This product manual contains the information
needed for the setup, installation, initial start up,
sanitation and maintenance of this ice machine.
Keep it for future reference.
Be certain that the information applies to the model
in question. If no model is listed, the information
applies to all models.
TABLE OF CONTENTS
Specifications ,,,,,,,,,,,,,PAGE2
Condenser and Ice Machine Layouts , PAGE 3
Pre-Installation ,,,,,,,,,,,,,PAGE4
Location & Assembly ,,,,,,,,,PAGE5
Stacking ,,,,,,,,,,,,,,,,PAGE6
Stacking ,,,,,,,,,,,,,,,,PAGE7
Bin Control: Installation ,,,,,,,,PAGE8
For The Installer: Remote Condenser , PAGE 9
This manual is organized in the same way as the
expected use of the machine, it begins with
specifications, goes thru unpacking and setup,
shows where everything is; continues with initial
start up, then describes how it works. After that is
the sanitation section, followed by service
diagnosis and repair.
Technicians Only: Harvest Cycle Sequence &
Other Notes ,,,,,,,,,,,,,,PAGE24
Sanitation and Cleaning ,,,,,,,,PAGE25
Additional Maintenance ,,,,,,,,PAGE26
Additional Maintenance: Inlet Water Valve Screen
,,,,,,,,,,,,,,,,,,,,,PAGE27
Additional Maintenance: Ice Sensors, Condenser
,,,,,,,,,,,,,,,,,,,,,PAGE28
Service Diagnosis: Diagnostic Light Analysis
,,,,,,,,,,,,,,,,,,,,,PAGE29
Remote Condenser Location ,,,,,PAGE10
Coupling Instructions ,,,,,,,,,PAGE11
Head Pressure Control Add-On Kit , , PAGE 12
Electrical ,,,,,,,,,,,,,,,,PAGE13
Plumbing ,,,,,,,,,,,,,,,,PAGE14
After Utility Connections ,,,,,,,,PAGE15
Component Location and Function , , PAGE 16
AutoIQ Controller ,,,,,,,,,,,PAGE17
Initial Start Up ,,,,,,,,,,,,,PAGE18
Adjustments ,,,,,,,,,,,,,,PAGE19
How To Operate The AutoIQ Controller PAGE 20
How The Electronic Cuber Works , , , PAGE 21
How The Electronic Cuber Works , , , PAGE 22
Technicians Only: Freeze Cycle Sequence
,,,,,,,,,,,,,,,,,,,,,PAGE23
Service Diagnosis ,,,,,,,,,,,PAGE30
Service Diagnosis: Components,,,,PAGE31
Service Diagnosis ,,,,,,,,,,,PAGE32
PTCR Diagnosis ,,,,,,,,,,,,PAGE33
Operational Characteristics: CME1056R
,,,,,,,,,,,,,,,,,,,,,PAGE34
Removal and Replacement ,,,,,,PAGE35
Removal and Replacement ,,,,,,PAGE36
Removal and Replacement: AutoIQ Controller
,,,,,,,,,,,,,,,,,,,,,PAGE37
Removal and Replacement: Water Level Sensor
,,,,,,,,,,,,,,,,,,,,,PAGE38
Removal and Replacement ,,,,,,PAGE39
Refrigerant ,,,,,,,,,,,,,,,PAGE40
Before Calling for Service ,,,,,,,PAGE41
Parts Lists and Wiring Diagrams are in the section at the center of this manual.
May 2000
Page 1
Page 2
CME1056R
Specifications
Both of these ice machines are designed to be
installed indoors, in a controlled environment. They
can operate satisfactorily under a wide variety of
conditions. However, Do NOT operate the
machine in temperatures it has not been designed
for. Do NOT operate the machine above or below
the voltage limits for the particular model. Do NOT
operate the machine with too little or too much
water pressure.
Operational Limits
MinimumMaximum
Air Temperature50oF.100oF.
Water Temperature40oF.100oF.
Water Pressure20 psi80 psi
Voltage (60 Hz)197253
Voltage (50 Hz)207253
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
Bins:
All models will fit a standard, 30" wide or wider
open top Scotsman Ice Storage Bin. Some
examples are:
BH550
•
HTB555
•
Dispensers
ID200 or ID250, use adapter KBT44
•
Lancer 30” wide dispenser. Add adapter kit
•
KSTAT-MD.
Kits
BH800 bin: Add kits KBT23
•
BH900 bin: Add kits KBT22
•
In addition, there may be other bins and
dispensers that can be used, check Scotsman’s
sales literature for application information.
* The remote condenser is designed to work in temperatures from -20oF. to 120oF.
Use precharged tubing kits, RTE25 (25’) or RTE40 (40’) or RTE75 (75’). Select the length closest to the
needs of the particular installation.
WxDxH
(w/o bin)
Basic Electrical
(volts/Hz/phase)
March 2003
Page 2
•
The kit required to connect this ice machine
to an approved central condenser is:
RCKCME6GX.
Use
Condenser
Refrigerant
Charge
R-404A
Minimum
Circuit
Ampacity
Maximum
Fuse Size
Page 3
Condenser and Ice Machine Layouts
.88 DIA. ELECTRICAL
INLET
DISCHARGE LINE
1/2" MALE CPLG.
29.50 in
74.9 cm
CME1056R
ERC311
.562 DIA.
MOUNTING
HOLES (4)
CONDENSER FINS
15-0782-01CANCAUSEINJURYOR DEATH:DISCONNECT ALL REMOTE ELECTRICPOWERSUPPLIESBEFORESERVICING.RISKOFELECTRICSHOCK^MWARNING
23.54 in
59.7 cm
29.15 in
74.0 cm
2.75
35.72 in
90.7 cm
2.84 in
7.2 cm
6.00 in
15.2 cm
38.47 in
97.7 cm
32.32 in
82.1 cm
28.07 in
71.2 cm
7.60 in
19.3 cm
MINIMUM FOR
UTILITY CONNECTIONS
24.71 in
62.7 cm
11.50 in
29.2 cm
14.56 in
36.9 cm
27.56 in
70.0 cm
29.19 in
74.1 cm
PLAN VIEW
.65 in
1.7 cm
LIQUID LINE
3/8" MALE CPLG.
AIR FLOW
2.70 in
6.9 cm
ICE
OPENING
REMOTE CONDENSER
LIQUID LINE
3/8" MALE CPLG.
REMOTE CONDENSER
DISCHARGE LINE
1/2" MALE CPLG.
21.75 in
55.2 cm
19.90 in
22.15 in
56.3 cm
50.5 cm
15.75 in
40.0 cm
SUMP DRAIN
3/4" F.P.T.
BACK VIEW
.88 DIA. KNOCKOUT
ELECTRICAL INLET
20.12 in
51.1 cm
22.25 in
56.5 cm
10.75 in
27.3 cm
May 2000
Page 3
.88 DIA. KNOCKOUT
REMOTE CONDENSER FAN
WATER INLET
3/8" FLARE
17.68 in
44.9 cm
4.31 in.
10.9 cm
2.38 in
6.0 cm
4.75 in
12.1 cm
18.70 in
47.5 cm
ICE
OPENING
SIDE VIEW
24.00 in
61.0 cm
9.85 in
25.0 cm
1.63 in
4.1 cm
Page 4
CME1056R
Pre-Installation
Other Applications:
Check sales literature for additional information.
Note: Slope-front bins must have an internal baffle.
Scotsman HTB555 and BH550 have the required
baffle. Baffle must be approximately in the position
shown in the diagram below.
Baffle
12.0"
4.0"
Side View
Electrical:
Check the nameplate for electrical requirements.
The nameplate is located on the back of the ice
machine. If the information on the nameplate is
different from other published information, go by
the nameplate data.
While the model and
serial number are on
the nameplate, a
serial number plate
is located at the
front of the machine,
behind the front
panel and to the right
of the purge valve.
Water:
There is no such thing as pure water. All water
contains some impurities. There are two ways
water carries the impurities: suspended and
dissolved. Suspended solids can be filtered out.
Dissolved solids must be diluted or treated. Water
filters are recommended to remove suspended
solids. Some filters also have treatment in them for
dissolved solids. Check with a water treatment
service for a recommendation.
Cube Ice machines use more water than what
ends up in the bin as ice. While most water is used
during ice making, a portion is designed to “rinse"
out the water system to keep hard water scale
from clogging up the machine. That water rinse,
combined with water filters, prolongs the times
between needed water system cleaning.
Service Technicians: All models covered here
come set from the factory with at a “Standard”
water rinse. Standard water rinse is designed to be
compatible with typical water conditions. The
machine may be adjusted to a different water rinse
after start up. If the prior ice machine worked
acceptably well with the local water conditions,
leave the machine at the factory setting. If severe
water conditions are present, and water filters do
not solve the problem acceptably, adjust the
machine to use more water. If water conditions are
excellent, adjust the machine to use less water.
See the Adjustments section.
Note: Water use adjustments are customer
convenience adjustments; they are NOT factory
defects and are NOT covered by warranty.
Nameplate, on back panel
Serial Number Plate, remove front
panel to locate.
May 2000
Page 4
Page 5
Location & Assembly
CME1056R
Locate the ice machine indoors. A 6 inch minimum
clearance on the back and sides is required for the
proper operation and service of this machine.
Locate the remote condenser as close as possible
to the ice machine. See page 11 for details.
Unpacking and Assembly:
Begin with unpacking the ice storage bin. Remove
the carton, and using part of the carton as a
cushion, tip the bin on its back to remove the skid
and attach the legs or casters. Note: Stacked
applications may not use casters.
