full. The hot gas valve and harvest assist device will activate, then the compressor and water pump will start. If it’s an air cooled model the fan(s) motors will begin to turn a few moments after the compressor starts. The display will show a continuous F. Five seconds later the hot gas valve will close and the harvest assist device will return to its standby position. Warm air will be discharged from air cooled models.
The display shows an H. The hot gas valve opens, the air cooled fan motor(s) shut off and the harvest assist mechanism is activated. The purge valve opens to drain some water, when it does the float valve opens to refill the reservoir. After a few seconds the purge valve closes but the float valve continues to fill the reservoir. Harvest continues until the ice is released as a unit and forces the curtain to open. When the curtain opens it signals the controller which returns the unit to a freeze cycle.
9. Check the ice harvested for proper bridge thickness. The ice bridge is factory set at 1/8 inch. If needed, adjust bridge thickness. Do NOT make it too thin.
10. Return the louver to its normal position and secure it to the machine.
11. Instruct the user in the operation of the machine and its maintenance requirements.
12. Fill out and mail the warranty registration form.
Write the day, month and year of initial start up here:
_______________________________________
Typical Ice Making Cycle Times (minutes).
Listed times are for clean machines in proper installations. Cycle length at startup will be longer until the system stabilizes.
6. Observe the Ready for Harvest indicator light. It may blink early in the cycle, that is normal. The control will ignore that signal for the first 6 minutes of freeze.
7. During the Freeze cycle move the curtain and observe that the SW1 or SW2 light on the control board blinks On when the curtain moves away from the evaporator and Off when returned to its normal position.
Note: Moving the curtain during the Freeze cycle has no affect on control function, but will cause water to flow into the cube chute.
8. When enough ice has frozen, the Ready for Harvest indicator light will be on steady. After it’s been on steady for a few seconds Harvest will begin.
o
21
Model
C air /
o
10
C. water CU1526A 22-25 36-29 CU1526W 21-24 28-31 CU2026A 15-18 25-28 CU2026W 15-18 20-23 CU3030A 12-15 19-22 CU3030W 10-13 15-18
2007
Page 8
32 21
o
o
F. air / F. water
Adjustments
Bridge Thickness - For the Service Tech Only
1. Remove left louver, locate controller on and off switches.
2. Push and hold Off till the machine stops.
3. Remove curtain.
4. Use a hex wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness. Rotate CCW to decrease bridge thickness.
CU1526, CU2026, CU3030
Installation Manual
3-4mm
bridge
Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness adjustments are not covered by warranty.
5. Return curtain and louver to their normal positions.
6. Push and release the On button. Check next harvest of ice. Repeat steps 1-6 if needed.
Water Purge Setting
The water purge is factory set to the automatic position, suitable for most water conditions. The setting can be changed to one of 5 manual settings or left on automatic.
Purge setting
Water Type
1 - Minimum
RO water or equivalent
2­Moderate
Low TDS non-RO water
3­Standard
Use for typical water
Too Big
Just Right
Too Small
Ice Bridge Thickness Measurement
Adjustment Screw
Bridge Thickness Adjustment Mechanism
4 - Heavy 5 - Maximum A - Automatic
Any with High TDS water
Very High TDS water
conductivity not
less than 10
microSiemens/cm
To set:
1. Switch the machine OFF by holding the Off button in until a number or the letter A shows on the display.
2. Press and release the On button repeatedly until the number on the display corresponds to the desired setting.
3. Press and release the Off switch again to return to the normal control state.
Note: Water cooled models, the refrigeration system discharge pressure is factory set at 245 PSIG or 1700 kPa (gauge) or 17 Bar, which should yield a freeze cycle discharge water temperature of about 50 - 43 degrees C. Adjust if necessary.
2007
Page 9
CU1526, CU2026, CU3030 Installation Manual
Use and Operation
Once started, the ice machine will automatically make ice until the bin is full of ice. When ice level drops, the ice machine will resume making ice.
There are four indicator lights at the front of the control box that provide information on the condition of the machine.
