SANYO’s MIR and MLR series incubators have been
recognized as exceptional units suitable for a wide
range of applications. The wide variety of temperatures,
humidity and lighting patterns that are essential in
research, environmental studies and testing can now be
accurately reproduced and controlled.
Models: MLR-351H & MIR-254
Page 2
New MIR-154, MIR-254 and MIR-554 Incubators
Wide Range of Applications
The MIR 154, 254 and 554 refrigerated
incubators are ideal in testing applications
such as
• Industrial testing in the electrical, machinery,
textiles industries
• Chemical testing e.g., storage, stability, acid/alkali, durability
• Food industry for packaging, quality control and stability
• Testing for waste water, BOD, soil testing
• Microorganism culturing
• Germination experiments
Flexibility
The SAYNO MIR series offers accurate temperature control and
uniformity in a wide range of temperatures, making them suitable
for various applications.
• The MIR-154, 254 and 554 are programmable with 12 step, 10
program capability.
• Wide temperature range that goes from -10°C up to +60°C
• Excellent temperature uniformity
• ON-OFF control of chamber lighting – controlled by programming
Programming
• Numeric input with keypad
• Booking of operation start date and hour with delay start timer
• Both clock mode and count down mode can be used for program
setting
New LCD Controller
The new LCD Controller improves user interface for better
programming and control
• Display – pop up menu that can display:
• Current conditions (temperature, date, time (12 hour or
24 hour selectable)
• Alarm condition
• Status of door and light
• Light status
• Various settings of each program (12 step, 10 program,
clock function and join mode)
• 2 weeks of data (recorded data can be forwarded to PC
with optional MTR-480)
Improved Usability
• Modern design and reversible door capable (MIR-154/254)
• Improved gentle air circulation that reduces media drying
• Adjustable low vibration for sensitive materials testing
• Full alarm package
Options
• Double stacking option with spacer (only for MIR-154) Model #
MIR-S154SB
• Key Mounting Plate: MIR-LP (Only for MIR-154/254)
• Lighting addition kit: MIR-LP15 (Only for MIR-154/254)
• Light shading plate for glass: MIR-154BP/MIR-254BP
Programmable 3-step operational functions
with microcomputer control
Program input is simple and the steps during each operation
are indicated via the LCD display. This incubator accommodates
a range of diversied experimentation requirements, and
is ideal for experimentation during night time or holidays,
experimentation that requires settings to be changed, and
microorganism culture and preservation. Constant operation
mode without step operation is also available.
3 Step Repeat Operation
Temperature (T1, T2, T3) and Time (H1, H2, H3) are set. Then, limited
repeating operations (from 1 to 99 times) or continuously repeated
operations are conducted. After a limited repeating operation has
been completed, constant operating temperature T0 is retained.
Application: Optimum for repeated experiments in which 3 different
elemental temperatures and times are combined.
Page 3
The MIR Series accommodates a wide range of temperatures
High-precision Temperature Environment
SANYO Refrigerated Incubators incorporate a high precision
microprocessor temperature control combined with a heater P.I.D.
and compressor ON-OFF system. This system has a feed forward
function that inputs the operating conditions of the compressor
beforehand, ensuring accurate temperature control for the chamber.
In a wide temperature range from -10°C to 60°C, the heater P.I.D.
exhibits temperature uctuation up to 0.2°C, and the Compressor
ON-OFF controls precisely ±1.5°C. In addition, the uctuation of
temperature uniformity in the chamber is within ±0.5°C, allowing a
full range of precise experimentation from microorganism cultures
to various types of incubation and testing.
Energy Savings
In addition to a microprocessor-controlled high efcient heater
output and compressor ON/OFF, a renewal control program and
low heat-emission inner chamber fan are newly adopted that
allow high-energy saving operation over a wider range of ambient
environments.
Foamed-in-place Rigid Polyurethane Insulation
HCFC-free foamed-in-place polyurethane is used for the chamber
because of its high thermal retention and energy saving properties.