Return the bin to an upright position. Check the bin
top gasket for gaps and tears, fill any in with food
grade sealant prior to placing the ice machine on
the bin.
Note: If recycling a prior bin, be sure that the bin
top gasket is in good condition or seal the ice
machine to the bin with food grade sealant.
Level the top edge of the bin front to back and left
to right.
Cabinet Panel Removal:
1. Remove the front panel by removing the two
screws connecting the top of the front panel to the
machine, then pull out at the bottom.
2. Lift up at the front edge and push the top panel
back until it releases from the tabs connecting it to
the back panel.
If the ice machine has not been unpacked, do so
now. Remove the carton from the skid. Remove
shipping straps.
Remove the front panels and all packaging
materials.
After all packing materials have been removed
from the ice machine, lift or hoist the machine onto
the bin. Align the sides and back of the machine
with the sides and back of the bin.
Secure the ice machine to the bin with the two
metal straps and 4 bolts provided.
3. Remove two screws at the front of each side
panel, and pull them forward until they release
from the tabs connecting them to the back panel.
May 2000
Page 5
Page 6
CME1056R
Stacking
Only like models may be stacked. Begin after the
bottom unit has been placed on the ice storage bin
and secured. Stacking requires heavy duty leg kits.
Casters are NOT recommended.
Bottom Machine:
1. Remove front, side, and top panels.
2. Hang the plastic shield from the tabs on the
stainless steel bracket.
3. Locate the two notches on the sides of the top
edge of the freezing compartment.
Bracket
Mounting
Notch
11. Route the Stacking Kit wire harness from the
back to the top and bottom machines thru the
holes made in steps 8 and 9.
The harness is marked which end goes to which
machine.
Push the strain reliefs into place from the back of
the machines.
Follow local codes for 24 volt wire
4. Place the bracket over the notches of the
freezing compartment.
5. Secure bracket to freezing compartment with
screws from the kit (from the sides).
6. Locate gasket material in kit. Place a layer of
gasket material on the top edge of the plastic
freezing compartment.
7. Place the top ice machine onto the bottom one.
Secure together with hardware from the top
machine. Remove front and left side panels.
Upper Machine:
8. Knock out 1 hole in the lower left (viewed from
the front) corner of the upper unit’s back panel.
Lower Unit:
9. Knock out 1 hole in the upper left (viewed from
the front) corner of the lower unit’s back panel.
10. Position the strain reliefs over the wrapped
portion of the stacking kit wire harness.
Bin
Thermostat
Mounted in
Machine
12. Route wire harness in lower ice machine to the
controller. Connect to terminal #7. Plug the two
free wires onto thermostat terminals #1 and #2
December 1998
Page 6
Page 7
Stacking
CME1056R
13. Route the wire to the controller. Connect to
terminal 7.
Thermostat
Routing
Hole
Thermostat
Bulb
Bottom Machine
14. Route the bulb of the thermostat thru the base
of the unit into the bin.
15. Mount the bulb of the thermostat to the
bracket from the kit.
16. Install the bin thermostat bracket onto the
bottom of the machine.
17. Pull back excess cap tube and coil up in the
machine.
18. Connect wires from harness to thermostat
terminals.
Both Machines:
19. Return all panels and covers to their normal
positions.
20. Complete the balance of the installation.
Thermostat &
Bracket
Mounted to
Ice Machine
Base
May 2000
Page 7
Page 8
CME1056R
Bin Control: Installation
The bin control is a thermostat. It must be field
installed after the ice machine has been placed on
the bin.
Before starting, remove the front panel and any
baffle in the bin.
1. Locate bin thermostat bulb.
3. Route bulb thru routing tube (located between
the compressor and the reservoir).
6. Fasten the bracket to the bottom of the ice
machine with the two 3-pronged knobs supplied
with the unit.
7. Pull back into the ice machine any excess
capillary tubing.
8. Return the baffle to the bin and continue with
the installation.
Note: If the machine is located at an altitude
higher than 2,000 ft., adjust the thermostat by
removing the plastic cover and rotating the
adjustment screw per the table.
4. Locate bin thermostat bracket.
5. Carefully position the thermostat bulb on the
bracket.
Bin Thermostat Altitude Correction Table
CW Turns of Range Screw (under plastic cover)
FeetTurnsFeetTurns
200055
4000160
6000250
o
o
o
8000340
9000385
10000405
o
o
o
Use This Table to Adjust Thermostat
May 2000
Page 8
Page 9
For The Installer: Remote Condenser
CME1056R
Locate the condenser as near as possible to the
interior location of the ice maker.
Note: The location of the condenser relative to the
ice machine is LIMITED by the specification on the
following page.
Select the best available location, one that protects
the condenser from extremes of dust, grease and
sun.
Meet all applicable building codes.
Roof Attachment
Install and attach the remote condenser to the roof
of the building, using the methods and practices of
construction that conform to the local building
codes, including having a roofing contractor secure
the condenser to the roof.
Note: If using any other condenser
besides the ERC311, its use must be
approved by Scotsman, and a head
pressure control valve must be
connected to the condenser coil. The
head pressure valve kit number is:
RCKCME6
Precharged Line Routing
Do not connect the precharged tubing
until all routing and forming of the tubing
is complete. See the Coupling
Instructions for final connections.
Note: Excess tubing may EITHER be coiled up
INSIDE the building OR cut out prior to connection
to the ice maker and condenser.
If the excess tubing is cut out, after re-brazing the
tubing must be evacuated prior to connection to
the ice maker or condenser.
If the excess tubing is to be coiled, spiral it
horizontally to avoid excess trapping in the lines.
Note: A 36" service loop may be placed behind the
ice machine.
5. Have the roofing contractor seal the holes in the
roof per local codes.
ERC311 Remote
Condenser
Electrical Power
Supply
Coil Excess
Tubing
Horizontally
Within the
Building
1. Each set of pre-charged tubing lines
contains a
1
” diameter discharge line. Both ends of
2
3
“ diameter liquid line, and a
8
each line have quick connect couplings,
the end without access valves goes to
the ice maker.
Note: The openings in the building ceiling
or wall, listed in the next step, are the
minimum sizes recommended for
passing the refrigerant lines through.
2. Have the roofing contractor cut a
minimum hole for the refrigerant lines of
2“. Check local codes, a separate hole
may be required for the electrical power
supply to the condenser.
Caution: Do NOT kink the refrigerant
tubing while routing it.
3. Route the refrigerant tubes thru the
roof opening. Follow straight line routing
whenever possible.
Typical Installation
May 2000
Page 9
Page 10
CME1056R
Remote Condenser Location
Use the following for planning the placement of the
condenser relative to the ice machine
Location Limits - condenser location must not
exceed ANY of the following limits:
Maximum rise from the ice machine to the
•
condenser is 35 physical feet
Maximum drop from the ice machine to the
•
condenser is 15 physical feet
Physical line set maximum length is 100
•
feet.
Calculated line set length maximum is 150.
•
Calculation Formula:
Drop = dd x 6.6 (dd = distance in feet)
•
Rise = rd x 1.7 (rd = distance in feet)
•
Horizontal Run = hd x 1 (hd = distance in
•
feet)
Calculation: Drop(s) + Rise(s) + Horizontal
•
Run = dd+rd+hd = Calculated Line Length
Configurations that do NOT meet these
requirements must receive prior written
authorization from Scotsman.
Do NOT:
Route a line set that rises, then falls, then
•
rises.
Route a line set that falls, then rises, then
•
falls.
Calculation Example 1:
The condenser is to be located 5 feet below the ice
machine and then 20 feet away horizontally.
5 feet x 6.6 = 33. 33 + 20 = 53. This location would
be acceptable
Calculation Example 2:
The condenser is to be located 35 feet above and
then 100 feet away horizontally.
35 x 1.7 = 59.5. 59.5 +100 = 159.5. 159.5 is
greater than the 150 maximum and is NOT
acceptable.
rd
22.87"
dd
17.15"
Max 35’
Max 15’
Remote
Condenser
Located ABOVE
Ice Machine
Remote
Condenser
Located BELOW
Ice Machine
hd
40.35"
Condenser Distance &
Location Schematic
May 2000
Page 10
Page 11
Coupling Instructions
CME1056R
The couplings on the ends of the pre-charged line
sets are self-sealing when installed properly.
Follow these instructions carefully.
These steps must be performed by an EPA
Certified Type II or higher technician.
Initial Connections
1. Remove the protector caps and plugs. Wipe the
seats and threaded surfaces with a clean cloth to
remove any possible foreign matter.
2. Thoroughly lubricate the threads, o-rings,
diaphragms and all internal coupling surfaces with
polyolester refrigerant oil.
Clean and Lubricate Couplings
3. Position the fittings on the correct connections
on the condenser and ice machine.
•
1
The
“ discharge line (schrader valve end)
2
goes to the remote condenser fitting marked
“discharge line”.
•
3
The
“ liquid line (schrod valve end) goes to
8
the remote condenser fitting marked “liquid
line”.
•
1
The
“ discharge line goes to the ice maker
2
fitting marked “discharge line”.
•
3
The
“ liquid line goes to the ice maker
8
fitting marked “liquid line”.
4b. Using two wrenches, one to rotate the swivel
nut and one to hold the tubing in place, tighten
each coupling.
