Each of trademarks herein is registered. The name of this product and other trademarks mentioned in this manual are the registered trademark of their
respective company.
Restriction
Copyright of this document is reserved. Under no circumstances, this document shall be reproduced, distributed or changed, partially or wholly, without
formal authorization.
Disclaimer
Hanwha Techwin
provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility.
right to change the contents of this document without prior notice.
Design and specications are subject to change without prior notice.
The initial administrator ID is “admin” and the password should be set when logging in for the rst time.
Please change your password every three months to safely protect personal information and to prevent the damage of the information
theft.
Please, take note that it’s a user’s responsibility for the security and any other problems caused by mismanaging a password.
makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be
Co., Ltd. All r ights reser ved.
Hanwha Techwin
reserves the
overview
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/ accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer,
or sold with the apparatus. When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lighting storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus
has been damaged in any way, such as power-supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
15. This product is intended to be supplied by a Listed Power Supply Unit marked “Class 2” or “LPS” and rated
from 12 Vdc, min. current for each product.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT
TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECT THROUGH THE
VENTILATION GRILLS OR OTHER OPENNINGS ON THE EQUIPMENT.
Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases, shall be placed on the apparatus.
To prevent injury, this apparatus must be securely attached to the Wall/ceiling in accordance
with the installation instructions.
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION
: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude to constitute a risk of
electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to
the presence of important operating and maintenance (servicing) instructions in
the literature accompanying the product.
●● OVERVIEW
English _3
overview
Class construction
An apparatus with CLASS construction shall be connected to a MAINS socket outlet with a
protective earthing connection.
Battery
Batteries(battery pack or batteries installed) shall not be exposed to excessive heat such as
sunshine, fire or the like.
Disconnection Device
Disconnect the main plug from the apparatus, if it’s defected. And please call a repair man in
your location.
When used outside of the U.S., it may be used HAR code with fittings of an approved
agency is employed.
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
These servicing instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other than that contained in
the operating instructions unless you are qualified to do so.
Please use the input power with just one camera and other devices must not be connected.
The ITE is to be connected only to PoE networks without routing to the outside plant.
Please read the following recommended safety precautions carefully.
yDo not place this apparatus on an uneven surface.
yDo not install on a surface where it is exposed to direct sunlight, near heating equipment or
heavy cold area.
yDo not place this apparatus near conductive material.
yDo not attempt to service this apparatus yourself.
yDo not place a glass of water on the product.
yDo not install near any magnetic sources.
yDo not block any ventilation openings.
yDo not place heavy items on the product.
yPlease wear protective gloves when installing/removing the camera.
The high temperature of the product surface may cause a burn.
User’s Manual is a guidance book for how to use the products.
The meaning of the symbols are shown below.
yReference : In case of providing information for helping of product’s usages
yNotice : If there’s any possibility to occur any damages for the goods and human caused by
not following the instruction
Please read this manual for the safety before using of goods and keep it in the safe place.
4_ overview
CONTENTS
overview
installation & connection
network connection and
3
13
setup
23
3 Important Safety Instructions
6 Product Features
6 Recommended PC Specifications
6 Recommended Micro SD/SDHC/SDXC
Memory Card Specifications
6 NAS recommended specs
7 What’s Included
8 At a Glance (QND-7010R/7020R/7030R)
10 At a Glance (QNO-7010R/7020R/7030R)
11 At a Glance (QNV-7020R/7030R)
19 Memory Card Information (Not Included)
20 Connecting with other Device
23 Connecting the Camera Directly to Local
Area Networking
23Connecting the Camera Directly to a DHCP
Based DSL/Cable Modem
24Connecting the Camera Directly to a
PPPoE Modem
24Connecting the Camera to a Broadband
Router with the PPPoE/Cable Modem
25 Buttons used in IP Installer
25 Static IP Setup
27 Dynamic IP Setup
27 Port Range Forward (Port Mapping) Setup
28 Connecting to the Camera from a Shared
Local PC
28Connecting to the Camera from a Remote
PC via the Internet
web viewer
29
setup screen
39
appendix
60
29 Connecting to the Camera
30 Password setting
30 Login
30 Plug-in support specifications for each
browser
31 Installing WebViewer Plugin
31 Using a Plug-in Free Webviewer
31 Using the Live Screen (Plug-in Free
Webviewer)
32 Using the Live Screen (Plug-in Webviewer)
34 Playing the recorded video (Plug-in Free
Webviewer)
36Playing the recorded video (Plug-in
Webviewer)
39 Setup
39 Basic Setup
43 Audio & Video setup
48 Network Setup
51 Event Setup
53 NAS (Network Attached Storage) guide
58 System Setup
The dustproof and waterproof design makes you feel at ease when installing the product outdoors or exposing
it to rain.
