Thank you for purchasing this Samsung product.
To receive more complete service,
please register your product at
www.samsungsecurity.com
English 1
GERSPA
ITAJAPRUSCZETUR
Safety information
C
9
2
3
4
5
6
7
8
9
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR
BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
1
1
This symbol indicates that dangerous voltage consisting a risk of
electric shock is present within this unit.
This exclamation point symbol is intended to alert the user to
the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
WARNING
To reduce the risk of fi re or electric shock, do not expose this appliance to rain
•
or moisture.
WARNING
1.
Be sure to use only the standard adapter that is specifi ed in the specifi cation sheet.
Using any other adapter could cause fi re, electrical shock, or damage to the product.
2.
Incorrectly connecting the power supply or replacing battery may cause
explosion, fi re, electric shock, or damage to the product.
3.
Do not connect multiple controllers to a single adapter. Exceeding the capacity
may cause abnormal heat generation or fi re.
4.
Securely plug the power cord into the power receptacle. Insecure connection
may cause fi re.
5.
When installing the controller, fasten it securely and fi rmly. The fall of controller
may cause personal injury.
6.
Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or
containers fi lled with water on top of the controller. Doing so may cause personal
injury due to fi re, electric shock, or falling objects.
7.
Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fi re
or electric shock.
8.
If any unusual smells or smoke come from the unit, stop using the product. In
such case, immediately disconnect the power source and contact the service
center. Continued use in such a condition may cause fi re or electric shock.
2 – COAXIAL REMOTE CONTROLLER
Safety information
If this product fails to operate normally, contact the nearest service center. Never
9.
disassemble or modify this product in any way. (SAMSUNG is not liable for
problems caused by unauthorized modifi cations or attempted repair.)
When cleaning, do not spray water directly onto parts of the product. Doing so
10.
may cause fi re or electric shock.
CAUTION
Do not drop objects on the product or apply strong blows to it. Keep away from a
1.
location subject to excessive vibration or magnetic interference.
Do not install in a location subject to high temperature (over 50°C), low
2.
temperature (below -10°C), or high humidity. Doing so may cause fi re or electric
shock.
If you want to relocate the already installed product, be sure to turn off the power
3.
and then move or reinstall it.
Remove the power plug from the outlet when there is a lighting storm. Neglecting
4.
to do so may cause fi re or damage to the product.
Keep out of direct sunlight and heat radiation sources. It may cause fi re.
5.
Install it in a place with good ventilation.
6.
Avoid aiming the controller directly towards extremely bright objects such as sun.
7.
Apparatus shall not be exposed to dripping or splashing and no objects fi lled with
8.
liquids, such as vases, shall be placed on the apparatus.
The Mains plug is used as a disconnect device and shall stay readily operable at
9.
any time.
ENG
English 3
Important Safety Instructions
Read these instructions.
1.
Keep these instructions.
2.
Heed all warnings.
3.
Follow all instructions.
4.
Do not use this apparatus near water.
5.
Clean only with dry cloth.
6.
Do not block any ventilation openings. Install in accordance with the
7.
manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, or other
8.
apparatus (including amplifi ers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A
9.
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong is provided for your safety. If the provided plug does not fi t into your outlet,
consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs,
10.
convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specifi ed by the
11.
manufacturer.
Use only with cart, stand, tripod, bracket, or table
12.
specifi ed by the manufacturer, or sold with the apparatus.
Unplug this apparatus when a card is used. Use caution
13.
when moving the cart/ apparatus combination to avoid
injury from tip-over.
Refer all servicing to qualifi ed service personnel. Servicing is required when the
14.
apparatus has been damaged in any way, such as powersupply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
4 – COAXIAL REMOTE CONTROLLER
Contents
Introduction
Introduction 6
Part names and functions 7
Installation
Checking Installation Environment 11
Installation precautions 11
Connection & Control
To Control the camera coaxial communications 12
To control the camera using RS-485 device
via coaxial communications 13
To control the camera using RS-232 device
via coaxial communications 14
To control the camera using RS-485 signal output 15
To control the camera using RS-485 signal
output via RS-232 communications 16
Switch Setting Table 17
Specifi cations
Specifi cations 20
Dimensions 21
ENG
English 5
Introduction
P
❶
❷
❸
❹
❖
q
r
p
o
n
INTRODUCTION
This product is a remote controller for Samsung’s CCTV cameras of New-generation
DSP, via coaxial cable not requiring additional control wirings.
