SANYO STK4102II Datasheet

Ordering number: 2324B
±
θ
°
°
°
°
±
8
Thick Film Hybrid IC
STK4102 II
AF Power Amplifier (Split Power Supply)
(6W + 6W min, THD = 0.4%)

Features

• The STK4102II series (STK4102II) and STK4101V series (high-grade type) are pin-compatible in the out­put range of 6W to 50W. Once the PCB pattern is designed, you can easily satisfy the requirements for

Package Dimensions

unit: mm
4083
[STK4102 II ]
new sets simply be changing the IC.
• Small-sized package whose pin assignment is the same as that of the STK4101II series
• Built-in muting circuit to cut off various kinds of pop noise
• Greatly reduced heat sink due to substrate temperature 125 ° C guaranteed
• Excellent cost performance
Specifications
Maximum Ratings
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage V Thermal resistance Junction Temperature Tj 150 Operating substrate temperature Tc 125 Storage temperature Tstg Available time for load short-circuit ts V
at Ta = 25 ° C
max
CC
j-c 5
30 to +125
= ± 13.2V, R
CC
= 8 Ω , f = 50Hz, Po = 6W 2 s
L
20.5 V C/W
C C C
Recommended Operating Conditions
Parameter Symbol Conditions Ratings Unit
Recommended supply voltage V Load resistance R
CC
L
SANYO Electric Co., Ltd. Semiconductor Business Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
at Ta = 25 ° C
13.2 V
70397HA (ID) / O138YT / 8038TA, TS No. 2324—1/8
STK4102 II
Operating Characteristics
Parameter Symbol Conditions min typ max Unit
Quiescent current Icco V
Output power
Total harmonic distortion THD Po = 1.0W, f = 1kHz 0.3 % Frequency response f Input impedance r
Output noise voltage V Neutral voltage V Muting voltage V
Notes. For power supply at the time of test, use a constant-voltage power
supply unless otherwise specified. For measurement of the available time for load short-circuit and out­put noise voltage, use the specified transformer power supply shown right. The output noise voltage is represented by the peak value on rms scale (VTVM) of average value indicating type. For AC power supply, use an AC stabilized power supply (50Hz) to eliminate the effect of flicker noise in AC primary line.
at Ta = 25 ° C, V
R
: non-inductive load
L
Po (1)
Po (2)
, f
L
H
i
NO
N
M
= ± 13.2V, R
CC
= ± 17V 20 40 100 mA
CC
THD = 0.4%, f = 20Hz to 20kHz
= ± 12V, THD = 1.0%,
V
CC
R
= 4 Ω , f = 1kHz
L
Po = 1.0W, dB 20 to 50k Hz Po = 1.0W, f = 1kHz 55 k Ω
V V
+0
3
= ± 17V, Rg = 10k Ω
CC
= ± 17V –70 0 +70 mV
CC
= 8 Ω , Rg = 600 Ω , VG = 40dB,
L
6W
6W
–2 –5 –10 V
1.2 mVrms
Unit (capacitance:F)
Specified Transformer Power Supply
(Equivalent to RP-22)
Equivalent Circuit
No. 2324—2/8
STK4102 II
Sample Application Circuit (I)
6W min 2-channel AF Power Amplifier
Sample Printed Circuit Pattern for Application Circuit
(Cu-foiled side)
No. 2324—3/8