Sanyo SAP-KRV9AG,SAP-KRV12AP,SAP-KRV18AG,SAP-KRV18AP,SAP-KRV9AP,SAP-KRV22AG,SAP-KRV12AG,SAP-KRV22AP Instruction Manual

INSTRUCTION MANUAL
FIRST MADE FOR SAP-KRV9, 12 18 and 22AG
MATERIAL OR MODEL *PAPER-JO
DIMENSION OR MAKER WOODFREE 55gm
COLOR BLACK Print
NOTE A4 SIZE
APPROVED BY
2010/OCT/31
APPROVALS DATE REVISIONS R.NO
DRAWN
REMARKS:
PART CODE
SAPL ONLY
852-6-4181-189-00
PART NAME
INSTRUCTION MANUAL
CHECKED BY
Andy Pui K. H.
2010/OCT/31
DESIGNED BY
2010/OCT/31
© SANYO 2010
SAP-KRV9AG & KRV9AP SAP-KRV12AG & KRV12AP SAP-KRV18AG & KRV18AP
SAP-KRV22AG & KRV22AP
COOL AND DRY MODEL
Pub. OI-85264181 189 00
This air conditioner uses
the new refrigerant R410A.
INSTRUCTION MANUAL
Inverter-Controlled Split System Air Conditioner
Save These Instructions!
2
FEATURES
This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner.
24-hour Clock with ON/OFF Program Timer
The remote control unit allows you to set a wide variety of timer-based operations including automatic ON/OFF with timer setting, same-time ON/OFF every day, ON timer, OFF timer and Combination timer.
Mild Dry
By coupling the compressor and fan operation, intermittent drying can be precisely controlled according to room temperature so that air is efficiently dehumidified.
Auto Clean
Fan operates when the unit is stopped to prevent the generation of mold and odors within the indoor unit.
Humanized Sleep Function
Temperature gently rises or falls automatically to maintain comfortable room temperature, saving energy.
Rapid Cooling (Heating)
The high-efficiency system cools quickly while maintaining high EER/COP.
Super Quiet
Specially designed air vent efficiently reduces noise.
Tur bo
Powerfully cools the room.
Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low, according to room temperature, to maintain a comfortable airflow throughout the room.
Air Sweep Control
The air sweep function automatically moves the air outlet flap up and down, directing air in a sweeping motion around the room and ensuring comfort in every corner.
Automatic Restart Function for Power Failure
Even when power failure occurs, preset programmed operation is reactivated once power resumes.
Self Diagnosis
Error code is displayed for fast and easy maintenance, should a problem occur.
Low Voltage Startup (Min.198V)
The unit starts safely even when the voltage is below the rated voltage.
Child Lock
Remote controller keys are lockable to prevent misoperation.
Blue Fin
Anti-corrosion blue fin is more effective than a common coil.
CONTENTS
Page
FEATURES.........................................................................................................................................2
PRODUCT INFORMATION ................................................................................................................3
ALERT SYMBOLS..............................................................................................................................3
INSTALLATION LOCATION................................................................................................................3
ELECTRICAL REQUIREMENTS........................................................................................................3
SAFETY INSTRUCTIONS.................................................................................................................. 3
1. USAGE POINTS ...........................................................................................................................4
2. NAMES AND FUNCTIONS OF PARTS ........................................................................................6
3. OPERATION OF WIRELESS REMOTE CONTROL UNIT............................................................7
4. CLEANING AND CARE ..............................................................................................................16
5. ADJUSTING THE AIRFLOW DIRECTION CORRECTLY...........................................................18
6. TROUBLESHOOTING................................................................................................................18
3
PRODUCT INFORMATION
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet.
Model No. __________________________________
Serial No. ___________________________________
Date of purchase _____________________________
Dealer’s address _____________________________
Phone number ________________
ALERT SYMBOLS
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
INSTALLATION LOCATION
We recommend that this air conditioner be installed properly by qualied installation technicians in accordance with the Installation Instructions provided with the unit.
