A37202-002Top panel, SS
02-3823-21Top panel, plasticfor C -H
series. Will not fit A orB series.
202-3686-01Insulation
3A37197-001Back pnl - forwc A& B
A37196-001Back pnl - forac A& B
A37670-001Back pnl for ACC - H
A37669-001Back pnl for WCC - H
403-1404-37Screw
5A37199-015Rt side panel, grey,A & B
A37199-002Rt side panel, SS, A & B
A37668-001Rt side panel, C - H series
6A37194-001Right bottom channel
7A37213-001Right side support
802-3702-21Evaporator cover,incl insul
902-3701-01Cover retainer
10A37200-01524” Right front panel, grey
A37200-00224” Right front panel, SS
1115-0808-01Emblem
1202-3699-01Panel support clip
13A37262-01524” Left front panel AC - grey
A37262-00224” Left front panel, AC -SS
13a02-3485-01Air filter, for front or left side
22
7
6
9
8
5
20
13bA37326-001Filter bracket (either)
1403-1728-01Front panel screw
15A37198-015Left side pnl, no louvers grey
A37198-002Left side panel, no louvers SS
A38025-001Left side panel, louvered for
Air cooled E & F & H series
16A37193-001Left side channel
1702-3696-03Left grommet
18A37216-001Bracket
1902-3696-02Right grommet
2003-1531-01Screw
21A37201-01524” Left front panel, grey
A37201-00224” Left front panel, SS
22A37195-001Top front channel
23A37489-031SS 48” panel w/o louvers
A37489-002Grey 48” panel w/o louvers
A37489-033SS 48” panel with louvers
A37489-004Grey 48” panel with louvers
23a03-1735-01Screw
2402-3794-02Trim strip
12-2701-01Bin thermo harness
12-2663-01Lo voltage harness, A-C
12-2659-01Hi voltage harness, A-C
12-2679-01Relay, -6 B thruH
12-2686-01Fuse, -6 B thru H
12-2639-02Transformer, -6 B, thru H
12-2798-01Hi volt harness, -6 B thruH
12-2738-01Lo volt harness, -6 B thru C
12-2792-01Lo volt harness, -6 D thru H
D thru H series:
12-2791-01Lo voltage harness, 60 Hz
12-2796-01Hi voltage harness, 60 Hz
April 2010
Page 6
CME1356 and CME1656 Service Parts
BH900 Ice Storage Bin
10
1
2
20
13
14
12
19
15
18
17
16
11
9
8
7
6
5
3
4
ITEMPARTS
NUMBER NUMBERDESCRIPTION
1A35322-020Canopy Assembly
2A35152-001Ice Baffle
302-2809-01Drain Top
413-0617-11O-ring
502-3201-01Drain casting
6KLP2E Leg Kit, Black
715-0808-01Emblem
813-0595-00Door gasket( order qty 7)
919-0503-04Bin gasket (order by foot)
1003-0727-11Baffle screw
11A35275-001Door frame assy. except
C
A37641-021C series door frame
12A35323-020Door with gasket -
BH900
1303-1539-09“E” ring
1402-2380-01Hinge bushing
1502-3195-01Door hinge
1602-3196-01Bin hinge
1702-2806-01Shoulder screw
1802-2380-02Spacer
1903-1403-29Screw 10-24
2003-1403-24Screw 10-24
August 2007
Page 7
CME1356 and CME1656 Service Parts
BH1356 Ice Storage Bin
1
15
Gasket: 02-3769-17,
order number of feet
16
14
13
11
12
10
2
3
4
5
6
7
8
9
ItemPart
NumberNumberDescription
102-3769-02Track
202-3769-16Window
302-3769-04Lower frame assembly
402-3769-08Left and right hinges
502-3769-05Door with door hinges
602-3769-07Right hinge
702-3769-09Ice gate
802-3769-12End plate guide (pair)
902-3769-13Screws for end plate
1002-3769-14Plugs for end plate
1102-3769-10Catch for ice gate
1202-3769-15Ice gate retainer
1302-3769-06Left hinge
1402-3769-01Plastic drain
15KLP2SLegs
June 2002
Page 8
CME1356 and CME1656 Service Parts
Stacking Kit - KSCME6-LG
A37344-001
Left Bracket
Kit Parts
A37344-002
Rt. Bracket
02-3749-02
Rt. Shield
02-3749-01
Left Shield
Stacking Kit KSCME6-LG-B
02-3885-02
A37935-001
02-3885-01
June 2002
Page 9
Harness: 12-2699-01
W/R
(AC ONLY)
HIGH PRESSURE
CONTROL
(WC ONLY)
O
DUMP
VALVE
RELAY
R/W
L1T1
L2
T2
CONTACTOR
LINE
LOAD
TRA NSFO RM ER
MOT
PUMP
S
OL ENO ID
SO LEN OI D
HOT GAS
WATER
JUNCTI ON
BOX
TERM INAL BOX
C1 S2
R3
COM P RESSOR
W
BK
R
PROT ECTOR
I N TERN A L
USE COPPER CONDUCTORS ONLY
THIS UNIT MUST
BE GROUNDED.
