SPECIFICATIONS
PRECAUTIONS
ELECTRICAL
Current dissipation: 110 mA (Colored: 76 mA) Power Consumption: 1,08 W (Colored: 0,92 W) Operating power : DC 12V Maximum serial connection : 25 modules Electronic dimming control supported Constant current drive, Reverse voltage protection
THERMAL
Cooling : Ambient air Maximum operating temperature : 60˚C (140˚F) Minimum operating temperature : -25˚C (-13˚F) Maximum storage temperature : 60˚C (140˚F) Minimum storage temperature : -30 C (-22 F)
IP63
PHYSICAL
Use precautions to avoid damages to the product or injuries of users. Any actions against following contents will cause serious issues such as malfunction, electric shock, or burn.
DC12V
AC
USE DC12V ONLY
DO NOT USE AC INPUT
Do not cut or rejoion wires while product is connected wth live power source
Do not perform actions listed below
- Alter or modify
- Touch LED lamps with sharp objects
- Put glue or silicon over the LED lamps
Maximum driver quantity per serial connection is limited. Failure causes overload of current and damages to the product
PREPARATION
Avoid performing installation under rain or high humidity for outdoor use
Do not use the product under circumstances listed below
- High temperature spots over 60˚C (140˚F)
- Spots draw extreme moisture or dust
SUPPLIES REQUIREDTOOLS REQUIRED
Wire Stripper, Drill, Screw Driver, Wiper
PREPARE CHANNELS
1. Clean moisture and dust inside 2. Make holes 3. Use bushing to protect wires
Wire Nuts, Cable Ties, IDC Connectors, VCTF(PLTC) Cable, (Optional : Silicon and Screws)
Refer to ‘WIRE THICKNESS’ table to use proper
LED module Failure will cause dimmed output
module is limited. Refer to ‘CONNECTION WITH POWER SUPPLY’ on page 2
2. Make holes for wires from modules to SMPS.
3. Without bushins, wires will easily be cut and short-circuit will occur.
FARD lighting GmbH Seestrasse 20 D - 14974 Ludwigsfelde OT Genshagen
Tel. +49 - (0)3378 / 2003-0 Fax +49 - (0)3378 / 2003-29
info@fard-lighting.de www.fard-lighting.de
User Guide
STAR C0640
2
LAYOUT DENSITY
GUIDELINES
CONNECTION GUIDE
Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface.
RECOMMENDED CENTER OF MODULE PITCH PER MINIMUM DEPTH
60 mm
70 mm
RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH
80 mm
Maximum driver quantity per serial connection is limited. Using more quantity per run will cause overload from SMPS which damages all connected products. This will cause voltage drop and also dimmed lighting output.
60 mm
AC Input
DC Output
80 mm
Power Supply
120 mm
180 mm
200 mm
*Ensure that each run should have 25 modules at max and should use another run in parallel to connect more
Should use thicker wires which can take larger amount of current than the amount transmitted from the power supply unit
120 mm
400 mm
300 mm
0460C0430C0230C0320C
CONNECTION WITH
POWER SUPPLY
CAUTION
Keep extension lead wires as short as possible. Refer to below table for
1st
25th
EXTENSION OF POWER SUPPLY LEAD WIRES
Model Name
Output (W)
Output (A)
STAR C0640 19pcs 37pcs 73pcs 365pcs 610pcs
Recommended
Extension Wire
Maximum Length
PSGE-0030-12
30W
2.5A
VCTF1.25
AWG18
5M (15FT)
1st
25th
*When mixed run should occur, count 1(one) for C0230, C0320, and C0340
**Must count C0640 as 2(two) and keep the total counts under 50
PSGE-0060-12
60W
5A
VCTF2.0
AWG14
5M (15FT)
1st
25th
PSGE-0120-12
120W
10A
VCTF2.0
AWG12
5M (15FT)
25th
PSGE-0600-12**
600W
50A
VCTF5.5
AWG4
15M (50FT)
PSGE-1000-12**
1st1st
1000W
83A
VCTF8.0
AWG2
15M (50FT)
**PSCS-0600-12, PSCS-1000-12 are not weather-proof Equip with protective box for outdoor use and the box should have ventilating holes
FARD lighting GmbH Seestrasse 20 D - 14974 Ludwigsfelde OT Genshagen
Tel. +49 - (0)3378 / 2003-0 Fax +49 - (0)3378 / 2003-29
User Guide
0
0
3STAR C0640
INSTALLATION GUIDE
1. DETERMINE LAYOUT
Stroke Width
Channel Depth
Refer to ‘LAYOUT DENSITY GUIDELINES’ on page 2 to determine spacing and amount of LEDs required.
