4. Disassembly & Reassembly
4-1 Replacement of Magnetron, Motor Assembly and Lamp
Remove the magnetron including the shield case, permanent magnet, choke coils andF capacitors (all of which are contained in one assembly).
1.Disconnect all lead wires from the magnetron and lamp.
2.Remove a screw securing the magnetron supporter.
3.Remove the magnetron supporter.
4.Remove the air cover.
5.Remove screws securing the magnetron to the wave guide.
6.Take out the magnetron very carefully.
7.Remove screws from the back panel.
8.Take out the fan motor.
9.Remove the oven lamp by rotating to pull out from hole of air cover.
NOTE1: When removing the magnetron, make sure that its antenna does not hit any adjacent parts, or it may be damaged.
NOTE2: When replacing the magnetron, be sure to remount the magnetron gasket in the correct position and make sure the gasket is in good condition.
|
|
Thermo S/W |
Lamp |
||
|
|
|
Fan Motor
Magnetron
Screw
H. V. Trans H. V. Capacitor
4-2 Replacement of High Voltage Transformer
1.Discharge the high voltage capacitor.
2.Disconnect all the leads from the high voltage transformer.
3.Remove the mounting bolts on the high voltage transformer.
4.When replacing, connect the leads correctly and firmly.
H. V. Trans
Screws
4-1
Disassembly & Reassembly
4-3 Replacement of Door Assembly
4-3-1 Removal of Door Assembly
Remove hex bolts securing the upper hinge and |
Hinge Upper |
lower hinge. Then remove the door assembly. |
|
Screw
Hinge Lower
4-3-2 Removal of Door "C"
Insert flat screwdriver into the gap between Door "E" and Door "C" to remove Door "C". Be careful when handling Door "C" because it is fragile.
4-3-3 Removal of Door "E"
Following the procedure as shown in the figure, insert and bend a thin metal plate between Door "E" and Door "A" until you hear the 'tick' sound.
1.Insertion depth of the thin metal plate should be 0.5mm or less.
4-3-4 Removal of Key Door & Spring
Remove pin hinge from Door "E"
Detach spring from Door "E" and key door.
Door "E"
Door Key |
Spring Key |
4-2