• IR mode
If the IR indicator turns on, the product switches to the IR mode for preventing an object from being too bright,
which helps you identify the object in near distance.
• Supports 4 megapixel resolution videos
• Multi-Streaming
This network camera can display videos in different resolutions and qualities simultaneously using different
CODECs.
• Web Browser-based Monitoring
Using the Internet web browser to display the image in a local network environment.
• Alarm
When an event occurs, video is either sent to the email address registered by the user, sent to the FTP server,
saved in a Micro SD card or NAS, or a signal is sent to the alert output terminal.
• Tampering Detection
Detects tempering attempts on video monitoring.
• Defocus detection function
Detects the defocus phenomenon of the camera lens.
• Motion Detection
Detects motion from the camera’s video input.
• Auto Detection of Disconnected Network
Detects network disconnection before triggering an event.
• ONVIF Compliance
This product supports ONVIF Profile S&G.
For more information, refer to www.onvif.org.
RECOMMENDED PC SPECIFICATIONS
• CPU : Intel(R) Core(TM) i7 3.4 GHz or higher
• Supported OS : Windows 7, 8.1, 10, Mac OS X 10.9, 10.10, 10.11
• Plug-in free web viewer
Supported web browsers : Google Chrome 47, MS Edge 20
• Plug-in Webviewer
Supported web browsers : MS Explorer 11, Mozilla Firefox 43, Apple Safari 9 ※ Mac OS X only
• VGA : PCIe 256MB GDDR3 video graphics card or higher
• For your camera, we recommend you use a memory card from the following manufacturers:
Micro SD/SDHC/SDXC Memory Card : Sandisk, Transcend
NAS RECOMMENDED SPECS
• Recommended capacity : 200GB or higher is recommended.
• Simultaneous access : One unit of NAS can accept a maximum of sixteen camera accesses.
• For this camera, you are recommended to use a NAS with the following manufacturer’s specs.
Recommended products Available sizes
Netgear NAS A maximum of 16 cameras can access simultaneously.
Synology NAS A maximum of 16 cameras can access simultaneously.
When you use Netgear’s NAS equipment, do not allocate the capacity for use.
`
J
If you use NAS equipment for purposes other than video saving, the number of accessible cameras may be reduced.
`
6_ overview
WHAT’S INCLUDED
NETWORK
ACT LINK
RESET
Please check if your camera and accessories are all included in the product package.
(As for each sales country, accessories are not the same.)
AppearanceItem NameQuantityDescriptionModel Name
1
Camera
Instruction book,
Installer S/W CD
Quick Guide
(Optional)
Warranty card
(Optional)
Template
Power Terminal Block
1
1
1
1
1
1
1
Product installation guide
Plugged in the power plug
QND-7010R/7020R
/7030R
QNO-7010R/7020R
/7030R
QNV-7020R/7030R
QND-7010R/7020R
/7030R,
QNO-7010R/7020R
/7030R,
QNV-7020R/7030R
QND-7010R/7020R
/7030R,
QNO-7010R/7020R
/7030R,
QNV-7020R/7030R
QND-7010R/7020R
/7030R,
QNO-7010R/7020R
/7030R,
QNV-7020R/7030R
QND-7010R/7020R
/7030R,
QNO-7010R/7020R
/7030R,
QNV-7020R/7030R
QND-7010R/7020R
/7030R,
QNV-7020R/7030R
AppearanceItem NameQuantityDescriptionModel Name
Machine Screws
L Wrench
Used for assembling the dome case
when installing the product on the pipe,
2
wall mount, etc. or blocking a hole.
Used to control the direction of the
camera / Used to remove and replace
1
the dome cover
QND-7010R/7020R
/7030R,
QNV-7020R/7030R
QNO-7010R/7020R
/7030R,
QNV-7020R /7030R
QND-7010R/7020R
2
Tapping Screw
Used for installation on the wall or
ceiling
3
Alarm cable
RJ45 waterproof accessory
Sunshield
Sunshield Hold
1
Used when connecting to an alarm
1
Used to install in humid places
It protects the camera from the direct
1
1
It fixes the sunshield with the camera.
sunlight.