Indicator Lights:
Power
Status
Water
De-scale & Sanitize
Indicator Lights & Their Meanings
Power Status Water De-Scale & Sanitize
Steady Green Normal Normal – bin full or making ice - -
Blinking Green
Blinking Red -
Yellow - - -
Blinking Yellow
Light off No power Switched off Normal Normal All Blinking Unit remotely locked out – check with leasing company
If the Water light is on, the machine has sensed a lack of water. Check the water supply to the machine. The water could have been shut off or the water filter cartridges might need to be changed.
If the De-Scale light is on, the machine has determined that it needs to be cleaned. Contact an authorized Scotsman service agent and have the machine cleaned, de-scaled and sanitized.
Self Test Failure
- - - In Cleaning mode
Switching on or off - -
Diagnostic shutdown or, if making ice, temperature sensor failure
Note: A Component Indicator Light switches ON to indicate that the component is operating.
Note: There are two Curtain Switch lights, SW1 and SW2. These single plate models have one curtain switch light on all the time, as a curtain switch light is ON when a curtain is either open or not present.
Lack of water
-
Time to de-scale and sanitize
2007
Page 10
Control Switches
On Off
Power
Status
De-scaleWater
Sanitize
CU1526, CU2026, CU3030
Installation Manual
There is a front on and off switch, located in the top center of the louvers. Switching this switch Off will immediately stop the machine. Switching it back on will cause the machine to start in a timed harvest cycle.
The controller also has on and off switches, which can also switch the machine on and off, but their operation is different:
To switch the machine OFF, push and release the Off button. The machine will shut off at the end of the next cycle. To shut the machine off immediately, push and hold the Off button for 3 seconds.
To switch the machine ON, push and release the On button. The machine will go through a start up process and then resume ice making.
Ice
The cuber drops ice in large sections. That ice will break up into random parts as it falls into the bin, but some large sections may remain on top of the ice in the bin. When removing ice, tap the groups of ice with an ice scoop to separate them into smaller units.
Using the ice will help to level it out and allow the machine to fill it to its maximum level.
Heat
Air cooled models will generate heat when in operation. That heat is discharged out the front of the cabinet.
Noise
The ice machine will make noise when it is in ice making mode. The compressor, fan motor(s) if air cooled and water pump all produce some sound. It is also normal to hear some cracking just before the harvest cycle begins. In addition, during the harvest cycle the harvest assist solenoid will click twice as it pushes the ice out and returns to its normal position. The ice harvests as a unit or slab, which makes some noise when it impacts the bin. These noises are all normal for this machine.
2007
Page 11
CU1526, CU2026, CU3030 Installation Manual
Cleaning, Sanitation and Maintenance
This ice system requires three types of maintenance:
Remove the build up of mineral scale from the ice machine’s water system and sensors.
Sanitize the ice machine’s water system and the ice storage bin.
Clean or replace the air filter and clean the air cooled condenser (air cooled models only).
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition.
Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine is cleaned and sanitized.
The ice machine’s water system should be cleaned and sanitized a minimum of twice per year.
Air cooled condenser filter
1. Remove filter from left front grill.
2. Wash the dust and dirt from the filter.
3. Return it to its original position.
Do not operate the machine without the filter in place except during cleaning.
Air cooled condenser
If the machine has been operated without a filter the air cooled condenser fins will need to be cleaned.
They are located under the fan blades. The services of a refrigeration technician will be required to clean the condenser.
Exterior Panels
The front and side panels are durable stainless steel. Fingerprints, dust and grease will require cleaning with a good quality stainless steel cleaner.
Water filters
If the machine has been connected to water filters, check the cartridges for the date they were replaced or for the pressure on the gauge. Change cartridges if they’ve been installed more than 6 months or if the pressure drops too much when the ice machine fills with water.
2007
Page 12
What to do before calling for service
Reasons the machine might shut itself off:
Lack of water.
Freeze cycle takes too long.
Harvest cycle takes too long.
High discharge temperature.
Controller self test failure.
Check the following:
1. Has the water supply to the ice machine or
building been shut off? If yes, the ice machine will automatically restart within 25 minutes after water begins to flow to it.
2. Has power been shut off to the ice machine? If
yes, the ice machine will automatically restart when power is restored.