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE AND ALL STATE AND LOCAL CODES.
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
17-2771-01
E A RT H G RO U ND
GR OUND
SCREW
RUN
CAP
PTC R
POWER SUPPLY
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
2 WIRE COLOR FOR 208-230/60/1 UNITS: BLACK
WIRE COLOR FOR 230/50/1 UNITS : BLUE
MOT
FAN
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
WATE R
LEVEL
SENSOR
BN
W
BU
W
BK
BK
LB
O
O
W/R
V
GRAY
2
3
98
7
6
COMM UNICATIONS
PORT
1234 567 1234
5
12345
4
123
3
123
2
1234 5
1
12 3
BIN FULL
TRANSMITTER
ELECTRONIC
CONTROL
BU
BK
Y
R
W/Y
W/R
W
DUMP
VALVE
BK
W/R
BU
Y
1
1
BIN FULL
RECEIVER
THERMO
BIN
(OPTIO NAL)
Y
3 WIRE COLOR FOR 208-230/60/1 UNITS: BLACK W/WHITE STRIPE
WIRE COLOR FOR 230/50/1 UNITS : BROWN
CAUTION:
PTCR WILL BE HOT.
COMPRESSOR MAY
NOT START IF
PTCR IS NOT
ALLOWED TO COOL.
CME1356 and CME1656 Service Parts
Single Phase 60 Hz Wiring Diagram,D-HSeries
August 2007
Page 10
CME1356 and CME1656 Service Parts
L1
L2
LINE
24V
TRANSFORMER
HOT GAS VALVE
WATER VALVE
COMPRESSOR
RUN
CAP.
WATER
PUMP
CONTACTOR T1
WATER
LEVEL
SENSOR
BIN
FULL
RCV.
BIN
FULL
X-MIT
SUMP
TEMP.
DISCHARGE
TEMP.
FAN
MOTOR
(AC
ONLY)
ELECTRO NIC CO NTR OL
DUMP VALVE RELAY TRIGGER
DUMP VALVE RELAY
CONTACTS
DUMP
VALVE
BIN
STAT
(OPTIONAL)
PTCR
HIGH
PRESSURE
CONTROL
(WC ONLY)
CONTACT OR COI L
Single Phase Schematic Diagram,D-HSeries
August 2007
Page 11
CME1356 and CME1656 Service Parts
Single Phase 60 Hz Wiring Diagram,D-HSeries
August 2007
Page 12
CME1356 and CME1656 Service Parts
W/R
R
BK
W
BN/BU
BN
1
0
4
6
1
0
4
6
1
0
4
6
BN
O
O
O
BN
BU
V
W/BU
V/BU
BU/W
BN/BU
1
1
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
POWER SUPPLY
JUNCTION
BOX
V
DUMP
VALVE
TIMER
L1T1
L2
T2
CONT ACT OR
TRANSFORMER
MOT
PUMP
SOLENOID
SOLENOID
HOT GAS
WATER
TERMINAL
BOX
C1
S2
R3
COMP RES SOR
W
BK
R
PROT ECT OR
INTERNAL
USE COPPER CONDUCTORS ONLY
THIS UNIT MUST
BE GROUNDED.
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE AND ALL STATE AND LOCAL CODES.
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
17-2775-01
RUN
CAP
PTCR
MOT
FAN
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
WATE R
LEVEL
SENS OR
LB
O
O
V
GRAY
9
8
7
6
COMM UNI CAT ION S
PORT
1
23456 7
1234
5
1
2345
4
1
2331
23
2
1
234511
23
BIN FULL
TRANSMITTER
ELECTRONIC
CONTROL
DUMP
VALVE
W/R
BIN FULL
RECEIVER
THER MO
BIN
BK
BK
LINELOAD
6
1
2
5
12
11
8
7
PUMP RELAY
DUMP RELAY
FAN RELAY
G/Y
EART H G ROU ND
GROUND SCREW
BU/BN
O
O
O
Y
V
O
W/BN
BK
BU/V
Y
V
V
W/R
W/Y
BU
BU
BU
CAUTION:
PTCR
WILL BE HOT.