3
Card-type moisture absorbent
Attached when installed.
1
CAUTION: Be ware of the
Rated Voltage and Polarity
of the power connection.
Power Cable
1
Used to plug into the power portQNV-7020R/7030R
/7030R,
QNV-7020R/7030R
QNO-7010R/7020R
/7030R
QND-7010R/7020R
/7030R
QNO-7010R/7020R
/7030R
QNO-7010R/7020R
/7030R
QNO-7010R/7020R
/7030R
QNO-7010R/7020R
/7030R
QNV-7020R/7030R
●● OVERVIEW
English _7
overview
NETWORK
ACT LINK
RESET
AppearanceItem NameQuantityDescriptionModel Name
Audio/alarm cable
Cable bush
Plastic Anchor
Options (not included)
Pole mount bracketCylindrical pole mounting bracket
Used to connect with the audio and
1
Used to connect the LAN cable with a
1
For fixing a screw, Inserted in a hole
2
alarm port
diameter of Ø7~8.5.
(reinforced anchoring force)
QNV-7020R/7030R
QNV-7020R/7030R
QNV-7020R/7030R
QNO-7010R/7020R
/7030R
AT A GLANCE (QND-7010R/7020R/7030R)
Appearance
ItemDescription
Dome cover
a
Camera Case
b
Microphone hole
c
Case cover used to protect the lens and the main unit.
Housing part that covers the camera body.
Microphone is embedded.
a
b
c
8_ overview
Components
ItemDescription
cdba
ACT LINK
NETWORK
RESET
e
3. 4. GND
1. ALM IN
DC12V
FRONT
2. ALM OUT
f
g
h
FRONT
ACT LINK
NETWORK
DC 12V
Inside coverProtective cover for the main body.
a
Illumination SensorDetects incoming light to control the IR LED.
b
LensLens for the camera.
c
IR LEDThese infrared LED’s are controlled by the illumination sensor.
d
The button restores all camera settings to the factory default.
Press and hold for about 5 seconds to reboot the system.
If you reset the camera, the network settings will be adjusted so that DHCP can be
Reset Button
e
Alarm I/O Port
f
Microphone holeMicrophone is embedded.
g
Power PortPort for power terminal block.
h
Micro SD Memory Card
i
Compartment
Network PortUsed to connect the PoE or Ethernet cable for network connection.
j
J
enabled. If there is no DHCP server in the network, you must run the IP Installer
program to change the basic network settings such as IP address, Subnet mask,
Gateway, etc., before you can connect to the network.
ARM-INUsed to connect the alarm input sensor or external day/night sensor.
ARM-OUTUsed to connect the alarm output signal.
GNDThese are common ports to connect alarm input/output signals.
Compartment for the Micro SD memory card.
●● OVERVIEW
ji
English _9
overview
RESET
AT A GLANCE (QNO-7010R/7020R/7030R)
Appearance
bca
ItemDescription
Micro SD card slot
a
Reset Button
b
Sunshield Hold
c
(Internal space of the product) This is a slot in which you can insert a Micro SD card.
The button restores all camera settings to the factory default.
Press and hold for about 5 seconds to reboot the system.
If you reset the camera, the network settings will be adjusted so that DHCP can be
J
enabled. If there is no DHCP server in the network, you must run the IP Installer
program to change the basic network settings such as IP address, Subnet mask,
Gateway, etc., before you can connect to the network.
It fixes the sunshield with the camera.
d
Components
a
CAUTION:Be ware of the
Rated Voltage and Polarity
of the power connection.
b
c
d
ItemDescription
Power PortUsed to plug the power cable.
a
ARM-OUTUsed to connect the alarm output signal.
Alarm I/O Port
b
Network PortUsed to connect the PoE or Ethernet cable for network connection.
c
Audio In JackUsed to connect to a microphone.
d
GNDThese are common ports to connect alarm input/output signals.
ARM-INUsed to connect the alarm input sensor or external day/night sensor.
d
10_ overview
Sunshield
Wipe out a dirty surface of the lens softly with a lens tissue or cloth to which you have applied ethanol.
`
M
It protects the camera from the direct sunlight.
AT A GLANCE (QNV-7020R/7030R)
Components
Appearance
Dome cover
a
Camera Case
b
ItemDescription
Case cover used to protect the lens and the main unit.