It is CRITICAL that ONLY the NUT on the
pre-charged tube be turned, or the diaphragms will
be torn by the piercing knives and become loose in
the refrigeration system causing severe
operational problems.
Tighten Swivel Nut
Note: As the coupling is tightened, the diaphragms
in the quick connect couplings will begin to be
pierced. As that happens, there will be increased
resistance to tightening the swivel nut.
4c. Continue tightening the swivel nut until it
bottoms out or a very definite increase in
resistance is felt (no threads should be showing).
Do NOT overtighten.
5. Use a marker or pen to mark a line on the
coupling nut and unit panel. Then tighten the
coupling nut an additional one-quarter turn. The
line will show the amount that the nut turns.
6. After all connections have been made, and after
the liquid line valve has been opened (do not open
yet), check the couplings for leaks.
Note: The system charge is contained in the
receiver tank of the ice machine. Only “holding"
charges are present in the “pre-charged" tubing or
the condenser.
Final Connections:
4a. Begin to tighten the couplings together by
hand. Continue to turn the swivel nuts by hand
until it is certain that the threads are properly
engaged.
Rotate Swivel Nut ¼ Turn More
May 2000
Page 11
Page 12
CME1056R
Head Pressure Control Add-On Kit
Kit: RCKCME6GX
Required when a CME1056R is to be connected to
a Remote Condenser that is not equipped with a
Head Pressure Control Valve
2. Locate correct position on condenser: The
RCKCME6GX can fit either a Mac G series or a
Mac X series condenser.
3. Use metal box as a template, mark the positions
of 4 holes to be drilled to mount the box to the
condenser.
4. Drill four .157" (#22 or 5/32" bit) dia. holes.
5. Remove plastic covers from the condenser’s
quick connects and those to be used to connect to
the condenser.
6. Thoroughly clean and lubricate the threads and
diaphragms of both the condenser’s and the kit’s
quick connects. Use Polyolester oil.
8. Start the swivel nuts by hand.
Use a back up wrench to be certain that the
•
tubing is NOT ROTATING. Only the SWIVEL
NUTS should be rotating!
Then use an adjustable wrench to tighten
•
them until no threads are seen AND a very
definite resistance is felt.
9. Mark the positions of the swivel nuts to the
condenser panel.
10. Rotate the swivel nuts additional one-quarter
turn.
11. Place cover on metal box & secure with
screws.
12. Finish the balance of the installation. Ice
machine’s precharged line sets will now connect to
the quick connect fittings on the metal box instead
of the condenser’s.
7. Mount the box to the condenser with the screws
from the kit.
Central
Condenser
Connections
to Central
Condenser
RCKCME6GX
on G series
RCKCME6GX
on X series
Pre-Charged Lines
from Ice Machine
connect here
March 2003
Page 12
Page 13
Electrical
CME1056R
All models must be installed with the correct wire
size and type per the National Electric Code.
Locate the nameplate on the back of the cabinet
and find the numbers for Voltage, Phase, Minimum
Circuit Ampacity and Maximum Fuse Size. Either
fuses or HACR type circuit breakers may be used.
The ice maker is designed to operate on its own
electrical circuit and must be individually fused.
Voltage variation must not exceed the limits listed
on page 2.
The remote condenser is designed to be powered
from the ice machine. A separate knockout hole
has been provided in the ice maker electrical
junction box.
Remote Condenser
Power Connection
Note: Central Condensers connected to more than
one refrigeration system will likely have a wiring
scheme to control the fan motor. Follow those
directions for condenser wiring.
Electrical connections are made in the junction box
in the back of the cabinet.
1. Remove the junction box cover.
2. Knock out both holes for a field supplied strain
relief.
Note: An external junction box may be mounted to
the back of the machine. Holes are pre-drilled for a
open back box such as Scotsman part number
12-2374-01.
3. Install wires and strain reliefs per code. Note:
Condenser fan motor wires are tagged.
4. Connect to wires and secure ground wire to
ground screw inside junction box.
All external wiring should conform to the national,
state and local electrical code requirements.
Usually an electrical permit and the services of a
licensed electrician will be required.
Interconnecting
Wires
Power
Supply
Power OUT
Power IN
May 2000
Page 13
Page 14
CME1056R
Plumbing
All models require an adequate potable water
supply and a gravity drain. The recommendations
for tubing are:
Water supply to be
•
Drain to be
•
3
" OD.
4
3
" OD.
8
Note: When replacing a prior ice machine, do not
take a short cut and reuse the old inlet and drain
system. INSTALL A NEW SYSTEM.
Supply:
3
All models have 1 water supply connection, a
"
8
male flare at the back of the cabinet. Connect to
cold potable water that has adequate pressure.
Note: Using water supply tubing smaller than
3
"
8
will cause severe operational issues.
Water Filters:
The water filters must flow at least 2.7 GPM or they
will cause severe operational issues. Check with
the filter manufacturer. When replacing a prior ice
machine, do NOT assume that the water flow
capacity of the filter will be adequate.
All Drain Tubing Material must be RIGID.
Flexible tubing will eventually cause a
restricted drain.
Drain:
3
All models have 1 gravity drain connection, a
"
4
FPT fitting at the back of the cabinet. Use only
RIGID TUBING. Flexible tubing may be easily
kinked or become cracked.
The drain tube must be vented at the back of the
cabinet. Use an 18" high vent.
The ice storage bin will have a drain out the back
or base, depending upon the model.
The drain for the ice machine and the ice storage
bin must be SEPARATE or the ice machine’s drain
water may run into the bin and MELT THE ICE.
Insulation is recommended for the ice machine
reservoir and bin drains.
Follow all applicable codes
Water Inlet
System
Bin Drain
Water IN
Water OUT
May 2000
Page 14
Page 15
After Utility Connections
1. Wash out the bin. If desired, the interior of the
bin could be sanitized.
2. Locate the ice scoop (if supplied) and have it
available for use when needed.
3. Switch on the electrical power. Do not start the
machine for 4 hours.
4. Go thru the final check list (below).
Final Check List:
___ 1.Is the unit located indoors in a
controlled environment?
___ 2.Has the correct remote condenser been
properly located and mounted?
___ 3.Has the correct electrical power
(voltage and phase) been supplied to
the machine?
CME1056R
___ 4.Have all the water supply connections
been properly made with the correct
size tubing?
___ 5.Have all the drain connections been
properly made?
___ 6.Has the unit been leveled? Level the
unit at the bin.
___ 7.Have all unpacking materials been
removed?
___ 8.Is the water pressure adequate?
___ 9.Is the machine secured to the ice
storage bin?
___ 10. Is the bin control system been properly
installed?
___ 11. Have the drain connections been
checked for leaks?
___ 12. Has the bin interior been wiped clean or
sanitized?
___ 13. Have any water filter cartridges been
replaced?
___ 14. Check all refrigerant lines and conduit
lines, for vibration or rubbing and
possible failure. Adjust as needed.
___ 15. After 4 hours of electrical power,
proceed to Initial Start Up.
May 2000
Page 15
Page 16
CME1056R
Component Location and Function
Reservoir: Contains the water used to make ice.
Water Inlet Valve: Opens to allow water into the
reservoir.
Freezing Compartment: Location of the
evaporators. Ice forms on the evaporators, and is
released when warmed up during the harvest
cycle. The freezing compartment is fully insulated
for maximum efficiency.
Cube Deflector: The slots in the inclined deflector
allows the water falling from the evaporators back
into the reservoir, but when ice falls during harvest,
the ice slides off into the bin.
Harvest Bypass Valve: Injects additional
refrigerant into the harvest system.
Water Pump: Forces the water from the reservoir
to the top of the evaporator(s). The motor is kept
separate from the water to minimize contact with
moisture.
Hot Gas Valve: Closed during freeze, it opens
during harvest to divert hot discharge refrigerant
gas into the inlet of the evaporators.
Purge Valve: Opens during the first part of
harvest, when the water pump restarts the water in
the reservoir is diverted to the drain.
Check Valves: Liquid and Discharge lines contain
check valves. These control refrigerant migration
during the Harvest and Off cycles.
Evaporators
Purge Valve
Controller
Inlet Water Valve
Freezing
Compartment
May 2000
Page 16
Page 17
AutoIQ Controller
CME1056R
Indicator Lights:
Bin Full: On when bin is full, goes on and
•
off as ice falls during a harvest cycle.
Freeze: On when the unit is in the Freeze
•
cycle, blinks when a freeze cycle is pending.
Harvest: On when the unit is in the Harvest
•
cycle.
Clean: On when the unit is in the Clean
•
cycle.
Off: On when the unit has been switched off,
•
blinks when the machine is preparing to shut
off.
Water: On when the controller has identified
•
a problem with the water system.
Refrigeration: On when the controller has
•
identified a problem with the refrigeration
system.
LOW VOLTAGE IN/OUT
WATER VALVE
HOT GAS VALVE
PURGE VALVE TIMER
CONTACTOR COIL
Cycle Definitions:
Freeze: The refrigeration system is
•
operating to remove heat from the
evaporators. The compressor, remote fan
motor and water pump are ON.
Harvest: The refrigeration and water
•
systems are operating to harvest the ice
cubes. While the compressor and fan motors
are on for the full cycle, the water pump will
be off at the beginning and the inlet water
valve will switch off before the end.
Clean: Water valve opens to fill the
•
reservoir. The Water pump starts. The Clean
indicator light is switched ON. A manually
initiated rinse cycle flushes the system.
