Sanyo VCC-9800P Instruction Manual

INSTALLATION MANUAL
Color CCD Camera
Install these units securely according to this installation manual. Be aware that allowing them to fall may cause personal injury.
This installation should be made by a qualified service person and should conform to all local codes.
Please read this manual before installing and using this unit, and always follow the instructions in it for proper use. Please also read the separate Instruction Manual before using the unit for proper use.
Contents
Product Lineup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Surface Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
In-ceiling Mount (Closed Type) . . . . . . . . . . . . . . . . . . 3
In-ceiling Mount (Open Type) . . . . . . . . . . . . . . . . . . . . 4
Connections and Settings . . . . . . . . . . . . . . . . . . . . . . 5
Address Settings Table. . . . . . . . . . . . . . . . . . . . . . . . . 7
Pattern Sheet (inserted at the end of this manual)
Important
• Be careful when opening holes for installing the unit. Work with the power and video cables pulled out for easy installation.
• Make sure to properly perform waterproofing for the ceiling where you are installing the unit.
• Make sure that the surface in the installation location has no unevenness and is strong enough to bear the total weight of the unit.
• Install this unit in an environment where the temperature range stays between -10°C/+14°F and +50°C/+122°F (no condensation allowed).
English
Remove the plastic cover (A) and then the tape (B) fixing the lens.
Put back the plastic cover (A), and turn it clockwise until you hear it click to securely lock it.
CAUTION: For VA-80S (Power Borard Unit)
ALL-POLE MAINS SWITCH with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building.
(A)
(B)
Product Lineup
To install the camera unit, the optional housing is required. When using a housing, be sure to choose the correct one for your environment of use.
Indoor Type Outdoor Type
(In-ceiling Mount)
+
P3 P4 P2
(Surface Mount)
In-ceiling
Bracket
Closed Type
VA-80ME
Power Board
Unit
(VA-84S;
for AC24V)
(VA-80S;
for AC230V)
In-ceiling
Bracket
Open Type
VA-80MF
Power Board
Unit
(VA-84S;
for AC24V)
(VA-80S;
for AC230V)
Refer to the instruction
manual supplied with each product.
Pendant Mounting Bracket (VA-80BP)
Attachment (VA-80A)
Power Board Unit
(VA-84S; for AC24V)
(VA-80S; for AC230V)
Refer to the instruction manual supplied
with each product.
Wall Mounting
Bracket (VA-80BW)
Outdoor Housing (VA-80EX)
Pole Mounting
Adapter (VA-80AP)
Corner Mounting
Adapter (VA-80AC)
Power Board Unit
(VA-84S; for AC24V)
(VA-80S; for AC230V)
Surface Cover
VA-80F
– 1 –
Clear Dome Cover (VA-CM8C)
Smoked Dome Cover (VA-CM8S)
Surface Mount
Make sure to also consult the Surface Cover Instruction Manual.
VA-80F
1. Installing the power board unit
1 Place the pattern sheet at the end of this manual on
the ceiling, mark the locations and drill the holes for the cables and screws.
Pull out the cables from the ceiling.
2 Attach the supplied dust sheet (A) to the base of the
power board unit and the detachable piece of the sheet (B) to the side.
Peel off the release-coated paper from the dust sheet before attaching.
3 Pass the cables through the slit (C) in the dust
sheet.
4 Fix the power board unit to the ceiling using the
supplied screws (D) (4 places).
5 Connect the cables and set the switches.
See “Connections and Settings” on page 5.
2. Mounting the camera unit
6 Fasten the camera unit safety wire (F) to the hook
(G) on the inner side of the power board unit.
7 Align the arrows (H) of the same color (blue) on the
camera unit and the power board unit, and push the camera unit until they click.
8 Align the arrows (H) of the same color (blue) on the
inner side of the surface cover and the power board unit, and fix the cover by rotating it clockwise.
21
AA
BB
BB
Surface routing (ceiling)
Pass the cables through the cable hole (E) at the side of the power board unit, and attach the dust sheet (A) as shown in the figure.
