Samsung CKB7227, CKB5237 Disassemble

4-1-1 Cabinet Disassembly
1. With a pad beneath it, stand the monitor on its front with the screen facing downward and the base close to you. Make sure nothing will damage the screen.
2. Working from the back of the monitor remove the signal cover cap out, and remove the 4 screws and carefully pull the rear cabinet up and off the monitor.
3. Remove the 8 screws on the Top Shield and remove it.
4. Remove the 4 screws on the Bottom Cover and pull it upward to remove it.
5. Using pinch-nosed pliers or long-nosed pliers, carefully disconnect the Anode Cap from the CRT.
4-1-2 Removing the Video PCB &
CRT Socket PCB
1. Follow steps 1 through 5 in “Cabinet Disassembly,” above.
2. Disconnect connectors CN103.
3. Lift off the CRT Socket PCB Assembly.
4. Hold the CRT Socket PCB Assembly while you lift the cap on the CRT Socket and pull out the two focus wires, G2 wire.
5. Remove both side screws on the lower edge of the Video PCB Ass’y and the screw on the signal connector and pull the assembly towards you to remove it.
6. Remove all screws on the Video PCB Assembly and remove the Video Shield.
7. Lift out the Video PCB and place it on a flat, level surface that is protected from static electricity.
4-1-3 Removing the Main PCB
1. Follow steps 1 through 5 in “Cabinet Disassembly,” steps 1 through 7 in “Removing the Video PCB and “Removing the CRT Socket PCB,” above.
2. Disconnect the Degaussing Coil at CN600 on the Main PCB.
3. Disconnect all easily accessible ground wires from the CRT GND Assembly and Bottom Chassis.
4. Disconnect the connector between CN_Tilt. on the Main PCB and the Tilt coil.
5. Disconnect the DY connector between the DY and the CN300A_7, CN400, CN401 and CN402 connectors on the Main PCB.
6. Remove the 2 screws on the left and right sides of the PCB Bracket.
7. Carefully lift the Main PCB Ass’y.
8. Remove the 7 screws on the top side of the Main PCB.
9. Lift the Main PCB and place it on a flat, level surface that is protected from static electricity.
CKB5237L/7227L 4-1
4 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the CKB5237L/7227L monitors.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
4-1 Disassembly (CKB7227L)
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. Follow these directions carefully; never use metal instruments to pry apart the cabinet.
4-1-4 CRT Ass’y Disassembly
1. Complete all previous steps.
2. Remove the 4 side screws 2 on the top and 2 on either side of the CRT and lift the CRT Unit Bracket.
3. Unhook the Degaussing Coil Assembly and lift it off the CRT.
4-2-1 Replacing the CRT
1. Loop the CRT Ground Assembly around the back of the CRT and under the 3 corner, metal ears. Position the corner with the spring last.
2. With the Front Cover Assembly lying face down on a protective pad, position the CRT so that the corner metal ears fit properly in the Front Cover Assembly.
3. Replace the 4 corner screws.
4. Replace the Degaussing Coil Assembly and secure the Coil with the plastic Degaussing Coil Holders.
5. Replace the CRT Ground Assembly.
6. Replace the Unit Bracket Assembly.
4-2-2 Replacing the Main PCB
1. Stand the monitor on its front with the screen facing downward.
2. Replace the 7 screws on the top side of the Main PCB.
3. Position the Main PCB Ass’y in the Front Cabinet and secure it on both sides with the screws between the Bottom Chassis and CRT Unit Bracket.
4. Replace the DY connector at the CN300A_7, CN400, CN401 and CN402 connectors on the Main PCB.
5. Replace the connector between CN_Tilt. on the Main PCB and the Tilt Coil.
6. Replace all easily accessible ground wires on the CRT GND Assembly and Bottom Chassis.
4. Remove the 4 corner screws and lift the CRT up and away from the Front Cover Assembly and place it on a padded surface.
Do not lift the CRT by the neck.
Caution: If you will be returning this CRT to
the monitor, be sure to place the CRT face down on a protective pad.
7. Replace the Degaussing Coil at CN600 on the Main PCB.
8. Replace the Anode Cap.
4-2-3Replacing Connector CN103 on the
Video PCB
1. Position the Video Shield and replace all screws.
2. Replace both side screws on the lower edge of the Video PCB Ass’y and the screw on the signal connector.
4-2-4 Replacing the CRT Socket PCB
1. Hold the CRT Socket PCB Ass’y while you lift the Cap on the CRT Socket and replace the two Focus wires, G2 wire.
2. Reconnect the CRT Socket on the CRT pins at the plug/Socket junction.
4-2-5 Cabinet Reassembly
1. Reconnect CN103 on the Video PCB.
2. Position the Top Shield and replace the 8 screws.
3. Replace the 4 screws on the Bottom Cover.
4. Position the Rear Cover making sure that the tabs along the front edge are properly snapped in place. Replace the 4 screws.
5. Replace the signal cable cover cap.
6. Set the monitor on its Base and make sure that the CRT faceplate was not scratched or otherwise damaged.
4 Disassembly and Reassembly
4-2 CKB5237L/7227L
4-2 Reassembly (CKB7227L)
With the CRT facing downward on a protective pad, use the steps that follow to reassemble the monitor.
!
Loading...
+ 2 hidden pages