Customer : Visual Display Division DATE : 14. Dec. 2011
Any Modification of Specification is not allowed without SDC's Permission.
Samsung Display Co . , LTD.
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
1/28
www.panelook.com
Page 2
Global LCD Panel Exchange Center
Revision History
DateRev. NoPageSummary
www.panelook.com
14. Dec. 2011
000allFirst issued
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
2/28
www.panelook.com
Page 3
Global LCD Panel Exchange Center
www.panelook.com
General Description
Description
LSJ400HL02 is a color active matrix liquid crystal display (LCD) that uses amorphous
silicon TFT( Thin Film Transistor) as switching components. This model is composed of a
TFT LCD panel, a driver circuit. The resolution of a 40“ is 1920 x 1080 and this model can
display up to 16.7 million colors with wide viewing angle of 89¶ or higher in all directions.
This panel is intended to support applications to provide a excellent performance for Flat
Panel Display such as Home-alone Multimedia TFT-LCD TV and High Definition TV.
Features
High contrast & aperture ratio with wide color gamut
SPVA (Super Patterned Vertical Align) mode
Wide viewing angle (·178¶)
High speed response
FHD resolution (16:9)
2Ch LVDS (Low Voltage Differential Signaling) interface
2D / 3D function compatible
General Information
ItemsSpecificationUnitNote
Panel Size
Weight1.8(Max)kg
Pixel Pitch0.46125(H) X 0.15375(V)mm
Active Display Area885.6(H) X 498.15(V)mm
Surface TreatmentHaze 0%, Hard-coating (2H)
Display Colors16.7M (8Bits)colors
Number of Pixels1920 x 1080pixel
Pixel ArrangementRGB vertical stripe
Display ModeNormally Black
893.5(H) x 506.05(V)
1.76(D)
·1.0mm
mm
Max
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
3/28
www.panelook.com
Page 4
Global LCD Panel Exchange Center
www.panelook.com
1. Absolute Maximum Ratings
If the condition exceeds maximum ratings, it can cause malfunction or unrecoverable
damage to the device.
ItemSymbolMin.Max.UnitNote
(ڱ
ڮڮ ژٻڋٻڱڄ
Power Supply VoltageV
Storage temperatureT
DD
STG
10.813.2V(1)
-2065
Glass surface
temperature
CenterT
OPR
050
(Operation)
Note (1) Ta= 25 · 2 ¶C
(2) Temperature and relative humidity range are shown in the figure below.
a. 90 % RH Max. (Ta ≤ 39 ¶C)
b. Relative Humidity is 90% or less. (Ta > 39 ¶C)
c. No condensation
(2)
(2)
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
4/28
www.panelook.com
Page 5
Global LCD Panel Exchange Center
www.panelook.com
2. Optical Characteristics
The optical characteristics should be measured in a dark room or equivalent.
Measuring equipment :
ItemSymbolConditionMin.Typ.Max.UnitNote
TOPCON RD-80S, TOPCON SR-3 ,ELDIM EZ-Contrast
(Ta = 25 · 2¶C, VDD=12V )
Contrast Ratio
(Center of screen)
Response
Time
Transmittance T4.464.8-%
Color
Chromaticity
(CIE 1931)
sRGB Concordance--98.5-%
Color Temperature--10,000-K
G-to-GTg-412msec
Red
Green
Blue
White
C/R
Normal
Rx
Ry0.330
Gx0.300
Gy0.600
Bx0.150
By0.060
Wx0.280
Wy0.290
TL,R=0
TU,D=0
Viewing
Angle
4,0005,000-
0.640
TYP.
-0.03
TYP.
+0.03
(1)
SR-3
(3)
RD-80S
(4)
SR-3
(5),(6)
SR-3
(5)
SR-3
T
Hor.
Viewing
Angle
Ver.
Transmittance
Uniformity
(9 Points)
L
T
R
T
U
T
D
T
uni
C/R≥10
Notice
(a) Test Equipment Setup
The measurement should be executed in a stable, windless and dark room between
40min and 60min after operating the Panel at the given temperature for stabilization
of the standard light(SEC use standard illuminant D65 Media).
This should be measured in the center of screen. Environment condition : Ta = 25 · 2 ¶C
(b) D65 Media means general available light source.