CU1526, CU2026, CU3030
Installation Manual
3. Has someone shut the water off to a water
cooled unit? If yes, after the water supply has been restored the ice machine may need to be manually reset.
4. Is the curtain open because some ice is stuck
under it? If so, remove the ice and the machine should start in a few minutes.
Note: Curtain can be removed & replaced anytime the machine is in a standby mode or when it is in a freeze cycle. However, removal of the curtain during freeze will result in water flowing into the bin. Removal of the curtain during harvest terminates harvest at that point and, if left off, will result in the machine shutting off.
To Manually Reset the machine.
Push and release the Off button.
Push and release the On button.
To Shut the Machine Off:
1. Push and hold the Off button for 3 seconds or
until the machine stops.
2007
Page 13
Power
Status
De-scaleWater
Sanitize
On Off
Technician Section
Manual
Harvest
Control Operation - See Manual
Water Light On
machine.
De-Scale Light On
machine.
Flush Setting
for 3 seconds. Press On to select purge (1-5) setting or A for Automatic.
Test Mode
then depress Clean for 3 seconds.
Recall Diagnostic Codes
for 3 seconds. Press Harvest repeatedly to go from most recent to oldest of 10.
Reset from Code 1, 2, 4 or 8
Off then Depress On.
Clean
Code
Display
- Restore water supply to
- Clean and sanitize
- To Change: Depress Off
- Depress Off for 3 seconds,
- Depress Off
- Depress
Component Operation Indicator Lights
Code Description
F
.... ......Freeze Cycle
F
flashes....Freeze Cycle is Pending
H
.... ......Harvest Cycle
H
flashes....Manual Harvest
b
.... ......BinisFull
C
.... ......Clean Cycle
L
.... ......Board Locked
d
.... ......TestMode
O
.... ......Off
E
.... ......Self Test Failed
1
flashes....MaxFreeze - Retrying
1
..... ......MaxFreeze Time Shut Down
2
flashes....MaxHarvest - Retrying
2
.... ......MaxHarvest Time Shut Down
3
.... ......Slow Water Fill
4
.... ......High Discharge Temp
5
.... ......Sump Temp Sensor Failure
7
.... ......Discharge Temp Sensor Failure
8
flashes . . . Short Freeze - Retrying
8............
All 4 Upper Lights Flashing
Locked Out - Contact Leasing Company
Short Freeze - Thin ice
- Unit Remotely
02-4302-01
Manuale dell’utente per fabbricatore di ghiaccio a cubetti con contenitore, Modelli CU1526, CU2026 e CU3030
Modelli CU1526, CU2026, CU3030
Introduzione
Il design di questo fabbricatore di ghiaccio a cubetti è il risultato di anni di esperienza e collaudi. Le caratteristiche standard includono un contenitore asportabile per l’assistenza e un interruttore di accensione-spegnimento situato nella parte anteriore del mobile per un comodo accesso operativo.
Conservare il presente manuale come riferimento futuro.
Questo manuale di installazione è suddiviso in tre sezioni principali: Installazione, che fornisce al rappresentante di vendita le informazioni necessarie per posizionare e installare questo prodotto; Uso e Funzionamento, che fornisce all’utente le informazioni necessarie per utilizzare il prodotto; Manutenzione, che fornisce all’utente le informazioni necessarie per preservare il corretto funzionamento dell’apparecchio.
Osservare scrupolosamente le informazioni contraddistinte dai simboli di attenzione o avvertenza riportate sul prodotto o in questo manuale. Tali informazioni indicano potenziali pericoli.
2007
Pagina 1
Manuale di installazione
CU1526, CU2026, CU3030
Sommario
Installazione: Specifiche tecniche ................................ Pagina 2
Descrizione del codice modello ................................. Pagina 3
Acqua .............................................. Pagina 4
Rimozione del contenitore .................................... Pagina 5
Requisiti idraulici......................................... Pagina 6
Collegamenti elettrici ...................................... Pagina 7
Controllo finale.......................................... Pagina 7
Accensione iniziale ....................................... Pagina 8
Regolazioni ........................................... Pagina 9
Uso e Funzionamento ......................................Pagina 10
Interruttori di controllo ......................................Pagina 11
Pulizia, igienizzazione e manutenzione .............................Pagina 12
Operazioni da svolgere prima di rivolgersi all’assistenza ....................Pagina 13
Installazione: specifiche tecniche
Limitazioni per il posizionamento:
Il prodotto è concepito per essere installato in ambienti interni e controllati. I modelli raffreddati ad aria scaricano aria estremamente calda nell’ambiente di installazione. I modelli raffreddati ad acqua scaricano acqua calda nelle condotte di scarico dell’edificio. È necessario lasciare un adeguato spazio per consentire l’accesso di servizio.
