SANYO STK404-130S Service Manual

SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
Ordering number : ENN7730
52004TN (OT) No.7730-1/5
Overview
The STK404-000S series products are audio power amplifier hybrid ICs that consist of optimally-designed discrete component power amplifier circuits that have been miniaturized using SANYO’s unique insulated metal substrate technology (IMST). The adoption of a newly-developed low thermal resistance substrate allows this series of devices to be provided in miniature packages significantly more compact than earlier Sanyo products with similar specifications.
Features
• Series of pin compatible power amplifiers ranging from 45W to 180W (10%/1kHz) devices. The same printed circuit board can be used depending on the output power grade.
• Miniature packages — 30W to 40W (THD=0.4%, f=20Hz to 20kHz); 44.0mm × 25.6mm × 8.5mm * — 50W to 80W (THD=0.4%, f=20Hz to 20kHz); 46.6mm × 25.5mm × 8.5mm * — 100W to 120W (THD=0.4%, f=20Hz to 20kHz); 59.2mm × 25.5mm × 8.5mm *
*: Not including the pins.
• Output load impedance: RL=6
• Allowable load shorted time: 0.3 seconds
• Built-in thermal protection circuit
• Supports the use of standby, muting, and load shorting protection circuits.
SANYO Semiconductors
DATA SHEET
STK404-130S
Thick-Film Hybrid IC
One-Channel Class AB Audio Power Amplifier IC 100W
Any and all SANYO products described or contained herein do not have specifications that can handle applications that require extremely high levels of reliability, such as life-support systems, aircraft's control systems, or other applications whose failure can be reasonably expected to result in serious physical and/or material damage. Consult with your SANYO representative nearest you before using any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all SANYO products described or contained herein.
Item
Type No.
STK404-050S STK404-070S STK404-090S STK404-100S STK404-120S STK404-130S STK404-140S Output 1 (0.4%/20Hz to 20kHz) 30W 40W 50W 60W 80W 100W 120W Output 2 (10%/1kHz) 45W 60W 80W 90W 120W 150W 180W Maximum supply voltage (6) ±37V ±43V ±46V ±51V ±59V ±64V ±73V Recommended supply voltage (6) ±26V ±30V ±32V ±35V ±41V ±45V ±51V Remarks Built-in thermal protection circuit Package 44.0mm × 25.6mm ×8.5mm 46.6mm × 25.5mm × 8.5mm 59.2mm × 25.5mm × 8.5mm
Series Organization
These products are organized as a series based on their output capacity.
No.7730-2/5
STK404-130S
8.5
0.4
2.9
5.5
1
13
52.0
59.2
(10.76)
12
×
2.54=30.48
3.6
0.5
2.54
11.0
16.0
25.5
20.84.0
5.6
Package Dimensions
unit : mm 4205
SANYO : SIP13
Specifications
Maximum Ratings at Ta = 25°C
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage (No signal) V
CC
max(0) ±70 V
Maximum supply voltage V
CC
max(1) RL=6 ±64 V Thermal sensor maximum voltage Vp Between pins 1 and 2 16 V Thermal sensor maximum current Ip Between pins 1 and 2 30 mA Thermal resistance
θj-c Per power transistor 1.3 °C/W
Junction temperature Tj max
Both the Tj max and the Tc max conditions must be met.
150 °C IC substrate operating temperature Tc max 125 °C Thermal sensor operating temperature *
2
Tp max 145 °C Storage temperature Tstg –30 to +125 °C Allowable load shorted time *
4
ts VCC=±45.0V, RL=6, f=50Hz, PO=100W 0.3 s
Notes: 1. Unless otherwise noted, use a constant-voltage supply for the power supply used during inspection.
2. The thermal sensor temperature (+125 to +145°C) is designed to prevent incorrect operation, but does not guarantee continued operation of the hybrid IC. The total integrated time this device spends operating in the temperature range +125 to +145°C must not exceed 12 hours.
3. The output noise voltage values shown are peak values read with a VTVM. However, an AC stabilized (50Hz) power supply should be used to minimize the influence of AC primary side flicker noise on the reading.
4. Use the transformer power supply circuit shown in the figure below for allowable load shorted time measurement and output noise voltage measurement.This IC is designed assuming that applications will provide a load-shorting protection function that operates within 0.3 seconds of the load being shorted and that either cuts off power to the IC or eliminates the load-shorted state in some other manner.
Parameter Symbol
Conditions*
1
Ratings
Unit
V
CC
(V) f (Hz) PO(W) THD (%) min typ max
Output power
P
O
(1) ±45.0 20 to 20 k 0.4 100
W
P
O
(2) ±45.0 1 k 10 150
Frequency characteristics f
L
, f
H
±45.0 1.0 +0 –3 dB
20 to 20 k
Hz Input impedance ri ±45.0 1 k 1.0 55 k Output noise voltage *
3
V
NO
±54.0 Rg = 10 k 1.2 mVrms
Quiescent current I
CCO
±54.0 No loading 50 mA
Neutral voltage V
N
±54.0 –100 0 +100 mV Thermal sensor resistance Rp Tp=25°C, between pins 1 and 2 470 Thermal sensor temperature Tp Rp=4.7k, between pins 1 and 2 145 °C
Operating Characteristics at Tc=25°C, RL=6(noninductive load), Rg=600, VG=30dB
10000µF
10000µF
DBA40C
500
500
+V
CC
--V
CC
+
+
Designated Transformer Power Supply (MG-250 equivalent)
Loading...