Samsung n820, S820, n850 Reference Information

5 Schematic Diagrams and PCB Silkscreen
5-27S820/S850
5-1-2 Signal Location
Signal Name Sheet Number - Location
AD_SEL 16-B2, 17-B4, 23-B1, 26-D3 ADAPTOR_IN 17-B3, 26-C3 ADAPTOR_IN* 15-C3, 16-B1, 25-A1 AGP3_BUSY* 6-A4, 18-B2, 19-A2, 25-A3 AGP3_GAD(0:31) 3-A4, 18-D2, 25-C4 AGP3_GADSTBA 3-A2, 18-B2, 19-A2, 25-C3 AGP3_GADSTBB 3-A2, 18-B2, 19-A2, 25-C3 AGP3_GCBE*(0:3) 3-A3, 18-C2, 25-A4 AGP3_GDEVSEL* 3-A3, 18-B2, 19-A3, 25-C3 AGP3_GFRAME* 3-A3, 18-B2, 19-A3, 25-C3 AGP3_GGNT* 3-A2, 18-B2, 19-A3, 25-C3 AGP3_GIRDY* 3-A3, 18-B2, 19-A3, 25-C3 AGP3_GPAR 3-A2, 18-B2, 19-A3, 25-C3 AGP3_GREQ* 3-A2, 6-A4, 18-B2, 19-A3,
25-C3 AGP3_GSTOP* 3-A2, 18-B2, 19-A3, 25-C3 AGP3_GTRDY* 3-A2, 18-B2, 19-A3, 25-C3 AGP3_PIPE* 3-A2, 18-B2, 19-A2, 25-C3 AGP3_RBF* 3-A2, 18-B2, 19-A2, 25-C3 AGP3_SBA(0:7) 3-A2, 18-B2, 25-C3 AGP3_SBSTB 3-A2, 18-B2, 19-A2, 25-C3 AGP3_ST(0:2) 3-A2, 18-B2, 25-C3 AUD3_GD(0:6) 20-A1, 20-C1, 22-C4, 26-C3 AUD3_PME* 8-C2, 22-C3, 25-B2 AUD5_MIC 22-A1, 22-B1, 26-B3 AUD5_SPKR 22-B1, 22-C1, 26-B3 BAT5_SMCLKLI* 16-B4, 23-B1, 26-D3 BAT5_SMDATAMH*
16-C4, 23-B2, 26-D3 BAT5_TEMP 15-C1, 23-B1, 25-A1 BAT5_VOLT 15-C2, 23-B2, 25-B1 CA12_VPP 10-B1, 10-C4, 25-A2 CB12_VPP 10-B1, 10-C3, 25-A2 CBA3_A18 9-C4, 10-C4, 25-B2 CBA3_CAD(0:31) 9-D4, 10-D4, 25-D2 CBA3_CAUDIO 9-D4, 10-B4, 10-C2, 25-B2 CBA3_CBLOCK* 9-D4, 10-C2, 10-C4, 25-B2 CBA3_CCBE0* 9-D3, 10-D4, 25-A2 CBA3_CCBE1* 9-D3, 10-C4, 25-A2 CBA3_CCBE2* 9-D3, 10-B4, 25-A2
Signal Name Sheet Number - Location
CBA3_CCBE3* 9-D3, 10-B4, 25-A2 CBA3_CCD1* 9-C4, 10-C1, 10-D4, 25-B2 CBA3_CCD2* 9-C4, 10-A4, 10-C1, 25-B2 CBA3_CCLK 9-D2, 10-C4, 25-A2 CBA3_CCLKRUN* 9-C4, 10-A4, 10-C2, 25-B2 CBA3_CDEVSEL* 9-D4, 10-C2, 10-C4, 25-B2 CBA3_CFRAME* 9-D4, 10-B4, 25-B2 CBA3_CGNT* 9-D4, 10-C4, 25-B2 CBA3_CINT* 9-D4, 10-C2, 