Housing part that covers the camera body.
a
b
RESET
gh
NETWORK
ACT LINK
bca
●● OVERVIEW
DC12V
RESET
1.ALM IN
2.ALM OUT
3.4. GND
5. AUDIO IN
f
e
d
English _11
overview
Illumination SensorDetects incoming light to control the IR LED.
a
LensLens for the camera.
b
IR LEDThese infrared LED’s are controlled by the illumination sensor.
c
Power PortPort for power terminal block.
d
Audio and alarm cable port
e
Reset Button
f
Micro SD Memory Card
g
Compartment
Network PortUsed to connect the PoE or Ethernet cable for network connection.
h
ItemDescription
Terminal to which the audio and alarm cable is connected in order to connect with an
external alarm device/microphone.
The button restores all camera settings to the factory default.
Press and hold for about 5 seconds to reboot the system.
If you reset the camera, the network settings will be adjusted so that DHCP can be
J
enabled. If there is no DHCP server in the network, you must run the IP Installer
program to change the basic network settings such as IP address, Subnet mask,
Gateway, etc., before you can connect to the network.
Compartment for the Micro SD memory card.
12_ overview
installation & connection
NETWORKACT LINK
FRONT
2.ALM OUT
1. ALM IN
DC12V
INSTALLATION (QND-7010R/7020R/7030R)
Precautions before installation
Ensure you read out the following instructions before installing the camera:
• It must be installed on the area (ceiling or wall) that can withstand 5 times the weight of the camera
including the installation bracket.
• Stuck-in or peeled-off cables can cause damage to the product or a fire.
• For safety purposes, keep anyone else away from the installation site.
And put aside personal belongings from the site, just in case.
Disassembling
1. Use one hand to hold the camera’s bottom part and turn the cover
counterclockwise with another hand to separate it.
2. Lift up the inner cover to separate it.
ACT LINK
NETWORK
DC12V
ACT LINK
NETWORK
DC12V
Dome Cover
FRONT
FRONT
Installation
1. Attach the installation template to the selected area and punch 3
holes as shown in the figure.
●● INSTALLATION & CONNECTION
2. Using 2 tapping screws provided, fix the camera at 2 holes drilled
with a template.
Set the < > mark imprinted on the camera to face the direction of camera
`
monitoring.
3. Connect the camera internal terminal with the corresponding
cable.
4. Adjust the lens in a desired direction by referring to the “Adjusting
the monitoring direction for the camera” section. (page 17)
We recommend you not to touch the lens as the camera lens has been
`
J
properly focused in the final process of manufacturing. If so, the lens may be
RESET
3. 4. GND
5. AUDIOIN
1. ALM IN
2. ALM OUT
out of focus or stained by alien substances.
5. Please connect the inner cover to the main body.
6. While grabbing the bottom side of the camera with your hand, please
grab and push its cover with the other hand to align the two arrow signs,
as shown in the figure.
To assemble the dome cover, make the arrows match each other and press the
`
J
cover firmly.
If the dome cover is rotated during assembly or is assembled incorrectly, diffused
reflection may occur or the lens section may rotate, which will cause the shooting
RESET
3. 4. GND
1. ALM IN
2. ALM OUT
range to be changed.
Make sure that the dome cover is correctly connected to the bottom part as shown
`
in the figure.
If the snap-fit is not connected correctly, the dome cover may fall, which may cause
injury.
2. ALM OUT
1. ALM IN
3. 4. GND
RESET
2. ALM OUT
1. ALM IN
5. AUDIOIN
3. 4. GND
RESET
DC12V
FRONT
NETWORK
ACT LINK
DC12V
FRONT
NETWORK
ACT LINK
English _13
installation & connection
INSTALLATION (QNO-7010R/7020R/7030R)
This camera is waterproof and in compliance with the IP66 spec, but the jack connected to the external cable is not. You are
`
J
recommended to install this product below the edge of eaves to prevent the cable from being externally exposed.
Precautions before installation
Ensure you read out the following instructions before installing the camera:
• It must be installed on the area (ceiling or wall) that can withstand 5 times the weight of the camera
including the installation bracket.
• Stuck-in or peeled-off cables can cause damage to the product or a fire.
• For safety purposes, keep anyone else away from the installation site.
And put aside personal belongings from the site, just in case.
Installation
1. Attach the installation template at a desired location and make 3
holes the same size as shown in the picture below.
2. Insert and fasten 3 tapping screws provided into 3 holes to secure
the camera.
3. Connect the appropriate cables with camera terminals.
4. Adjust the camera direction using the L wrench provided.
When you adjust the camera position using a bracket, please loosen the
`
J
bracket screw, adjust the camera, and tighten it. If you attempt to adjust it
forcibly while the screw is tight, it may result in a scratch or other problems.
