Samsung NK36R5000WS-AA, NK30R5000WS, NK30R5000WG-AA, NK36R5000WS, NK36R5000WG User Manual

...
Range Hood Hotte de la cuisine Campana de cocina
Installation Instructions Guide Guide d’instructions d’installation Guía de Instrucciones para Instalación
NK36R5000WG/AA, NK30R5000WG/AA, NK36R5000WS/AA, NK30R5000WS/AA
Table of Contents
Important Safety Instructions 3
Installation Requirements 4
Electrical Requirements 4
Before Installing the Hood 4
Venting Methods 4
Tools and Parts 5
Dimensions and Clearances 5
Installation 6
Installation Instructions 6
Install the Range Hood 7
Table of Contents
Install Duct Covers 8
Electrical Connection 8
Range Hood Use and Care 9
Description of the Hood 9
Control 9
Maintenance 9
Accesories 10
Range Hood for ADA Compliance 11
Warranty (USA) 12
Warranty (Canada) 13
2 English
Important Safety Instructions
APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTALLATION GUIDE BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical
Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for
the owner.
OWNER: Please retain these instructions for future reference.
Symbols used in this manual
WARNING
Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that may result in electric shock, personal injury, or property damage.
NOTE
Useful tips and instructions These warning icons and symbols are here to prevent injury to you and others. Please follow them explicitly. After reading this section, keep it in a safe place for future reference.
WARNING
Turn off the power circuit at the service panel and lock out panel before wiring this appliance.
Requirement 120 VAC, 60 Hz. 15 or 20 A Branch Circuit
WARNING
Cancer and Reproductive Harm - www.P65Warnings.ca.gov
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING PRECAUTIONS:
■ Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer.
■ Before servicing or cleaning the unit, switch the power off at the service panel and lock the service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and standards,
including re-rated construction.
■ Sufcient air is needed for proper combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
■ When cutting or drilling into the wall or ceiling; do not damage
electrical wiring and other hidden utilities.
■ Ducted fans must always be vented to the outdoors.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
CAUTION
To reduce the risk of re and to properly exhaust air, be sure to duct air
outside - do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces or garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
■ Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
Always turn the hood ON when cooking at high heat or when ambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
■ Clean ventilating fans frequently. Grease should not be allowed to
accumulate on the fan or lter.
■ Use proper pan sizes. Always use cookware appropriate for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING PRECAUTIONS:
a
SMOTHER FLAMES with a close tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
■ NEVER PICK UP A FLAMING PAN - you may be burned.
■ DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result
■ Use an extinguisher ONLY if:
- You know you have a class ABC extinguisher, and you already know
how to operate it.
– The re is small and contained in the area where it started. – The re department is being called. – You can ght the re with your back to an exit.
a
Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
To reduce the risk of re or electrical shock, do not use this fan with any
solid-state speed control device.
WARNING
Do not let children near this appliance. Do not let children play with this appliance. Keep all packaging materials out of children’s reach. Properly dispose the packaging materials after this appliance is unpacked.
NOTE
Suitable for use in household cooking area.
Important Safety Instructions
Read and save this instructions
English 3
Installation Requirements
Electrical Requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a qualied electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended
that a qualied electrician determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 CSA International
Installation Requirements
8501 East Pleasant Valley Road Cleveland, OH 44131-5575
Other Requirements
■ A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
■ If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
■ Follow the electrical connector manufacturer’s recommended procedure. Aluminum/copper connections must conform with local codes and industry accepted wiring practices.
■ Wire sizes and connections must conform with the rating of the
appliance as specied on the model/serial rating plate. The model serial plate is located behind the lter on the rear wall of the range hood.
■ Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
■ A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).
Before installing the Hood
The Vent system must terminate outdoors.
For the most efcient air ow exhaust, use a straight run or as few elbows as possible. CAUTION: Vent unit to outside of building, only.
At least two people are necessary for installation.
Fittings material are provided to secure the hood to most types
walls and ceilings. Consult a qualified installer to confirm that
of
the fittings are suitable for your cabinets, walls, and ceiling.
Do not use flexible ducting.
COLD WEATHER installations should have an additional backdraft
damper installed to minimize backward cold air ow and a
nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house.
Venting Methods
Closely follow the instructions set out in this manual. Samsung is not
responsible for any eventual inconveniences, damages or res caused by
not complying with the instructions in this manual.
Ducting version The hood is equipped with a 6” (15.2 cm) round transition for discharge of
fumes to the outside.
Horizontal Discharge Vertical Discharge Horizontal Discharge
A
B
A
B
B
A. Wall cap B. 6” (15.2 cm) round vent
A. Roof cap B. 6” (15.2 cm) round vent
A. Deector
B. 6” (15.2 cm) round vent
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. Fittings material are provided to secure the hood to most types of walls/ceilings.
However, a qualified technician must verify that the fittings are suitable for your cabinets, walls, and ceiling.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for the exhaust vent.
Ductless version (Recirculating)
For installations where cooking fumes and vapor cannot be discharged to the outside, attach a charcoal filter and the deflector to the duct cover
support bracket. Fumes and vapors will be recycled through the top grille by a duct connected to the transition and the transition mounted on the
deflector.
NOTE
For horizontal discharge only: purchase the Ductless Recirculating Kit. Minimum Duct Size: 6” Round Pipe.
CAUTION
■ For electric/induction cooktop & range installations: Mount the hood so the bottom is at least 24” (61cm) above the cooking surface.
■ For gas cooktop & range installations: Mount the hood so the bottom is at least 27” (68.6 cm) above the cooking surface.
■ For both, mount no higher than 36” (91.4 cm) above the cooking
surface.
■ Measure the mounting height from the surface of the range to the bottom of the hood.
WARNING
This hood is intended for household use. PLEASE READ THE INSTALLATION MANUAL FOR THE HOOD´S SPECIFIC APPLICATION. Check your ceiling height and the hood´s height before selecting your hood.