COMPRESSOR
MAY NOT START
IF PTCR IS NO T
ALLOWED
TO COOL.
PTCR
CONTACTOR
COIL
HI PRESS.
CONTROL
L1
L2
LINE
24V
TRANSFORMER
HOT GAS VALVE
WATER VALVE
COMPRESSOR
RUN
CAP.
WATER
PUMP
CONTACTOR T1
WATER
LEVEL
SENSOR
BIN
FULL
RCV.
BIN
FULL
X-MIT
SUMP
TEMP.
DISCHARGE
TEMP.
FAN
MOTOR
ELECTRONIC CONTROL
DUMP VALVE TIMER TRIGGER
DUMP VALVE
RELAY CONTACTS
DUMP
VALVE
BIN
STAT
FAN RELAY COIL
PUMP RELAY COIL
FAN RELAY
WATER PUMP RELAY
FUSE
(3A)
DUMP VALVE
RELAY COIL
Single Phase Schematic Diagram,D-HSeries
August 2007
Page 13
CME1356 and CME1656 Service Parts
PTCR
CONTACTOR
COIL
HI PRESS.
CONTROL
W/R
R
BK
W
BN/BU
BN
1
0
4
6
1
0
4
6
BN
O
O
O
BN
BU
V
W/BU
V/BU
BU/W
BN/BU
1
1
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
POWER SUPPLY
JUNCTION
BOX
V
DUMP
VALVE
TIMER
L1T1
L2
T2
CONT ACT OR
TRANSFORMER
MOT
PUMP
SOLENOID
SOLENOID
HOT GAS
WATER
TERMINAL
BOX
C1 S2
R3
COMPRESSOR
W
BK
R
PROT ECT OR
INTERNAL
USE COPPER
COND UCTO RS
ONLY
THIS UNIT MUST
1 DA SH ED LINES INDICATE
FIEL D WIRI NG WHICH MUST BE
INST AL LE D
IN ACCORDANCE
WITH THE NATIONAL
ELEC TR IC AL
CODE AND ALL STATE AND LOCAL CODES.
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
17-2776-01
RUN
CAP
PTCR
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
WATER
LEVEL
SENSOR
LB
O
O
V
GRAY
9
8
7
6
COMMUNICATIO NS
PORT
1
234567
123 4
5
1
2345
4
1
2331
23
2
1
234511
23
BIN FULL
TRANSMITTER
ELECTRONIC
CONTROL
DUMP
VALVE
W/R
BIN FULL
RECEIVER
THER MO
BIN
BK
BK
LINELOAD
6
1
2
5
12
11
8
7
L1
L2
LINE
24V
TRANSFORMER
HOT GAS VALVE
WATER VALVE
COMPRESSOR
RUN
CAP.
WATER
PUMP
CONTACTOR T1
WATER
LEVEL
SENSOR
BIN
FULL
RCV.
BIN
FULL
X-MIT
SUMP
TEMP.
DISCHARGE
TEMP.
ELECTRONIC CONTROL
DUMP VALVE TIMER TRIGGER
DUMP VALVE
RELAY CONTACTS
DUMP
VALVE
BIN
STAT
PUMP RELAY COIL
WATER PUMP RELAY
FUSE
(3A)
DUMP VALVE
RELAY COIL
PUMP RELAY
DUMP RELAY
G/Y
EARTH GRO UND
GROUND SCREW
BU/BN
O
O
V
O
W/BN
BK
BU/V
Y
V
V
W/R
W/Y
BU
BU
Y
HIGH PRESSURE
CONTROL
Y
FOR A.C.
UNITS ONLY
CAUTION: PTCR
WILL BE HOT.
COMPRESSOR
MAY NOT START
IF PTCR IS NOT
ALLOWED TO COOL.
Three Phase Wiring Diagram,D-HSeries
August 2007
Page 14
DUMP
VALVE
RELAY
R
L1T1
L2
T2
CONTACTOR
LINE
LOAD
TRANSFORMER
MOT
PUMP
SOLENOID
SOLENOID
HOT GA S
WATER
JUNCTION
BOX
TERMINAL BOX
C1
S2
R3
COMPRESSOR
W
BK
R
PROTECTOR
INTERNAL
USE COPPER CONDUCTORS ONLY
THIS UNIT MUST
BE GROUNDED.