E
AA
F
3
C
5
4
D
D
G
6
H; Blue 7
How to attach the drop-prevention cable (accessory)
1) Peel off the two-sided tape (K) at the end of the cable
and attach it to the hook (L) on the inner side of the surface cover as shown in the figure.
2) Fasten the cable to the hook (M) on the side of the
power board unit.
M
K
L
Protrusion
To remove the camera unit
H; Blue 8
Removed in case of surface routing.
Accessories
– 2 –
Dust sheet Drop-prevention
cable
Screw (for power board unit)
In-ceiling Mount (Closed Type)
1
Make sure to also consult the In-ceiling Bracket Closed Type Instruction Manual.
VA-80ME
1. Installing the power board unit
1 Draw a circumference on the ceiling using the
supplied drop-prevention cable (A) as compass, and drill a hole for installing the in-ceiling bracket.
Pull out the cables from the ceiling.
2 Pass the supplied screws a and washer b through
each of the power board unit screw holes (B) and fasten them loosely using washers (4 places).
3 Align the arrows (C) of the same color (blue) on the
power board unit and the in-ceiling bracket, and mount the power board unit. Tighten firmly the screws (B) loosely fastened in the previous step.
Pass the video cable (D) through the bracket cable
hole as preparation for the next step.
2. Installing on the ceiling
4 Attach the supplied safety wire (E) to the ceiling
beam, for example, then connect it to the bracket-top hook (F).
5 Connect the video cable and pass the connection
cables through the bracket.
6 Insert the bracket into the ceiling hole and fix it
using screws (G) (2 places).
7 Connect the cables and set the switches.
See “Connections and Settings” on page 5.
8 Align the arrows (C) of the same color (blue) on the
camera unit and the inner side of the bracket, and push the camera unit until they click.
9 Align the SANYO logos on the supplied bracket
cover and the bracket, and push the cover until they click.
φ192 mm/7.6”
6
G
A
5
3 C; Blue
4
B
2
B
B
E
F
F
GG
B
a
b
D
E
4
6
7
G
How to attach the drop-prevention cable (accessory)
Fasten the drop-prevention cable (A) to the hooks (H) on the bracket and its cover, then slide the cable as shown in the figure.
H
A
H
To remove the camera unit
(for power board unit)
Drop-prevention
cable
Accessories
9
C; Blue
8
Bracket coverSafety wireScrew a, washer b
– 3 –
In-ceiling Mount (Open Type)
1
Make sure to also consult the In-ceiling Bracket Open Type Instruction Manual.
1. Installing the power board unit
1 Drill a hole (φ196 mm/7.7”) in the ceiling for
installing the in-ceiling bracket.
Pull out the cables from the ceiling.
2 Pass the supplied screws a and washer b through
each of the power board unit screw holes (A) and fasten them loosely using washers (4 places).
3 Align the blue sticker (B) on the bracket and the
arrow (B) of the same color on the power board unit, and then mount the power board unit in the bracket.
When inserting the power board unit, do it diagonally.
4 Mount the power board unit in the in-ceiling bracket.
Tighten firmly the screws (A) loosely fastened in the previous step.
2. Installing on the ceiling
5 Attach the supplied safety wire (C) to the ceiling
beam, for example, then connect it to the bracket-top hole (D).
6 Pass the connection cables through the slit in the
dust sheet (E), and connect the video cable.
7 Insert the bracket into the ceiling hole and fix it
using screws (F) (2 places).
8 Connect the cables and set the switches.
See “Connections and Settings” on page 5.
9 Align the blue sticker (B) on the bracket and the
arrow (B) of the same color on the camera unit, and then push the camera unit until they click.
ÀAlign the SANYO logos on the supplied bracket
cover and the bracket, and push the cover until they click.
7
φ196 mm/7.7”
6
E
3 B; Blue
7
5
VA-80MF
2
a
b
A
A
A
A
C
D
C
5
D
F
8
F
7
F
How to attach the drop-prevention cable (accessory)
Fasten the drop-prevention cable (G) to the hooks (H) on the bracket and its cover, then slide the cable as shown in the figure.