89
HI VOLTAGE I N / O UT
WATER PUMP
STACKING and/or
THERMOSTAT
FUTURE USE
RESERVOIR & DISCHARGE
LINE THERMISTORS
ICE SENSOR
ICE SENSOR
RESERVOIR WATER
LEVEL SENSOR
FACTORY USE
7
6
5
4
3
2
1
PUSH BUTTON
CONTROL SWITCHES
INDICATOR LIGHTS:
BIN FULL
FREEZE
HARVEST
CLEAN
OFF
DIAGNOSTIC LIGHTS:
WATER
REFRIGERATION
May 2000
Page 17
Page 18
CME1056R
Initial Start Up
1. Remove the front panel.
2. Locate and open the liquid line valve.
Open By Turning
Stem Fully Out (Up)
3. Double check quick-connect couplings for leaks.
4. Locate the AutoIQ Controller.
5. Connect electrical power. All lights will blink on
and off together then the two red lights will blink
while the Harvest light is on. After 20 seconds the
Harvest light will go out and the Bin Full and Off
lights will be on. After a few seconds only the Off
light will be glowing.
6. Open the water supply valve.
7. Push and release the Freeze cycle push button
(the Freeze indicator light will blink until the
compressor starts).
Initial Start (30 seconds)
•
The Freeze light will begin to blink.
•
The hot gas solenoid valve will be open.
•
The purge valve will be open
•
The water pump will be on
•
After 30 seconds, the hot gas valve closes
•
The purge valve closes and the inlet water
valve opens to fill the reservoir. The inlet
water valve closes when the reservoir is full.
•
The compressor & remote fan motor start.
Freeze Cycle
The Freeze indicator light will come on. The unit
will be in a Freeze cycle for many minutes. Slush
may appear in the reservoir, it is temporary and
normal.
•
The pump will stop for a few seconds a few
minutes into the freeze cycle
•
The freeze cycle will continue until the water
level in the reservoir drops to its factory set
point, the first time that happens the water
valve will re-fill the reservoir. The second
time it happens in a freeze cycle starts the
Harvest Cycle.
Harvest Cycle:
The Harvest indicator light will be ON,
•
The hot gas valve will open.
•
The purge valve will be open for 40 seconds.
•
The water pump will switch off. The pump
•
will restart part way thru the harvest cycle.
The purge valve closes.
•
The Inlet water valve opens for a short time
•
The Bin Full indicator light will go on and off
•
as ice falls from the evaporators.
8. Machines are shipped from the factory with the
purge level set to accommodate average water
conditions. To achieve optimal machine
performance, set the purge level to the minimum
setting.
Note: While the amount of water purge is
adjustable, only those installations with a water
supply known to be excellent (very low TDS)
should adjust to the minimum setting. See the next
page for purge adjustment procedures.
9. After about 6 minutes (first cycle after any
restart) the machine will return to a freeze cycle.
Note: After the first harvest, the controller adjusts
the harvest time as needed to release all ice.
10. The reservoir refills at the beginning of Freeze.
11. Fill out the Customer Evaluation and Warranty
Registration. Send it to Scotsman.
12. Return all panels to their normal positions.
13. Inform the user of the location and telephone
number of the local service company. Inform the
user of the required maintenance of the machine.
Operational Notes:
1. The machine will only shut off on Bin Full at the
end of the Harvest Cycle after the bin fills. That
last harvest cycle will be about 6 minutes long.
2. After switching off on Bin Full, if ice is removed
from the bin, the machine will not restart until it has
been off for 4 minutes. If the Freeze button is
pushed, the machine will restart immediately.
3. If the bin controls sense a bin full signal before
any water is used (float stem up), the machine will
shut off on bin full.
4. When shutting off, the compressor will run for 30
seconds (everything else will be off) and then
switch off.
March 2003
Page 18
Page 19
Adjustments
CME1056R
If there was a problem during Initial Start
Up:
If a diagnostic light came on, check the following.
1. Water.
A water error could have been determined by the
AutoIQ Controller if the inlet water valve does not
fill the reservoir or if the water pump does not start
and lower the water level in the reservoir. If either
condition is found, the water error light will be
switched on and the machine will Shut Down.
2. Refrigeration.
A refrigeration error could have been determined
by the AutoIQ Controller if the water temperature
did not drop during the freeze cycle. The
Controller will next check the compressor
discharge temperature. If the discharge
temperature is too low, the refrigerant error light
will be switched on, and the machine will Shut
Down.
Note: The machine can be reset and restarted by
pushing and releasing the Off push button switch,
and then pushing and releasing the freeze push
button switch.
Thermostatic Expansion Valve:
The TXV is not adjustable, do not attempt to adjust
it.
How to Adjust the Amount of Water Purge
Adjustment is done by use of the control buttons
on the AutoIQ Controller. Examine the next section
to become familiar with the AutoIQ Controller
before beginning.
1. If the machine is on, push and hold the OFF
button for more than 3 seconds, then release it.
This switches the machine Off.
2. Push and hold the OFF button for more than 3
seconds (just until all Lights flash on) then release
it. Do not hold it in it too long.
3. Examine the green Lights. They should have all
flashed once, then certain ones will have turned on
to indicate which purge level the machine is set at.
There are 5 levels of purge available:
1. Maximum Purge is when All 5 lights are
•
ON. Use for extreme water conditions. Note:
This setting may extend the Harvest cycle
and reduce capacity.
2. Heavy Purge is when these 4 lights are
•
ON: Freeze
moderate to severe water conditions. This
setting may extend the Harvest cycle and
reduce capacity.
•
3. Standard Purge (factory setting) is when
these 3 lights are ON: Harvest
Use for typical water conditions.
•
4. Moderate Purge is when these 2 lights
are ON: Clean
conditions.
•
5. Minimum Purge is when this light is ON:
. For excellent water conditions.
Off
Adjust by pushing and releasing the Freeze button.
Pushing and releasing the Freeze button increases
the purge one level up to the maximum, then it
goes to the minimum.
, Harvest, Clean,Off. Use for
, Clean,Off.
,Off. This is for good water
4. The machine will automatically restart after 60
seconds of no switch inputs, or restart the machine
by pushing in and holding the Off button for more
than 3 seconds, then releasing it. The unit will then
be Off. From there the machine may be placed in a
freeze cycle by pushing and releasing the Freeze
button.
May 2000
Page 19
Page 20
CME1056R
How To Operate The AutoIQ Controller
The AutoIQ Controller is a microprocessor based
device that receives input from several sources
and switches various components on and off.
Its manual control is thru the use of the Push
Button Control Switches
89
7
PUSH BUTTON
6
5
CONTROL SWITCHES
INDICATOR LIGHTS:
BIN FULL
4
FREEZE
3
2
1
HARVEST
CLEAN
OFF
DIAGNOSTIC LIGHTS:
WATER
REFRIGERATION
To Reset: First push and release the Off button,
then push and release the Freeze button.
Diagnostic Light Recall
To recall the last error on the blue housing CM
3
controller:
1. Switch the unit OFF by holding the OFF button
for longer than 3 seconds.
2. Hold the Off button down again until the Purge
Setting indicators (Green Lights) are on.
3. Push and release the Harvest button.
The last error code stored in the controller will be
displayed and the purge setting will disappear.
Push the Harvest button again and the
second-to-last error code will be displayed. The bin
full light will also be on to signal that this is the
second-to-last code.
Pushing the Harvest button again will display the
last error code again. Only two error codes are
available for display.
If no error code exists, no code will be displayed
and there will be NO LIGHTS showing.
To return from the display of the last error, do
nothing for 60 seconds or push and hold the Off
button.
1. Freeze Button. Pushing and releasing this
button starts or restarts the machine. The AutoIQ
Controller remembers what cycle it was last in and
returns to that cycle.
2. Harvest Button: Pushing and releasing this
button will cause the machine to go directly to a
Harvest Cycle. Can be done from Freeze or Off.
The machine will switch Off at the end of the
Harvest cycle.
3. Clean Button: Pushing and releasing this
button will cause the machine to empty the
reservoir, refill and leave only the water pump on
for circulation of ice machine cleaner. After the ice
machine cleaner has circulated for about 10
minutes a second push of this button will switch on
the rinsing system to flush out the dissolved scale
and ice machine cleaner.
4. Off Button: Pushing and releasing this button
will switch the machine OFF at the end of the next
cycle. If the button is pushed and HELD for more
than 3 seconds, the unit will switch off
immediately.
After returning from the display of the last error
(Off light glows), the machine may be returned to
the ice making process by pushing and releasing
the Freeze button.
March 2003
Page 20
Page 21
CME1056R
r
How The Electronic Cuber Works
This section is intended for the technician. It is not necessary for the normal operation and maintenance
of the machine.
Refrigeration System:
The refrigeration system is similar to that of most
commercial cube ice machines. Heat is removed
from the water and discharged out the condenser
during the freeze cycle. As liquid refrigerant
passes thru the Thermostatic Expansion Valve, it
enters the top of the evaporators, and ice will form
at the top first.
When cubes need to be released (Harvest) the Hot
Gas Valve is opened and Hot discharge gas flows
directly from the compressor to the evaporator
inlets. At the same time, a Harvest Bypass Valve
opens for a few seconds to add the refrigerant
needed for harvest. After that the Harvest Bypass
Valve and the closed Discharge Check Valve
keeps the refrigerant in the condenser out of the
Hot Gas Circuit.
