SCHURTER FAS Technical data

CONNECTORS
new snap-in mounting
POWER ENTRY MODULE WITH LINE FILTER
TYPE KFA
www.schurter.com
3
POWER ENTRY MODULES WITH LINE FILTER
without voltage selector without voltage selector with voltage selector
Actual information about approvals can be found on
http://www.schurter.com/approvals
C14
70° C
Plug removal necessary for fuse replacement
DDeessccrriippttiioonn
- Panel mount: Snap-in or screw-on mounting from front side
- 4 Functions: Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm 1- or 2­pole, with or without voltage selector (step switch), Line filter in stan­dard and medical version
- Quick connect terminals
- Alternative: version without line filter
CChhaarraacctteerriissttiiccss
- All single elements are already wired
- Plug removal necessary for fuse-link replacement The fuse drawer "Fingergrip" can be removed by hand For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front
- Qualified for use in equipment according IEC/EN 60950
OOtthheerr vveerrssiioonnss oonn rreeqquueesstt::
- medical version M80
TTeecchhnniiccaall ddaattaa
Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz Leakage current
standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz)
Dielectric strength
> 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE
Test voltage (2 sec) Allowable operation temp. -25 °C to 85 °C Climatic category 25/085/21, IEC 60068-1 Degree of protection from front side IP40 acc. to IEC 60529 Protection class Suitable for appliances with protection
class I acc. to IEC 61140 Terminals
Quick connect terminals 6.3 x 0.8 mm
With voltage selector: quick-connect
terminals 4.8 x 0.8 mm Panel thickness s
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm Materials: Housing Thermoplastic, black, UL 94V-0
Appliance-inlet /-outlet
C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 °C, 10 A, Protection class I
Fuseholder 1- or 2-pole, Shocksave category PC2
acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm. See page 7
Rated power acceptance @ Ta 23 °C
5 x 20: 2 W (1-pole)/ 1.6 W (2-pole) per
pole Power acceptance @ Ta > 23°C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves. Take note of the information on
page 5 Voltage selector optional, step, 3 digits Line filter Standard and medical version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
www.schurter.com
4
POWER ENTRY MODULES WITH LINE FILTER
DDiimmeennssiioonnss
Screw-on mounting
* with voltage selector
** without voltage selector
Snap-in mounting
29.35
33
R3
± 0.1
R4.1
(5)
(47)
(60)
(31.4)
33 max.
37 max.
(27.4)
37 max.
(28.8)
32.8
+ 0.15
0.00
+ 0.15
0.00
0.8 - 3
s
t
]
TTeecchhnniiccaall ddaattaa ooff ffiilltteerr--ccoommppoonneenntts
RRaatteedd ccuurrrreennt
[[AA]
10 Standard Version 2 x 0.3 68 2.2
10 Medical Version (M5) 2 x 0.3 68 1
Filter-Type Inductances
1 Standard Version 2 x 10 68 2.2
2 Standard Version 2 x 4 68 2.2
4 Standard Version 2 x 1.5 68 2.2
6 Standard Version 2 x 0.8 68 2.2
1 Medical Version (M5) 2 x 10 68 1
2 Medical Version (M5) 2 x 4 68 1
4 Medical Version (M5) 2 x 1.5 68 1
6 Medical Version (M5) 2 x 0.8 68 1
Capacitance
L [mH]
CX [nF]
Capacitance
CY [nF]
R [M]