SciCan StatClean User Manual

1
StatClean - Ultrasonic Cleaner
USER MANUAL
FEATURES:
Large Tank Capacity Tank capacity 6.0 L / 1.6 gallon.
Tank size: 32.5 x 20.5 x 9.9 cm / 12.7” x 8.1” x 3.9”
Large Tank Capacity Patented design, basket can be raised and suspended to
Control panel with capacitive sensing technology
Solid panel top. Durable, reliable, resistant to water and harsh chemicals.
Drainage valve Convenient to use.
Two industrial grade ultrasonic transducers
Uniform distribution of ultrasonic waves, strong cleaning, high durability.
Two ceramic heaters Mounted underneath the bottom of the tank for safe and
even heating; more durable construction.
3-color LED display 1 to 30-minute full range timer, 5 temperature settings, actual
temperature thermometer, degas and solution usage timer.
Independent control circuit for each ultrasonic transducer
40% higher cleaning efficiency, not susceptible to interference, more durable.
Multiple circuit protectors When overloaded or improperly used, the protectors shut
down the power to certain areas to protect the machine.
Moisture-proofed PCB with industrial IC
Capable for different working environments with better anti­interference performance.
Two cooling fans One for cooling of PCB boards, one for cooling of ultrasonic
transducers. Improve heat dissipation and beneficial for continuous operations.
Multiple optional accessories Suspendible plastic basket, stainless steel rack and tray,
indirect cleaning tank, beaker and double beaker holder.
Solid and advanced structural design
4.5 mm thick wall housing made from engineering grade plastic with tongue-in-groove design for better waterproof and drop-proof performance.
SD-485 US EN R1_StatClean user manual.indd 1 2016-06-09 12:58 PM
2
Use filtered water for best results.
PRINCIPLES OF ULTRASONIC CLEANING
Millions of tiny air bubbles are generated within liquid by high frequency vibration. The air bubbles burst when in contact with object and dislodge the debris to achieve the cleaning effect.
Using tap water is sufficient; however, it is recommended to use filtered water for best results.
Main Features
• Tank opening 32.5 x 20.5 x 9.9 cm / 12.7”x 8.1”x3.9”.
• Longest item that can fit inside the tank is 34.0 cm / 13.4”. 6.0 L / 1.6 gallon tank capacity.
• Multiple options for accessories, suitable for various applications.
• 2 industrial grade ultrasonic transducers: 2 x (55~60)W=(110~120)W.
• 2 ceramic heaters: 2 x (78~87)W=(156~174)W.
• 3-color LED display, 7-key controls, 6 quick timer settings, adjustable to any minute between 1-30 minutes, 5 temperature settings in both F and C, simple and straightforward to operate.
• Control panel with capacitive sensing technology. Durable, reliable, resistant to water and harsh chemicals. * Advanced power-off memory that recalls last timer and temperature settings
• Electrical circuit features:
1. Two stack transducers, each has an independent PCB control. The output power is
increased by 40% compared to less expensive control method that uses one PCB to control multiple transducers. Stack transducer is about twice more powerful and durable than wafer transducers
2. Multiple circuit protectors:
a. Thermal switch to prevent running dry. If temperature is too high, the switch cuts off
power for approximately 6 minutes then reconnect the power. b. Thermal protector to prevent PCB from overheating due to overload. c. Timer to prevent heater from running continuously.
• Industrial grade IC. Moisture-proofed PCB. Cooling fan.
• Drainage valve.
Read the Manual First
The manual should be carefully reviewed before starting to use the device. Warnings should be observed carefully. Please follow the manual for operations.
INTRODUCTION
SD-485 US EN R1_StatClean user manual.indd 2 2016-06-09 12:58 PM
3
TABLE OF CONTENTS
SAFETY PRECAUTIONS 4
PRODUCT STRUCTION AND ACCESSORIES 6
CONTROL PANEL AND OPERATIONS 7
OPERATION GUIDELINES 9
MEMORY OPERATIONS 11
COMMON CLEANING METHODS 12
PRODUCT EXPLODED VIEW 14
CARE AND MAINTENANCE 16
OPTIONAL ACCESSORIES 17
SPECIFICATIONS 18
SD-485 US EN R1_StatClean user manual.indd 3 2016-06-09 12:58 PM
4
SAFETY PRECAUTIONS
Keep CLEANER away from children!