Harvest
Bypass
Valve
Process
Port
Discharge Line
Receiver
Check
Valve
Remote Condenser
Head
Pressure
Control
Valve
Check
Valve
Suction
Heat
Exchange
This warms up the evaporators and the surface of
the ice frozen to the evaporator surface melts. Ice
then falls into the bin.
The Check Valves also prevent liquid migration
during the Off cycle.
Thermo Exp. Valve
Distributor
Evaporato
Evaporator
Compressor
Accumulator
Hot Gas
Valve
Refrigeration Schematic
May 2000
Page 21
Evaporator
Page 22
CME1056R
How The Electronic Cuber Works
Water System:
Freeze:
The water pump forces water to the top of the
evaporators. The un-frozen water falls thru the
cube deflectors and back into the reservoir. As
water is turned into ice, the water level in the
reservoir falls, and the machine will re-fill the
reservoir once during the freeze cycle.
At the point where the cubes are fully formed, the
water level sensor indicates to the AutoIQ
Controller that it is time to begin the Harvest cycle.
Harvest:
At the beginning of Harvest, the water pump shuts
off and the purge valve opens. The purge valve
remains open for 40 seconds. No water will drain
until the water pump restarts. The water pump will
start at a variable time depending upon the amount
of water rinse that has been set.
After the purge valve has closed, the inlet water
valve opens and water flows into the ice machine.
The water valve will NOT be open the complete
length of the harvest cycle.
The inlet water valve will “top off” the reservoir at
the beginning of the next freeze cycle.
The AutoIQ Controller operates the ice machine by
monitoring several input measures and switching
various loads on and off.
Controller Inputs:
1. Reservoir water temperature. This is
measured by a thermistor located in the water
pump outlet.
2. Discharge line temperature. This is measured
by a thermistor located on the compressor
discharge line.
3. Water level. This is measured by an infrared
sensor and float. The float rises and falls with the
water level, and switches the sensor on and off as
it moves.
4. Bin fill level. This is measured by a set of
electric eyes in the cube outlet port. If ice fills the
bin, it will block the “eyes".
Some units are equipped with a bin thermostat,
those units use the thermostat to switch the
machine on and off. The electric eyes in the cube
outlet port will also control the machine if the bin
thermostat sticks in an ON position.
5. Time. The controller measures and compares
how long it takes for various events to happen. It
stores that data for future reference.
Controller Outputs:
A. 24 volt:
•
1. Lights
•
2. Inlet water valve
•
3. Hot Gas Valve
•
4. Contactor Coil
•
5. Harvest Bypass Valve Coil
B. High Voltage
•
1. Water Pump
•
2. Purge Valve
May 2000
Page 22
Page 23
Technicians Only: Freeze Cycle Sequence
CME1056R
Assuming the machine has been operational, the
Freeze cycle begins with the end of the Harvest
Cycle:
Water Inlet Valve is Closed
•
Water Pump is ON
•
Compressor is ON
•
Hot Gas Valve is Open
•
AutoIQ Controller Operation, Beginning
freeze:
1. Switches on Freeze indicator light and shuts off
the hot gas valve.
2. Opens the water valve to top off the reservoir.
The controller checks that water fills the reservoir,
if it does not fill up within 250 seconds, the
controller shuts the machine down. It will
automatically try to restart in 20 minutes.
3. Measures and stores the discharge
temperature.
4. If the discharge temperature exceeds the design
maximum, shuts the machine down on a
Refrigeration Error.
5. Checks for a “bin full" signal throughout the
cycle.
6. Measures the reservoir water temperature. If the
machine is operating correctly, the reservoir water
temperature will fall at a standard rate. The AutoIQ
Controller will be checking to see if the water
temperature fall matches that rate.
If not, it re-checks the discharge line temperature.
If too low, it Shuts Down on a Refrigeration Error. If
the discharge temperature is acceptable, the water
system is checked by shutting off the water pump
and determining if the water level goes up enough.
If it does not, the inlet water valve will open again
to fill it. If, after restarting, the water level does not
drop, it is assumed that there is a water pump
problem and the machine Shuts Down on a Water
Error.
If the water level does “measure up" the water
pump is restarted and the AutoIQ Controller then
measures how long it takes to lower the water
level. If the water level does not fall, the machine
Shuts Down on a Water Error.
8. As the machine makes ice, the water level in the
reservoir will ultimately fall to the Harvest Level.
The first time that happens per freeze cycle the
inlet water valve is re-opened and the reservoir is
refilled. The next time it happens, the unit will go
into a harvest cycle.
Note: If the freeze cycle exceeds the preset
Maximum (30 minutes), the Controller will Shut
Down the machine and switch on the Refrigeration
Light.
9. The end of Freeze cycle will see the machine in
this state:
Water level = below harvest position
•
Water inlet valve will be off
•
Water pump will be ON
•
Compressor will be ON
•
Hot gas valve will be off
•
At this point Harvest begins and the AutoIQ
Controller switches the Harvest indicator light ON.
Restarts:
If the machine is restarting after it has shut off
because the bin was full, the first freeze cycle
sequence is like this:
1. Purge valve is open.
2. Pump starts.
3. Purge valve closes.
4. Water valve opens to fill the reservoir.
5. Compressor starts.
Note: If there is a power interruption, after power is
restored the machine will restart, go thru a brief
Freeze cycle and go thrua6minute Harvest cycle.
Error Restarts:
The machine automatically attempts to restart 50
minutes after a shut down. If another problem
occurs in the next cycle, the machine will attempt
one more restart. If another problem occurs in the
next cycle, the machine will shut off and must be
manually reset.
7. Once per freeze cycle the machine will shut off
the water pump. It only does this when the water
temperature reaches a preset minimum. The pump
will only be off for a few seconds.
May 2000
Page 23
Page 24
CME1056R
Technicians Only: Harvest Cycle Sequence & Other Notes
Harvest
The Purge Valve will be open for 40 seconds.
The water pump shuts off, it will restart before 40
seconds, the restart time is based on the Purge
Level Setting.
The pump restarts and pumps water out of the
reservoir until the purge valve closes.
The inlet water valve will stay on for about 9
seconds to add enough water to assist with
harvest.
The Hot Gas Valve will be open for the entire
length of the Harvest Cycle.
The Harvest Bypass Valve will be open for a few
seconds at the beginning of the Harvest Cycle.
During the Harvest Cycle, ice will be falling from
the evaporators and between the ice sensor’s
electric eyes. The Controller monitors the ice
falling and uses that information to determine the
next harvest cycle length.
Bin Thermostat:
In normal ambients the thermostat will react to ice
on the bulb in a few seconds. Reaction after
removal will take about a minute under normal
conditions, and longer in colder rooms.
Stacked Units:
If the bottom unit is in harvest and receives a
signal from the top unit that it is also in Harvest,
the bottom unit will stay in harvest for about 6
minutes.
If the bottom unit is shut off, but its controller still
has power, the top unit may continue to operate. If
the bottom unit’s power is shut off, the top unit will
shut down on bin full at the end of the next cycle. If
the top unit’s power is shut off, it does not impact
the bottom unit.
An error shut down on one unit does not affect the
other.
Either one may be switched off at the controller
without impacting the other.
The first Harvest after a restart will take about 6
minutes to establish a base line, then the time it
took to release that ice is used to determine the
next harvest cycle’s length.
The maximum harvest time is 14 minutes.
If no cubes fall (or are sensed) by the end of the
Maximum Harvest Time, the machine senses a
Refrigeration error. If the next cycle also produces
a Refrigeration error, the machine will shut down.
Note: The last Harvest cycle before shutting off on
Bin Full will be about 6 minutes long.
Note: The machine will not restart for 4 minutes
after switching off on Bin Full, unless the Freeze
button is pressed.
Bin Full: The controller will switch on the
compressor for 30 seconds after 12 hours of off
time to keep refrigerant out of the compressor oil.
Continuous Run Time
A unit that operates 24 hours a day 7 days a week
is too small for the user’s needs. To maintain
harvest integrity, the controller will extend the
harvest time to 6 minutes every 15th consecutive
harvest cycle.
Diagnostic Light Code Table
If a Diagnostic
Light
Blinks once and
repeats
Blinks twice and
repeats
Blinks three
times and
repeats
Is ON all the
time
Both ON all the
time
Water Light
Water pump will
not start
Lack of water fill
not used
Water valve
leaking thru
rapidly
Check for thermistor set unplugged
or failed
Note: Diagnostic lights remain on until the
controller is manually reset or until it successfully
restarts the machine.
Refrigeration
Light
Very long ice
harvest
No harvest of
ice
High Discharge
Temperature
Check for low
discharge
temperature or
long freeze
cycle
May 2000
Page 24
Page 25
CME1056R
Sanitation and Cleaning
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition.
Without human intervention, sanitation will not be maintained. Ice machines also require occasional
cleaning of their water systems with a specifically designed chemical. This chemical dissolves mineral
build up that forms during the ice making process.
Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine
is cleaned and sanitized.
The ice machine’s water system should be cleaned and sanitized a minimum of twice per year.
In Place Cleaning of the Ice Machine Water
System:
1. Remove all ice from the bin. Either save it in a
sanitary container or discard it. If the cleaning was
planned, the ice machine could be switched off the
night before to minimize waste.
2. Remove the front panel.
3. Push and release the Harvest button (this releases
any ice that may be on the evaporators and warms
them up).
4. Wait for the machine to finish the Harvest cycle
(the machine will stop).
5. Remove the cube deflector, the evaporator cover,
the cascading shield (if used) and the bin control
sensors. Place the cascading shield and the cube
deflector in a separate container. Place the bin
controls in the reservoir.
