3. Installation and Operating Instructions
3-1 Installation
3-1-1 Selecting Area for Installation
1. Make sure that you install the unit in an area
providing good ventilation. The air conditioner
must not be blocked by any obstacle affecting the
air flow near the air inlet and air outlet.
2. Make sure that you install the unit in an area that
allow good air handling. The installation area
must be able to endure vibration from the unit.
3. Make sure that you install the unit away from
heat or vapor.
4. Make sure that you install the unit in an area
which is cool and has adequate space.
5. Make sure that you install the unit in an area
away from TVs, audio units, cordless phones,
fluorescent lighting fixtures and other electrical
appliances (obtain a clearance of at least one
meter).
6. Make sure that you install the unit in an area
which provides easy drainage for condensed
water.
7. Make sure that you install the unit in an area not
exposed to rain or direct sunlight.
(Install a separate sunblind if exposed to direct
sunlight.)
8. Make sure that you install the unit in an area
allowing good air movement. Do not install it in
a space that would cause noise amplification of
noise.
9. Fix the unit firmly if mounted in a high place.
Caution:
Do not use the air conditioner in the following environments : greasy areas (including areas near
machines), or marine areas. Contact your local dealer for advice.
Samsung Electronics 3-1
3-2 Controls and Components
AW05M0YEA AW05M0YEB
AW05M0YBA AW05J0YAA
3-2-1 Thermostat
3-2-1 Thermostat
Temperature control dial
Operating mode selection dial
Selector
OFF :
When the room temperature is lowered by the
air conditioner , the gas within the thermostat
will contract and cause a break in the electric
contact. The compressor will then stop.
After the compr essor stops, the room
temperature will rise
ON :
As the room temperature increases to a
selected level, the gas within the thermostat
expands, causing electric contact, which
provides the source of electric power to the
compressor. The room temperature will fall
and the cycle will repeat.
Control Operation :
By turning the contr ol knob clockwise(toward
higher numbers), the temperatures will be cooler.
By turning the contr ol knob counterclockwise
(toward lower numbers), the temperature will be
warmer.
Level 1 : Cool air will be supplied above 30~35°C
Level 1 : Cool air will be ceased below 28~32.5°C
Level 1 :
Level 10 : Cool air will be supplied above 17.4~20.4°C
Level 10 : Cool air will be ceased below 14.4~17.4°C
Level 10 :
.
3-2-2 Operation
The fan selector switch offers high and low fan cooling contr ol levels to assure maximum comfort.
The two fan speeds allow you to economically circulate room air flow on days when intense cooling is
not required. When combined with the thermostat(set to call for conditioned air), these contr ols cool,
dehumidify , filter, and circulate room air, with the fan continuing to cir culate air even when the
compressor is turned off.
.
°C
3-2-3 Fan speed switch
The fan speed switch offers high and low fan cooling contr ol levels to assure maximum comfort.
The two fan speeds allow you to economically circulate room air flow on days when intense cooling is
not required. When combined with the thermostat(set to activate the air conditioner)hese controls cool,
dehumidify , filter, and circulate room air, with the fan continuing to cir culate air while the compr essor is
turned of f.
3-2 Samsung Electronics