10-C4, 25-B2 CBA3_CIRDY* 9-C4, 10-B4, 10-C2, 25-B2 CBA3_CPAR 9-C4, 10-C4, 25-B2 CBA3_CPERR* 9-C4, 10-C2, 10-C4, 25-B2 CBA3_CREQ* 9-C4, 10-B4, 10-C2, 25-B2 CBA3_CRST* 9-C4, 10-B4, 10-C2, 25-B2 CBA3_CSERR* 9-C4, 10-B4, 10-C2, 25-B2 CBA3_CSTOP* 9-C4, 10-C2, 10-C4, 25-B2 CBA3_CSTSCHG 9-C4, 10-B4, 10-C2, 25-B2 CBA3_CTRDY* 9-C4, 10-B4, 10-C2, 25-B2 CBA3_CVS1 9-C4, 10-C1, 10-C4, 25-A2 CBA3_CVS2 9-C4, 10-B4, 10-C1, 25-A2 CBA3_D14 9-C4, 10-D4, 25-B2 CBA3_D2 9-C4, 10-A4, 25-B2 CBA3_VCC 9-C4, 10-B1, 10-C2, 10-C4,
25-A2 CBB3_A18 9-C1, 10-C3, 25-D2 CBB3_CAD(0:31) 9-D1, 10-D3, 25-C2 CBB3_CAUDIO 9-D1, 10-B3, 10-D2, 25-D2 CBB3_CBLOCK* 9-D1, 10-C3, 10-D2, 25-D2 CBB3_CCBE0* 9-D2, 10-D3, 25-A2 CBB3_CCBE1* 9-D2, 10-C3, 25-A2 CBB3_CCBE2* 9-D2, 10-B3, 25-A2 CBB3_CCBE3* 9-D2, 10-B3, 25-A2 CBB3_CCD1* 9-C1, 10-C1, 10-D3, 25-D2 CBB3_CCD2* 9-C1, 10-A3, 10-C1, 25-D2 CBB3_CCLK 9-D2, 10-C3, 25-A2 CBB3_CCLKRUN* 9-C1, 10-A3, 10-D2, 25-D2 CBB3_CDEVSEL* 9-D1, 10-C3, 10-D2, 25-D2 CBB3_CFRAME* 9-C1, 10-B3, 25-D2 CBB3_CGNT* 9-C1, 10-C3, 25-D2
5 Schematic Diagrams and PCB Silkscreen
S820/S8505-28
Signal Name Sheet Number - Location
CBB3_CINT* 9-C1, 10-C3, 10-D2, 25-D2 CBB3_CIRDY* 9-C1, 10-B3, 10-D2, 25-D2 CBB3_CPAR 9-C1, 10-C3, 25-D2 CBB3_CPERR* 9-C1, 10-C3, 10-D2, 25-D2 CBB3_CREQ* 9-C1, 10-B3, 10-D2, 25-D2 CBB3_CRST* 9-C1, 10-B3, 10-D2, 25-D2 CBB3_CSERR* 9-C1, 10-B3, 10-D2, 25-D2 CBB3_CSTOP* 9-C1, 10-C3, 10-D2, 25-D2 CBB3_CSTSCHG 9-C1, 10-B3, 10-D2, 25-D2 CBB3_CTRDY* 9-C1, 10-B3, 10-D2, 25-D2 CBB3_CVS1 9-C1, 10-C1, 10-C3, 25-D2 CBB3_CVS2 9-C1, 10-B3, 10-C1, 25-D2 CBB3_D14 9-C1, 10-D3, 25-D2 CBB3_D2 9-C1, 10-A3, 25-D2 CBB3_VCC 9-C1, 10-B1, 10-C3, 10-D2,