6. Push and release the Clean button. The Clean
indicator light will be blinking, and the pump will
restart.
7. Pour 12 ounces of Scotsman Ice Machine Cleaner
into the reservoir water. Return the evaporator cover
to its normal position.
8. Mix a solution of 8 ounces of Scotsman ice
machine cleaner and 1 gallon of warm (95-115oF.)
water. Use the solution to scrub the cascading shield
and cube deflector in the separate container.
Scotsman Ice Machine
Cleaner contains acids.
Acids may cause burns.
If concentrated cleaner
comes in contact with skin,
flush with water.
If swallowed, do NOT
induce vomiting. Give large
amounts of water or Milk.
Call Physician
immediately. Keep out of
the reach of children.
9. After the ice machine cleaner has circulated for 10
minutes, push and release the Clean button. This
starts the rinsing process. The Clean indicator light
will be ON. Note: The rinse process flushes any
residual cleaner out of the ice machine’s water
system.
10. Continue the rinsing process for 20 minutes, then
push the off button to switch the machine off.
11. Go to the next step to sanitize the machine or go
to step 19 to finish the cleaning process.
12. Mix 2 gallons of Sanitizer solution. Follow local
codes for Sanitizer.
Note: A possible sanitizing solution may be made by
mixing 1 ounce of liquid household bleach with 2
gallons of warm (95-115oF.) potable water.
13. Push and release the Clean button again.
14. Pour 16 ounces of Sanitizer solution into the
reservoir water.
15. After the solution has circulated for 10 minutes
push and release the Clean button. This starts the
rinse process. Sanitize the ice storage bin while
waiting.
16. Continue the rinsing process for 20 minutes, then
push the off button to switch the machine off.
17. Remove the evaporator cover and spray or wash
all interior surfaces of the freezing compartment
including the evaporator cover with sanitizer solution.
18. Thoroughly immerse the cascading shield and
cube deflector in the sanitizing solution.
19. Return the bin controls, cascading shield and
cube deflector to their original positions.
20. Return the evaporator cover to its original
position. Push and release the Freeze button.
21. Return the front panel to its normal position
and secure it to the machine with the original
screws.
December 1998
Page 25
Page 26
CME1056R
Additional Maintenance
Additional Maintenance: Water Distributors
It may become necessary to remove the water
distributors from the top of the evaporator and
clean (de-mineralize) them outside of the ice
machine.
1. Remove front panel.
2. Push and release the OFF button.
3. Remove the evaporator cover.
4. Lift the water distributors up at the center until
they snap apart.
Water Distributor
8. Return the water distributors to their normal
installed position.
9. Push and release the clean button to flush the
water system.
10. After the machine stops, push and release the
Freeze button.
11. Replace the evaporator covers.
12. Replace the front panel.
Water Level Sensor
Clean the lenses inside the water level sensor.
Water
Channels
5. Repeat for all evaporators.
6. Examine the top of the evaporators. The Water
Distribution Channels must be free from mineral
build up. If build up is evident, scrub the channels
with Scotsman Ice Machine Cleaner and a plastic
bristle brush.
7. Examine the water distributors. Although they
are made of a material that is resistant to mineral
build up, some may be present. Soak or scrub the
distributors in or with a solution of Scotsman Ice
Machine Cleaner and warm potable water.
1. Remove the sensor from its installed position.
2. Remove dust cover.
3. Wipe
lenses clean
with a cotton
swab.
Dust Cover
4. Reverse to
reassemble.
Lenses
May 2000
Page 26
Page 27
Additional Maintenance: Inlet Water Valve Screen
CME1056R
The inlet water valve has a screen on its inlet side
to keep debris from flowing into the valve. In some
cases, this screen may become clogged or
restricted by debris build up. Check for the proper
water flow:
Flow rate is 2.7 G.P.M.
1. Remove front panel.
2. Obtain a 16 ounce cup and a watch.
3. Pull the water discharge tube out of the
reservoir and place it in the cup.
4. Push and release the Harvest button.
5. If working properly, the water valve will fill an 16
oz cup in about 3 seconds. Be prepared to push
the Off button! If it does not, the water valve inlet
or other water device is restricted.
Inlet Water
Valve Screen
only be removed by taking off the covering
bracket. The bracket forms part of the inlet water
system, and must be water tight to the valve body,
removal is not recommended.
9. Reverse to reassemble.
To drain reservoir (if desired):
1. Remove front panel.
2. Push and hold the Off button.
3. Push and hold the Clean button until the
reservoir is empty.
4. Push and release Freeze button.
5. Return the front panel to its original position.
To Sanitize the Ice Storage Bin
1. Remove all ice.
2. Remove baffle.
3. Switch ice machine OFF or wait for it to be in a
cleaning cycle.
To Check the Inlet Water Valve Screen.
1. Disconnect the electrical power.
2. Shut off the water supply.
3. Remove the front panel.
4. Unplug the electrical connection of the inlet
water valve.
5. Remove the screws holding the inlet water valve
to the cabinet.
4. Mix a 1 gallon solution of warm (95-115oF.)
water and sanitizer. Follow local codes for
sanitizer.
5. Wash or spray the entire interior of the ice
storage bin with the sanitizer solution. This
includes the bottom of the ice machine and the
inside of the door, the door gaskets (if any) and
door frame.
6. Pour excess sanitizer into the bin to flush the
drain system.
7. If the approved sanitizer requires a rinse, rinse
all interior surfaces with potable water.
6. Remove outlet tube from inlet water valve.
7. Rotate inlet water valve from inlet fitting and
remove valve from machine.
8. Examine the inlet screen, if dirty, brush off
screen. Note: Screen is not replaceable, and may
May 2000
Page 27
Page 28
CME1056R
Additional Maintenance: Ice Sensors, Condenser
The ice sensors use a system of infrared emitting
and receiving components to sense the build up of
ice in the bin. They are located at the bottom of
the ice outlet port. They must be free of mineral
build up to function properly. To check:
1. Remove front panel.
2. Push and release the harvest button.
3. Wait for the machine to stop.
4. Remove the evaporator cover.
5. Locate the front ice sensor.
Push the sensor from the front (at the wire area) to
the back until it releases from the holder.
6. Locate the back ice sensor Pull on the
rectangular tab to release it from its mounted
position.
Ice Sensor
Lens
Cube
Deflector
Cascading
Shield
Ice Sensor
To Clean the Remote Air Cooled
Condenser
1. Disconnect and lock out the electrical power.
7. Examine the bottom of the brackets, there are
two sensors in each bracket, check that they are
clear of mineral build up. They may be wiped clean
with ice machine cleaner to assist in removal of the
build up.
Note: Do NOT use abrasive materials or cleaner
on the ice sensor lenses. A soft toothbrush works
well to get into the hard to reach spots.
8. Reverse steps 1-6 to reassemble.
2. At the remote condenser, check for loose debris
on the roof, remove any near the condenser.
3. Check the fan blade and condenser for grease
or dust build up. Brush the intake surfaces
(outside) of the condenser coils with a nylon brush
to remove surface dirt. Use a fin comb to
straighten any bent fins.
Note: Air flow is UP, towards the fan.
If grease is present, use coil cleaner on the
condenser. Be sure to wipe up any excess coil
cleaner.
4. Reconnect the electrical power.
May 2000
Page 28
Page 29
Service Diagnosis: Diagnostic Light Analysis
Problem or SymptomPossible CauseProbable Correction
Machine is offBin is fullUse some ice
CME1056R
Unit is off on a Water
Error
Bin full light is ON, no ice in
cube port
Bin thermostat is closedCheck thermostat
Power is off, check Lights.If all Lights are out, check power supply,
Transformer is openIf all Lights are out and there is power, check
Unit has been switched off
or has finished a Clean
cycle, Off Light is glowing
Unit has Shut DownCheck for Refrigeration or Water Error
Water supply inadequateCheck water Light, if the Light blinks 2 times
Water pump malfunctionCheck that pump hose is attached and if
Water level sensor may
have failed.
Check optional thermostat, check ice sensor
lens for scale.
restore power if off
transformer output for 24 vac
Push and release Freeze button
and repeats, check the water inlet valve for
proper water flow.**
pump is plugged in and working.
Check float stem, reset machine. If it will not
reset or gives another water error and
everything else is OK, replace the water level
sensor.
Unit is off on a
Refrigeration Error
Unit runs and both
Diagnostic lites are
ON
Low discharge or long
freeze cycle
Harvest problemCheck refrigeration Light. If the Light blinks
High Discharge TempCheck refrigeration Light. If the Light blinks 3
Unit does not go into
harvest - exceeds
maximum freeze time
Exceeds maximum harvest
time
Temperature sensors out
of range
Check refrigeration Light. If the Light is
glowing, there is a probable refrigeration
problem - fan motor could have failed.
once and repeats, look for a harvest problem.
where some cubes were sensed.**
Check refrigeration Light. If the Light blinks
two times and repeats, look for a harvest
problem. - no cubes sensed**
times and then repeats, check for a reason for
high discharge temperatures - fan motor hot
ambient.
Push and release Off button. Push and
release Freeze button. Check operation.
Push cube size float down and check
operation.
Check for cause of long harvest cycle**
Replace the temperature sensor set (water
and discharge).