Features
❖
Long-distance remote control
•
Through RS-485 communication, remote control is possible up to 1.2
kilometers.
Easy Control
•
Easy and simple 5-way keys for controlling the camera.
System’s Expandability
•
It is possible to implement an integrated system by using the system controller
(SSC-5000 or similar) through RS-485 communication.
Portability
•
Its small size and light weight maximizes the portability, as well as its power
source adopting standard battery for outdoor use.
List of controllable models
❖
You can control Samsung’s cameras supporting coaxial communications.
•
Samsung’s RS-485 supporting cameras can be controlled through RS-485
•
communication. (For supported 3rd-party protocols, refer to page 17.)
What’s Included
❖
<Controller><User Guide>
6 – COAXIAL REMOTE CONTROLLER
G
Introduction
PART NAMES AND FUNCTIONS
Front Panel❖
ENG
n
POWER
o
p
q
r
STATUS LED
❶
- Displays the status of the current operation.
POWER LED
❷
- When the controller turns on, it will be turn light.
POWER Switch
❸
- If you slide it to ON, the controller turns on.
CABLE COMPENSATION Switch
❹
- For long distance coaxial communications, you can use this switch for amplifying
the control signal.
Cable SPECCompensation
POWER
OFF ON
CABLE
COMPENSATION
SL
5C-HFBT
STATUS
ADDRESS
(X)100(X)10
3
3
2
2
4
4
1
1
5
5
0
0
6
6
9
9
7
7
8
8
1ON2345678
1ON2
TERMINATION PROTOCOL
(X)1
3
2
4
1
5
0
6
9
7
8
REMOTE CONTROLLER SCX-RD100
SL
250M or less 200M ~ 500M
s
t
English 7
Introduction
ON
356
8
PROTOCOL
1ON2
❖
P
N
RS-485 TERMINATION & PROTOCOL Setting Switch
❺
- You can select to set the RS-485 termination.
- Turn this switch ON, if RS-485 termination is required.
1ON2
1ON2345678
TERMINATION
- For multi-protocol settings, you can set the protocol and baud rate, and
selection of COAXIAL/RS-485 or RS-232.
1ON2
TERMINATION
TERMINATION
PROTOCOL
1ON2345678
PROTOCOL
- Use pin 1,2,3,4 of the Protocol setting switch to select a protocol.
- Use pin 5,6 of the Protocol setting switch to select a baud rate.
- Use pin 7 of the Protocol setting switch to select COAXIAL/RS-485 output.
- Use pin 8 of the Protocol setting switch to select RS-232 input.
❻
Address Switch
-
For RS-232 / RS-485 communications, you can use this switch to set the address.
ADDRESS
(X)100(X)10(X)1
3
2
4
1
5
0
6
9
7
8
3
2
4
1
5
0
6
9
7
8
3
2
4
1
5
0
6
9
7
8
- Set the address by using three switches shown above.
- From the left, the number is hundreds, tens and ones place, respectively.
The effective range of valid address is between 0 and 255 (1~255 for multiprotocol).
If you specify the address as other than between 0 and 255, it will be set to 0.
NOTE
❼
Menu Navigation Key
Use this to navigate through the menus.
8 – COAXIAL REMOTE CONTROLLER
Introduction
PART NAMES AND FUNCTIONS
Rear Panel❖
ENG
- AA BATTERY
.
You can use 4 AA-sized batteries for the power.
- The average operation time is 20 hours based on the alkaline battery.
(If the battery is discharged, it can cause a distortion of the video signal, or
electric interference.)
Remove the battery if you do not use the controller for a longer period. Otherwise, it
NOTE
may cause damage to the controller from a leak of the battery solution.
Take caution not to change the specified polarity.
Do not use a new battery with an old one.
For storing used batteries, keep out of reach of children. Wasted batteries are to be
collected separately.
