CONFIDENTIAL
3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the
GH19P* monitors.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
3-1 Disassembly
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. Follow these directions carefully; never use metal instruments to pry apart the cabinet.
3-1-1 Removing the Stand
1. Remove 4 screws in the hinge area.
2. Disconnect DVI Cable and Signal Cable
and Power cord.
3. Pry it off the back of the monitor.
3-1-2 Main Body Disassembly
1. Face the monitor down on a soft-cushionea
flat surface.
2. Put the jig into the opening hole of the bottom.
3. Open the rear cover partly by pushing the jig
into left and right hole.
4. Put the jig into the opening hole of the topcenter and take the rear cover apart by
pushing it upward.
5. Remove 2 screws on the Inverter PCB.
6. Remove the Main PCB Assembly.
7. Remove 3 screws on the Function PCB from
locking area of Function knob and remove
Function PCB.
GH19P* 3-1
3 Disassembly and Reassembly
3-2 Disassembly
Reassembly procedures are in the reverse order of Disassembly procedures.
1. Put the jig into the left openning hole and lift
up the panel until the snap of the Cover Rear
opens.
2. Put the jig into the right opening hole and lift
up the panel until the snap of the Cover Rear
opens.
CONFIDENTIAL
3. Put the jig into the gap (between the right side
of the panel the and Front Cover) and tilt up
Front Cover until the snap opens.
4. Put the jig into the gap (between the right side
of the panel the and Front Cover) and tilt up
Front Cover until the snap opens.
3-2 GH19P*