Before installation, check that the voltage of the electric supply in your ho me or oce is the same as the voltage shown on the nameplate.
Avoid:
To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.
ELECTRICAL REQUIREMENTS
1. All wiring must conform to the local electrical codes.
Consult your d ealer or a qualied electrician for details.
2. Each u
nit must be properly grounded with a ground
(or earth) wire or th rough the supply wiring.
3. Wiring must be done by a qualied electrician.
SAFETY INSTRUCTIONS
Read this Instruction Manual carefully before using this air conditioner. If you still have any diculties or problems, consult your dealer for help.
This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in perso
nal injury or product or property
damage.
Do not install this air conditioner where there are fumes or ammable gases, or in an extremely humid space such as a greenhouse.
Do not install the air conditioner where excessively high heat­generating objects are placed.
CAUTION
Never use or store gasoline or other ammable vapor or liquid near the air conditioner — it is very dangerous.
This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suocation in an extreme case.
Do not turn the air conditioner on and o from the power mains switch. Use the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
Do not let children play with the air conditioner.
Do not cool or heat the room too much if babies or invalids are present.
CAUTION
4
1. USAGE POINTS
1.1 Working Principle and Special Functions for Cooling
Principle:
An air conditioner (cooling) absorbs room heat and transmits and discharges it outdoors, thereby decreasing the ambient indoor room temperature. Its cooling capacity will decrease relative to an increase in the outdoor ambient temperature.
Anti-freezing Function:
If the unit is running in COOL mode and at a low temperature, frost will form on the heat exchanger; when the indoor heat exchanger temperature decreases to below 0°C, the micro-computer of the indoor unit will stop running the compressor to protect the unit.
1.2 Working Principle and Special Functions for Heating
Principle:
1. An air conditioner (heating) absorbs heat from outdoors and transmits it indoors
, thereby increasing the indoor room temperature. Its heating capacity will decrease relative to a decrease in the outdoor ambient temperature.
2. If the outdoor temperature is lower than the room temperature, please operate the system with other heating/ventilating equipment.
Defrosting:
1. When the outdoor temperature is low and there is high humidity, after the unit runs for a while, frost will form on the outdoor unit and aect the heating function. At this time, the auto-defrosting function will turn on, and the heating operation will stop for 8-10 minutes.
2. While the auto-defrosting function is operating, both the fan motors of the indoor and outdoor
units will stop operating.
3. While the defrosting function is operating, the indoor indicator ashes and the outdoor unit may emit vapor. This is due to the defrosting and is not a malfunction.
4. After defrosting has nished, the heating process will resume automatically.
Cold Draft Prevention:
In “HEAT” mode, the indoor blower will not act under the following 3 statuses, until the heat exchanger reaches a certain temperature. This is to prevent cool air from blowing. (Within 2 minutes)
1. When heating starts.
2. After auto-defrosting has nished.
3. Heating under low ambient temperature
Gentle Breeze:
Under the following conditions
, the indoor unit may produce a gentle breeze,
and the guide louver may rotate to a predetermined position:
1. In “Heat” mode with the unit turned on, until the compressor starts operationg
2. In “Heat” mode with the temperature at the set value and the compressor has stopped running at about 1 minute.
** For Heatpump models Only **
5
1. USAGE POINTS
1.3 Working Temperature Range
Temperature Indoor Air Temperature Outdoor Air Temperature
COOLING
Max. 32°C DB / 23°C WB 43°C DB / 26°C WB
Min. 19°C DB / 14°C WB 19°C DB
6
2. NAMES AND FUNCTIONS OF PARTS
S/n Part Name
(1) Power cable
(2) Remote control unit
(3) Front panel
(4) Filter
(5) Guide louver
(6) Wall pipe
(7) Bind tape
(8) Drainage pipe
Outdoor Unit
Indoor Unit
Air intake
Air outlet
Wireless remote
control unit
Air intake
Air outlet
Dry
Run
Receive
window
SET TEMP
Cool
ON/OFF
ON / OFF
COOL DRY
RUN
Loading...