ROOM AIR CONDITIONER
AW05B0LA(AW0519)
SERVICE Manual
AIR CONDITIONER |
CONTENTS |
1. Precautions
2. Product Specifications
3. Installation and Operating
Instructions
4. Disassembly and Reassembly
5. Troubleshooting
6. Exploded Views and Parts List
7. Block Diagram
8. Wiring Diagram
ELECTRONICS
©Samsung Electronics Co., Ltd. NOV. 1998. Printed in Korea.
Code No. DB81-00023A(1)
1. Precautions
1.Warning: Prior to repair, disconnect the power cord from the circuit breaker.
2.Use proper parts: Use only exact replacement parts. (Also, we recommend replacing parts rather than repairing them.)
3.Use the proper tools: Use the proper tools and test equipment, and know how to use equipment may cause problems laterintermittent contact, for example.
4.Power Cord: Prior to repair, check the power cord and replace it if necessary.
5.Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire.
6.After completing repairs and reassembly, check the insulation resistance, Procedure: Prior to applying power, measure the resistance between the power cord and the ground terminal. The resistance must be greater than 30 megohms.
7.Make sure that the grounds are adequate.
8.Make sure that the installation conditions are satisfactory. Relocate the unit if necessary.
9.Keep children away from the unit while it is being repaired.
10.Be sure to clean the unit and its surrounding area.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
Samsung Electronics |
1-1 |
2. Product Specifications
2-1 Table
Item |
Unit of Measure |
AW05B0LA(AW0519) |
Remarks |
|
|
|
|
Type |
- |
Window |
|
|
|
|
|
Dimensions: |
Inches |
17-7/8 x 12-3/4 x 12 |
|
|
|
|
|
Width x Height x Depth |
mm |
452 x 305 x 325 |
|
|
|
|
|
Packing Size: |
Inches |
19-1/2 x 17-1/2 x 15 |
|
|
|
|
|
Width x Height x Depth |
mm |
493 x 380 x 442 |
|
|
|
|
|
Voltage: |
Volt |
115 |
|
|
|
|
|
Phase |
- |
Single |
|
|
|
|
|
Frequency |
Hz |
60 |
|
|
|
|
|
Operating Current |
A |
5.6 |
|
|
|
|
|
Power Consumption |
W |
625 |
|
|
|
|
|
Refrigerant Type |
FREON |
R-22 |
|
|
|
|
|
Refrigerant Charge |
OZ |
11.6 |
|
|
|
|
|
Cooling Capacity |
BTU/h |
5,000 |
|
|
|
|
|
E.E.R |
(BTU/h,W) |
8.0 |
|
|
|
|
|
Humidity Removed |
LT/h |
0.8 |
|
|
|
|
|
Air Circulation |
C.F.M |
125 |
|
|
|
|
|
Net Weight |
LBS |
51 |
|
|
|
|
|
Condenser |
Row |
1 |
|
|
|
|
|
Condenser Fan |
Type |
Propeller Fan |
|
|
|
|
|
Evaporator |
Row |
1 |
|
|
|
|
|
Evaporator Fan |
Type |
Squirrel Cage |
|
|
|
|
|
Fan Motor |
Model |
IC - 9625SWD6C |
|
|
|
|
|
Compressor(Rotary) |
Model |
44A056HW2E1 |
|
|
|
|
|
Overload Protect |
- |
MRA12040-12008 |
|
|
|
|
|
Fan Motor Capacitor |
µF/VAC |
6 & 30/330 |
|
|
|
|
|
Compressor Capacitor |
µF/VAC |
(DUAL TYPE) |
|
|
|
|
|
Plug Type |
- |
Parallel |
|
|
|
|
|
Fan Speed Control |
- |
Selector S/W |
|
|
|
|
|
Thermo Control |
- |
Thermostat |
|
|
|
|
|
Design Pressure |
PSI |
300/150 |
|
High Side/Low Side |
|
||
|
|
|
|
|
|
|
|
Samsung Electronics |
2-1 |
2-2 Dimensions
Unit : mm
305 |
305 |
325
452
2-2 |
Samsung Electronics |