Limitazioni di spazio
Non bloccare il flusso d’aria nella parte anteriore.
Il flusso d’aria entra dalla parte anteriore sinistra ed esce dalla parte anteriore destra.
Limitazioni ambientali
Minima Massima
Temperatura dell’aria
10 oC 38 oC
Temperatura dell’acqua
4 oC 38 oC
Pressione dell’acqua
1 bar 5 bar
Alimentazione – intervalli di tensione consentiti
Minimo Massimo
Modello a 230 volt
207 volt 253 volt
Informazioni sulla garanzia
Il certificato di garanzia per questo prodotto viene fornito separatamente dal presente manuale. Fare riferimento al certificato di garanzia per informazioni sulla copertura applicabile. In generale, la garanzia copre difetti di materiali o lavorazione. La garanzia non copre la manutenzione, le correzioni all’installazione o le situazioni in cui la macchina viene utilizzata in circostanze che eccedono le limitazioni precedentemente indicate.
Informazioni sul prodotto
Il prodotto è un fabbricatore di ghiaccio a cubetti
con contenitore. Il tipo di macchina in questione è concepita per essere autonoma o incassata.
2007
Pagina 2
Manuale di installazione CU1526, CU2026, CU3030
Flusso dell’aria
Ingresso aria a temperatura
Uscita aria calda
Descrizione del codice modello
Esempio:
CU2026MA-6A
C= cuber (fabbricatore di ghiaccio a cubetti)
U=under the counter type (tipo incassato
sotto il bancone)
20= capacità produttiva di ghiaccio in
decine di libbre
26= larghezza nominale dell’involucro
esterno
M= cubetti di dimensioni medie o full dice.
S= cubetti di dimensioni piccole o half dice.
A=tipo condensatore. A=raffreddato ad aria.
W=raffreddato ad acqua
-6=230 Volt 50 Hz
A=Codice versione serie. A=prima serie
Nota: in alcune parti del presente manuale i codici modello potrebbero includere esclusivamente i primi sei caratteri del codice completo, indicando così che le differenze relative a dimensioni cubetti, tipo condensatore e tensione non risultano fondamentali per le informazioni riportate.
Descrizione del prodotto e requisiti elettrici
I sistemi per ghiaccio Scotsman sono progettati e prodotti con la massima attenzione alla sicurezza e alle prestazioni.
Scotsman non si assume responsabilità di alcun tipo relative ai propri prodotti, in qualsiasi modo modificati, incluso l’uso in abbinamento a parti e/o altri componenti non specificamente approvati da Scotsman.
Scotsman si riserva il diritto di apportare miglioramenti e/o modifiche al design in qualsiasi momento. Le specifiche e il design sono soggetti a modifiche senza preavviso.
2007
Pagina 3
Manuale di installazione
CU1526, CU2026, CU3030
Dimensioni l x p x a**
Modello
Spec. elettriche
Volt/Hz/fasi
Condensatore
Portata massima fusibile *
676 mm x 699 mm x 838 mm
CU1526MA-6 230/50/1 Aria
15
CU1526MW-6 230/50/1 Acqua
15
676 mm x 699 mm x 838 mm
CU2026MA-6 230/50/1 Aria
15
CU2026MW-6 230/50/1 Acqua
15
778 mm x 762 mm x 838 mm
CU3030MA-6 230/50/1 Aria
15
CU3030MW-6 230/50/1 Acqua
15
Table notes: i modelli per cubetti piccoli hanno le stesse caratteristiche elettriche dei modelli per cubetti medi. Codice versione serie omesso.