Color Temperature is 6504K , a color coordinate is Wx 0.2948, Wy 0.322,
Luminance is 3389cd/༇
7589-
7589-
7589-
7589-
--
10
Degree
%
(6)
EZ-
Contrast
(2)
SR-3
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
5/28
www.panelook.com
Page 6
Global LCD Panel Exchange Center
ྙ
ྚྛ
ྞ
ྡ
ྠ
ྜྷྜ
ྟ
www.panelook.com
Photo detectorField
SR3
RD-80S
TFT - LCD Module
- Definition of test point
1ദ
2ദ
Photo detector
Field
BM-5A : 50
RD-80S : 50
EZ-Contrast:0༃
LCD Panel
The center of the screen
3209601600
180
540
900
Note (1) Definition of Contrast Ratio (C/R)
: Ratio of gray max (Gmax) & gray min (Gmin) at the center point 䐣 of the panel
: The measurement goes in D65 Standard Light Source
/
CR
max
G
min
G
Gmax : Luminance with all pixels white
Gmin : Luminance with all pixels black
Active Area
Test Point
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
6/28
www.panelook.com
Page 7
Global LCD Panel Exchange Center
www.panelook.com
Note (2) Definition of 9 points Transmittance uniformity (Test pattern : Full White)
The measurement goes in D65 Standard Light Source
Tuni
TT
(max min)
T
max
u
100
Tmax : Maximum Transmittance
Tmin : Minimum Transmittance
Note (3) Definition of Response time : Sum of Tr, Tf
Display data
Optical Instruments
Response
100%
Black (data off)
T
R
White (data on)
90%
10%
0%
Black (data off)
T
F
G-to-G : Average response time between Gray to Gray (Scale)
Note (4) Definition of Luminance of White : Luminance of white at center point 䐣
The measurement goes in D65 Standard Light Source
Note (5) Definition of Color Chromaticity (CIE 1931)
Color coordinate of Red, Green, Blue & White at center point 䐣
The measurement goes in D65 Standard Light Source
Note (6) Definition of Viewing Angle
: Viewing angle range (C/R ≥10)
The measurement goes in D65 Standard Light Source
TIME
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
7/28
www.panelook.com
Page 8
Global LCD Panel Exchange Center
www.panelook.com
3. Electrical Characteristics
3.1 TFT LCD Module
The connector for display data & timing signal should be connected.
Ta = 25¶C · 2 ¶C
ItemSymbolMin.Typ.Max.UnitNote
Voltage of Power SupplyVDD10.812.013.2V(1)
Current
of Power
Supply
(a) Black
IDD
(c) N-pattern-20003000mA
-14001700mA
(2),(3)(b) White-14001700mA
Vsync FrequencyfV---Hz
Hsync FrequencyfH---kHz
Main FrequencyFdclk---MHz
Rush CurrentIRUSH---A(4)
Note (1) The ripple voltage should be controlled under 10% of V
(2) f
V= 240 Hz, fDCLK = 594 MHz, V
= 12.0V, DC Current.
DD
DD
.
(3) Power dissipation check pattern (LCD Module only)
a) Black Pattern b) White Pattern c) uT
(4) Measurement Conditions
V
100%
DD
90%
10%
GND
T
=470༕
RUSH
Rush Current I
can be measured when T
RUSH
. is 470༕.
RUSH
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
8/28
www.panelook.com
Page 9
Global LCD Panel Exchange Center
5.1 LVDS Interface
- LVDS Receiver : FRC
www.panelook.com
LVDS pinJEIDA -DATA
TxIN/RxOUT0R4
TxIN/RxOUT1R5
TxIN/RxOUT2R6
TxOUT/RxIN0
TxOUT/RxIN1
TxOUT/RxIN2
TxIN/RxOUT3R7
TxIN/RxOUT4R8
TxIN/RxOUT5R9
TxIN/RxOUT6G4
TxIN/RxOUT7G5
TxIN/RxOUT8G6
TxIN/RxOUT9G7
TxIN/RxOUT10G8
TxIN/RxOUT11G9
TxIN/RxOUT12B4
TxIN/RxOUT13B5
TxIN/RxOUT14B6
TxIN/RxOUT15B7
TxIN/RxOUT16B8
TxIN/RxOUT17B9
TxIN/RxOUT18HSYNC
TxIN/RxOUT19VSYNC
TxOUT/RxIN3
TxOUT/RxIN4
TxIN/RxOUT20DEN
TxIN/RxOUT21R8
TxIN/RxOUT22R9
TxIN/RxOUT23G8
TxIN/RxOUT24G9
TxIN/RxOUT25B8
TxIN/RxOUT26B9
TxIN/RxOUT27RESERVED
TxIN/RxOUT28
TxIN/RxOUT29
TxIN/RxOUT30
TxIN/RxOUT31
TxIN/RxOUT32
TxIN/RxOUT33
TxIN/RxOUT34RESERVED
yW
yX
nW
nX
iW
iX
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
9/28
www.panelook.com
Page 10
Global LCD Panel Exchange Center
www.panelook.com
5.2 Input Signals, Basic Display Colors and Gray Scale of Each Color
Rn : Red Gray, Gn : Green Gray, Bn : Blue Gray (n = Gray level)
Input Signal : 0 = Low level voltage, 1 = High level voltage
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
10/28
www.panelook.com
Page 11
Global LCD Panel Exchange Center
www.panelook.com
6.3 Timing diagrams of interface signal ( DE only mode )
TV
TVD
DE
TH
THD
DE
DCLK
DATA
SIGNALS
TC
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
11/28
www.panelook.com
Page 12
Global LCD Panel Exchange Center
www.panelook.com
6.4 Power ON/OFF Sequence
To prevent a latch-up or DC operation of the LCD Module, the power on/off
sequence should be as the diagram below.
