Français EspañolEnglish
INSTRUCTION MANUAL
VCC-9684VA
Color CCD Camera
About this manual
Before installing and using the camera, please read this manual carefully.
Be sure to keep it handy for later reference.
Ceiling Installed Wall Installed
In-ceiling routingSurface routing*1
*1 Surface routing
Cutout
Rib mark
Safety Guard
THIS SYMBOL INDICATES THAT THERE ARE IMPORTANT
OPERATING AND MAINTENANCE INSTRUCTIONS IN THE
LITERATURE ACCOMPANYING THIS UNIT.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
For the customers in Canada
This Class B digital apparatus complies with Canadian ICES-003.
Pour la clientèle canadienne
Cet appareil numerique de la Classe B est conforme à la norme
NMB-003 du Canada.
This installation should be made by a qualified service person and should
conform to all local codes.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following
measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved by Sanyo may void the user's
authority to operate this camera.
1AC6P1P3265-L5CJ2/US (1107KP-HS)
SANYO Electric Co., Ltd.
Printed in China
PRECAUTIONS
Important
• Be careful when opening holes for installing the unit. Work with the
power and video cables pulled out for easy installation.
• Make sure to properly perform waterproofing for the ceiling or wall
where you are installing the unit.
• Make sure that the surface in the installation location has no
unevenness and is strong enough to bear the total weight of the unit.
• Install this unit in an environment where the temperature range stays
between -10°C and +50°C/14°F and 122°F (no condensation allowed).
• As a precaution against static electricity damage, touch a nearby metal
object (door knob, etc.) to dissipate static electricity in your body before
touching this unit.
■ In case of a problem
Do not use the unit if smoke or a strange odor comes from the unit,
or if it seems not to function correctly. Turn off the power
immediately and disconnect the power cord, and then consult your
dealer or an Authorized Sanyo Service Center.
■ Do not open or modify
Do not open the cabinet, as it may be dangerous and cause damage
to the unit. For repairs, consult your dealer or an Authorized Sanyo
Service Center.
■ Do not put objects inside the unit
Make sure that no metal objects or flammable substance get inside
the unit. If used with a foreign object inside, it could cause a fire, a
short-circuit or damage. Be careful to protect the unit from rain, sea
water, etc. If water or liquid gets inside the unit, turn off the power
immediately and disconnect the power cord, and then consult your
dealer or an Authorized Sanyo Service Center.
■ Be careful when handling the unit
To prevent damage, do not drop the unit or subject it to strong shock
or vibration.
■ Do not install this unit close to magnetic fields
The magnetic fields may result in unstable operation.
■ Protect from humidity and dust
To prevent damage, do not install the unit where there is greasy
smoke or steam, where the humidity may get too high, or where
there is a lot of dust.
■ Protect from high temperatures
Do not install close to stoves, or other heat sources, such as
spotlights, etc., or where it could be subject to direct sunlight, as this
could cause deformation, discoloration or other damages.
Be careful when installing close to the ceiling, in a kitchen or boiler
room, as the temperature may rise to high levels.
■ Cleaning
• Dirt can be removed from the cabinet by wiping it with a soft cloth.
To remove stains, wipe with a soft cloth moistened with a soft
detergent solution and wrung dry, then dry by wiping with a soft
cloth.
• Do not use benzine, thinner or other chemical products on the
cabinet, as this may cause deformation and paint peeling. Before
using a chemical cloth, make sure to read all accompanying
instructions. Make sure that no plastic or rubber material comes
into contact with the cabinet for a long period of time, as this may
cause damage or paint peeling.
SPECIFICATIONS
Scanning system : NTSC standard 525 lines, 60 fields/sec.
Image sensor : 1/4" interline transfer method CCD
Number of effective pixels : 768 (H) x 494 (V)
Horizontal resolution : 540 TV lines, typical
Minimum illumination
(approx.) : 0.5 lx (F0.95)
Video output : 1.0 V(p-p)/75 Ω, composite, BNC
Video S/N ratio : More than 48 dB (AGC off: More than 50 dB)
Vari-focal lens : f=2.8 - 8 mm, F0.95 - 1.7
Rotation range : (On the ceiling) Pan: ± 100 degrees
Backlight compensation : OFF, Multi-spot metering (High/Normal), Center zone
White balance : ATW/Manual
Electronic shutter : 1/60, 1/100, 1/1000, 1/2000 sec.
Aperture compensation : Sharp/Normal
Sync system : Internal sync/Line-lock
Operating Environment : Temperature: –10°C – +50°C (14°F – 122°F)
Power supply : 24 V AC ±10%, 60 Hz / 12 - 15 V DC
Power consumption
(approx.) : 2.4 W
Weight (approx.) : 500 g (16 oz.)
Accessory : Screw ×1, Warranty ×1
Appearance and specifications are subject to change without prior notice
or obligations.
UTP support (VA-10T: option board)
(On the wall) Pan: ± 90 degrees
metering
Humidity: less than 90 % RH (no condensation)
Tilt: 0 - 90 degrees
Tilt: 0 - 90 degrees
SERVICE
The camera is a precision instrument. Handle it carefully and always
follow the safety precautions. If the camera requires service, never
try to repair it yourself or open the casing.
For servicing, maintenance, or repairs, consult your dealer or an
Authorized Sanyo Service Center.
■ Dimensions
φ
151 (6.0)
φ
100 (4.0)
Unit: mm (inch)
INSTALLING BASE PLATE AND CONNECTIONS
Open the base plate.
