Samsung H1245A Specifications

61 Huuru Prgh
표시
5E
dE
dE1
dE2
UE
HE
HE1
4E
1E
oF
3E
11 E
12 E
13 E
Error Description
Water drain abnormal
Door open/close abnormal
Door lock S/W abnormal
Door lock S/W abnormal
Un-Balance abnormal
Abnormal temperature sensed (Wash Heater Part)
Heating abnormal
Water supply abnormal
Water level sensor abnormal
Over-Flow abnormal
Motor abnormal
Water leak
Power S/W abnormal
Signal communication abnormal
Error Sensing
When door was opened at the starting time of operation.
When Door S/W didn't function with Door Close signal, or When Door S/W didn't function with Door Release signal.
When more than 20 times of Start signal were added to Door lock coil for 2 minutes,
When Unbalance was still sensed after performing 3 times of Unbalance release during the last time of dehydration,
When higher than 100℃of water temperature was sensed by Thermistor,
When the temperature changed more rapidly than 7℃/min during the Heating (for boiling course as an exmaple)
When water was not supplied to the target level in 15 minutes
When the input signal of water level sensor was higher than 30KHz, or less than 10KHz
This error happens when water level reached the Ove rflow leve l(less than 20.48Kh), Door is not opened at this time. (the water is drained by force to the water level less than 22.82Kz)
When more than 16 times of sequential abnormal signals were sensed by Motor Drive Micom(abnormal at Hall-ic, or winding wire)
When water level went down below the Reset level during the washing or rinse.
When the electric contact was not detached during the Power on/off
When signal communication was abnormally interupted between Main Micom and Display Micom for longer than 5sec, and between Main Micom and Motor Micom for longer than 7sec
Error Release
Re-start releases Error.
Re-start releases Error.
Reset of Power S/W releases Error.
Error will be released 2minutes after Error occurrence or by Reset of Power S/W.
Re-start releases Error.
After Error is displayed, Power will be automatically OFF.
Reset of Power S/W releases Error.
Re-start releases Error.
Reset of Power S/W releases Error.
Error will be released by draining water to the levle for Door Open.
Reset of Power S/W releases Error.
Reset of Power S/W releases Error.
Reset of Power S/W releases Error.
When the communication is normalized after Re-start, Error will be released.
tE
8E
14 E
CE
Themister abnormal
Feed hoses of Hot/Cold water oppositely connected.
Button abnormal
Cooling abnormal
When Themister was opened or under detection for checking electric short After Error is displayed, Power will be
automatically OFF.
When hotter than 50℃of water was supplied for the Wool/Lingerie Course
When a button was being continuously pressed longer than 1 minute When Button Under Pressed was
When water temperature was not cooled down below 50℃within 30 minutes after the Heating
Reset of Power S/W releases Error.
released, Error will be automatically released.
Re-start releases Error.
- 17 -
71 V|pswrpv ri Huuruv dqg Uhodwhg Sduwv wr eh Fkhfnhg
H
M
H
Wa
E
L
Wat
e
a
a
at
M
e
er
a
i
l
er
I
g
Sup
t
n
l
Symptoms of Errors
Le
e
M
r
S
o
e
t
n
o
s
r
o
r
ve
Se
ns
or
Fi
lt
l
er
ply
Val
ve
Da
mp
er
Po
we
r
Co
de
Th
er
mi
st
or
Th
er
mo
st
at
D
Dr
Wa
Dr
Do
Do
M
Po
Ma
Di
o
ai
te
ai
or
or
a
we
nu
a-
o
n
r
n
Op
Le
i
r
al
fr
r
Pu
Fe
Ho
en
ve
n
S/
Le
am
S
mp
ed
se
/
W
Ho
se
r
P
W
ve
e
C
B
r
1 Power not On(12E)
Heating not performed.(Boiling course not
2
functioned)
3 Water leaks(11E)
4 Electric leakage happens(circuit breaker gets down).
5 Water not supplied.(4E)
6 Door not locked/not opened.(dE,dE1,dE2)
7 Motor not rotated.(3E)
8 Water not drained.(5E)
11 Loud noise during the dehydration.(uE)
12 Smoke rises from washing machine.
13 Foam comes out.
14 Noise during the water drain
15
Thermistor abnormal(tE)
16
Hot/Cold water oppositely supplied(8E)
- 18 -