* O interruttori di circuito di tipo HACR. ** Per le viti tramite la base aggiungere 7 mm all’altezza se non si utilizzano i piedini. Se si utilizzano i piedini aggiungere tra 150 e 173 mm.
Acqua
La qualità dell’acqua erogata alla macchina del ghiaccio avrà impatto sugli intervalli di pulizia e, a lungo termine, sulla durata operativa del prodotto. L’acqua può contenere impurità in sospensione o in soluzione. Le impurità solide in sospensione possono essere filtrate. Le impurità in soluzione o dissolte non possono essere filtrate, ma devono essere diluite o trattate. Si consiglia di utilizzare filtri per l’acqua e di rimuovere le impurità solide in sospensione. Alcuni filtri sono dotati di sistemi di trattamento interno per le impurità solide in sospensione. Per informazioni, rivolgersi a un’azienda per il trattamento dell’acqua.
Acqua a osmosi inversa. Questa macchina può utilizzare acqua a osmosi inversa, tuttavia la conduttività dell’acqua non deve essere inferiore a 10 microSiemens/cm.
Potenziale contaminazione tramite aria
Se si installa la macchina per ghiaccio in prossimità di un apparecchio per la produzione di fermenti o sostanze simili, può essere necessario ricorrere a interventi di pulizia sanitaria più frequenti, a causa della tendenza di tali sostanze a contaminare la macchina. La maggior parte dei filtri per acqua rimuove il cloro dall’acqua erogata alla macchina, accentuando la possibilità di contaminazione. Studi hanno dimostrato che se si utilizza un filtro che non rimuove il cloro, come Aqua Patrol di Scotsman, si migliora sensibilmente la situazione, mentre lo stesso processo di formazione del ghiaccio rimuove il cloro dal ghiaccio, con il risultato di nessun impatto sull’odore o il gusto del ghiaccio. Inoltre, è possibile installare nella macchina prodotti per migliorare l’igiene, come Aqua Bullet di Scotsman, che migliorano la pulizia della macchina tra gli interventi di pulizia manuale.
Questo manuale è applicabile a diversi modelli. Il codice modello del prodotto viene riportato in due posizioni, sulla targhetta delle caratteristiche posteriore e sulla targa del codice di serie e del modello, situata al di sotto del pannello anteriore. Per le posizioni della targhetta delle caratteristiche e della targa con il codice di serie, vedere l’illustrazione.
Scarico dell’acqua
Le macchine per la fabbricazione di cubetti di ghiaccio utilizzano più acqua di quella raccolta nel contenitore sotto forma di ghiaccio. La maggior parte dell’acqua viene utilizzata per la produzione del ghiaccio, tuttavia, una parte viene scaricata a ogni ciclo per ridurre la percentuale di acqua dura all’interno della macchina. Questo processo è denominato scarico dell’acqua e ha il beneficio di aumentare gli intervalli temporali degli interventi di pulizia del sistema idraulico.
Inoltre, questo prodotto ha la capacità di variare automaticamente la quantità di acqua scaricata, in base all’acqua che viene erogata alla macchina. È inoltre possibile impostare manualmente la percentuale di acqua scaricata. Le regolazioni dello scarico, legate alle caratteristiche locali dell’acqua, non sono coperte dalla garanzia.
Disimballaggio e installazione
Rimuovere il cartone e, utilizzando parte del cartone come appoggio, coricare il contenitore sulla parte posteriore per rimuovere il basamento in legno e fissare i piedini (in dotazione) o le ruote (opzionali).
Riportare l’unità in posizione verticale.
Posizionare la macchina del ghiaccio nella sede prescelta e livellarla regolando i livellatori dei piedini del contenitore.
2007
Pagina 4
Manuale di installazione CU1526, CU2026, CU3030
Rimozione del contenitore
Il contenitore di raccolta del ghiaccio è asportabile per consentire l’accesso al sistema di refrigerazione per l’assistenza.
Nota: non è necessario rimuovere il contenitore per avviare o azionare la macchina.
1. Rimuovere le persiane anteriori.
2. Se la macchina è in modalità di produzione ghiaccio, premere e rilasciare il pulsante dello sbrinamento manuale per rilasciare l’eventuale ghiaccio presente nell’evaporatore.