25-D2 CBS3_PME* 8-C2, 9-A2, 25-B2 CBS3_RI* 9-A1, 16-C2, 25-C2 CBS3_SDATA 9-A1, 10-B2, 25-C2 CBS3_SLATCH 9-A1, 10-B2, 25-D2 CBS3_SPKR 9-A2, 22-C2, 25-A2 CBS3_SUSCLK 9-A1, 10-A2, 10-B2, 25-C2 CDD5_A0 7-C2, 12-C3, 25-C2 CDD5_A1 7-C2, 12-C3, 25-C2 CDD5_A2 7-C2, 12-C4, 25-C2 CDD5_COM 12-C4, 22-B2, 25-A2 CDD5_CS1* 7-C2, 12-C3, 25-C2 CDD5_CS3* 7-C2, 12-C4, 25-C2 CDD5_D(0:15) 7-D2, 12-D3, 12-D4, 25-A3 CDD5_DACK* 7-C2, 12-C4, 25-C2 CDD5_DREQ 7-C2, 12-C4, 25-C2 CDD5_IOR* 7-C2, 12-C3, 25-C2 CDD5_IORDY 7-C2, 12-C3, 25-C2 CDD5_IOW* 7-C2, 12-C3, 25-C2 CDD5_L 12-C4, 22-B2, 25-A2 CDD5_R 12-C4, 22-B2, 25-A2 CHP3_ACPIEN 7-B4, 8-B2, 25-C3 CHP3_BIOSCS* 7-B2, 11-B3, 25-C3 CHP3_BIOSWP 7-C4, 11-B4, 25-D3
Signal Name Sheet Number - Location
CHP3_CDBUFEN* 7-B4, 12-C2, 25-C3 CHP3_CDPWRON 7-B4, 12-B2, 25-C3 CHP3_CDRST* 7-B4, 12-D3, 25-C3 CHP3_CPUSTP* 2-C4, 7-B4, 25-D4 CHP3_DOCKAUD 7-C4, 22-B3, 25-D3 CHP3_FANON1* 7-B4, 8-A2, 25-C3 CHP3_HDDBUFEN* 7-B4, 12-D2, 25-C3 CHP3_HDDPWRON 7-B4, 12-A2, 25-C3 CHP3_HDDRST* 7-B4, 12-B4, 25-C3 CHP3_IVTPWRON 7-B4, 19-A2, 25-C3 CHP3_KBCCS* 7-B4, 15-C2, 25-C3 CHP3_LEGTHRM* 7-C4, 8-B2, 25-C3 CHP3_PCGNTA* 7-B4, 9-A1, 25-C3 CHP3_PCGNTB* 7-B4, 22-B4, 25-C3 CHP3_PCISTP* 2-C4, 7-B4, 25-D4 CHP3_PCREQA* 7-D4, 9-A1, 25-D3 CHP3_PCREQB* 7-D4, 22-B4, 25-C3 CHP3_PMCCS* 7-B2, 15-C2, 25-C3 CHP3_PME* 7-C4, 8-C1, 25-D3 CHP3_PORT80* 7-B2, 25-C3 CHP3_RSTDCK* 7-B4, 20-C4, 25-C3 CHP3_SERIRQ 6-C1, 7-C4, 9-A1, 20-C2,
22-B4, 24-B2, 25-A3 CHP3_SPDSELA* 5-A4, 7-B4, 25-B3 CHP3_SPDSELB* 5-A4, 7-B4, 25-B3 CHP3_SPKR 7-B4, 22-C2, 25-C3 CHP3_SUSA* 2-B3, 2-C3, 7-B2, 15-C1,
25-C4 CHP3_SUSB* 3-D3, 7-B4, 25-C3 CHP3_SUSC* 7-B4, 9-A2, 25-C3 CHP3_SUSCLK 7-B2, 10-A2, 18-C2, 25-C3 CHP3_SUSSTAT1* 3-D3, 7-B4, 18-B2, 25-C4 CHP3_SUSSTAT2* 7-B4, 20-C2, 25-C3 CHP3_SWAPIN* 7-C4, 12-C3, 25-D3 CHP3_THRM* 7-C4, 8-B1, 25-D3 CHP3_USBPWR0* 7-C4, 17-D4, 25-D3 CHP3_USBPWR1* 7-C4, 17-D4, 25-D3 CHP3_VGASUS* 7-C4, 18-C2, 25-C3 CLK2_HCLK0 2-D1, 3-B4, 25-D4
5 Schematic Diagrams and PCB Silkscreen
