otherwise without the prior written consent of Ingersoll Rand. Ingersoll Rand reserves the right to alter or revise the content of
this document as needed to support future product revisions, without obligation to notify any persons of specific changes.
The use of trademarks, trade names, or other product identification is solely for reference purposes. All other product brand
names are trademarks or registered trademarks of their respective holders.
Ingersoll Rand believes the information in this document to be accurate and reliable. Ingersoll Rand does not guarantee results
from the use of this information. Ingersoll Rand assumes no responsibility, obligation, or liability for the information presented in
this document.
Ingersoll Rand Security Technologies
245 W. Roosevelt Road, Bldg 7, Suite 48, West Chicago, IL 60185 / (800) 313-2962 / (630) 293-42 57 fax
P/N: M053-003-C www.ir-swa.com Page 2 of 20
Wireless Access
INSTALLATION INSTRUCTIONS
Wireless Reader Interface - Outdoor (WRI-OTD)
NOTE: These instructions are for installing the Wireless Reader Interface-Outdoor (WRI-OTD-12VDC), a
component of a Wireless Access System. AUWRI-OTD-12VDC is an Australian version of the outdoor wireless
reader interface.
In this manual, WRI-OTD refers to either a WRI-OTD-12VDC or an AUWRI-OTD-12VDC model.
After completing this installation refer to the “Configuring and Operating the Schlage Wireless Access System”
manual.
1. Schlage Wireless Access System Components...............................................................................................4
3. Installing the WRI-OTD .................................................................................................................................5
3.3Determining the Best WPIM and WRI-OTD Locations................................................................................6
3.4Mounting the WRI-OTD ...............................................................................................................................9
3.5Getting Wires In & Out of the WRI-OTD...................................................................................................10
3.6Wiring the WRI-OTD to its Access Control Peripherals.............................................................................10
245 W. Roosevelt Road, Bldg 7, Suite 48, West Chicago, IL 60185 / (800) 313-2962 / (630) 293-42 57 fax
P/N: M053-003-C www.ir-swa.com Page 3 of 20
Wireless Access
1. Schlage Wireless Access System Components
1.1Overview
Every access control system that uses Schlage Wireless Access contains two different types of modules
(Figure 1-1):
• at least one Wireless Panel Interface Module (WPIM), and
• at least one Wireless Access Point Module (WAPM)
Figure 1-1 – Wireless Access System Block Diagram
The Schlage Wireless Access product line contains several different expressions of each module.
The WPIM is wired to the access control panel and ideally is installed very close to the access control
panel. The WPIMs installation location is determined by the location of the WAPMs with which it will
communicate using RF.
The WAPM is installed at the access point where access will be controlled and/ or m onitored. De pe nding
on the application and which WAPM is used, some wiring at the access control point may be required.
Regardless of which WPIM or WAPM module is used, the communication link between the WPIM and
WAPM is always RF.
This manual describes the installation of a Wireless Reader Interface - Outdoor (WRI-OTD-12VDC or
AUWRI-OTD-12VDC) which is a WAPM.
• Drill & drill bits (the size will depend on the mounting fasteners used)
• Flat and Phillips head screwdrivers (1/8” wide flat blade for screw terminals)
Ingersoll Rand Security Technologies
245 W. Roosevelt Road, Bldg 7, Suite 48, West Chicago, IL 60185 / (800) 313-2962 / (630) 293-42 57 fax
P/N: M053-003-C www.ir-swa.com Page 5 of 20
Table 1-1- WRI-OTD Sales Model Table
Wireless Access
• Pencil (#2 lead)
• Mounting hardware (not provided), four ¼” diameter screws or bolts and/or anchors, type and length
of fasteners depend on the mounting surface.
2.2 Remote Antenna
If the WRI-OTD installation uses the Remote Antenna Module (RAM) option, please refer to the
“Remote Antenna Module Installation” manual before proceeding.
2.3 Determining the Best WPIM and WRI-OTD Locations
Proper selection of WPIM and WRI-OTD module mounting locations insures reliable RF
communications.
The WPIM manual contains a section for determining the best location for the WPIM.
The maximum distance between WPIM and a WRI-OTD is 200’ horizontally when installed inside a
building on the same floor that uses normal building construction materials. Never locate the WRI-OTD
or RAM & WPIM & RAM more than one (1) floor apart. If on different floors, limit the maximum
horizontal distance to 100’. Do not locate on different floors if the building’s floors use concrete over
metal construction. The maximum distance is up to 1000’ for a line of sight installation using the internal
antenna. If an external directional 6 db gain antenna (ANT-REM-I/O+6DB) is used on either the WRIOTD or WPIM and properly aimed, then the maximum line of sight distance can be increased to 2000’. If
external directional 6 db gain antennae (ANT-REM- I/O+6DB) are used on both the WRI-OTD and
WPIM and properly aimed, then the maximum line of sight distance can be increased up to 4000’.
This section provides additional application specific help and guidelines to select the best mounting
location for the WPIM and WRI-OTD modules.
NOTE: A WRI-OTD located with a substantial steel barrier intervening between it and the PIM
may require alternate WRI-OTD and/or PIM placement in order to ensure reliable RF
communications. In these applications, mount the PIM remote from the access control panel.
Choose the PIM location to prevent “shadowing” of the WRI-OTD from PIM radio transmissions.
RAMs may be used to get over, under, through, or around obstacles with a limit of 15-20 cable feet
distance between it’s WRI-OTD or WPIM and it’s RAM.
2.3.1 Outdoor Gate Applications
This section describes the ideal mounting locations for the WRI-OTD and WPIM to control an
outdoor gate (Figure 2-1).
The WRI-OTD has not been evaluated to UL325.