May 2000
Page 29
Page 30
CME1056R
Service Diagnosis
Problem or SymptomPossible CauseProbable Correction
Unit is off because of a
“Harvest Problem”
Cubes are too largeCube size control float is
Cubes are too smallNot enough waterCheck for leak in reservoir
Low ice capacityDirty condenserClean condenser
Ice sensors did not sense
ice falling, unit stayed in
harvest until the maximum
harvest time ran out.
Bin controls or AutoIQ
Controller may have failed.
Other components may
have failed
sticking.
Inlet water valve leaking
thru (slowly)
Check ice sensors. If the bin full light is on or
blinking the bin controls may be dirty. Clean if
dirty. The board and bin controls may also
need to be checked.
Check evaporators for lime scale build up.
Clean evaporators and bin controls if dirty.
Push and release Off button. Push and
release Freeze button. Check machine
operation. Check if ice is made and harvests.
See “Unit does not shut off” below..
Check the next page
Check/clean
Check hose from water valve for slow drip.
Replace valve if dripping.
Check for a leak thru the purge valve
Recirculation of airBlock air re-circulation or move condenser
Low refrigerant chargeCheck system. If there is a low charge, find
Too much waterCheck for inlet water valve leak thru
Unit does not shut offIce sensing system may
have failed.
the leak, recover the refrigerant, repair the
leak, replace the dryer, evacuate and weigh in
the nameplate charge.
Check controls. Unplug thermostat and check
bin full light, if off, place something between
the electric eyes. The bin full light should
begin to blink (after 20 seconds of continuous
blockage it will glow steadily). If not, check
operation of electric eyes by unplugging #4
and jumping out the two pins on the controller
(touch the tool to the cabinet to discharge
static electricity before contacting the
controller). If the bin full light blinks, replace
the bin controls. If it does not blink, replace
the controller. Note: Leaving #4 unplugged
and jumped for 20 seconds will shut the
machine down on a bin full (at the end of the
harvest cycle). It will restart after 4 minutes or
may be reset by pushing the Freeze button.
May 2000
Page 30
Page 31
Service Diagnosis: Components
Problem or SymptomPossible CauseProbable Correction
CME1056R
Fan motor does not
turn.
Pump motor does not
turn
Hot Gas Valve does
not open.
Hot Gas Valve leaks
thru (warm tube
temperatures on both
sides of valve during
freeze)
Water Inlet Valve does
not open
Open motor windings, or
seized bearings
No power to fan motorContactor may not close.
Open motor windings, or
seized bearings
No power to pumpCheck electrical connections. In Freeze, the
Open solenoid coil.Replace hot gas valve
Stuck valveReplace hot gas valve
No power to coil in HarvestCheck wire connections, if ok, replace AutoIQ
Mechanical problem in
valve
Open solenoid coilReplace valve
Stuck valveReplace valve
Replace fan motor
Replace pump
pump should have power to it. If not, replace
the AutoIQ Controller.
Controller
Replace valve
Water Inlet Valve does
not flow enough water
Water Inlet Valve
leaks thru
Compressor does not
work
No power to valve (best
checked at the beginning
of Freeze)
Restriction in water supplyCheck water filters and/or inlet screen.
Mechanical problem in
valve
Unit in Clean cyclePush and release Freeze button.
Contactor coil openReplace contactor
Open starting componentsCheck and replace
Open windingsCheck and replace compressor
Internal valve failureReplace compressor
Check wire connections, if ok, replace AutoIQ
Controller
Replace valve
May 2000
Page 31
Page 32
CME1056R
Service Diagnosis
Problem or SymptomPossible CauseProbable Correction
Poor HarvestScale in water system.Clean water system.
Water or Air Temperatures too
cold
Low system chargeRecover and weigh charge.
Bypass solenoid does not openCheck solenoid operation
Check valve leaks backReplace check valve
Hot gas valve does not openCheck for power to the coil, if
Head pressure control valve
does not maintain enough
pressure (in freeze)
Low capacityHigh discharge pressure, from a
dirty condenser or faulty fan
motor
Extreme hot locationRelocate the cabinet
Extremely hot condenser
location
Overcharge of refrigerantRecover, evacuate and weigh in
Check temps. Unit cannot
operate with water and air
temps below stated limits.
there is power, replace the hot
gas valve
Replace the head pressure
control valve
Clean the condenser, repair the
fan motor
Move condenser or provide
shade
the nameplate charge
Hot gas valve leaks thru, unit off
on refrigeration error
Liquid and discharge lines are
in contact with each other
Compressor cycles on and offCompressor overheatsLow on refrigerant, locate leak,
At the end of the freeze cycle,
there should be a definite
difference in temperature
between the inlet and outlet of
the Hot Gas Valve. If not,
replace the hot gas valve
Separate and insulate them
recover refrigerant, repair leak,
replace drier, evacuate and
weigh in the nameplate charge.
TXV superheat too high, check
charge, if charge is OK, replace
TXV
Mechanical fault with
compressor, replace
compressor
Internal relief valve opened,
check for cause of high
discharge pressure
May 2000
Page 32
Page 33
PTCR Diagnosis
CME1056R
The CME1056 “D” series cubers use a PTCR
(Positive Temperature Coefficient Resistor) in
place of a conventional start relay and start
capacitor.
Power from the contactor connects to the
•
PTCR and to the Run Capacitor
A wire connects the other terminal of the
•
PTCR to the compressor’s start winding.
Another wire connects the run capacitor to
•
the start winding.
A parallel circuit connects power from the
•
contactor to the Run winding of the
compressor.
A PTCR changes resistance sharply when its
temperature changes. When the PTCR is cold, it
connects full current to the compressor’s start
winding. After a very short time, the PTCR heats
up and shuts off the current flow. Under normal
conditions, the PTCR’s case is at about 180
o
F.
At that temperature the PTCR has very high
resistance and will not allow current to flow. It must
cool down to about 120
o
F. Before current will pas
through it again.
Diagnosis:
1. Disconnect electrical power.
2. Check if the PTCR is cool enough to handle
safely. If not, wait 5 minutes for it to cool off.
3. Disconnect both leads to the PTCR and
measure its resistance with an ohmmeter. If the
PTCR reads less than 22 ohms or more than 40
ohms, replace it.
May 2000
Page 33
Page 34
CME1056R
Operational Characteristics: CME1056R
Cycle Times:
70oF. condenser air 70oF. indoor
o
air, 50
Freeze12 to 15 minutes14 to 17 minutes
Harvest2 ½ minutes2 minutes
F. water
o
F. condenser air 90oF. indoor
90
o
air, 70
F. water
System Pressures (PSIG) (minutes):
70oF. condenser air 70oF. indoor
o
air, 55
Suction: End of Freeze24 to 30 PSIG26 to 32 PSIG
Suction: Peak in Harvest90 to 110 PSIG110 to 130 PSIG
Discharge: 5 minutes into Freeze225 to 245 PSIG250 to 270 PSIG
F. water
o
F. condenser air 90oF. indoor
90
o
air, 70
F. water
Number of Evaporators:
3
•
Refrigerant Charge
•
208 ounces of R-404A
Typical Compressor Amps,
single phase
•
10 freeze
•
10 harvest
Typical Compressor Amps,
three phase
•
7 freeze
•
7 harvest
Typical Harvest Ice Weight
•
9to11lb.
Superheat
•
5 to 15 degrees
Hi Pressure Control - Automatic Reset
•
Hi Pressure Cut Out - 450 PSIG
•
Hi Pressure Cut In - 350 PSIG
Headmaster Valve
•
Setting is 217 PSIG
May 1999
Page 34
Page 35
Removal and Replacement
CME1056R
Inlet Water Valve
1. Remove the front panel.
2. Shut off the water supply.
3. Push and release the OFF button.
4. Pull the wire harness off the inlet water valve.
Water Valve
Water Pump
1. Disconnect the electrical power.
2. Remove the front panel.
3. Unplug water pump from its electrical
connection.
4. Remove 1 plastic bolt and the reservoir cover.
5. Lift water pump up and disconnect outlet tube.
6. Pull float ball from float stem (it is a snap fit).
Pull stem out.
Water Level
Sensor
5. Remove screws holding the inlet water valve to
the cabinet.
6. Pull the valve away from the cabinet and
disconnect the outlet tube.
7. Unscrew the water valve from the water inlet
tubing. Hold the barbed inlet fitting and rotate the
valve.
8. Reverse to reassemble.
9. Push and release the Freeze button.
10. Replace the front panel.
Water Pump
7. Locate water level sensor mounting tabs,
compress together to release sensor from bracket.
8. Remove water pump brackets from pump.
9. Reverse to replace.
10. Replace front panel.
11. Re-connect electrical power.
May 2000
Page 35
Page 36
CME1056R
Removal and Replacement
Purge Valve
1. Disconnect electrical power.
2. Remove front panel.
3. Unplug wire harness from purge valve coil.
4. Locate and remove the two screws securing the
purge valve to the machine.
Purge Valve
Purge Valve Timer
The purge valve timer is sensitive to electrostatic
discharge. Be certain to touch a grounded surface
before touching this component. Do the same
when handling the replacement part.
1. Touch a grounded surface.
2. Remove front panel.
3. Disconnect electrical power.
4. Remove high voltage box cover.
5. Locate timer board at the bottom of the high
5. Pull the inlet and outlet hoses off the purge
valve and remove it from the machine.
6. Reverse to reassemble. There are no internal
parts available for this valve.
Purge Valve
Timer
voltage box.
6. Unplug all the wires to the board.
7. Compress each of the four stand-off posts to
release the board from the stand-offs.
8. Remove the board from the unit.
Reverse to reassemble.