Mounting Template
Cable Line
How to connect the RJ45 waterproof cable to a LAN cable
1. Insert it through the arrow direction.
2. Connect the LAN connector (male) to the cable.
3. Connect the RJ45 modular jack (female) to the RJ45 connector
(male).
Please, keep each of the parts separated.
`
J
4. Assemble by rotating the RJ45 modular jack (female) and the RJ45
protection cover clockwise (Follow the arrow).
5. Assemble by rotating RJ45 protection cover and back cover
clockwise (Follow the arrow).
When the back cover is assembled, the cable waterproof gasket is
tightly attached to the cable to make it waterproof.
You must fully assemble it to rotate the back cover up to the end of the screw
`
J
thread of the RJ45 connector.
RJ45 modular
jack (female)
RJ45 connector
(male)
Rubber ring
RJ45 connector
protection cover
Back cover
Rubber ring
Cable waterproof
gasket
14_ installation & connection
Outdoor installation
When you install it outside of the building, please waterproof it with waterproof butyl rubber tape (can be
purchased in stores) so that water does not leak from the gap of the cable connected to the outside.
1. Connect the power, I/O, AUDIO, and LAN cables.
Camera
2. Wrap the black cable jacket (Area A) and the cable connection
area with waterproof (butyl rubber) tape so that more than half of
the butyl rubber tape is overlapped.
If the cable jacket is not waterproofed properly, then it can directly cause
`
J
leakage. Make sure to protect the cable with a dense layer of taping.
Waterproof butyl tape is made of butyl rubber that can be stretched to twice its normal length.
`
Camera
Camera
INSTALLATION (QNV-7020R/7030R)
This camera is waterproof and in compliance with the IP66 spec, but the jack connected to the external cable is not. You are
`
J
recommended to install this product below the edge of eaves to prevent the cable from being externally exposed.
Precautions before installation
Ensure you read out the following instructions before installing the camera:
• It must be installed on the area (ceiling or wall) that can withstand 5 times the weight of the camera
including the installation bracket.
• Stuck-in or peeled-off cables can cause damage to the product or a fire.
• For safety purposes, keep anyone else away from the installation site.
And put aside personal belongings from the site, just in case.
Disassembling
1. Using the L wrench provided, turn the 2 fastening bolts
on the dome cover counter clockwise to remove the
cover.
Dome cover
Installation
1. Using the template provided as an accessory, drill the screw
installation hole(diameter of 6mm, minimal depth of 55mm) and
System
System
AA
System
firmly insert the plastic anchor provided as an accessory to the
end.
2. Fit the bottom hole to the anchor hole and insert and fix the taping
screw (M4.5xL50).
3. Connect and arrange the necessary cables lest that they should
be damaged or twisted while installing the camera.
4. Adjust the lens in a desired direction by referring to the “Adjusting
5. AUDIO IN
3.4. GND
2.ALM OUT
1.ALM IN
RESET
●● INSTALLATION & CONNECTION
the monitoring direction for the camera” section. (page 17)
5. Close the dome cover.
`Securely fasten the fastening bolt using an L wrench to prevent water from leaking.
Connecting the LAN cable
1. Remove the dome cover and the case.
2. Pull out the long projected part of the rubber plug on the bottom and
remove it as shown in the figure.
Use an appropriate cable bush for the LAN cable to be connected.
`
J
- Basic camera : Use the cable with a diameter of Ø5~6.5.
- Components provided : Use the cable with a diameter of Ø7~8.5.
3. Insert the LAN cable into the large hole made by removing the projected
part of the rubber plug in step 2 above.
4. Remove the sheath with a cable cutter, and align the cables.
5. Connect the LAN cable with a LAN connector, and insert it into the LAN
tool.
6. Connect the finished cable to the Ethernet port.
RESET
RESET
NETWORK
ACT LINK
NETWORK
ACT LINK
Bolts
Camera Body
Camera Case
RESET
1.ALM IN
2.ALM OUT
3.4. GND
5. AUDIO IN
English _15
installation & connection
Connecting the audio/alarm cable and power cable
1. Remove the dome cover and the case.
2. Pull out the rubber plug on the bottom as shown in the figure.
3. Insert the alarm/audio cable through the hole created by removing the
rubber cap in No. 2, and connect the cable to the alarm terminal.
