SAMSUNG DIGIMAX V3 Service Information CG25001 [eng]

Service Information
S/I NO. 03CG25008
DATE July . 24 . 2003
MODEL DIGIMAX V3
SUBJECT Modified basic data due to applying to F/W 06211
1. Problem :
Unclear Focus (After S1, unclear preview image on LCD)
2. Reason :
⇒⇒⇒⇒
Clear the possibility of 1step control of focus motor with shutter function.
Change F/W (AF: Odd pulse function is prohibited) and processor (AF: 1st pulse
function is prohibited)
3. Troubleshooting :
Change EEPROM DATA after updating firmware (Essential)
ADD.
8C D0 CF 80cm - 14 (add : 94h) data - 14
8D B4 B3 80cm - 22 (add : 95h) data - 22
8F 7E 7D 80cm - 46 (add : 97h) data - 46
91 75 75 80cm - 76 (add : 99h) data - 76
92 70 6F 80cm - 94 (add : 9Ah) data - 94
93 6E 6D 80cm - 112 (add : 9Bh) data - 112
9F EC ED 80cm + 66 (add : 97h) data + 66
A0 105 106 80cm + 84 (add : 98h) data + 84
A3 168 169 80cm + 140 (add : 9Bh) data + 140
Before
update
After