SAMSUNG AW0519_XAA.10029.1.15 Service Manual

ROOM AIR CONDITIONER
AW05B0LA(AW0519)
Manual
SERVICE
AIR CONDITIONER CONTENTS
1. Precautions
2. Product Specifications
3. Installation and Operating Instructions
4. Disassembly and Reassembly
6. Exploded Views and Parts List
7. Block Diagram
8. Wiring Diagram
ELECTRONICS
Samsung Electronics Co., Ltd. NOV. 1998.
©
Printed in Korea. Code No. DB81-00023A(1)
1. Precautions
1. Warning: Prior to repair, disconnect the power cord from the circuit breaker.
2. Use proper parts: Use only exact replacement parts. (Also, we recommend replacing parts rather than repairing them.)
3. Use the proper tools: Use the proper tools and test equipment, and know how to use equipment may cause problems later­intermittent contact, for example.
4. Power Cord: Prior to repair, check the power cord and replace it if necessary.
5. Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire.
6. After completing repairs and reassembly, check the insulation resistance, Procedure: Prior to applying power, measure the resistance between the power cord and the ground terminal. The resistance must be greater than 30 megohms.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
7. Make sure that the grounds are adequate.
8. Make sure that the installation conditions are satisfactory. Relocate the unit if necessary.
9. Keep children away from the unit while it is being repaired.
10. Be sure to clean the unit and its surrounding area.
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
Samsung Electronics 1-1
2. Product Specifications
2-1 Table
Item
Type Dimensions: Width x Height x Depth Packing Size: Width x Height x Depth Voltage: Phase Frequency Operating Current Power Consumption Refrigerant Type Refrigerant Charge Cooling Capacity E.E.R Humidity Removed Air Circulation Net Weight Condenser Condenser Fan Evaporator Evaporator Fan Fan Motor Compressor(Rotary) Overload Protect Fan Motor Capacitor Compressor Capacitor Plug Type Fan Speed Control Thermo Control Design Pressure High Side/Low Side
Unit of Measure
-
Inches
mm
Inches
mm Volt
-
Hz
A
W
FREON
OZ
BTU/h
(BTU/h,W)
LT/h
C.F.M
LBS Row Type Row Type
Model Model
-
µ
F/VAC
µ
F/VAC
-
-
-
PSI
AW05B0LA(AW0519)
Window
17-7/8 x 12-3/4 x 12
452 x 305 x 325
19-1/2 x 17-1/2 x 15
493 x 380 x 442
115
Single
60
5.6
625
R-22
11.6
5,000
8.0
0.8
125
51
1
Propeller Fan
1
Squirrel Cage
IC - 9625SWD6C
44A056HW2E1
MRA12040-12008
6 & 30/330
(DUAL TYPE)
Parallel
Selector S/W
Thermostat
300/150
Remarks
Samsung Electronics 2-1
2-2 Dimensions
452
325
305
305
Unit : mm
2-2 Samsung Electronics