Schlage VIP 5500 Series,VIP 5594-FSA,VIP 5594-FSE,VIP 5596-FSE,VIP 5596-FSA Installation Manual

Form 57033 Rev. A
01-05-2004
VIP 5500 OPEN ARCHITECTURE MORTISE LOCK
INSTALLATION MANUAL
5500 MORTISE LOCK
AUTOBOLT
5500 MORTISE LOCK
STANDARD
The VIP 5500 series lock is a microprocessor controlled, electromechanical locking system. It is an open architecture product designed to interface with 3rd party panels encompassing all the features of the lock, reader, door status and egress (rex/request to exit) indication in one fire-rated piece of hardware. The 5100 employs a heavy-duty mechanical design tested and complying with ANSI/BHMA grade 1 standards for performance and reliability. It is pow­ered by 12 or 24 volts DC with only four wires required - two for power and two for commu­nications. The lock communicates with a PIB (panel interface board) which communicates with the panel as if it were separate components of an access control system.
Operationally, the outside lever is normally locked and the inside lever always retracts the bolt to allow egress. Electronic access control is achieved by entering an”Access Credential” (magnetic stripe card or Prox fob or card). The panel controls the lock through the PIB.
Please refer to all instruction manuals involved in the installation before you begin.
Functions
:
VIP 5594-FSA: (1” AutoBolt) - Fail Safe (unlocked) VIP 5594-FSE: (1” AutoBolt) - Fail Secure (locked) VIP 5596-FSA: (3/4” latch) - Fail Safe (unlocked) VIP 5596-FSE: (3/4” latch) - Fail Secure (locked)
Models
: MG: Magnetic stripe card reader PX: HID Prox card reader
S
tandard Monitoring Switches: DSM: Provides door status via data link to panel interface KSM: Provides mechanical key use events via data link to panel interface REX: Provides indication of inside lever use for request to exit input via data link
to panel interface
Options
: T3: Track 3 card reader (data must be ABA track 2 format) - MG only EXT: exterior use option - MG only (PX model has this standard) KD: Keyed Different, includes Schlage Everest cylinder KA: Keyed Alike, includes Schlage Everest cylinder LC: Less Cylinder
SLB: 2-3/4” backset, 1/2” latch bolt OLB: 2-3/8” backset, 1/2” latch bolt ELB: 2-3/4” backset, 3/4” latch bolt
BEFORE YOU BEGIN:
Standard units are shipped from the factory to fit 1-3/4” doors. Verify the door thickness. If the door is not 1-3/4” thick, verify that the door thickness option was ordered or consult factory.
PRE-INSTALLATION CHECK: AN OPEN ARCHITECTURE SYSTEM REQUIRES AT LEAST THREE COMPONENTS - A PANEL INTERFACE BOARD (PIB), AN ACCESS CONTROL PANEL (BY OTHERS) TO WHICH THE PIB IS CONNECTED AND THE VIP LOCK. SEE DOCUMENTATION FOR THE ACCESS CONTROL PANEL/SOFTWARE THIS LOCK WILL BE USED WITH FOR ANY PRE-INSTALLATION TESTING REQUIREMENTS AND REMEDIES. REFER TO THE WIRING INFORMATION INCLUDED WITH THE PIB FOR MORE INFORMATION.
PIB
PX MG
Door Thickness
Kits:
Available in 1/8” increments from 1-3/8” to 2-1/2”
This device complies with part 15 of the FCC rules. Operation is sub­ject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including any interference that may cause undesired opera­tion. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Form 57033 Rev. A
01-05-20042
VIP 5500 OPEN ARCHITECTURE MORTISE LOCK
INSTALLATION MANUAL
1. PREP DOOR AND FRAME (IF NOT ALREADY DONE):
A. Determine door hand. B. Mark the horizontal and vertical centerlines for the lock case (on door edge), strike, lever, and inside escutcheon. Note that the backset is actually 2.813” (or 2 13/16”). This is very important for proper mounting. C. Place template on inside of door (opposite the side that the keypad/reader will be on). Line up the correct reference lines on the template with the edge of the door, depending on the hand (see paper template). The centerline on the door should line up with the vertical centerline of the template. Use the paper template to mark all holes. (Though the paper template is the preferred way to prep the door, the dimensions below may be used if a paper template is not available.) D. Drill required holes. Note that all holes are required except the 3/4” hole just below the 1” hole, this is only required if the lock has the DSM (door status) switch.
FOR DOOR SWITCH WIRES:
3/4” HOLE 1” DEEP
DO NOT DRILL THRU
DOOR!
Form 57033 Rev. A
01-05-20043
VIP 5500 OPEN ARCHITECTURE MORTISE LOCK
INSTALLATION MANUAL
Suggested wire raceway: 1/2” hole into top of mortise pocket.
Wiring will exit toward inside through this hole.
FSE & FSA HARD WIRED MODELS REQUIRE WIRING TO BE RUN TO THE MORTISE POCKET FROM THE HINGE SIDE. BELOW IS A SUGGESTED WAY TO DO THIS. A DOOR CORD OR ELECTRIC HINGE OR TRANSFER DEVICE MUST BE USED TO GET WIRING FROM THE FRAME TO THE DOOR. NOTE THAT WHEN USING AN ELECTRIC HINGE IT IS RECOMMENDED THAT THE POWER WIRES BE DOUBLED OR TRIPLED UP (ON BOTH THE POSITIVE AND GROUND LEGS) TO AVOID SIGNIFICANT VOLTAGE DROP THROUGH THE THIN WIRES IN THE HINGE.