4. Align the cable so that it should not be damaged or jammed when
installing the camera.
5. Put the rubber cap located on the alarm/audio cable in the hole.
6. Insert the power cable into the small-sized hole through the long, carved
groove.
7. Connect the power cable to the power terminal block.
8. Adjust the lens in a desired direction by referring to the “Adjusting the
monitoring direction for the camera” section.
9. Attach the dome cover.
(page 17)
Attaching to the unbundled adapter
Choose and purchase a necessary one of the following options (unbundled) that is suitable to the installation
site or for your convenience.
1. Remove the dome cover from the case by referring to the “Disassembling” section. (page
15
)
2. Use the provided machine screw to fix the camera case to the unbundled adapter.
3. Connect and arrange the necessary cables lest that they should be damaged or twisted while installing the
NETWORK
RESET
ACT LINK
camera.
4. Install the camera body in the reverse order of “Disassembling”.
5. Adjust the lens in a desired direction by referring to the “Adjusting the monitoring direction for the
17
camera” section. (page
)
6. Close the dome cover.
`Securely fasten the fastening bolt using an L wrench to prevent water from leaking.
Outdoor installation
When you install it outside of the building, please waterproof it with waterproof butyl rubber tape (can be
purchased in stores) so that water does not leak from the gap of the cable connected to the outside.
NETWORK
RESET
RESET
ACT LINK
NETWORK
ACT LINK
1. Connect the power, I/O, BNC, and LAN cables.
2. Wrap the black cable jacket (Area A) and the cable connection area
with waterproof (butyl rubber) tape so that more than half of the
butyl rubber tape is overlapped.
If the cable jacket is not waterproofed properly, then it can directly cause
`
J
leakage. Make sure to protect the cable with a dense layer of taping.
Waterproof butyl tape is made of butyl rubber that can be stretched to twice
`
its normal length.
Camera
Camera
Camera
System
System
AA
System
16_ installation & connection
CAUTION: Be ware of th e
Rated Voltage and Polar ity
of the power con necti on.
Optional Accessories for Installation
For your easier installation, you can purchase appropriate optional accessories available.
1. WALL MOUNT ADAPTOR(SBP-300WM or SBP-300WM1)/
HANGING MOUNT(QND-7010R/7020R/7030R : SBP-300HM8)
This adaptor is used when installing the dome camera onto a
wall.
2. CEILING MOUNT ADAPTOR(SBP-300CM)/HANGING MOUNT(QND7010R/7020R/7030R : SBP-300HM8)
This adaptor is used when installing the dome camera on a concrete
ceiling.
3. POLE MOUNT ADAPTOR(SBP-300PM)
This is an adaptor for WALL MOUNT ADAPTOR (SBP-300WM or SBP300WM1) installation on a pole whose diameter is bigger than 80mm.
Adjusting the monitoring direction for the camera (QND-7010R/7020R/7030R,
QNV-7020R/7030R)
Pan
5. AUDIO IN
3.4. GND
2.ALM OUT
1.ALM IN
RESET
Tilt
Lens rotation
`Adjusting the monitoring direction
You can adjust the camera direction only when the camera is fixed on the ceiling.
Where, rotating the camera unit to the left or right is called Pan, adjusting the tilt is called Tilt, and turning the
lens on its axis is called Rotation.
- The effective range of pan is a total of 350 degrees.
- The effective range of rotation is a total of 355 degrees.
- The effective range of tilt is a total of 67 degrees.
The image can be covered up by the camera case depending on the angle.
`
J
Do not forcefully turn the focus/zoom lens after the dome case is disassembled.
`
Otherwise, it may cause an incorrect focus due to a motor failure.
`Methods of adjustment
1. After installing the camera, adjust the panning angle in consideration of the monitoring direction.
2. Set the horizontal angle so that the image is not reversed.
3. Adjust the tilt angle so that the camera faces toward the monitoring object.
●● INSTALLATION & CONNECTION
4. CORNER MOUNT ADAPTOR (SBP-300KM)
This is an adaptor for WALL MOUNT ADAPTOR (SBP-300WM or
SBP-300WM1) installation on the corner of wall joint.
English _17
installation & connection
RESET
NETWORK
ACTLINK
NETWORK
ACT LINK
DC 12V
FRONT
INSERTING/REMOVING A MICRO SD MEMORY CARD
Disconnect the power cable from the camera before inserting the Micro SD memory card.
`
J
Do not insert the Micro SD memory card while it’s upside down by force.
