ROOM AIR CONDITIONER
AW05B0LA(AW0519)
Manual
SERVICE
AIR CONDITIONER CONTENTS
1. Precautions
2. Product Specifications
3. Installation and Operating
Instructions
4. Disassembly and Reassembly
5. Troubleshooting
6. Exploded Views and Parts List
7. Block Diagram
8. Wiring Diagram
Samsung Electronics Co., Ltd. NOV. 1998.
©
Printed in Korea.
Code No. DB81-00023A(1)
1. Precautions
1. Warning: Prior to repair, disconnect the
power cord from the circuit breaker.
2. Use proper parts: Use only exact
replacement parts. (Also, we recommend
replacing parts rather than repairing them.)
3. Use the proper tools: Use the proper tools
and test equipment, and know how to use
equipment may cause problems laterintermittent contact, for example.
4. Power Cord: Prior to repair, check the
power cord and replace it if necessary.
5. Avoid using an extension cord, and avoid
tapping into a power cord. This practice
may result in malfunction or fire.
6. After completing repairs and reassembly,
check the insulation resistance, Procedure:
Prior to applying power, measure the
resistance between the power cord and the
ground terminal. The resistance must be
greater than 30 megohms.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
7. Make sure that the grounds are adequate.
8. Make sure that the installation conditions
are satisfactory. Relocate the unit if
necessary.
9. Keep children away from the unit while it is
being repaired.
10. Be sure to clean the unit and its surrounding
area.
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
Samsung Electronics 1-1
2. Product Specifications
2-1 Table
Item
Type
Dimensions:
Width x Height x Depth
Packing Size:
Width x Height x Depth
Voltage:
Phase
Frequency
Operating Current
Power Consumption
Refrigerant Type
Refrigerant Charge
Cooling Capacity
E.E.R
Humidity Removed
Air Circulation
Net Weight
Condenser
Condenser Fan
Evaporator
Evaporator Fan
Fan Motor
Compressor(Rotary)
Overload Protect
Fan Motor Capacitor
Compressor Capacitor
Plug Type
Fan Speed Control
Thermo Control
Design Pressure
High Side/Low Side
Unit of Measure
-
Inches
mm
Inches
mm
Volt
-
Hz
A
W
FREON
OZ
BTU/h
(BTU/h,W)
LT/h
C.F.M
LBS
Row
Type
Row
Type
Model
Model
-
µ
F/VAC
µ
F/VAC
-
-
-
PSI
AW05B0LA(AW0519)
Window
17-7/8 x 12-3/4 x 12
452 x 305 x 325
19-1/2 x 17-1/2 x 15
493 x 380 x 442
115
Single
60
5.6
625
R-22
11.6
5,000
8.0
0.8
125
51
1
Propeller Fan
1
Squirrel Cage
IC - 9625SWD6C
44A056HW2E1
MRA12040-12008
6 & 30/330
(DUAL TYPE)
Parallel
Selector S/W
Thermostat
300/150
Remarks
Samsung Electronics 2-1