5-29S820/S850
Signal Name Sheet Number - Location
CLK2_HCLK1 2-D1, 3-B4, 25-D4 CLK3_48MHZ 2-C3, 6-B3, 25-D4 CLK3_DCLKRW 2-B1, 3-A4, 25-C4 CLK3_MCLK0 2-B1, 5-C4, 25-C4 CLK3_MCLK1 2-B1, 5-C3, 25-C4 CLK3_MCLK2 2-B1, 5-C2, 25-C4 CLK3_MCLK3 2-B1, 5-C1, 25-C4 CLK3_OSCIO 2-D1, 13-B4, 25-D4 CLK3_OSCPX4 2-D1, 6-B3, 25-D4 CLK3_PCLK0 2-D1, 20-A2, 25-D4 CLK3_PCLK1 2-D1, 24-B3, 25-D4 CLK3_PCLKAUD 2-D1, 22-C3, 25-D4 CLK3_PCLKBX 2-D1, 3-A4, 25-D4 CLK3_PCLKCB 2-D1, 9-A3, 25-D4 CLK3_PCLKPX4 2-C1, 6-B3, 25-D4 CPU2_A20M* 3-B4, 3-C4, 6-A4, 25-B4 CPU2_FERR* 3-B4, 6-B4, 25-C4 CPU2_IGNNE* 3-B4, 3-C4, 6-B4, 25-C4 CPU2_INIT* 3-B4, 3-C4, 6-B4, 25-B4 CPU2_INTR 3-B4, 3-C4, 6-B4, 25-B4 CPU2_NMI 3-B4, 3-C4, 6-B4, 25-B4 CPU2_SMI* 3-A4, 3-C4, 6-B4, 25-B4 CPU2_STPCLK* 3-A4, 3-C4, 6-B4, 25-B4 DCK3_PCIRST* 20-C2, 20-C4, 26-C3 DCK3_SCLK 20-C1, 22-B3, 26-C3 DCK3_SDATA_IN 20-C1, 22-B3, 26-C3 DCK3_SDATA_OUT 20-C1, 22-B3, 26-C3 DCK3_SDFS0 20-C1, 22-B3, 26-C3 DCK3_SUSCLK 10-A2, 20-C2, 25-A2 DCK5_DCKIN1* 15-C3, 20-C3, 25-A1 DCK5_EJECT 15-C3, 20-A2 DCK5_LANWAKE* 15-D3, 20-C1, 25-A1 DCK5_PME* 8-C2, 20-C2, 25-B2 DCK5_PORT* 15-C1, 20-A1, 25-A1 DCK5_SPKR 20-C2, 22-C2, 26-B3 DOCK_DC 17-B4, 20-A4, 23-B1, 23-B2,
23-C2, 26-C3
FDD5_DIR* 12-C4, 13-C3, 23-B4, 23-C4
25-B2
Signal Name Sheet Number - Location
FDD5_DS0* 12-C3, 13-C1, 13-C3, 17-B3,
23-B4, 23-C4, 25-B2 FDD5_DSKCHG* 12-C4, 13-B3, 13-C1, 23-B4,
23-C4, 25-B2 FDD5_EXTIN* 7-C4, 23-C4, 25-D3 FDD5_HDSEL* 12-C3, 13-B3, 23-B4, 23-C4,
25-B2 FDD5_INDEX* 12-C4, 13-C2, 13-C3, 23-A4,
23-C4, 25-B2 FDD5_J3MODE 12-C3, 13-C3, 23-B3, 23-C4,
25-B2 FDD5_MTR0* 12-C3, 13-C3, 23-B4, 23-C4,
25-B2 FDD5_RDATA* 12-C4, 13-B3, 13-C2, 23-B4,
23-C4, 25-B2 FDD5_STEP* 12-C3, 13-C3, 23-B4, 23-C4,
25-B2 FDD5_TRK0* 12-C4, 13-B3, 13-C2, 23-B4,
23-C4, 25-B2 FDD5_WDATA* 12-C4, 13-C3, 23-B4, 23-C4,