`
Otherwise, it may damage the Micro SD memory card.
When it rains or the humidity is high, insertion or ejection of a Micro SD card is not recommended.
`
Disassembly of the product cover should be finished within 5 minutes, or there will be the risk of internal dew condensation.
`
Inserting a Micro SD Memory Card (QNO-7010R/7020R/7030R)
1. Turn the front cover to the UNLOCK [ ] direction.
2. Pull and separate the front cover.
3. Insert a Micro SD card in the arrow direction shown in the figure.
Inserting a Micro SD Memory Card (QND-7010R/7020R/7030R, QNV-7020R/7030R)
1. Separate the Dome cover of the camera.
2. Insert a Micro SD card in the arrow direction shown in the figure.
FRONT
ACT LINK
DC 12V
NETWORK
ACT LINK
NETWORK
<QND-7010R/7020R/7030R>
RESET
RESET
18_ installation & connection
<QNV-7020R/7030R>
Removing a Micro SD Memory Card
NETWORK
ACTLINK
NETWORK
ACT LINK
DC 12V
FRONT
RESET
Gently press down on the exposed end of the memory card as shown in the diagram to eject the memory
card from the slot.
Pressing too hard on the Micro SD memory card can cause the card to shoot out uncontrollably from the slot when released.
`
J
Before removing your Micro SD memory card, turn off the camera or go to <Storage>, turn the device off, and press the [Apply
`
(
)] button. (Page 52)
If you turn off the camera or remove the Micro SD memory card that contains data from the product, the data may be lost or
`
damaged.
MEMORY CARD INFORMATION (NOT INCLUDED)
●● INSTALLATION & CONNECTION
ACT LINK
<QND-7010R/7020R/7030R>
RESET
<QNO-7010R/7020R/7030R>
RESET
FRONT
NETWORK
DC 12V
The memory card is an external data storage device that has been developed to offer an entirely new way to
record and share video, audio, and text data using digital devices.
Selecting a memory card that’s suitable for you
Your camera supports Micro SD/SDHC/SDXC memory cards.
You may, however, experience compatibility issues depending on the model and make of the memory card.
For your camera, we recommend you use a memory card from the following manufacturers:
Micro SD/SDHC/SDXC Memory Card : Sandisk, Transcend
It is recommended to use a 4 to 128GB (uhs-1 class) memory card for this camera.
Playback performance can be affected depending on the speed of memory card, so use the high-speed
memory card.
Memory Card Components
Contacts
Micro SD/SDHC/SDXC
NETWORK
ACT LINK
What is a memory card?
<QNV-7020R/7030R>
English _19
installation & connection
NETWORK
ACTLINK
CONNECTING WITH OTHER DEVICE
ACT LINK
NETWORK
Ethernet
Power
Ethernet
DC12V
FRONT
<QND-7010R/7020R/7030R>
CAUTION:Be ware of the
Rated Voltage and Polarity
of the power connection.
1. ALM IN
2. ALM OUT
Power
Ethernet Connection
Connect the Ethernet cable to the local network or to the Internet.
Power Supply
Use the screwdriver to connect each line (+, –) of the power cable to the corresponding power port of the
camera.
If both PoE and DC 12V are applied simultaneously, the product will be supplied with power from PoE.
`
RESET
3. 4. GND
Power
J
- You can also use a router featuring PoE to supply power to the camera.
- Use PoE that is compliant with the IEEE 802.3af protocols.
- It is advisable to use only one power source from PoE and DC 12V.
Be careful not to reverse the polarity when you connect the power cable.
`
If you want to connect an external device, you must turn off the external device before proceeding.
`
Power Cable Specification for Each Model
In case of DC 12V Input:
Wire Type (AWG)#22#20#18
Cable Length (Max.)24m38m60m
Network Cable Specification
NETWORK
RESET
Ethernet
of the power c onnect ion.
CAUTION: Be wa re of the
Rated Voltage a nd Pol arity
ACT LINK
ItemContentsRemark
ConnectorRJ45
Ethernet10/100BASE-T10/100 Mbps
CableUTP Category 5e
Max Distance100M
PoE SupportIEEE 802.3af
20_ installation & connection
<QNO-7010R/7020R/7030R>
<QNV-7020R/7030R>
Connecting to Audio Input
Connecting to the I/O port box
Connect the Alarm I/O cable to the corresponding port of the port box.
Speaker
Microphone
PC
Network
Microphone
Amp
Microphone
Amp
Microphone
Microphone
1. Connect the AUDIO IN port of the camera with the microphone or LINE OUT port of the amplifier that the
microphone is connected to.