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE AND ALL STATE AND LOCAL CODES.
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
17-2502-01
EARTH GROUND
GROUND
SCREW
POTENTIAL RELAY
1
2
5
RUN
CAP
START
CAP
POWER SUPPLY
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
2 WIRE COLOR FOR 208-230/60/1 UNITS: BLACK
WIRE COLOR FOR 230/50/1 UNITS : BROWN
MOT
FAN
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
WATER
LEVEL
SENSOR
BN
W/BN
BU
W/BU
BK
BK/W
BU
O
O
O
O
V
R
2
2
98
7
6
COMMUNICATIONS
PORT
1234567 1234
5
12345
4
123
3
123
2
12345
1
1
2
3
BIN FULL
TRANSMITTER
ELECTRONIC
CONTROL
BU
BK
Y
R
R/W
BN
Y/W
W/R
W
BU
DUMP
VALVE
B/W
W/R
W/R
BU
Y
1
1
BIN FULL
RECEIVER
THERMO
BIN
(OPTIONAL)
CME1356 and CME1656 Service Parts
Single Phase 50 Hz Air Cooled Wiring Diagram,D-HSeries
August 2007
Page 15
CME1356 and CME1656 Service Parts
L1
L2
LINE
24V
TRANSFORMER
HOT GAS VALVE
WATER VALVE
CONTACTOR COIL
COMPRESSOR
RUN
CAP.
START
CAP.
POTENTIAL
RELAY
WATER
PUMP
POTENTIAL
RELAY COIL
CONTACTOR T1
WATER
LEVEL
SENSOR
BIN
FULL
RCV.
BIN
FULL
X-MIT
SUMP
TEMP.
DISCHARGE
TEMP.
FAN
MOTOR
ELECTRONIC CONTROL
DUMP VALVE RELAY TRIGGER
DUMP VALVE RELAY
CONTACTS
DUMP
VALVE
BIN
STAT
(OPTIONAL)
Single Phase, 50 Hz Water Cooled Wiring Diagram,D-HSeries
August 2007
Page 16
L
CME1356 and CME1656 Service Parts
Air Cooled Three Phase Wiring Diagram, A - C
17-2511-03
THERMO
BIN
(OPTIONAL)
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
BIN FULL
TRANSMITTER
BIN FULL
RECEIVER
THIS UNIT MUST
BE GROUNDED.
USE COPPER CONDUCTORS ONLY
BU
SOLENOID
WATER
LEVEL
SENSOR
WATER
MOT
PUMP
O
O
O
89
7
6
54321
5
ELECTRONIC
321
CONTROL
4
321
3
54321
2
3
COMMUNICATIONS
2
1
1
PORT
CAUTION:
MOT
FAN
W/BN
BN
BU
W/BU
BK
BK/W
V
Y
43217654321
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
HOT GAS
R
SOLENOID
JUNCTION
BOX
GROUND
SCREW
EARTH GROUND
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZ E
O
W/R
BK
BK
BK
1
1
1
POWER SUPPLY
W/R
L1
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICA
CODE AND ALL STATE AND LOCAL CODES.
LOAD
LINE
TRANSFORMER
W
BU
R
B/W
DUMP
VALVE
L3L2
T3T2T1
PROTECTOR
INTERNAL
RELAY
COMPRESSOR
R
TERMINAL BOX
R
BK
W
R
C1
S2
R3
DUMP
VALVE
BU
R
June 2002
Page 17
CO
SSO
CME1356 and CME1656 Service Parts
Air Cooled Three Phase Schematic Diagram
L1
BIN
STAT
(OPTIONAL)
TRANSFORMER
LINE
DUMP VALVE RELAY TRIGGER
24V
HOT GAS VALVE
WATER VALVE
CONTACTOR COIL
ELECTRONIC CONTROL
L2
L3
SUMP
TEMP.
DISCHARGE
TEMP.
DUMP VALVE RELAY
CONTACTS
DUMP
VALVE
CONTACTOR T1
BIN
FULL
X-MIT
BIN
FULL
RCV.
WATER
PUMP
WATER
LEVEL
SENSOR
FAN
MOTOR
T2
T3
MPRE
R
June 2002
Page 18
17-2503-01
THERMO
BIN
(OPTIONAL)
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
BIN FULL
TRANSMITTER
BIN FULL
RECEIVER
THIS UNIT MUST
BE GROUNDED.