25-B2 FDD5_WGATE* 12-C3, 13-B3, 23-B4, 23-C4,
25-B2 FDD5_WP* 12-C3, 13-B3, 13-C2, 23-B4,
23-C4, 25-B2 FIR5_MOD 13-B3, 22-B2, 25-B2 FIR5_RXD 13-B3, 22-B2, 25-B2 FIR5_TXD 13-B3, 22-B2, 25-B2 HDD5_A0 7-D2, 12-A4, 25-D2 HDD5_A1 7-D2, 12-B4, 25-D2 HDD5_A2 7-D2, 12-A3, 25-D2 HDD5_CS1* 7-C2, 12-A4, 25-D2 HDD5_CS3* 7-C2, 12-A3, 25-D2 HDD5_D(0:15) 7-D2, 12-B3, 25-B3 HDD5_DACK* 7-C2, 12-B4, 25-D2 HDD5_DREQ 7-C2, 12-B4, 25-D2 HDD5_IOR* 7-D2, 12-B4, 25-D2 HDD5_IORDY 7-C2, 12-B4, 25-D2 HDD5_IOW* 7-D2, 12-B4, 25-D2
5 Schematic Diagrams and PCB Silkscreen
S820/S8505-30
Signal Name Sheet Number - Location
HDD5_LED* 12-C1, 17-B3, 25-A2 HDD5_QIRQ(14) 12-B4, 12-C2, 12-C3, 12-D2,
25-A2, 25-B2 HDD5_QLED* 12-A4, 12-C2, 25-A2 INT_VDC 19-A1, 19-D1, 26-D3 ISA3_AEN 6-B3, 13-D4, 25-B3 ISA3_DACK*(0:3) 7-A4, 13-C3, 13-C4, 25-D2 ISA3_DRQ(0:7) 7-A4, 7-C1, 13-B4, 13-C4,
25-D2 ISA3_IOCHK* 6-C1, 7-D4 ISA3_IOCHRDY 6-B3, 6-C1, 13-B4, 25-B3 ISA3_IOCS16* 6-B3, 6-C1, 25-B3 ISA3_IOR* 6-B3, 6-C1, 13-D4, 15-C2,
25-B3 ISA3_IOW* 6-B3, 6-C1, 13-D4, 15-C2,
25-B3 ISA3_IRQ(15) 7-B2, 7-C1, 7-C2, 7-D1,
12-C1, 12-D1, 13-B4, 13-C3,
15-C2 ISA3_MEMCS16* 6-B3, 6-C1, 25-B3 ISA3_MEMR* 6-B3, 6-C1, 11-B3, 25-B3 ISA3_MEMW* 6-B3, 6-C1, 11-B4, 25-B3 ISA3_REFRESH* 6-B3, 6-C1, 25-B3 ISA3_RSTDRV 6-B3, 13-B4, 25-B3 ISA3_SA(0:19) 6-D3, 11-C3, 13-B3, 13-D4,
15-C2, 25-D1 ISA3_SBHE* 6-B3, 6-C1, 25-B3 ISA3_SD(0:15) 6-C1, 6-C3, 11-C2, 13-C4,
15-C2, 25-D1 ISA3_TC 7-A4, 13-B4, 25-C3 ISA3_ZWS* 6-B3, 6-C1, 13-B4, 25-B3 KBC2_PWRGDBX 3-D3, 16-D1, 25-C4 KBC3_EXTSMI* 7-B2, 8-D1, 25-C3 KBC3_PWRGDPX4 7-B1, 16-D1, 25-C3 KBC3_RUNSCI* 7-D4, 8-D1, 25-D3 KBC3_WAKESCI* 7-C4, 8-C1, 25-D3 KBC5_A20G 6-A4, 15-C2, 25-A3 KBC5_BKLTON 15-B2, 19-B2, 25-A1 KBC5_BRIT 15-C1, 19-C2, 25-A1
Signal Name Sheet Number - Location