Triple-pane Glass Observation Window plus
Programmable 15W Fluorescent Lamp
An easy-to-observe triple-pane glass observation window and
15W uorescent lamp are provided for sample observation during
experimentation. When observation is not required, an optional light
shielding plate (MIR-154/254) can be easily attached. The MIR-554
has an observation door included.
Alarm and Security System to Protect
Sample Safety
Automatic Setting Temperature Alarm
When the chamber temperature deviates more than ±1 to ±5°C
(user selectable), all digits of the digital indicator ash. Fifteen
minutes later a buzzer will sound. This system also automatically
allows programmed operation or setting value changes.
Independent Over-temperature Protection Device
This incubator incorporates an excessive temperature prevention
circuit that protects experimentation materials in the rare event
that a temperature abnormality does occur. Isolated from the
main circuit, this exclusive circuit and sensor operate even if the
temperature sensor or microprocessor malfunction, activating
an exclusive lamp and buzzer notication. This system turns off
the heater and chamber fan motor when over temperature is
detected (setting temperature range: 15°C~65°C), and turns off
the compressor when under temperature is detected (setting
temperature range -15°C to 20°C). Remote alarm contacts are
provided for monitoring alarm from a remote location.
Programmed Memory Back-up Mechanism
Should the power source be interrupted due to power failure or
other event, programmed data remains stored in memory semipermanently. When the power source is restored, operation can be
continued according to the predetermined program.
Automatic Return Buzzer Switch
After an power failure occurs, the alarm buzzer automatically
switches to the ON mode, even if the operator forgets to return
the alarm buzzer to the ON mode, thus ensuring safe and secure
operation.
Key Lock
A key lock switch is provided so that settings may not be changed
unintentionally.
Auto Return Mechanism
This mechanism automatically returns the chamber temperature
indicator to its normal indication when the control key is not
operated for approx. 90 seconds at each setting mode. Thus, normal
operation is ensured even if the operator forgets an operational
procedure during setting.
Trouble Monitor (Self Diagnostic Function)
Should a malfunction occur, the location of the malfunction can be
digitally indicated, allowing quick operator response.
3 Step to Constant Operation
Temperature of T1, T2, and T3, correspond to times H1, H2, and H3,
respectively. Then, constant operation temperature T0 is retained.
Application: Optimum for experiments that require consistent 4-step
temperature increases and decreases.
2 Step to Repeating Operation
Using a temperature T1 and T2, operation is repeatedly conducted
using time H1 and H2. Application: Optimum for day and night cycle
operations of plant material or quality testing for chemicals, foods
and samples.
2 Step to Constant Operation
With a temperature of T1 and T2, operation is conducted using time
H1 and H2. Then, constant operating temperature T0 is retained.
1 Step to Constant Operation
With a temperature of T1, operation is conducted using time H1.
Then, constant operating temperature T0 is retained.
Application: Optimum for automation and labor savings while
performing bacteria inspection from culture to preservation, and from
preservation to culture.
Page 4
Incubation & Testing
MIR-554
800 x 832 x 1810
(31.5 x 32.8 x 71.3)
640 x 550 x 1160
(25.2 x 21.7 x 45.7)
406 (14.3 cu.ft.)
Galvanised steel with baked-on finish,
triple-pane glass with observation door
5
Singlephase,Output250W
Cord heater 322W
380/440W
195kg (429.9 lbs.)
Key 1 set
Versatile incubators meet a wide range of experimental needs with expanded temperature control range and enhanced functions
5
—
800 (31.5)
14
(0.6)
14
(0.6)
35
(1.4)
15
(0.6)
640 (25.2)
198 (7.8)
200
(7.9)
800 (31.5)
410 (16.1)
1400 (55.1)
1810 (71.3)
832 (32.8)
105
(4.1)
972 (38.3)
755 (29.7)
405 (15.9)
1110 (43.7)
MIR-554
800 x 832 x 1810
(31.5 x 32.8 x 71.3)
640 x 550 x 1160
(25.2 x 21.7 x 45.7)
406 (14.3 cu.ft.)