You can use the built-in microphone in the camera without connecting an external microphone.
• Audio in (QNO-7010R/7020R/7030R, QNV-7020R/7030R) : Selectable (microphone/Line-in), Supported
voltage: 2.5VDC (4mA), Input impedance: 2K Ohm
(Warning lamp)
<QND-7010R/7020R/7030R>
SensorAlarm
<QNO-7010R/7020R/7030R>
CAUTION:Be ware of the
Rated Voltage and Polarity
of the power connection.
●● INSTALLATION & CONNECTION
SensorAlarm
(Warning lamp)
English _21
installation & connection
RESET
1.ALM IN
2.ALM OUT
3.4. GND
5. AUDIO IN
SensorAlarm
(Warning lamp)
<QNV-7020R/7030R>
• ALARM-IN : Used to connect the alarm input sensor or external day/night sensor.
• ALARM-OUT : Used to connect the alarm output signal.
• GND : Common port for alarm in/output signal.
If devices (e.g., flashing light and siren) that exceed the voltage and current specifications are connected by using the open
`
J
collector method, it may cause malfunction.
Refer to the “Alarm Out Wiring Diagram” when connecting devices that exceed the voltage and current specifications. (page
22)
To connect the external sensor
Connect one strand of each signal line (2-strand) of the sensors to the [ALARM IN] port, and connect the
other strand to the [GND] port.
Alarm In Wiring Diagram
External
connection
Sensor
Inside of the camera
GND
VCC_3.3V
RESISTORRESISTOR
RESISTORALARM IN (5mA SINK)
TRANSISTOR
MLCC
GND
DIODE
To connect the alarm out
If devices (e.g., flashing light and siren) that exceed the voltage and current specifications are connected by
using the open collector method, it may cause malfunction.
Refer to the alarm out connection diagram below when connecting devices that exceed the voltage and
current specifications.
Alarm Out Wiring Diagram
Warning lamp /
Siren power
(-)(+)
Warning lamp /
Siren
External connectionInside of the camera
DC 5V or 3.3V
DIODE
RELAY
RESISTOR10K ohm
TRANSISTOR
GND
ALARM OUT (12VDC 20mA MAX)
RESISTOR
TRANSISTOR
GND
GND
22_ installation & connection
network connection and setup
You can set up the network settings according to your network configurations.
CONNECTING THE CAMERA DIRECTLY TO LOCAL AREA NETWORKING
Connecting to the camera from a local PC in the LAN
1. Launch an Internet browser on the local PC.
2. Enter the IP address of the camera in the address bar of the browser.
Camera
INTERNET
Camera
Local PC
<Local Network>
A remote PC in an external Internet out of the LAN network may not be able to connect to the camera installed in the intranet
`
M
if the port-forwarding is not properly set or a firewall is set.
In this case, to resolve the problem, contact your network administrator.
In the IP installer, you can use the initial password, “4321” to set IP Address, Subnet Mask, Gateway, HTTP Port, VNP Port, IP
`
type. After changing the network interface, for better security, access the web viewer and change the password.
By factory default, the IP address will be assigned from the DHCP server automatically.
`
If there is no DHCP server available, the IP address will be set to 192.168.1.100.
To change the IP address, use the IP Installer.
For further details on IP Installer use, refer to “Static IP Setup”. (Page 25)
External Remote PC
DDNS Server
(Data Center, KOREA)
CONNECTING THE CAMERA DIRECTLY TO A DHCP BASED DSL/CABLE
MODEM
DSL/Cable Modem
Camera
1. Connect the user PC directly with the network camera.
2. Run the IP Installer and change the IP address of the camera so that you can use the web browser on
your desktop to connect to the Internet.
3. Use the Internet browser to connect to the web viewer.
4. Move to [Setup] page.
5. Move to [Network] – [DDNS] and configure the DDNS settings.
6. Move to [Basic] – [IP & Port], and set the IP type to [DHCP].
7. Connect the camera, which was removed from your PC, directly to the modem.
8. Restart the camera.
For configuring the DDNS settings, refer to “DDNS”. (page 48)
`
M
For registering the DDNS settings, refer to “Registering with DDNS”. (page 48)
`
Refer to “IP & Port” for how to setup IP. (page 42)
`
INTERNET
DDNS Server
(Data Center, KOREA)
External Remote PC
●● NETWORK CONNECTION AND SETUP