4341 EXIT BUTTON
INSTALLATION & OPERATING
INSTRUCTIONS
FOR ASSISTANCE, CALL SARGENT AT 1-800-810-WIRE (9473)
1
1. DESCRIPTION
The model 4341 is a surface mount momentary rectangular exit button without indicators which is often used as a receptionist’s
button mounted on the underside of a desk.
The NO and NC (DPST) contact switch when the button is depressed and return when it is released. The switch is UL listed with
3 AMP capacity. Note that the switch type is double pole double throw. Two of the contacts are not factory wired (See drawing on
the second page) since all six contacts are rarely required. This also provides less factory wiring and a less crowded hookup. The
installer may use these contacts by soldering on leads.
The 4341 can be used for momentary release of fail safe or fail secure electric locks. If interfaced with a timer, such as the
SARGENT TMR2 or TMR9, it can provide for timed release of electric locks. It may also be used to input an REX (request to exit)
signal to a card reader system. We recommend that the local building or fire safety authority be consulted prior to using exit
buttons for door egress. They may require a "no special knowledge" exit device such as SARGENT 80 Series exit device with a
REX switch (55-).
2. INSTALLATION
The 4341 comes with color coded hookup wires installed. The drawing on the second page shows identification of the unit's
connection points.
**Securitron is an ASSA ABLOY Group Co.
Copyright ©SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing is prohibited.
A7865B

2
3. WIRING
The 4341 can be used in many different applications but the drawings below show two
common ones: momentary release of a fail safe or fail secure electric lock and timed
release of a fail safe electric lock using the 4341 and the SARGENT TMR Time Delay.
Momentarily pressing the button will release the lock for the amount of time set on the
TMR. The wiring is also done in double break fashion so that even if the timer fails, the
button will be able to momentarily release the lock for added safety.
Wire Identification
Blue (NO 2)
NO 2
NO 1
Red (NC 1)
Red / White (COM 1)
Blue / White (COM 2)
Red
Blue
Blue/White
Power
Supply
+
-
Red/White
Timed double break release of fail safe lock
If fail safe
4341
4341
If fail secure
+
+
-
-
+
Blue Yellow
Blue/White
Power
Supply
+
-
Red/White
Green
Red
Black
Red White
TMR9
Electric
D.C Lock
Fail Safe
D.C Lock
Momentary release of fail safe or fail secure electric lock
Note: NO 1 and NC 2 are not
factory wired but may be wired
by the installer if desired
Rear of unit shown
Copyright ©SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing is prohibited.
A7865B