English 9
Introduction
RS-232C
VIDEO
DC 12VRS-485
C
N
Top❖
REMOTE CONTROLLER SCX-RD100
TXRX
1ON23456781ON2
OUT IN
TERMINATION PROTOCOL
SL
COMPENSATION
(X)100 (X)10 (X)1
CABLE
ADDRESS
OFF ON
POWER
POWER STATUS
nop qr
USB Port
❶
This terminal is used for updating the product’s fi rmware.
-
❷
RS-232 Port (9-pin D SUB)
- Used to control remotely using RS-232 communication.
❸
RS-485 Port (4-pin)
- Used to control remotely using RS-485 communication.
❹
VIDEO IN/OUT Connector (BNC)
- VIDEO IN receives coaxial communication from cameras, and VIDEO OUT
outputs the video signal.
❺
DC12V Power Connector (2-PIN)
- Used for connecting DC12V power source.
I
10 – COAXIAL REMOTE CONTROLLER
Installation
CHECKING INSTALLATION ENVIRONMENT
Please check the following instructions before installation for your safety.
•
The way of connecting the main product with external devices (COAXIAL BNC)
•
is very important to build up a proper system.
Do not disassemble the unit; doing so could expose you to dangerous high
•
voltage points.
INSTALLATION PRECAUTIONS
Make sure you turn off the product before installation.
•
Do not put a strong force on or shake the product; otherwise it may cause
•
malfunction.
Keep the product away from areas of strong magnetic fi eld or electric
•
interference, or wireless devices such as radio or TV set.
Keep clean the installation place during and after the installation.
•
An abnormal smells from the product is a sign of abnormal condition, which
•
may cause fi re or electric shock. In this case, disconnect the product from
the main power immediately and contact the retailer for technical help from
authorized servicing.
Keep the product away from a wet fl oor, do not use an unearthed power
•
extension cable, worn-out power cord, neither forget earth-grounding.
Use a dry cloth only to dirt off the product. If the product is badly dirty, apply
•
neutral detergent on a cloth that is used to dirt off, and wipe it out with a dry
cloth.
Do not use volatile substances such as alcohol, benzene or thinner as these
•
may damage the fi nish.
ENG
English 11
Connection & Control
T
V
2
3
4
5
6
N
TO CONTROL THE CAMERA COAXIAL COMMUNICATIONS
REMOTE CONTROLLER SCX-RD100
TERMINATION PROTOCOL
1ON23456781ON2
SL
COMPENSATION
CABLE
(X)100 (X)10 (X)1
OFF ON
ADDRESS
POWER
POWER STATUS
Connect the product to DC 12V power source or insert 4 AA-sized
1.
batteries into the battery compartment.
Set the protocol switch 7 to ON.
2.
Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera
3.
directly.
For proper data communication, the unit and AI camera should be connected directly.
–
(If you connect a DVR or keyboard in the middle of the main unit and AI camera,
bidirectional communication will not be established.)
Connect VIDEO OUT of the main unit to a monitor’s video input terminal.
4.
Turn the Power switch ON.
5.
When it is powered on for the fi rst time, initialization begins and the status LED blinks
–
once completed. During the initialization, no operation is enabled.
Now you can control the camera by using the menus.
6.
1
You can use the menu as following :
❖
Press and hold [ENTER]: Moves to the main menu screen.
–
Press [ENTER] briefl y: Used to confi rm the current settings.
–
Four Direction Keys: Used to move the cursor up/down or left/right.
–
For proper coaxial communication, AI camera should be set to Samsung protocol.
–
Refer to the switch settings. (See page 17)
Control of pan/tilt/zoom using the keys is not supported.
–
12 – COAXIAL REMOTE CONTROLLER
Connection & Control
TO CONTROL THE CAMERA USING RS-485 DEVICE
VIA COAXIAL COMMUNICATIONS
REMOTE CONTROLLER SCX-RD100
TERMINATION PROTOCOL
1ON23456781ON2
SL
COMPENSATION
CABLE
(X)100 (X)10 (X)1
OFF ON
ADDRESS
POWER
POWER STATUS
Connect the product to DC 12V power source or insert 4 AA-sized
1.
batteries into the battery compartment.
Set the protocol switch 7 to ON.
2.
Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera
3.
directly.
For proper data communication, the unit and AI camera should be connected directly.
–
(If you connect a DVR or keyboard in the middle of the main unit and AI camera,
bidirectional communication will not be established.)
