Ordering number: EN 1650B
±
θ
°
°
°
−
°
±
8
Thick Film Hybrid IC
STK4151 V
AF Power Amplifier (Split Power Supply)
(30W + 30W min, THD = 0.08%)
Features
• Built-in muting circuit to cut off various kinds of pop
noise.
• Greatly reduced heat sink due to substrate temperature
Package Dimensions
unit: mm
4040
[STK4151 V ]
125 ° C guaranteed.
• Distortion 0.08% due to current mirror circuit.
• Pin-compatible with the STK4101II series. The
STK4101V series use the same package and are available for output 6W to 50W.
• Excellent cost performance.
Specifications
Maximum Ratings
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage V
Thermal resistance
Junction temperature Tjmax 150
Operating substrate temperature Tc 125
Storage temperature Tstg
Available time for load short-circuit t
at Ta = 25 ° C
max
CC
j-c 2.1
30 to +125
V
= ± 28V, R
s
CC
Po = 30W
= 8 Ω , f = 50Hz,
L
42.0 V
C/W
C
C
C
2s
Recommended Operating Conditions
Parameter Symbol Conditions Ratings Unit
Recommended supply voltage V
Load resistance R
CC
L
SANYO Electric Co., Ltd. Semiconductor Business Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
at Ta = 25 ° C
28.0 V
Ω
61197HA (ID) / 8298MO / 4015MY, TS No. 1650—1/5
−
− 2 − 5 −
STK4151 V
Operating Characteristics
at Ta = 25 ° C, V
= ± 28.0V, R
CC
= 8 Ω (non-inductive), Rg = 600 Ω , VG = 40dB
L
unless otherwise specified, at specified test circuit (based on sample application
circuit)
Parameter Symbol Conditions min typ max Unit
Quiescent current I
Output power
P
P
CCO
(1)
O
(2)
O
V
= ± 33.5V 20 40 100 mA
CC
f = 20Hz to 20kHz,
THD = 0.08%
V
= ± 25V, f = 1kHz,
CC
THD = 0.2%, R
= 4 Ω
L
30 W
35 W
Total harmonic distortion THD f = 1kHz, Po = 1W 0.08 %
Frequency response f
Input impedance r
Output noise voltage V
Neutral voltage V
Muting voltage V
, f
L
H
i
NO
N
M
+0
Po = 1W, dB 20 to 50k Hz
−
3
f = 1kHz, Po = 1W 55 k Ω
V
= ± 33.5V, Rg = 10k Ω
CC
V
= ± 33.5V
CC
70 0 +70 mV
1.2 mVrms
10 V
Note : For power supply at the time of test, use a constant-voltage power supply
unless otherwise specified.
* For measurement of the available time for load short-circuit and output
noise voltage, use the specified transformer power supply shown right.
** The output noise voltage is represented by the peak value on rms scale
(VTVM) of average value indicating type. For AC power supply, use an AC
stabilized power supply (50Hz) to eliminate the effect of flicker noise in AC
primary line.
Specified transformer power supply
(Equivalent to RP-25)
Equivalent Circuit
No. 1650—2/5