SAMSUNG MAX-WL85, MAX-L82 Alignment and Adjustments

1Samsung Electronics
1. Alignment and Adjustments
1. Tuner
FM THD Adjustment
Output
Output
28 dB(±2dB)
60 dB
Minumum Distortion (0.4% below) (Figure 1-1)
SSG FREQ.
Adjustment point (FM DET)
98 MHz
FM DETECTOR COIL
FM Search Level Adjustment
Adjust SVR1 so that “TUNED” of FLT is lighted (Figure 1-2)
Figure1-2 FM Auto Search Level Adjustment
*Adjust FM S.S.G level to 28dB
Figure1-1 IF CENTER and THD Adjustment
SSG FREQ.
Adjustment point
(SVR1)
98 MHz
BEACON SENSITIVITY SEMI-VR(10KΩ)
FM S.S.G
GND
28 dB
FM S.S.G
Output GND
Speaker Terminal
FM Antenna Terminal
Distortion Meter
Input
SET
Input
output
Oscilloscope
FM IN
FM Antenna
SET
20 k
OUTPUT
AM SSG 450KHZ
INPUT
AM ANT IN
Speaker Terminal
60cm
AM IF
VTVM Oscilloscope
AM(MW) I.F Adjustment
Maximum output (Figure 1-3)
SSG FREQ.
Frequency
Adjustment point
450 kHz
522 kHz
AM IF
Figure1-3 AM I.F Adjustment
OUTPUT
* Adjustment Location of Tuner PCB
AM(MW) OSC
Output
1~7.0±0.5V
Received FREQ.
Adjustment
point
522~1611 KHz
MO
AM(MW) RF
ITEAM
594 KHz
MA
Maximum Output (Fig1-4)
TESTER
MAIN PCB
VT GND
Fig 1-4 OSC Voltage
LW OSC
146~290 KHz
LO
2~7.0±0.5V
AM(MW) RF
150 KHz
LA
Maximum Output (Fig1-4)
SW1 OSC
2.3~7.3 MHz
LO
1~8V±1V
SW1 RF
3.5MHz
MA
Maximum Output (Fig1-4)
SW2 OSC
9.5~26.1MHz
LO
SW2 RF
10MHz
MA
Maximum Output (Fig1-4)
1~8V±1V
(GND)
VTVM
Alignment and Adjustments
2 Samsung Electronics
2-1To Adjust Tape Speed
1) Measuring tape: i) MTT-111 (or equivalent) (Tapes recorded with 3kHz)
ii) MTT-5512 (or equivalent)
iii) MTT-112B (or equivalent)
2) Connect the cassette deck to the frequency counter
as in figure 1-5.
1) Before the actual adjustment, clean the play/recording
head.
2) Measuring tape :
i) MTT-114N(or equivalent 10kHz AZIMUTH control)
ii) MTT-5512
3) The cassette deck is connections as shown in figure 1-7.
Notes
Notes
NOR SPEED Control
1
OUT
(connected
to the frequency
counter)
Turn CSVR1 toleft and right (MAIN PCB)
3KHz±30Hz
Remark
Standard
To Adjust
Pre-Setup
Item
Step
Pre-Setup Condition
1) Deck 1:MTT-111
2) Press PLAY
SW button
3) Deck 2:Same
as above
AZIMUTH
1
SPK OUT
(VTVM is
connected to
the scope)
- Turn the control screw to as shown in Figure 1-6.
Max output and same phase (both channels)
After adjustment secure it with REGION LOCK.
Remark
Standard
To Adjust
Pre-Setup
Item
Step
Pre-Setup Condition
After putting MTT-
114N into Deck 1
- Press FWD PLAY
button.
AZIMUTH
1
2
SPK OUT
(VTVM is
connected to
the scope)
- Turn the control screw to as shown in Figure 1-6.
Max output and same phase (both channels)
After adjustment secure it with REGION LOCK.
6V(±0.5V)
Turn DSVR1,DSVR2
to the right and left
Remark
Standard
To Adjust
Pre-Setup
Item
Step
Pre-Setup Condition
Fig 1-8
After putting MTT-
114N into Deck 2
1)Press FWD PLAY
button.
After putting MTT-
5512 into Deck 2
1)Press REC PLAY
button.
2)MAIN PCB DCW3,
connectted to VTVM
Recording Bias Voltage
2-4 To Adjust PlayBack Level/REC
2. Adjust Deck 2 Play Level/REC BIAS
1. Adjust Deck 1 Play Level
Cassette Deck
output
SPK OUT
Frequency Counter
Figure 1-5
Figure 1-6
SPK OUT
Recording /Play head
AZIMUTH control screw
Figure 1-7
In Out
Cassette Deck
Oscilloscope
2 Cassette Deck
±1%
range
Figure 1-8
Audio OSC.
SET (MAIN PCB)
Oscilloscope
AUX IN
LINE OUT
VTVM
IN
DCW3
IN OUT
TP
REC Bias Voltage
1
Connect to
DCW3 as in
Fig.1-8 and read
the VTVM.
Turn DL4 to the right and left.
105KHz±0.5KHz
Remark
Standard
To Adjust
Pre-Setup
Item
Step
Pre-Setup Condition
Input MTT-5512
into Deck2,then
press REC button.
MAIN PCB
2-2. Adjust REC Bias Voltage
L,R UNBAL­ANCE
1
Connect to
DCW3 as in
Fig.1-8 and read
the VTVM.
Turn DSVR3 to the right and left.
±0.5dB
Remark
Standard
To Adjust
Pre-Setup
Item
Step
Pre-Setup Condition
Input MTT-112B
into Deck2,then
press PLAY button.
MAIN PCB
2-3. Adjust L,R UNBALANCE
Loading...