OWNER’S
INSTRUCTIONS
AW05MDYEA
Window-type Room Air Conditioner
(Cool)
E R DB98-08575A(1)
Safety Precautions
The following safety precautions must be taken when installing and using your air conditioner.
1The air conditioner must be plugged into its own specific power source, which must be installed in compliance with national wiring, earthing and safety regulations.
Depending on national regulations and your specific installation, you may need to install:
A circuit breaker
For further information on electrical requirements, contact a professional electrician.
This device must be installed according to the national electrical rules.
2Make sure that the unit is correctly ventilated at all times; do NOT place clothing or other materials over it.
3NEVER spill liquids of any kind into the unit.
Should this happen, unplug the unit and contact your installation specialist.
4Do NOT insert anything between the air outlet blades, as it may damage the inner fan and you may be hurt. Keep children away from the unit.
5If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
6Do NOT attempt to repair the unit yourself. If it is damaged in any way, contact:
An authorized service center
The dealer from whom you purchased the air conditioner.
7Do NOT place any blocking objects in front of the unit.
8If the remote control will not be used for a long time, remove the batteries.
9Before throwing out the device, it is necessary to pull back the battery cells
and get rid of them safely.
10The appliance is not intended for use by young children or infirm person without supervision; young children should be supervised to ensure that they do not play with the appliance.
11Do NOT use an extension cord with this product.
CAUTION
The manufacturer does not assume responsibility for accidents or injury caused by an incorrectly installed air conditioner. If you are unsure about installation, contact an installation specialist.
E-2
|
Contents |
|
PREPARING YOUR AIR CONDITIONER |
|
|
■ |
Safety Precautions ......................................................................................... |
2 |
■ Description of Each Component .................................................................... |
4 |
|
■ |
Getting Started ............................................................................................... |
5 |
OPERATING YOUR AIR CONDITIONER |
|
|
■ |
Cooling Your Room ........................................................................................ |
6 |
■ |
Airing Your Room ........................................................................................... |
7 |
■ |
Removing Excess Humidity ............................................................................ |
8 |
■ Adjusting the Air Flow Direction Horizontally .................................................. |
9 |
|
PROGRAMMING YOUR AIR CONDITIONER |
|
|
■ Setting the On Timer ...................................................................................... |
10 |
|
■ Setting the Off Timer ...................................................................................... |
11 |
|
■ Setting the Sleep Timer .................................................................................. |
12 |
|
■ Selecting Energy Saving mode ...................................................................... |
13 |
|
RECOMMENDATIONS FOR USE |
|
|
■ Temperature and Humidity Ranges ................................................................ |
13 |
|
■ |
Cleaning Your Air Conditioner ........................................................................ |
14 |
■ |
Solving Common Problems ............................................................................ |
15 |
■ |
Technical Specifications ................................................................................. |
15 |
INSTALLATION |
|
E-3
Description of Each Component
Inner air flow blades |
Air outlet |
|
(right/left orientation) |
|
|
Air outlet |
|
|
Outer air flow blades |
|
|
|
Air inlet (Outside) |
|
Air inlet (Inside) |
Air filter (Inside) |
|
|
||
Adhesive bottom |
Power plug |
|
gasket |
||
(The type of power plug |
||
(Refer to page 17) |
||
may differ, depending on |
||
|
||
|
the local power supply.) |
Energy Saver |
Temperature/ |
indicator |
Timer settings |
Energy Saver |
|
button |
|
Timer setting button |
Temperature adjustment |
Timer indicator |
buttons |
|
|
Fan speed |
Mode selection button |
adjustment button |
(Cool, Fan, Dry) |
Sleep timer setting button
On/Off button
E-4
Getting Started
You have just purchased a Samsung window-type room air conditioner which should be installed following your installation manual.
Your Owner’s Instructions contain much valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of the unit’s features.
The booklet is organized as follows.
The following figures are shown on pages 4 :
-Description of Each Component
They will help you find the buttons and understand the symbols displayed.
In the manual, you will find a series of step-by-step procedures for each function available.
The illustrations in the step-by-step procedures use four different symbols:
PRESS |
PUSH |
IMPORTANT |
NOTE |
E-5
Cooling Your Room
c
You must select the Cool mode if you wish to lower the temperature in your room. You can also set the Fan speed.
1Press the (On/Off) button.
Result: The air conditioner starts up in the mode selected when the unit was last used.
The unit beeps twice.
The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being:
Plugged in
Stopped
It will start up normally after three minutes.
2If the temperature is not displayed on the control panel:
Press the button on the unit one or more times until the temperature is displayed.
Result: The unit beeps each time you press the button.
The air conditioner starts up in the Cool mode.
You can change modes at any time.
3To adjust the temperature, press the or buttons on the unit one or more times until the desired temperature is displayed.
The temperature can be set between 18°C and 30°C. Result: Each time you press the or buttons:
–The temperature is adjusted by 1°C and displayed on the control panel
–The unit beeps
The air conditioner starts cooling, if the room temperature is higher than the selected temperature.
4To set the fan speed:
Press the button on the unit one or more times until the desired Fan speed(F1, F2 or F3) is displayed.
Low
Medium
High
5 To control the direction of the air flow, refer to page 9.
E-6