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
CME1356 and CME1656 Service Parts
Water Cooled Single Phase Wiring Diagram, A - C
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
USE COPPER CONDUCTORS ONLY
BU
SOLENOID
WATER
LEVEL
SENSOR
WATER
MOT
PUMP
O
O
O
1234567 1234
7
6
5
1 2 3 4 5
ELECTRONIC
CONTROL
4
1 2 3
3
1 2 3
2
1 2 3 4 5
3
COMMUNICATIONS
2
1
1
PORT
W/BN
BN
BU
W/BU
BK
BK/W
V
Y
98
R
HIGH PRESSURE
CONTROL
HOT GAS
O
SOLENOID
JUNCTION
BOX
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
W/R
W/R
L1T1
CONTACTOR
T2
L2
W/R
Y
2
2
GROUND
SCREW
1
1
POWER SUPPLY
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE AND ALL STATE AND LOCAL CODES.
2 WIRE COLOR FOR 208-230/60/1 UNITS: BLACK
WIRE COLOR FOR 230/50/1 UNITS : BROWN
LOAD
LINE
TRANSFORMER
W
BU
R
BK/W
BU
POTENTIAL RELAY
5
Y/W
BN
EARTH GROUND
RUN
CAP
START
CAP
1
2
R/W
PROTECTOR
INTERNAL
COMPRESSOR
DUMP
VALVE
RELAY
TERMINAL BOX
R
BK
W
DUMP
VALVE
BU
BK
C1
R
Y
S2
R3
June 2002
Page 19
CO
SSO
CME1356 and CME1656 Service Parts
Water Cooled Single Phase Schematic Diagram, A - C
L1
BIN
STAT
(OPTIONAL)
TRANSFORMER
LINE
DUMP VALVE RELAY TRIGGER
24V
HOT GAS VALVE
WATER VALVE
HIGH
CONTACTOR COIL
PRESSURE
CONTROL
ELECTRONIC CONTROL
L2
SUMP
TEMP.
DISCHARGE
TEMP.
DUMP VALVE RELAY
CONTACTS
DUMP
VALVE
CONTACTOR T1
POTENTIAL
RELAY COIL
BIN
FULL
X-MIT
BIN
FULL
RCV.
WATER
PUMP
POTENTIAL
RELAY
WATER
LEVEL
SENSOR
START
CAP.
MPRE
June 2002
Page 20
RUN
CAP.
R
L
CME1356 and CME1656 Service Parts
Water Cooled Three Phase Wiring Diagram
17-2512-03
THERMO
BIN
(OPTIONAL)
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
BIN FULL
TRANSMITTER
BIN FULL
RECEIVER
THIS UNIT MUST
BE GROUNDED.
USE COPPER CONDUCTORS ONLY
WATER
SOLENOID
BU
WATER
LEVEL
SENSOR
CAUTION:
MOT
PUMP
W/BN
BN
W/BU
BK
BK/W
V
Y
98
HI PRESSURE
CONTROL
O
O
O
1234567 1234
7
6
5
1 2 3 4 5
ELECTRONIC
CONTROL
4
1 2 3
3
1 2 3
2
1 2 3 4 5
3
COMMUNICATIONS
2
1
1
PORT
BU
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
HOT GAS
R
SOLENOID
Y
BK
JUNCTION
BOX
1
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
O
W/R
L1
T1 T2 T3
BK
BK
GROUND
SCREW
1
1
POWER SUPPLY
W/R
L2 L3
EARTH GROUND
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICA
CODE AND ALL STATE AND LOCAL CODES.
Affects all versions of models: CME1356, CME1656, CME1856 and CME2006
The above models are now manufactured with a sheet metal cover over the top of the controller.
Service controllers also are now shipped with a cover that should be applied to these models
whenever replacing the controller if the machine does not already have a cover installed.
Whenever cleaning or servicing any unit, check to see whether it has a cover over the controller like
the one shown below. If it does not, Scotsman recommends installing a cover. A separate part is
now available for this purpose. Its part number is A37480-021. It mounts over the top end of the
controller and is secured by two sheet metal screws. Use the cover as a template and drill two 1/8”
holes for the two screws.
Controller Cover
Scotsman is shipping a supply of covers to all Scotsman Distributors and listed service agencies. A
supply of covers should be carried by each service person on service calls so a cover may be
installed on the unit being cleaned or serviced if one is not already in place. Additional covers may
be obtained free of charge from Scotsman, through the local Scotsman Distributor, as needed.
Cover Installed on Unit
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.