0.5ms<T1≤10ms
1ms<T2≤50ms
0ms<T3≤50ms
1000ms≤T4
1000ms≤T5
100ms≤T6
T1 : VDDrising time from 10% to 90%
T2 : The time from V
to valid data at power ON.
DD
T3 : The time from valid data off to VDDoff at power Off.
T4 : VDDoff time for Windows restart
T5 : The time from valid data to B/L enable at power ON.
T6 : The time from valid data off to B/L disable at power Off.
The supply voltage of the external system for the Module input should be the same
as the definition of VDD.
Apply the lamp voltage within the LCD operation range. When the back light turns on
before the LCD operation or the LCD turns off before the back light turns off,
the display may momentarily show abnormal screen.
In case of V
= off level,
DD
please keep the level of input signals low or keep a high impedance.
T4 should be measured after the Module has been fully discharged between power off
and on period.
Interface signal should not be kept at high impedance when the power is on.
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
12/28
www.panelook.com
Page 13
Global LCD Panel Exchange Center
7. Outline Dimension
www.panelook.com
BM Tolerance Spec.
- Real BM Width spec. : ·0.1mm
- Gap between Active Center and BM
up/down/right/left : ·0.1mm (a,a’)
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
13/28
www.panelook.com
Page 14
Global LCD Panel Exchange Center
www.panelook.com
9. PACKING
9.1 CARTON (Internal Package)
(1) Packing Form Corrugated fiberboard box and corrugated cardboard as shock absorber
(2) Packing Method
Packing- Upper Box
Pallet Tray
10EA10EA
Pallet-Plastic
10EA
9.2 Packing Specification
ITEMSpecificationRemark
1. 1.90 Kg / LCD (15[ea]/Tray, 300[ea]/Pallet)
LCD Packing300ea / Box
2. 0.05 Kg / Middle sheet (18[ea]/Tray, 360[ea]/Pallet)
3. 1.40 Kg / Panel tray (20ea/Pallet)
4. 1.00 Kg / Packing Box (1ea)
15EA
Pallet-Wood1Box / Pallet
Pallet sizeH x V x height1,485mm(H) x 1,150mm(V) x 1,192mm(height)
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
14/28
www.panelook.com
Page 15
Global LCD Panel Exchange Center
9.3 Middle Sheet Specification
ITEMSpecification
www.panelook.com
Temperature
Measurement Condition
Humidity20% ~ 60%
MaterialPolyethylene
Surface Resistance106~ 10
Static
(No Friction)
Frictional Voltage
Dynamic
(Friction : 5times at once)
9.4 Middle Sheet Outline Dimension
9.9
Ω
Less than 200V
Less than 500V
25
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
15/28
www.panelook.com
Page 16
Global LCD Panel Exchange Center
www.panelook.com
10. MARKING & OTHERS
A nameplate bearing followed by is affixed to a shipped product at the specified
location on each product.
(1) Cell Label
LSJ400HL02
Lot number : X X X X XXX
XX X
Cell Position No. (In the Glass)
Glass No. (In the one Lot)
Lot No. (Glass)
Month
Year (Note1)
Product code
Line
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
16/28
www.panelook.com
Page 17
Global LCD Panel Exchange Center
(2) Box Label
www.panelook.com
LSJ400HL02
xxxx
300
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
17/28
www.panelook.com
Page 18
Global LCD Panel Exchange Center
www.panelook.com
11. General Precautions
11.1 Handling
(a) When the Module is assembled, it should be attached to the system firmly
using all mounting holes. Be careful not to twist and bend the Module.