Connect VIDEO OUT of the main unit to a monitor’s video input terminal.
4.
Connect TX(+/-) of RS-485 device to RX(+/-) of the main unit.
5.
(For a full duplex system, connect RX(+/-) of RS-485 device to TX (+/-) of
main unit additionally.)
Using RS-485 device, you can control the camera menu.
6.
For proper coaxial communication, AI camera should be set to Samsung protocol.
–
Refer to the switch settings. (See page 17)
By factory default, protocols of SAMSUNG and PANASONIC are supported.
NOTE
For additional protocols, update the following software program via the web.
Input of video signal is required to control RS-485.
ENG
English 13
Connection & Control
T
O
2
3
4
5
❖
N
TO CONTROL THE CAMERA USING RS-232 DEVICE
VIA COAXIAL COMMUNICATIONS
REMOTE CONTROLLER SCX-RD100
TERMINATION PROTOCOL
1ON23456781ON2
SL
COMPENSATION
CABLE
(X)100 (X)10 (X)1
OFF ON
ADDRESS
POWER
POWER STATUS
Connect the product to DC 12V power source or insert 4 AA-sized
1.
batteries into the battery compartment.
Set the protocol switches 7 and 8 to ON.
2.
Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera
3.
directly.
For proper data communication, the unit and AI camera should be connected directly.
–
(If you connect a DVR or keyboard in the middle of the main unit and AI camera,
bidirectional communication will not be established.)
Connect VIDEO OUT of the main unit to a monitor’s video input terminal.
4.
Connect the RS-232 device’s cable to the RS-232 port of the main unit.
5.
Using RS-232 device, you can control the camera menu.
6.
The RS-232 device is the same as RS-485 regarding the protocol setting, but
–
supports only the Samsung protocol.
For proper coaxial communication, AI camera should be set to Samsung protocol.
–
Refer to the switch settings. (See page 17)
1
RS-232 and RS-485 communications cannot be used for simultaneous input.
NOTE
14 – COAXIAL REMOTE CONTROLLER
Connection & Control
TO CONTROL THE CAMERA USING RS-485 SIGNAL
OUTPUT
REMOTE CONTROLLER SCX-RD100
TERMINATION PROTOCOL
1ON23456781ON2
SL
COMPENSATION
CABLE
(X)100 (X)10 (X)1
OFF ON
ADDRESS
POWER
POWER STATUS
Connect the product to DC 12V power source or insert 4 AA-sized
1.
batteries into the battery compartment.
Set the protocol switches 7 and 8 to OFF.
2.
Connect the RX(+/-) of the unit to the RS-485 (+/-) port of the camera.
3.
Match the camera’s address, baud rate, and protocol to the same to
4.
those of the unit.
Now you can control the camera by using the menus.
5.
You can use the menu as following :
❖
Press and hold [ENTER]: Moves to the main menu screen.
–
–
Press [ENTER] briefl y: Used to confi rm the current settings.
–
Four Direction Keys: Used to move the cursor up/down or left/right.
Control of pan/tilt/zoom using the buttons is not supported.
–
To exit the menu screen, press and hold the key again.
ENG
Input of video signal is required to control RS-485.
NOTE
The next time you access the menu, press and hold the [ENTER] key twice.
English 15
Connection & Control
S
N
❖
❖
N
TO CONTROL THE CAMERA USING RS-485 SIGNAL
OUTPUT VIA RS-232 COMMUNICATIONS
REMOTE CONTROLLER SCX-RD100
TERMINATION PROTOCOL
1ON23456781ON2
SL
COMPENSATION
CABLE
(X)100 (X)10 (X)1
OFF ON
ADDRESS
POWER
POWER STATUS
Connect the product to DC 12V power source or insert 4 AA-sized
1.
batteries into the battery compartment.
Set the protocol switch 8 to ON.
2.
Connect the RX(+/-) of the unit to the RS-485(+/-) port of the camera.
3.
Match the camera’s address, baud rate, and protocol to the same to
4.
those of the unit.
RS-232 can be controlled using the Samsung protocol alone.
–
Connect the RS-232 device’s cable to the RS-232 port of the main unit.
5.
Using RS-232 device, you can control the camera menu.