3. Tenere premuto il pulsante Off del controller per spegnere la macchina.
4. Rimuovere il ghiaccio dal contenitore.
5. Scollegare il tubo di scarico dal raccordo di scarico del contenitore.
6. Rimuovere i due bulloni dalla parte posteriore del contenitore, a destra e a sinistra.
7. Rimuovere i due bulloni dalla parete posteriore del contenitore.
CU1526 o CU2026 - entrambi i bulloni
si trovano sotto il serbatoio
CU3030 - un bullone si trova sotto il
serbatoio, mentre l’altro si trova nell’angolo in alto a destra.
8. Tirare il contenitore in avanti estraendolo dal telaio.
2007
Pagina 5
Manuale di installazione
CU1526, CU2026, CU3030
Requisiti idraulici
Tutti i modelli richiedono il collegamento ad acqua potabile e fredda. È richiesto un rubinetto in prossimità del luogo di installazione della macchina. Al contenitore sono acclusi un adattatore per l’acqua in entrata da 3/4 GAS BSPP e una rondella in rame. Utilizzarli per connettere la connessione maschio svasata da 3/8" nella parte posteriore dell’armadietto.
I modelli raffreddati ad acqua sono dotati di un raccordo di scarico da 1/2" FPT, oltre a un raccordo di ingresso dell’acqua per il condensatore da 3/8" FPT.
Filtri dell’acqua
Se si utilizzano sistemi di filtraggio dell’acqua, è necessario filtrare solo l’acqua diretta al serbatoio, non quella diretta al condensatore. Installare una nuova cartuccia per il filtro.
Tutti i modelli richiedono l’applicazione di tubi di scarico. I modelli raffreddati ad aria sono dotati di un unico raccordo di scarico da ¾" FPT, sulla parte posteriore della macchina. I modelli raffreddati ad acqua sono dotati dello stesso raccordo, oltre un ulteriore raccordo di scarico da ½" FPT, sulla parte posteriore della macchina.
Se si sostituisce una precedente macchina del ghiaccio, installare nuovi tubi, in quanto i tubi preesistenti potrebbero non essere adatti per questa macchina.
1. Collegare l’erogazione dell’acqua ai raccordi di ingresso dell’acqua. Installare nuovi tubi quando si sostituisce una macchina per il ghiaccio preesistente.
Avvertenza: connettere solo ad acqua potabile.
2. Collegare i tubi di scarico ai raccordi di scarico.
3. Collegare i tubi di scarico allo scarico dell’edificio. Osservare le norme locali relative al gioco per i tubi.
Tubi di scarico:
Utilizzare tubi di scarico rigidi e instradarli separatamente – non collegarli tramite raccordo a T allo scarico del contenitore e, se il modello è raffreddato ad acqua, non collegare lo scarico del condensatore allo scarico della vaschetta o del contenitore.
Lo scarico della vaschetta deve essere di tipo ventilato. Prevedere un tubo di areazione verticale, sulla parte superiore dello scarico della lunghezza di 200 mm, per consentire all’acqua di defluire correttamente.
Per il corretto scarico, è necessario un tubo di sfogo verticale di 6 mm di lunghezza per ogni metro di tubazione orizzontale.
Osservare tutta la normativa applicabile.
2007
Pagina 6
Manuale di installazione CU1526, CU2026, CU3030
Collegamenti idraulici del modello
raffreddato ad aria
Ingresso dell’acqua
Tubi di
scarico
Scarico a terra
Filtro dell’acqua (se utilizzato)
Valvola di arresto
Collegamenti idraulici
raffreddamento ad acqua
Posizione dello
scarico
dell’acqua
Collegamento
acqua potabile
Posizione
dell’erogazione
Collegamento
scarico
Collegamenti elettrici
La macchina è dotata di cavo di alimentazione e occorre semplicemente aggiungere una presa. Collegare la presa al cavo di alimentazione rispettando le normative elettriche locali. Selezionare una presa appositamente certificata per il paese in cui sarà utilizzata, la portata nominale della corrente dell’apparecchiatura e l’adeguatezza all’utilizzo con un cavo H05VV-F conduttore 1,5 mm2 x 3.