Please store the ultrasonic cleaner where it is not reachable by children. Danger to children! Danger of death through suffocation! Keep the packaging material from children. This appliance shall not be used by children. Keep the appliance and its cord out of reach of children.
To prevent life-threatening electrical shock, please observe the
following:
Danger of electrical shock! Do not use while bathing. Never immerse the device or the power cord in water or other liquid.
• Danger of electrical shock! Never touch the power plug with wet hands, especially inserting or removing the plug.
• Danger of electrical shock! If the unit has fallen into water during operation, do not touch the unit. Remove the power plug from the socket first.
• Danger of electrical shock! Do not spray water or liquid over the device.
• Never operate the device unattended.
• Follow the manual to operate the device.
• Do not use components unapproved by the manufacturer.
• When removing the power cord from the socket, grab the power plug not the cord.
• To protect the power cord from damage, do not cause it to get caught by things such as a cupboard door or a chair leg; do not drag across a hot surface.
• If there is damage to the power plug, cord, housing, or other parts of the device, do not use the device.
• Do not disassemble the device, except by professionals.
• If the unit is damaged, non-operational or has fallen into water, take it to an authorized dealer for service.
• Remove the power plug from the socket:
- if malfunction occurs before cleaning the device
- if the device is not going to be used for prolonged period after each use (recommended)
• The installation of an earth leakage circuit breaker with a rated tripping current of no more than 30 mA provides further protection against an electrical shock. The installation should only be carried out by a trained electrician.
To prevent fire hazards, please observe the following:
• Never block the vents on the device. Keep the vents free from lint, hair and other materials.
• Do not place the device on a soft surface, such as a bed or a couch, where the vents could be blocked.
• Observe the other warnings in the previous section.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
SD-485 US EN R1_StatClean user manual.indd 4 2016-06-09 12:58 PM
5
Use filtered water for best results.
Other observations:
• Do not operate the product without filling the tank with water. Running dry will damage the unit.
• Do not plug in the power cord before adding water to the tank. Do not fill the tank above the Max line to avoid overspill.
• Do not use solution containing abrasive substances or strong corrosive chemical solution not recommended by the manufacturer or the supplier.
• Place the device on a dry and flat surface for operation.
• When the device is subjected to severe electromagnetic interference, it may malfunction, stop operating or lose control functions. If this happens, unplug the power cord then reinsert it to restart the device.
IMPORTANT SAFETY INSTRUCTIONS:
When using electric appliances, basic precautions should always be followed, including the following:
• Read all the instructions before using the appliance.
• To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
• Only use attachments recommended or sold by the manufacturer.
• Do not use outdoors.
• To disconnect, turn all controls to the off (O) position, then remove plug from outlet. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. Unplug from outlet when not in use and before servicing or cleaning.
• To reduce the risk of electrical shock, do not put the appliance in water or other liquid. Do not place or store appliance where it can fall or be pulled into a tub or sink.
• All servicing of this product, including transducer replacement, is to be conducted by an authorized dealer.
• Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions or is dropped or damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.
SAFETY PRECAUTIONS
SD-485 US EN R1_StatClean user manual.indd 5 2016-06-09 12:58 PM
88:88
888
oCo
F
8:88
6
PRODUCT STRUCTURE & ACCESSORIES
A. Top Cover B. Stainless steel tank C. Housing D. Drainage pipe fitting E. Drainage valve handle
F. Control panel G. Handlesa H. Power switch I. Power socket J. Cover holder
1. Working Time Display
2. Multistage Thermeter
3. Set Termperature Display
4. ºC or ºF Indicator
5. Solution Usage
Remaining Time
6. Solution Warning Light
7. Degas Status
8. Normal Cleaning Status
9. Heater Status
10. Working Status
11. Heater Key
12. Funtion Key
13. On/Off Key
14. Decreasing Key
15. Solution Usage Timer
Set Key
16. Temperature Set Key
17. Timer Quick Set Key
Plastic basket
Power cord
Hose
Double beaker holder
OPTIONAL ACCESSORIES:
STANDARD ACCESSORIES:
A.
B.
C.
D.
E.
F.
G.
H. I.
J.
1
2
3
4
5
6
7 8
9
10
11
12
13
14
15
16
17
SD-485 US EN R1_StatClean user manual.indd 6 2016-06-09 12:58 PM
Loading...
+ 12 hidden pages