2. PEEL AND STICK
Attention to : John Do e Page 1 of 1
1000 mm
34 6 22 34 41
MATERIAL ESTIMATE
NUMBER OF SETInformation
1
QUANTITY PER SET 143EA
TOTAL CLUSTERS 143EA
WATTAGE PER SET 187W
SUMMARY
TOTAL WATTAGE 187W
S-LED ESTIMATE /SET
120mm
MODULE PITCH
*This is for estimating purposes only. Material Estimates for S-LED system are based upon given font, letter height, depth, face material, and any special instructions. *All signs should be tested for acceptable color, illumination and operation. Use appropriate power supply for testing
POWER ESTIMATE /SET
*For detailed information, please refer to the applicable S-LED product found under http://www.daehantrans.com/download/products2007.pdf
ytitnauQylppuS rewoPledoM Color Quantity
Drawn by Brad Han
2W021 V21CDAE341ETIHW40C RATS
Date : 2009. 1. 1.
Tel : +82 32 858 0491
Rev. 0
www.daehantrans.com
SUPPORTS FOR OUR SIGNMATES
Ask us to obtain accurate layout
3. CAP ALL UNUSED WIRES
Wire Nut
Fax : +82 32 832 8421 bhan@daehantrans.com
lies
Using predetermined layout and LED placement from step 1, remove 3M tape on the back of modules
attached on the surface.
CAUTION
When handling the module, avoid pressing down directly on top of LED lamp
4. CONNECT WITH POWER SUPPLY
DC Output
AC Input
12
DC Output
12
AC Input
Using predetermined layout and LED placement from step 1, divide channels into sections and distribute each section to corresponding power supplies.
CAUTION
Before connect with power supplies, check polarity on every connections
The strand of modules should not be looped to create a closed circuit.
5. FIX MODULES PERMANENTLY
SILICON : If desired, modules can be secured with
silicon. Do not to put silicon on the top of the LED lamps.
FARD lighting GmbH Seestrasse 20 D - 14974 Ludwigsfelde OT Genshagen
Tel. +49 - (0)3378 / 2003-0 Fax +49 - (0)3378 / 2003-29
User Guide
4STAR C0640
TROUBLE SHOOTING
Entire sign or leg does not light after complete installation.
Still does not light.
Still does not light.
Beginning of a leg lights, but the entire leg does not light or lights intermittently.
One module does not light, but all others in the leg light.
All modules light, but some of them are dimmed.
Dark spots or dimmed spots occur.
Still has spots.
Check connection from power supply lead to first module. Make sure polarity of connections made at the power supply lead and any jumper wire is correct. Power supply outputs should be connected red-to-red and white-to-white.
Check output voltage of power supply using a voltmeter. The output voltage should be
12.0VDC ± 0.5VDC. If there is no output voltage, have a licensed electrician check input voltage. Make sure power supply is connected correctly and getting primary power. If power supply is connected properly and getting primary power and there is still no output voltage, try a different power supply.
If power supply is getting primary power and the modules do not light, there may be a short in the secondary wiring. Check all connections and cap all loose wires.
The primary cause of a portion of a S-LED leg not lighting or lighting intermittently connection or reverse polarity connection between the modules that light and the modules that don’t light. Check this connection.
S-LED is designed so if one module fails, it will not cause the entire sign or leg to go out. If one module does not light, but all others in the leg do, replace this module with a new one.
Check each run has no more than maximum number of modules. Also ensure that type of the extension wire from SMPS to the first module is correct. If wires are not thick enough to transmit current from SMPS, this will cause voltage drop and will dim the modules at the end.
Channel depth is too low, or center distance between modules is too far. Refer to 'LAYOUT DENSITY GUIDELINES' for more information.
Covering acrylic is not intended for LED illumination. Use light diffusing acrylic sheets which are specially made for LED light source.
is a