Galvanised steel with baked-on finish,
triple-pane glass with observation door
5
Singlephase,Output250W
Cord heater 322W
380/440W
195kg (429.9 lbs.)
Key 1 set
Versatile incubators meet a wide range of experimental needs with expanded temperature control range and enhanced functions
MIR-154
700 x 580 x 1018
(27.6 x 22.8 x 40.1)
620 x 368 x 555
(24.4 x 14.5 x 21.9)
123 (4.3 cu.ft.)
3
Singlephase,Output150W
Cord heater 141W
205/235W
78kg (172.0 lbs.)
—
MIR-254
700 x 580 x 1618
(27.6 x 22.8 x 63.7)
620 x 368 x 1088
(24.4 x 14.5 x 42.8)
238 (8.4 cu.ft.)
Galvanised steel with baked-on finish
Stainless steel
Galvanised steel with baked-on finish, triple-pane glass
PE coated steel wire, adjustable
5
Foamed-in-place rigid polyurethane
Forced air circulation
Hermetic type
Singlephase,Output250W
Fin and tube type, forced circulation
Wire and tube type natural air cooling system
Manual / Automatic
Cord heater 218W
Digital setting with keylock, digital display
Microprocessor PID system (when compressor operates, ON-OFF control)
Thermistor
When temperature deviates approx. 2.5 degrees, visual and audible alarm
Visual and audible alarm
12-step repeat from 1 - 98 times or unlimited. Max. 10 programs memorised.
–10C to +60C (Ambient temperature: +5C to +35C, No load)
0.2 degrees at Heater PID control (SV 50C, AT 20C, No load)
1.5 degrees at Compressor ON-OFF control (SV 5C, AT 20C, No load)
0.5 degrees (Setting temperature 37C, Ambient temperature 20C, No load)
260/280W
15W x 1, Fluorescent lamp (Setting temperature +5C to 50C)
108kg (238.1 lbs.)
—
200
(7.9)
28 (1.1)
1518 (59.8)
100 (3.9)
150
(5.9)
800 (31.5)
700 (27.6)
620 (24.4)
15
(0.6)
450 (17.7)
580 (22.8)25
(1.0)
858 (33.8)
1155 (45.5)
65 (2.6)
368
(14.5)
43 (1.7)
42 (1.6)
260
(10.2)
200
(7.9)
800 (31.5)
14
(0.6)
14
(0.6)
35
(1.4)
15
(0.6)
640 (25.2)
198 (7.8)
200
(7.9)
800 (31.5)
410 (16.1)
1400 (55.1)
1810 (71.3)
832 (32.8)
105
(4.1)
972 (38.3)
755 (29.7)
405 (15.9)
1110 (43.7)
MIR-554
800 x 832 x 1810
(31.5 x 32.8 x 71.3)
640 x 550 x 1160
(25.2 x 21.7 x 45.7)
406 (14.3 cu.ft.)
Galvanised steel with baked-on finish,
triple-pane glass with observation door
5
Singlephase,Output250W
Cord heater 322W
380/440W
195kg (429.9 lbs.)
Key 1 set
Specifications
s Appearance and specifications are subject to change without notice.
Caution: SANYO guarantees the product under certain warranty conditions. SANYO in no way shall be responsible for any loss of content or damage to content.
MIR-154
700 x 580 x 1018
(27.6 x 22.8 x 40.1)
620 x 368 x 555
(24.4 x 14.5 x 21.9)
123 (4.3 cu.ft.)
3
Singlephase,Output150W
Cord heater 141W
205/235W
78kg (172.0 lbs.)
—
MIR-254
700 x 580 x 1618
(27.6 x 22.8 x 63.7)
620 x 368 x 1088
(24.4 x 14.5 x 42.8)
238 (8.4 cu.ft.)
Galvanised steel with baked-on finish
Stainless steel
Galvanised steel with baked-on finish, triple-pane glass
PE coated steel wire, adjustable
5
Foamed-in-place rigid polyurethane
Forced air circulation
Hermetic type
Singlephase,Output250W
Fin and tube type, forced circulation
Wire and tube type natural air cooling system
Manual / Automatic
Cord heater 218W
Digital setting with keylock, digital display
Microprocessor PID system (when compressor operates, ON-OFF control)
Thermistor
When temperature deviates approx. 2.5 degrees, visual and audible alarm
Visual and audible alarm
12-step repeat from 1 - 98 times or unlimited. Max. 10 programs memorised.