KBC5_CAPSLED 15-B2, 16-A4, 25-A1 KBC5_CAPSLED* 16-A4, 17-B3, 26-D3 KBC5_CHGEN 15-B3, 17-B3, 23-B2, 25-B1 KBC5_CHGMOD 15-B3, 23-B1, 25-B1 KBC5_CPURST 6-A4, 15-B3, 25-A3 KBC5_DCKDCEN 15-C2, 20-A3, 25-B1 KBC5_EXTSMI* 8-D2, 15-B2, 25-C2 KBC5_FCTRL 15-D2, 16-D4, 25-B1 KBC5_FVPP 15-B1, 16-D3, 25-A1 KBC5_KSI(0:7) 15-B3, 17-C2, 26-B3 KBC5_KSO(0:15) 15-C3, 17-D2, 26-B3 KBC5_LBLED 15-B2, 16-A3, 25-A1 KBC5_LBLED* 16-A3, 17-B3, 26-D3 KBC5_LIDCLOSE* 16-A1, 19-B2, 19-D1, 26-C3 KBC5_MCHG* 15-B3, 23-B2, 25-B1 KBC5_NUMLED 15-B2, 16-B3, 25-B1 KBC5_NUMLED* 16-B3, 17-B3, 26-D3 KBC5_PWRGD* 15-B2, 16-D2, 25-A1 KBC5_PWRON 15-B2, 23-C2, 25-A1 KBC5_PWRSW* 15-B1, 15-D3, 20-A2, 23-C1,
25-A1 KBC5_QS* 15-B3, 23-B2, 25-B1 KBC5_RING* 15-C1, 16-C1, 25-A1 KBC5_RST* 15-B1, 23-C2, 25-A1 KBC5_RUNSCI 8-D2, 15-C2, 25-C2 KBC5_SCLED 15-B2, 16-B4, 25-B1 KBC5_SCLED* 16-B4, 17-B3, 26-D3 KBC5_SMCLKLI* 15-C1, 16-B3, 25-A1 KBC5_SMDATAMH*
15-B3, 16-C3, 25-B1 KBC5_SPKMUTE 15-D3, 20-C1, 22-B2, 25-A1 KBC5_TCLK 15-C3, 17-B3, 25-B1 KBC5_TDATA 15-C3, 17-B3, 25-B1 KBC5_VOLDN* 15-D3, 22-B4, 25-B1 KBC5_VOLUP* 15-D3, 22-B4, 25-A1 KBC5_WAKESCI* 8-C2, 15-D2, 25-B2 LCD_VDD3V 19-B1, 19-C2, 26-D3 LCD5_BKLTON 19-B1, 19-D1, 26-D3 LCD5_BRIT 19-C1, 19-D1, 26-D3 MDM3_PME* 8-C2, 24-C2, 25-B2
5 Schematic Diagrams and PCB Silkscreen
5-31S820/S850
Signal Name Sheet Number - Location
MDM3_RI* 16-C2, 24-C3, 26-D3 MDM5_AUDIO 22-B1, 24-B2, 26-B3 MEM3_CKE0 3-D3, 5-C3, 25-D4 MEM3_CKE1 3-D3, 5-C3, 25-D4 MEM3_CKE2 3-D3, 5-C1, 25-D4 MEM3_CKE3 3-D3, 5-C1, 25-D4 MEM3_CSA0* 3-D4, 5-C4, 25-C4 MEM3_CSA1* 3-D4, 5-C4, 25-C4 MEM3_CSA2* 3-D4, 5-C2, 25-C4 MEM3_CSA3* 3-D4, 5-C2, 25-C4 MEM3_DQMA*(0:7) 3-D3, 5-B1, 5-B2, 5-B3,
5-B4, 5-C1, 5-C2, 5-C3, 5-C4
MEM3_MA(0:13) 3-D1, 4-C2, 4-D2, 5-B1,
