4-1-1 Cabinet Disassembly
1. With a pad beneath it, stand the monitor on its front with the screen facing downward and the base closest to you. Make sure nothing will damage the screen.
2. Press in the tab on the Cabinet Bottom and pull the Tilt and Swivel Base upward to remove it.
3. Working from the back of the monitor, remove the four screws and remove the Rear Cover.
4. Using pinch-nose pliers or long-nose pliers, carefully disconnect the Anode Cap from the CRT.
Caution: Do not touch the anode contact on
the CRT.
4-1-2 Removing the CRT Socket PCB
1. Complete all previous steps.
2. Disconnect CRT and Main PCB ground wires on CRT Socket PCB and Shield Cover.
3. Desolder the 5 tabs on the underside of the CRT Socket PCB shield and remove the CRT Socket PCB Shield.
4. Using a knife, cut through the silicone bond and lift off the CRT Socket PCB.
5. Disconnect connectors CN102 and two ground wires on the CRT Socket PCB.
4-1-3 Removing the Main PCB
1. Complete all previous steps.
2. Disconnect Degaussing Coil at the CN601 connector on the Main PCB.
3. Disconnect all easily accessible ground wires on the Main PCB and Chassis Bottom.
4. Disconnect the DY connector between the DY and the CN301, CN302, CN502 and CN503 connector on the Main PCB.
5. Remove the screws on the back and along each side of the Chassis Bottom.
6. Carefully lift the Main PCB Ass’y.
7. Remove all other ground wires.
4-1-4 CRT Ass’y Disassembly
1. Complete all previous steps.
2. Straighten the Degaussing Coil Assembly coated metal ties and lift Coil Ass’y from the CRT.
3. Remove the four corner screws and lift the CRT up and away from the Front Cover Assembly and place it on a padded surface.
Caution: Do not lift the CRT by the neck.
If you will be returning this CRT to the monitor, be sure to place the CRT face downward on a protective pad.
CKA42*7L/5227L 4-1
4 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the CKA42*7L/5227L monitors.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
4-1 Disassembly
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. Follow these directions carefully; never use metal instruments to pry apart the cabinet.
4-2-1 Replacing the CRT
1. Loop the CRT Ground Ass’y around the back of the CRT and under the four corner metal ears. Position last the corner with the spring.
2. With the Front Cover Assembly lying face down on a protective pad, position the CRT so that the corner metal ears fit properly in the Front Cover Assembly.
3. Secure the CRT ground Ass’y and CRT at each of the four corners with the CRT screws.
4. Replace the Degaussing Coil Assembly and wrap the Coil with the plastic coated metal ties to hold the Coil in place.
4-2-2 Replacing the Main PCB
1. Stand the monitor on its front with the screen facing downward.
2. Slide the Main PCB into the Chassis Bottom and replace the wires and screws on the Chassis Bottom.
3. Position the Main PCB Ass’y in the front Cabinet and secure it with the screws.
4. Replace both side CRT ground wires on the Chassis Bottom.
5. Replace the Degaussing Coil at the CN601 connector on the Main PCB.
6. Replace the DY connector at the CN301, CN302, CN502 and CN503 connector on the Main PCB.
7. Replace all easily accessible ground wires on the Main PCB and Chassis Bottom.
8. Replace the Anode Cap.
4-2-3 Replacing the CRT Socket PCB
1. Lock the Focus (G3) wire on the CRT Socket and reconnect the Screen (G2) wire on the CRT Socket PCB.
2. Reconnect the CRT Socket on the CRT pins and apply silicon bond at the Plug/Socket Junction.
3. Replace the CRT and Main PCB ground wires on CRT Socket PCB and Shield Cover.
4. Reconnect the connectors CN102 to the CRT Socket PCB.
5. Solder the 5 tabs on the underside of the CRT Socket Shield.
4-2-4 Cabinet Reassembly
1. Complete all previous steps.
2. Position the Rear Cover marking sure the tabs along the front edge are properly snapped in place. Replace the four screws.
3. Snap the Tilt and Swivel Base into position.
4. Set the monitor on its Base and make sure that the CRT faceplate was not scratched or otherwise damaged.
4 Disassembly and Reassembly
4-2 CKA42*7L/5227L
4-2 Reassembly
With the CRT facing downward on a protective pad, use the steps that follow to reassemble the monitor.