Push
Point the arrow (↓) in the same
direction as the lens
orientation.
(A)
• Length: 35 mm/1.4 in. or more
• Diameter: 3.5 to 5.0 mm/0.1 to 0.2 in.
• Height of screw head:
5 mm/0.2 in. or less (washer included)
Make sure to tighten the screws properly.
Using screws of sizes other than specified may cause the unit to fall.
Place the base plate so that
the arrow points downward.
(A)
(A)
Ceiling Installed
(A)
(A)
Wall Installed
(A)
(A)
(A)
(A)
1
2
1
2
1
2
Monitor Connection
Cable type Length
RG-59U (3C-2V) 250 m (273 yds) max.
RG-6U (5C-2V) 500 m (547 yds) max.
RG-11U (7C-2V) 600 m (656 yds) max.
• When using an RG-59U (3C-2V) cable, do not let it
dangle in the air or attach it to piping.
• If you use a cable other than the types above, the
image or sync signal will be attenuated and will not
be transmitted correctly.
Power Supply Connection
b With AC 24 V b With DC 12 V
Check that +/- polarity is
correct.
(RED)
(BLACK)
(WHITE)
For the connections, use cables thicker than 18 AWG.
~
~
GND
(RED)
(BLACK)
& Reverse side
104 (4.2)
+
–
INSTALLATION ADJUSTING CAMERA IMAGE
FrançaisEspañol English
1 Remove the dome cover.
Push
2 Remove the blue tape, air cushion and screw.
1 Blue tape
Installing on the Ceiling
1 Connect the cables from the ceiling.
2 Mount the camera unit to the base plate.
2
1
Push the camera unit
until it clicks taking care
not to pinch the cable.
Supplied
screw
Make sure that the camera unit and base plate fit
perfectly.
Preparation
Do not touch the lens and lens barrel.
3 Turn the lens
90 degrees
clockwise.
2 Air
BA
Installing on the Wall
1 Set the lens in the correct direction.
1 Remove the black screw A.
2 Turn the lens in the arrow direction to reverse the
orientation.
3 Confirm that the dials are located at the top.
4 Temporarily tighten the removed black screw A.
2
Power
cables
14
A Black screw
2 Connect the cables from the wall.
3 Mount the camera unit to the base plate.
2
3
Make sure that the camera unit and base plate fit
perfectly.
4 Screw
cushion
Supplied
screw
5 Loosen the
black
screw.
3
Push the camera unit
until it clicks taking care
not to pinch the cable.
b Checks on monitor
Connect a portable monitor.
MONITOR
OUT
GND
A dedicated MONITOR OUT connector is provided for
portable monitor.
b Angle-of-view adjustment
Adjust the angle of view by moving the lens unit.
200
(Ceiling Installed) (Wall Installed)
● Do not touch the lens and lens barrel.
● When rotating the lens unit, make sure a metal
edge does not damage the cables.
b Zoom and focus
B
A
C
1 Zoom
Loosen the zoom ring
knob
A, and turn the
zoom ring
or out.
When monitoring lighting or other extremely bright objects (which
exceed the maximum required illumination), smearing may occur in
the vertical or horizontal direction (either above and below the
high-brightness object or as a perpendicular band). In such a case,
adjust the angle of illumination and other factors while observing the
monitor.
B to zoom in
When finished, tighten the zoom and focus ring
AC securely.
knobs
2 Focus
Loosen the focus ring
knob
C, and turn the
focus ring
the object.
D to focus on
Camera adjustments/settings
The camera comes pre-adjusted and ready to install at the
time of factory shipment, but you can make adjustments or
settings if you need.
If you have trouble adjusting the camera, consult your dealer
or an Authorized Sanyo Service Center.
● Electronic shutter speed setting
(unit: second)
1/60 1/100 1/1000 1/2000
1
1
2
Switch1: MSB Switch2: LSB
• Using the high speed electronic shutter indoors
with low lighting, will give darker pictures. In
such a case, add some lights to make sure the
lighting is sufficient.
• If the lighting is very bright, pay attention to the
light angle in order to avoid or minimize the
smear phenomenon effect.
2
21
21
● Aperture compensation
Sharp outline Normal outline
3
3
● Backlight compensation
Only when using an auto-iris lens
Multi-spot metering
Backlight compensation
to the entire screen*
Center zone metering
Backlight compensation
to the central portion of
the screen
OFF
* If the background of the object is extremely dark, set to
Center zone metering.
High Normal
54
54
54
● White balance (color compensation)
Manual White Balance
MWB
6
Turn clockwise to
augment the color.
RED
BLUE
● Sync setting
Line-Lock
Synchronizes the unit with
power frequency*
LL
7
PHASE
* Adjust the roll by turning the LINE PHASE dial on the
second and subsequent cameras.
If the vertical roll cannot be corrected by adjusting
the LINE PHASE dial on the second and
subsequent cameras, tr y adjusting the LINE
PHASE dial on the first camera. If it still cannot be
corrected, please check that the polarity of the
power cords of all connected devices is correct.
● Lens iris level adjustment
If the entire image is too dark or too bright, adjust
the condition.
54
A. I. LENS
Low (darker) High (brighter)
After finishing camera adjustments/settings ...
1 Tighten the screw.
For wall installation, securely tighten the
screw you temporarily tightened.
2 Install the dome cover.
1 Push the dome cover until it clicks.
1
2 While holding down the dome cover, turn it
in the direction of the arrow until the lens is
completely visible through the camera
window.
Auto-Tracing
White balance
(ATW)
6
Internal sync
7
LEVEL
1