(b) Refrain from strong mechanical shock and / or any force to the Module.
In addition to damage, this may cause improper operation or damage to the Module
and CCFL back light.
(c) Note that polarizers are very fragile and could be damage easily.
Do not press or scratch the surface harder than a HB pencil lead.
(d) Wipe off water droplets or oil immediately. If you leave the droplets for a long
time, staining or discoloration may occur.
(e) If the surface of the polarizer is dirty, clean it using absorbent cotton or soft cloth.
(f) Desirable cleaners are water, IPA(Isopropyl Alcohol) or Hexane.
Do not use Ketone type materials(ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid
or Methyl chloride. It might permanent damage to the polarizer due to chemical
reaction.
(g) If the liquid crystal material leaks from the panel, it should be kept away
from the eyes or mouth . In case of contact with hands, legs or clothes, it must
be washed away with soap thoroughly.
(h) Protect the module from Electrostatic discharge. Otherwise the ASIC IC or
Semiconductor would be damaged
.
(i) Use finger-stalls with soft gloves in order to keep display clean during the
incoming inspection and assembly process.
(k) Protection film for polarizer on the Module should be slowly peeled off just before use
so that the electrostatic charge can be minimized. Must put on antistatic glove while
handle a module
(l) Pins of I/F connector should not be touched directly with bare hands.
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
18/28
www.panelook.com
Page 19
Global LCD Panel Exchange Center
www.panelook.com
* Process Control Standard
ItemManagement standard value and performance standard
1Anti-static mat (shelf)1 to 50 [Mohm]
2
3Ionizer
Anti-static mat (floor,
desk)
1 to 100 [Mohm]
Attenuate from · 1,000V to · 100V within 2 sec
4Anti-static wrist band0.8 to 10 [Mohm]
Anti-static wrist band
5
entry and ground
Below 1,000 [ohm]
resistance
6Temperature
0 35
7Humidity60 to 70 [%RH]
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
19/28
www.panelook.com
Page 20
Global LCD Panel Exchange Center
www.panelook.com
11.2 Storage
We highly recommend to comply with the criteria in the table below
ITEMUnitMin.Max.
Storage
Temperature
Storage
Humidity
Storage life6 months
- The storage room should provide good ventilation and temperature control.
- Products should not be placed on the floor, but on the Pallet away from
- Prevent products from direct sunlight, moisture nor water; Be cautious of
Storage
Condition
- Avoid other hazardous environment while storing goods.
()540
(%rH)3575
a wall.
a build up of condensation.
After 1 month 2 month3 month4month5 month6month
Baking No backing50Ȕ+U50Ȕ+U
11.3 Operation
(a) Do not connect or disconnect the Module in the "Power On" condition.
(b) Power supply should always be turned on/off by the "Power on/off sequence"
(c) Module has high frequency circuits. Sufficient suppression to the electromagnetic
interference should be done by system manufacturers. Grounding and shielding methods
may be important to minimize the interference.
(d) The cable between the back light connector and its inverter power supply should
be connected directly with a minimized length. A longer cable between
the back light and the inverter may cause lower luminance of lamp(CCFT) and
may require higher startup voltage(Vs).
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
20/28
www.panelook.com
Page 21
Global LCD Panel Exchange Center
www.panelook.com
11.4 Operation Condition Guide
(a) The LCD product should be operated under normal conditions.
(b) If the product will be used in extreme conditions such as high temperature,
humidity, display patterns or operation time etc.., It is strongly recommended
to contact SEC for Application engineering advice. Otherwise, its reliability and
function may not be guaranteed. Extreme conditions are commonly found at
Airports, Transit Stations, Banks, Stock market, and Controlling systems.
11.5 Others
(a) Ultra-violet ray filter is necessary for outdoor operation.
(b) Avoid condensation of water. It may result in improper operation or disconnection
of electrode.
(c) Do not exceed the absolute maximum rating value. ( supply voltage variation,
input voltage variation, variation in part contents and environmental temperature,
and so on)
Otherwise the Module may be damaged.
(d) If the Module keeps displaying the same pattern for a long period of time,
the image may be "sticked" to the screen.
To avoid image sticking, it is recommended to use a screen saver.
(e) This Module has its circuitry PCB's on the rear side and should be handled
carefully in order not to be stressed.
(f) Please contact SEC in advance when you display the same pattern for a long time.
MODELLSJ400HL02Doc. No07-001-S-111214Page
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
21/28
www.panelook.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.