Si tratta di un’unità connessa con cavo e va collegata a una fonte di alimentazione separata. Controllare la tensione sulla targhetta di identificazione, la portata e la dimensione massima del circuito e in base ai dati riportati sulla targhetta utilizzare fusibili o interruttori di circuito HACR.
Nota: nel caso in cui il cavo di alimentazione sia danneggiato, sostituirlo con uno simile. I cavi sostitutivi sono reperibili presso i rappresentanti locali Scotsman. Per prevenire i possibili rischi far eseguire la sostituzione a un tecnico qualificato.
Seguire tutte le normative locali - L’unità deve essere messa a terra. Non utilizzare prolunghe, né disattivare o bypassare il polo di terra della presa elettrica.
La spina del cavo di alimentazione costituirà il metodo di scollegamento di questa macchina.
Controllo finale
Dopo aver eseguito i collegamenti:
1. Lavare il contenitore. Se si desidera, è possibile igienizzare la parte interna del contenitore.
2. Individuare la paletta di prelievo (se fornita) e prepararla per l’uso secondo le esigenze.
Controllo finale:
1. L’unità è stata installata in un ambiente interno e controllato?
2. L’unità è stata installata in una posizione che consente l’ingresso di aria adeguata per il raffreddamento?
3. L’alimentazione elettrica viene erogata alla macchina?
4. I collegamenti idraulici sono stati eseguiti correttamente?
5. Tutti i collegamenti di scarico sono stati eseguiti correttamente?
6. L’unità è stata livellata correttamente?
7. Tutti i materiali di imballaggio e il nastro sono stati rimossi?
8. La pressione dell’acqua è adeguata?
9. È stata controllata l’eventuale presenza di perdite dai collegamenti di scarico?
10. L’interno del contenitore è stato pulito o igienizzato?
11. Le eventuali cartucce precedentemente utilizzate dei filtri dell’acqua sono state sostituite?
12. Tutti i componenti e gli adattatori necessari sono stati correttamente installati?
2007
Pagina 7
Manuale di installazione
CU1526, CU2026, CU3030
Accensione iniziale
1. Rimuovere le persiane anteriori sinistre. Controllare di aver rimosso tutti gli imballaggi e che non ci siano parti in movimento o che facciano attrito con i cavi. Individuare la posizione del pannello di controllo a sinistra.
2. Portare l’interruttore di
accensione-spegmimento su On.
3. Collegare
l’alimentazione elettrica alla macchina. Alcune spie luminose sul pannello di controllo si accendono e sul display viene visualizzato O.
4. Aprire il rubinetto di erogazione dell’acqua.
5. Premere e rilasciare il pulsante ON. Sul display
dei codici F inizia a lampeggiare.
La valvola di spurgo si apre e la pompa dell’acqua si avvia. Dopo alcuni istanti la valvola di scarico si chiude e la pompa dell’acqua si arresta. L’acqua fluisce nella macchina fino al riempimento del serbatoio. La valvola del gas caldo e il dispositivo di assistenza al ciclo di sbrinamento si attivano, quindi partono il compressore e la pompa dell’acqua. Per i modelli raffreddati ad aria i motoventilatori iniziano a ruotare alcuni istanti dopo l’avvio del compressore. Sul display viene visualizzata costantemente una F. Dopo cinque secondi la valvola del gas caldo si chiude e il dispositivo di assistenza al ciclo di sbrinamento ritorna in posizione di standby. Per i modelli raffreddati ad aria, l’aria calda viene scaricata.
6. Osservare il Led “Pronto per lo sbrinamento”.
Potrebbe lampeggiare all’inizio del ciclo, ciò è normale e non indica un malfunzionamento. Il sistema di controllo ignorerà tale segnale per i primi 6 minuti del ciclo di congelamento.
7. Durante il ciclo di congelamento, spostare
il deflettore e osservare come la spia SW1 o SW2 sul pannello di controllo si accenda quando questo viene allontanato dall’evaporatore e si spenga quando viene riposizionato.