–10C to +60C (Ambient temperature: +5C to +35C, No load)
0.2 degrees at Heater PID control (SV 50C, AT 20C, No load)
1.5 degrees at Compressor ON-OFF control (SV 5C, AT 20C, No load)
0.5 degrees (Setting temperature 37C, Ambient temperature 20C, No load)
260/280W
15W x 1, Fluorescent lamp (Setting temperature +5C to 50C)
108kg (238.1 lbs.)
—
200
(7.9)
28 (1.1)
1518 (59.8)
100 (3.9)
150
(5.9)
800 (31.5)
700 (27.6)620 (24.4)
15(0.6)
450 (17.7)
580 (22.8)25
(1.0)
858 (33.8)
1155 (45.5)
65 (2.6)
368
(14.5)
43 (1.7)
42 (1.6)
260
(10.2)
200
(7.9)
65 (2.6)
100
(3.9)
80
(3.1)
420 (16.5)28 (1.1)
918 (36.1)
1018 (40.1)
200
(7.9)
620 (24.4)
700 (27.6)
15 (0.6)
858 (33.8)
555 (21.9)
200
(7.9)
450 (17.7)
580 (22.8)25
(1.0)
368
(14.5)
Dimensions
Unit : mm (inch)
800 (31.5)
14
(0.6)
14
(0.6)
35
(1.4)
15
(0.6)
640 (25.2)
198 (7.8)
200
(7.9)
800 (31.5)
410 (16.1)
1400 (55.1)
1810 (71.3)
832 (32.8)
105
(4.1)
972 (38.3)
755 (29.7)
405 (15.9)
1110 (43.7)
Model
Exterior dimensions(W x D x H) mm (inch)
Interior dimensions(W x D x H) mm (inch)
Effective capacity
Exterior finish
Interior finish
Door
Shelves
Insulation
Circulation system
Compressor
Evaporator
Condenser
Defrosting system
Heater
Temperature setting indication
Temperature control
Temperature sensor
Automatic setting temperature alarm
Over temperature protection device
Programmed operation
Temperature range
Temperature fluctuation
Temperature uniformity
Total power consumption
Interior lamp
Net weight
Accessories
MIR Series Refrigerated Incubators
MIR-154
MIR-254
Effective Capacity:
4.3 cu.ft.
(123 liters)
MIR-154
Graphic LCD
Effective Capacity:
8.4 cu.ft.
(238 liters)
MIR-254
LCD Contrast
Control for
Controls for High &
Low Temp. Alarm
Character
input keys
Effective Capacity:
14.3 cu.ft.
(406 liters)
MIR-554
MIR-554
Menu
Button
Selection &
Enter Keys
Page 5
Incubation & Testing
MLR-351H Environmental Test Chambers with Humidity Control
The microprocessor P.I.D. and refrigeration capacity control
minimizes temperature uctuations and thereby improves
temperature control. This allows precise experiments plus energy
and electricity savings.
Programming of temperature, light, and humidity can be used for
small plants, environmental tests, algae, drosophila, etc.
Easy calibration of temperature and humidity can be calibrated
easily through the control panel. Small lightweight, high molecular
membrane-type humidity sensor also boasts a high degree of
accuracy and reproducibility.
Graphic LCD panel with pop-up menu function on control panel
provides visual display of operation and allows intuitive operation.
Versatile Environmental Test Chamber
• Graphic LCD provides easier operation
• Programmable temperature, lighting and humidity function
• Microprocessor P.I.D. temperature control
• Data logging function
• Easy calibration through controller
• Small lightweight, high molecular membrane-type humidity sensor
Feature and Benefits
Microprocessor P.I.D. controls temperature and humidity to create
the optimum environments for various applications.