6.
RS-232 and RS-485 communications cannot be used for simultaneous input.
NOTE
For the switch settings, see the switch setting table. (See page 17)
Input of video signal is required to control RS-485.
16 – COAXIAL REMOTE CONTROLLER
Connection & Control
SWITCH SETTING TABLE
Use a combination of pin 1,2,3,4 of the Protocol setting switch to select a protocol.
❖
1ON2
1ON23456781ON234
TERMINATION
Protocol Setting Switch (0 :r, 1 :q)
Pin 1Pin 2Pin 3Pin 4
0000SAMSUNGHALF
1000SAMSUNGFULL
1100PANASONICHALF
0010PANASONICFULL
1110PHILIPSHALF
1001KALATELHALF
0101ERNAHALF
1101DIAMONDHALF
0011VCL TPHALF
By default, it is configured to support SAMSUNG and PANASONIC.
NOTE
For other protocols, you can find assistance from our website at:
PROTOCOL
ProtocolHALF/FULL
HALF : half-duplex
FULL : full-duplex
http://www.samsungsecurity.com
Use pin 7 and 8 of the Protocol setting switch to set the coaxial output.
❖
PIN 7Output Selection
1ON23456787
PROTOCOL
1ON23456788
PROTOCOL
ONCOAXIAL out
OFFRS-485 out
PIN 8RS-232 input
ONRS-232 input
OFFRS-232 No use
ENG
RS-232 and RS-485 communications cannot be used for simultaneous input.
NOTE
English 17
Connection & Control
–
See the following table to set the baud rate.
1ON2
TERMINATION
1. SAMSUNG
2. PHILIPS
3. PANASONIC
4. DIAMOND, VCL TP
 Only supports 9600 bps
1ON234567856
BAUD RATEPIN 5PIN 6
38400 BPSOFFOFF
19200 BPSONOFF
9600 BPSOFFON
4800 BPSONON
BAUD RATEPIN 5PIN 6
38400 BPSOFFOFF
9600 BPSONOFF
BAUD RATEPIN 5PIN 6
19200 BPSOFFOFF
9600 BPSONOFF
4800 BPSOFFON
BAUD RATEPIN 5PIN 6
9600 BPSOFFON
PROTOCOL
18 – COAXIAL REMOTE CONTROLLER
Connection & Control
5. ERNA
BAUD RATEPIN 5PIN 6
2400 BPSONON
 Only supports 2400 bps
6. KALATEL
BAUD RATEPIN 5PIN 6
9600 BPSOFFON
4800 BPSONON
ENG
English 19
Specifi cations
D
SPECIFICATIONS
ItemDescription
COAXIAL
RS-232
RS-485
Environmental
Conditions
WEIGHTNET200 g
Communication MethodCOAXIAL INTERFACE
RangeMax. 500m (with 5C-HFBT cable)
Connector TypeD-SUB 9P
Port1 Port
BAUD RATE
Connector Type4P Terminal Type
Port 1 Port
BAUD RATE
USB PORT(USB2.0)S/W PROGRAM UPLOAD
VIDEO IN/OUT
Operating Temp.-10˚C ~ +50˚C
HumidityLess than 90%
POWERDC12V ± 10%
DIMENSIONS (WxHxD)150(W) X 36(H) X 102(D)
4800/9600/19200/38400bps
(Only Samsung protocol supported)
2400/4800/9600/19200/38400bps
(Supports each protocol)
Composite Video
1.0Vp-p, 75ohm,
Cable Compensation out
(Select:S/L)
20 – COAXIAL REMOTE CONTROLLER
DIMENSIONS
Specifi cations
Unit (mm)
ENG
English 21
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic
accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste
at the end of their working life. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local
government office, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Correct disposal of batteries in this product
(Applicable in the European Union and other European countries with separate battery return systems.)
This marking on the battery, manual or packaging indicates that the batteries in this product should not
be disposed of with other household waste at the end of their working life. Where marked, the chemical
symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference
levels in EC Directive 2006/66. If batteries are not properly disposed of, these substances can cause harm
to human health or the environment.
To protect natural resources and to promote material reuse, please separate batteries from other types of
waste and recycle them through your local, free battery return system.
AB68-00857A
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.