Nota: se si sposta il deflettore durante il ciclo di congelamento, non si produce alcun effetto sulle funzioni di controllo, tuttavia l’acqua fluisce sullo scivolo del ghiaccio.
8. Se si è formato ghiaccio sufficiente, la spia
indicatrice “Pronto per lo sbrinamento” rimane accesa costantemente. Dopo alcuni secondi che la spia rimane accesa costantemente, il ciclo di sbrinamento viene avviato.
Sul display viene visualizzata una H. La valvola del gas caldo si apre, i motoventilatori si arrestano e viene attivato il meccanismo di assistenza al ciclo di sbrinamento. La valvola di scarico si apre per eliminare l’acqua dalla vaschetta, contemporanea­mente la valvola a galleggiante si apre per riempire nuovamente il serbatoio. Dopo alcuni istanti la valvola di scarico si chiude mentre la valvola a galleggiante rimane aperta per riempire il serbatoio. Il ciclo di sbrinamento continua fino a quando la lastra di ghiaccio si stacca dall’evaporatore aprendo il deflettore. Quando il deflettore si apre, viene inviato un segnale alla scheda tale da rimettere la macchina nella fase di congelamento.
9. Controllare il ghiaccio scaricato e verificarne lo spessore. Lo spessore del ghiaccio che unisce i cubetti deve essere di circa 3 mm. Se necessario, regolare lo spessore agendo sul sensore spessore ghiaccio. NON impostare uno spessore insufficiente.
10. Rimontare la persiana e fissarla alla macchina.
11. Istruire gli utenti sul funzionamento della macchina e sui relativi requisiti di funzionamento.
12. Compilare e spedire il modulo di registrazione della garanzia.
Scrivere qui il giorno, il mese e l’anno della prima accensione della macchina:
_______________________________________
Tempi di produzione del ghiaccio standard (in minuti).
I tempi elencati si riferiscono a macchine pulite in condizioni di installazione corrette. Dopo l’avvio della macchina la durata del ciclo risulta superiore fino a quando il sistema si stabilizza.
Modello
21 oC aria / 10 oC acqua
32 oF aria /
21 oF acqua CU1526A 22-25 36-29 CU1526W 21-24 28-31 CU2026A 15-18 25-28 CU2026W 15-18 20-23 CU3030A 12-15 19-22 CU3030W 10-13 15-18
2007
Pagina 8
Manuale di installazione CU1526, CU2026, CU3030
Manual
Harvest
Clean
Code
Display
Component Operation Indicator Lights
Code Description
F . . . . .. . . . . Freeze Cycle
F flashes. . . . Freeze Cycle is Pending
H . . . . .. . . . . Harvest Cycle
H flashes. . . . Manual Harvest
b .... ......Bin is Full
C.... ......Clean Cycle
L. . . . .. . . . . Board Locked
d .... ......Test Mode
O.... ......Off
E. . . . . . . . . . Self Test Failed
1 flashes. . . . Max Freeze - Retrying
1. . . . . .. . . . . Max Freeze Time Shut Down
2 flashes. . . . Max Harvest - Retrying
2 . . . . . . . . . . Max Harvest Time Shut Down
3 . . . . . . . . . . Slow Water Fill
4 . . . . . . . . . . High Discharge Temp
5 . . . . . . . . . . Sump Temp Sensor Failure
7 . . . . . . . . . . Discharge Temp Sensor Failure
8 flashes . . . Short Freeze - Retrying
8............Short Freeze - Thin ice
All 4 Upper Lights Flashing - Unit Remotely Locked Out - Contact Leasing Company
Control Operation - See Manual
Water Light On - Restore water supply to machine. De-Scale Light On - Clean and sanitize machine. Flush Setting - To Change: Depress Off for 3 seconds. Press On to select purge (1-5) setting or A for Automatic. Test Mode - Depress Off for 3 seconds, then depress Clean for 3 seconds. Recall Diagnostic Codes - Depress Off for 3 seconds. Press Harvest repeatedly to go from most recent to oldest of 10. Reset from Code 1, 2, 4 or 8 - Depress Off then Depress On.
Technician Section
02-4302-01
On Off
Power
Status
De-scaleWater
Sanitize