Programmable Temperature Function can operate 12 step programs
x 10 patterns which can be stored, select a clock or timer mode,
multiple programs can be ‘connected’ (join mode), and a starting day
and time of operation can be programmed.
Automatic Data Logging of Operational Data of approximately two
weeks (6 minute intervals) can be automatically recorded. The
data can be viewed on the control panel. The data can also be
transmitted to a PC via RS-232C, interface board (MTR-480 required)
Technology and Applications
The wide variety of temperatures, humidity and lighting patterns
that are essential in research and environmental studies can now be
accurately reproduced and controlled.
27.6" x 22.8" x 40.1" 27.6" x 22.8" x 63.7"31.5" x 32.75" x 71.3".
(700 x 580 x 1018mm) (700 x 580 x 1618mm)(800 x 832 x 1810mm)
Interior Dimensions
(W x D x H)
(620 x 386 x 555mm)(620 x 386 x 1088mm)(640 x 550 x 1160mm)
Exterior Finish
Interior Finish
Door
Shelves
355
Insulation
Circulation System
Compressor
150W250W250W
Evaporator
Condensor
Defrosting System
Heater
141 W218 W332 W
Temp. Setting Indication
Temperature Control
Temperature Sensor
Autom. Setting temp. alarm
Over temp. protection device
Programmed Operation
Temperature Range
Temperature Controllability
12-step repeat from 1-98 times or Continuous repeat
Forced air circulation
Manualstart, automatic finish,
natural vaporisation ofdrain water
Cord Heater
-10ºC to +60ºC
±0.2ºC at heater PID control (Temp. setting 50ºC, ambient temp. 20ºC, no load)
Galvanized Steel with baked on finish
Selectable manual start or timer defrost,
natural vaporisation of drainwater
24.4" x 15.2" x 21.9"24.4" x 15.2" x 42.8"25.17" x 21.65" x 45.68"
Painted Steel & Triple pane glass
with observation door and key
MIR-262
Model No.MLR-351H
Effective Capacity10.4 cu.ft. (294L)
Exterior Dimensions29.9" x 27.6" x 72.2"
(WxDxH)760 x 700 x 1.835mm
Interior Dimensions20.5" x 19.3" x 44.7"
(WxDxH)520 x 490 x 1.135mm
ExteriorPainted Steel Left/right wall: paired glass window
(14.6 x 43.7inch / 370 x 1.110mm)
InteriorStainless steel (SUS-304)
DoorBaked-on acrylic finish on galvanized steel with fluorescent
lamps
Inner DoorPaired glass door
Shelves5pcs. PE coated steel wire (bottom shelf with stainless
steel cover), adjustable
Access Hole1.574in dia. 1x (chamber top position)
Casters4pcs.
Air CirculationForced air circulation
CompressorFully hermetic, 325W output
EvaporatorFin and tube type, forced circulation
RefrigerantR404A
Heater340W
Defrosting SystemAutomatic defrost (3 patterns), manual defrost
Temperature
Temperature Range5°C~50°C (lamp OFF) 10~50°C (lamp ON)
Temperature Distribution±1.0°C (lamp OFF) ±2.5°C (lamp ON)
Temperature Accuracy±0.3C
Temperature ControlPID microprocessor contol + refrigeration capacity control
Temp. Programmable12 steps (10 patterns), 98 cycle or limitless;
OperationsClock mode: 00:00~23:59, Timer mode: 00:01~99:59
lamp 40W x 15pcs.
Lighting ProgrammableLighting levels: 6 (0,1,2,3,4,5) max. 12 steps (10 pattern)
Operations1-98 cycles repeat or unlimited
Humidity
Control SystemUltrasonic PID control
Control Range55-86% & 60-90% RH
Alarm & Security
AlarmsTemp. alarm, High & low temp. unit, Humidity alarm
Product conforms to RoHS (European
Restriction of Hazardous Substance
directives)
SANYO Electric Co.,Ltd., Biomedical
Division, Gumma is certied for
Quality management system:ISO9001/
Medical devices Quality management
system:ISO13485/Environmental
management system:ISO14001