H
G
H
To remove the camera unit
Dust sheet
Accessories
Screw a, washer b
(for power board unit)
B; Blue 9
Drop-prevention cable
– 4 –
Bracket coverSafety wire
Connections and Settings
Make sure to also consult the Power Board Unit Instruction Manual.
Do not connect the power cord until all other connections have been completed.
Power Supply Connection
For the connections use cables higher than
LNG
18 AWG.
When using AC 24 V, follow the connection steps in
the leaflet titled “Connecting the power cable” that comes with the power board unit (VA-84S).
<Live>
<Neutral> <Ground>
• Fix the power cable end firmly so that the power terminal connection does not come loose. Use solderless terminals (ring or spade type) for wiring.
• After connection, always install the supplied power terminal cover A for safety reasons.
Joint board
AC 230 V
A
BNC type
Monitor Connection
Supported coaxial cables
Cable type Length
RG-59U (3C-2V) 250 m (273.4 yd) max.
RG-6U (5C-2V) 500 m (546.8 yd) max.
RG-11U (7C-2V) 600 m (656.2 yd) max.
• Using different cables from those specified here may attenuate the video and/or sync signals and interfere with correct transmission.
• RG-59U coaxial cables can be used when distance between devices is short, but not in duct or aerial routing.
SIDE-A
O
R
B
K
R
D
G
R
B
L
1 Controller connection
WH
L
Y
L
L
S
L
B
R
Connections
White Yellow
485A 485B
2 Alarm signal input
IN 1 - 8
To C OM
Alarm input signal
3 Alarm signal output
If a lamp is connected to this cable, it will light up when an alarm signal is received or when the built-in motion sensor detects movement.
OUT 1/2
To C OM
All connection cables should be 24 AWG or higher with a
maximum length of no more than 600 m (656.2 yd).
For details on 2 and 3, refer to the “Alarm Settings (ALARM)” in
the Instruction Manual.
Alarm output signal
2
1
SIDE-B
Switch Settings
1 System control setting switches
• Switch 6 is unused.
• The factory setting is represented in bold.
1 Baud rate
Set the same baud rate as that on the camera.
Switch 1 2
2400 OFF OFF 4800 ON OFF 9600 OFF ON
19200 ON ON
2 Control method
Set either to RS485 or coaxial (COAX).
Switch 3
Coaxial (COAX) ON
RS485 OFF
3 Protocol
Set the protocol for controlling the camera.
Switch 4
SSP (SANYO) OFF
PELCO ON
4 Termination (Switch 5)
“OFF” is set by default. When connecting multiple cameras, termination setting must be “ON” on the last camera while it must be “OFF” on all others.
ON
123456
1234
CAMERA LENS PAN/TILT AUTO MODE ALARM PRIVACY MASK PASSWORD LANGUAGE OPTION
PRESET MENU
SET SET SET SET SET SET SET SET SET
OFF BACK
ALARM
ALARM IN
y
ALARM OUT ALARM DISABLE
MOTION ALARM DISPLAY
PRESET MENU
1 1 OFF
OFF OFF
OFF BACK
y
2 Address setting switches
Set the camera address. See “Address Settings Table” on page 7.
ON
12345678
– 5 –
Connections and Settings
To prevent electromagnetic interference
Be sure to attach the clamping cores supplied with the camera unit to the cables as illustrated.
Power cable
Control and alarm input/output cables
Video cable
Connections for using coaxial control (System connection)
(1 - 16)
MONITOR OUT
MAIN
Video input
MON2
terminal
CameraCamera
A RS-485 B
DO NOT CONNECT TO PHONE LINE
Terminator
switch
Communication conversion connectors
Monitor
(sold separately)
Video input terminal
Digital video recorder (sold separately)
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
IN
OUT
Video input terminal
System controller
(sold separately)
– 6 –
TELEMETRY
VIDEOAB
Address Settings Table
Addresses are specified by setting the switches to ON/OFF. In the table, the circle mark “m” means ON. Set switches as shown in the table.