May 2000
Page 36
Page 37
Removal and Replacement: AutoIQ Controller
10. Push and release the Freeze button.
11. Replace the front panel.
Electric Eyes (Ice Sensors)
Electrical Shock Hazard
Disconnect Electrical
Power Before Beginning
1. Disconnect the electrical power.
2. Remove the front panel.
3. Remove mounting screw holding controller to
cabinet.
Cascading
Shield
Ice Sensor
CME1056R
4. Touch a metal surface to discharge any static
electricity.
5. Pull controller out slightly and unplug all
electrical connections.
Note: Do NOT touch the back of the controller.
6. Carefully remove the new controller from its
packaging. Again, do NOT touch the back of the
controller.
7. Plug all electrical connectors into the new
controller.
These must be replaced as a set.
1. Remove front panel.
2. Push and release the Off button.
3. Remove evaporator cover.
4. Remove cascading shield.
5. Locate the left and right ice sensors. Each has a
rectangular tab that was holding the cascading
shield. Pull on that tab until each sensor has been
removed.
6. Unplug sensors from controller connections 3
and 4.
7. Remove sensors from machine. Note: Some
cable ties may have to be cut and side panels
removed.
8. Reverse to reassemble. Be sure that the color
codes of the connecting wires match.
8. Re-attach the controller to the cabinet.
9. Switch on the electrical power. All Lights should
lite up.
May 2000
Page 37
Page 38
CME1056R
Removal and Replacement: Water Level Sensor
1. Remove front panel.
2. Push and hold the OFF button. Release it when
the machine stops.
3. Trace wire harness from water level sensor to
the Controller (#2). Unplug the harness from the
controller.
Water Level
Sensor
4. Lift the pump and mounting plate up enough to
remove the float from the stem.
Water Temperature Sensor
Note: This sensor is replaced as a set with the
Discharge Temperature Sensor.
1. Remove left side and front panel.
2. Push and release Off button.
3. Remove 1 plastic bolt and the reservoir cover.
4. Locate water temperature sensor (inserted into
pump discharge hose).
5. Pull out to remove.
6. Trace back to AutoIQ Controller, unplug from
#5.
7. Remove the Discharge Line temperature
sensor.
8. Reverse to reassemble.
Note: Do not push sensor tip in too far. There
should be about an 1/8" gap between the tip and
the inner wall of the water discharge hose.
5. Remove two screws holding the sensor to the
pump bracket and lift the sensor up and out of the
machine.
6. Reverse to reassemble.
Discharge Line Temperature Sensor
1. Remove front panel, push and release the Off
button.
2. Remove top and left side panels.
3. Locate discharge line sensor. It is attached to
the discharge line of the compressor, 6" from the
compressor discharge port.
4. Un-snap the clip holding the sensor to the
discharge line.
5. Trace the sensor wires back to the controller,
they are plugged into #5 with the water
temperature sensor, and must be replaced with it.
6. Reverse to replace, be sure that the discharge
line sensor is 6" up from the compressor discharge
port. The discharge line sensor is marked with
yellow tape.
Note: Route wires so they do NOT contact the
discharge line.
May 2000
Page 38
Page 39
Removal and Replacement
CME1056R
Transformer and Compressor Starting
Components
Single phase compressors use a start relay, start
capacitor and run capacitor. All are located in a
sheet metal box to the right of the AutoIQ
Controller. The compressor contactor is also
located in that box.
1. Disconnect electrical power.
2. Remove front panel.
3. Remove 2 screws at the front edge of the metal
box, and pull the cover forward and out.
4. To check components, reconnect electrical
power.
Note: The contactor coil is 24 volt.
Evaporator Support Bracket
In the unlikely event that the evaporator support
bracket needs to be replaced, two people will be
needed.
1. Remove both front panels and the top panel.
2. Push and hold the Off button until the machine
stops.
3. Remove evaporator cover.
4. Remove the interior splash panels.
5. Remove the hoses from the water distributors.
6. Use wire ties to hang the front of the
evaporators from the upper cross brace.
7. Place a clean rag under the planned cut point
and saw the old bracket in half and remove it.
8. While holding the bracket so that the right end is
higher than the left, insert the right end in the
vertical channel in the right side of the freezing
compartment.
10. Check that all evaporators are properly seated
front and back.
11. Remove the wire ties, and return the splash
panels, hoses, and evaporator cover to their
normal positions. Check that water distributors are
in place.
12. Push and release the Freeze button to start the
machine.
13. Check operation.
14. Return the top and front panels to their normal
positions.
Refrigeration System Components
Due to the expected level of training and
experience of a refrigeration mechanic, detailed
instructions regarding the replacement of
refrigeration components will not be presented.
However, critical items will be noted here.
Evaporators
In the unlikely event that an evaporator may need
to be replaced, do NOT braze the evaporator joints
when the evaporators are seated in the freezing
compartment, instead lift them up slightly so that
the joints to be brazed are above the top edge of
the freezing compartment.
Compressor
The compressor should not be replaced until it has
been determined that it has definitely failed. If it will
not start check the starting components first. If the
machine has low capacity, check for proper
charge, TXV operation, hot gas valve leak thru or
inlet water valve leak thru.
The metal bracket in front of the compressor must
be removed to access the compressor.
Then, while the helper lifts the right-most
evaporator slightly, push the bracket in from below.
Keep doing this and push up on the left end of the
new bracket.
The freezing compartment walls may be pushed
apart slightly to make this easier.
9. Push up enough on the left end of the bracket
until it snaps into the vertical channel in the left
side of the freezing compartment.
May 2000
Page 39
Page 40
CME1056R
Refrigerant
1. This ice machine uses R-404A or HP62 as a
refrigerant. It has several unique characteristics.
A. It is a near-azeotrope, and must be liquid
charged.
B. It must use polyol ester refrigerant oil, and that
oil is very water absorbent. The system must not
be open for more than 15 minutes.
C. An electronic leak detector capable of locating
HFC-134a type refrigerant must be used to locate
refrigerant leaks.
D. A special HFC type liquid line dryer must be
used.
E. When brazing, a dry nitrogen purge is required.
F. When evacuating, use of an electronic micron
gage is recommend. Evacuate to 300 microns.
Recovering the Refrigerant
Because of the check valves, liquid refrigerant
must be recovered thru the liquid line valve and
the low side access valve.
1. Low Side: Remove the stem cap and insert a
3/16" allen wrench. Check that the valve is closed.
4. Recover the refrigerant using the normal
techniques for the recovery machine used.
Evacuation
Evacuate to 300 microns
Charging
1. Use an electronic scale to measure the charge.
2. Place a drum or cylinder of R-404A on the scale
in position to dispense liquid refrigerant.
3. A refrigeration manifold is assumed to be
attached to the service access valves. Attach the
charging hose to the cylinder of R-404A. Open the
cylinder’s valve and purge the hose to the
manifold.
4. Be sure that the low side access valve is closed.
5. Open the discharge side manifold valve and
weigh in the name plate charge. After the charge is
weighed in re-check the scale.
Liquid Charging
6. If all of the refrigerant charge has not been
weighed into the discharge side, it must be
carefully added thru the low side. Close the
discharge service access valve.
Liquid Line
Valve
Liquid Line: Remove the stem cap. Use a
refrigeration wrench and check that the valve stem
is fully UP or OUT. If recovering, remove the
schrod core before opening the valve.
2. Remove the port caps and attach refrigerant
manifold hoses.
3. Open the valves. Note: Open liquid line valve
half way to access both sides of the liquid line.
7. With a sight glass or charge faster in the hose to
the low side port, start the ice machine.
8. Open the low side service access valve.
9. Crack open the low side manifold valve and
watch the scale and sight glass. Open and close
the low side manifold valve to flow liquid into the
manifold but flash off to vapor before it enters the
suction side of the refrigeration system.
10. After the scale = the correct charge, shut off
the valve on the refrigerant cylinder.
11. With the ice machine running and the
discharge access valve closed, open both manifold
valves to allow the refrigerant in the hoses to enter
the system.
12. Shut the suction service access valve.
13. Remove the refrigeration manifold gages.
14. Replace and tighten all caps.
May 2000
Page 40
Page 41
CME1056R
Before Calling for Service
Check the following:
1. Has the water supply to the ice machine or building been shut off? If yes, the
ice machine will automatically restart within 25 minutes after water begins to
flow to it.
2. Has power been shut off to the ice machine? If yes, the ice machine will
automatically restart when power is restored.
3. Did the remote condenser’s fan stop turning? If yes, the ice machine may
need to be manually reset.
4. Does the bin control have ice on it? If so, remove the ice and the machine
should start in a few minutes.
To Manually Reset the machine.
1. Remove the front panel.
2. Locate the AutoIQ Controller. If a red
diagnostic light is glowing, note which one
and its blink rate. Then push and release the
off button.
3. Push and release the Freeze button.
4. The machine should begin to operate. If
there is a lack of water it will soon shut off
again.
5. Return the front panel to its normal
position.
If the machine shuts down again, call for
service.
To Shut the Machine Off:
89
7
PUSH BUTTON
6
5
4
3
2
1
CONTROL SWITCHES
INDICATOR LIGHTS:
BIN FULL
FREEZE
HARVEST
CLEAN
OFF
DIAGNOSTIC LIGHTS:
WATER
REFRIGERATION
1. Remove the front panel.
2. Locate the AutoIQ Controller.
3. Push and hold the Off button for 3
seconds or until the machine stops.
May 2000
Page 41