5-B2, 5-B3, 5-B4, 5-C1, 5-C2 MEM3_MD(0:63) 3-A1, 4-C4, 25-D1 MEM3_MWEA* 3-D3, 5-C2, 5-C4, 25-D4 MEM3_RMD(0:63) 4-B2, 5-D2, 5-D4, 25-D1 MEM3_SCASA* 3-D3, 5-C1, 5-C3, 25-D4 MEM3_SRASA* 3-D3, 5-C2, 5-C4, 25-D4 MMO3_MID0 3-D2, 7-C4, 25-D3 MMO3_MID1 3-D2, 7-C4, 25-D3 MMO3_MID2 3-D2, 7-C4, 25-D3 MMO3_MID3 3-D2, 7-C4, 25-D3 MMO3_VRPWRGD 3-D3, 7-B1, 25-C3 NBX3_DCLKO 2-B3, 3-A4, 25-D4 NBX3_FQS 2-C4, 3-A4, 25-D4 NBX3_GCLKO 3-A4, 18-A2, 18-C2, 25-B4 PCI3_AD(0:31) 3-D4, 6-B4, 6-D4, 9-A4,
20-A2, 20-D2, 22-C3, 22-D4,
24-B2 PCI3_CBE0* 3-C4, 6-C4, 9-A3, 20-A2,
22-C3, 24-C2, 25-B4 PCI3_CBE1* 3-C4, 6-C4, 9-A3, 20-A2,
22-C3, 24-C2, 25-B4 PCI3_CBE2* 3-C4, 6-C4, 9-A3, 20-A2,
22-C3, 24-C3, 25-B4 PCI3_CBE3* 3-C4, 6-B4, 9-A3, 20-A2,
22-C3, 24-C3, 25-B4 PCI3_CLKRUN* 3-B4, 6-B4, 6-C1, 9-A2,
Signal Name Sheet Number - Location
18-B2, 22-B4, 24-C2, 25-B4
PCI3_DEVSEL* 3-C4, 6-B4, 6-D1, 9-A2,
20-C2, 22-C3, 24-C3, 25-B4
PCI3_FRAME* 3-C4, 6-B4, 6-C1, 9-A2,
20-A2, 22-C3, 24-C2, 25-B4 PCI3_GNT0* 3-B4, 6-D1, 20-C2, 25-A4 PCI3_GNT1* 3-B4, 6-D1, 20-C2, 25-A4 PCI3_GNT2* 3-B4, 6-D1, 24-B3, 25-A4 PCI3_GNT3* 3-B4, 6-D1, 9-A2, 25-A4 PCI3_GNT4* 3-B4, 6-D1, 22-C3, 25-A4 PCI3_INTA* 6-D1, 7-B2, 9-A1, 20-A2,
24-B2, 25-A3 PCI3_INTB* 6-D1, 7-B2, 9-A1, 20-C2,
25-A3 PCI3_INTC* 6-D1, 7-B2, 18-B2, 20-A2,
22-C3, 25-A3 PCI3_INTD* 6-D1, 7-B2, 20-C2, 25-A3 PCI3_IRDY* 3-B4, 6-B4, 6-D1, 9-A2,
20-A2, 22-C3, 24-C3, 25-B4 PCI3_PAR 3-B4, 6-B4, 6-D1, 9-A2,
20-C2, 22-C3, 24-C3, 25-B4 PCI3_PERR* 6-C1, 9-A2, 24-C3, 25-A3 PCI3_PHLDA* 3-B4, 6-B4, 6-D1, 25-B4 PCI3_PHOLD* 3-B4, 6-B4, 6-D1, 25-B4 PCI3_PLOCK* 3-B4, 6-D1, 9-A2, 20-C2,
22-C3, 25-B4 PCI3_REQ0* 3-B4, 6-B4, 6-D1, 20-C2,
25-A4 PCI3_REQ1* 3-B4, 6-A4, 6-D1, 20-C2,
25-A4 PCI3_REQ2* 3-B4, 6-A4, 6-C1, 24-B3,
25-A4 PCI3_REQ3* 3-B4, 6-A4, 6-C1, 9-A2,
25-A4 PCI3_REQ4* 3-B4, 6-A4, 6-C1, 22-C3,
25-A4 PCI3_RST* 3-B4, 6-B4, 9-A2, 10-B2,
18-B2, 20-C4, 22-B2, 22-C3,
24-C3
Loading...
+ 10 hidden pages