SANYO protocol: 1 - 127 PELCO protocol: 1 - 255
ON
ONOFF
ON
ONOFF
Switch 8
• Address 1 - 127: OFF
12345678
• Switch 8 is unused.
Address
(Camera No.)
Protocol
SANYO/PELCO
0* 128
1 129 2 130 3 131 4 132 5 133 6 134 7 135 8 136
9 137 10 138 11 139 12 140 13 141 14 142 15 143 16 144 17 145 18 146 19 147 20 148 21 149 22 150 23 151 24 152 25 153 26 154 27 155 28 156 29 157 30 158 31 159 32 160 33 161 34 162 35 163 36 164 37 165 38 166 39 167 40 168 41 169 42 170
PELCO 1 2 3 4 5 6 7
Switch No.
m
m
m m
m
m m
mm
m m m
m
m m
mm
m m m
mm
m m m
mmm
m m m m
m
m m
mm
m m m
mm
m m m
mm m
m m m m
mm
m m m
mmm
m m m m
mmm
m m m m
mmmm
m m m m m
m
m m
mm
m m m
mm
m m m
mm m
m m m m
mm
m m m
mmm
* When setting the address by using the menu screen on the camera, set the address setting switches to “0”.
12345678
Address
(Camera No.)
Protocol
SANYO/PELCO
43 171 44 172 45 173 46 174 47 175 48 176 49 177 50 178 51 179 52 180 53 181 54 182 55 183 56 184 57 185 58 186 59 187 60 188 61 189 62 190 63 191 64 192 65 193 66 194 67 195 68 196 69 197 70 198 71 199 72 200 73 201 74 202 75 203 76 204 77 205 78 206 79 207 80 208 81 209 82 210 83 211 84 212 85 213
PELCO 1 2 3 4 5 6 7
• Address 128 - 255: ON
Switch No.
m m m m
mm m
m m m m
mmm m
m m m m m
mm
m m m
mmm
m m m m
mmm
m m m m
mm mm
m m m m m
mmm
m m m m
mmmm
m m m m m
mmmm
m m m m m
mmmmm
m m m m m m
m
m m
mm
m m m
mm
m m m
mm m
m m m m
mm
m m m
mm m
m m m m
mm m
m m m m
mmm m
m m m m m
mm
m m m
mmm
m m m m
mmm
m m m m
Address
(Camera No.)
Protocol
SANYO/PELCO
86 214 87 215 88 216 89 217 90 218 91 219 92 220 93 221 94 222 95 223 96 224 97 225 98 226
99 227 100 228 101 229 102 230 103 231 104 232 105 233 106 234 107 235 108 236 109 237 110 238 111 239 112 240 113 241 114 242 115 243 116 244 117 245 118 246 119 247 120 248 121 249 122 250 123 251 124 252 125 253 126 254 127 255
PELCO 1 2 3 4 5 6 7
Switch No.
mmmm
m m m m m
mm m
m m m m
mmmm
m m m m m
mmm m
m m m m m
mmmm m
m m m m m m
mm
m m m
mmm
m m m m
mmm
m m m m
mm mm
m m m m m
mmm
m m m m
mmmm
m m m m m
mm mm
m m m m m
mmm mm
m m m m m m
mmm
m m m m
mmmm
m m m m m
mmmm
m m m m m
mm mmm
m m m m m m
mmmm
m m m m m
mmmmm
m m m m m m
mmmmm
m m m m m m
mmmmmm
m m m m m m m
– 7 –
Pattern Sheet
4- φ4.5 (0.2) P. D φ168 (6.6)
166 (6.5)
186 (7.3)
Scale: 1/1
Unit: mm (inch)
MEMO
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
...............................................................................................
b Dimensions
71 (2.8)
156 (6.1)
φ136 (5.4)
Unit: mm (inch)
Printed on recycled paper Imprimé sur du papier recyclé Impreso en papel reciclado Gedruckt auf Recyclingpapier
使用再生纸印刷
1AC6P1P3149-A L5BU2/XE (0807KP-HS)
SANYO Electric Co., Ltd.
Printed in China
Loading...