3. Installation and Operating Instructions
3-1 Installation
3-1-1 Selecting Area for Installation
Select an area for installation that is suitable to the
customerÕs needs.
1. Make sure that you install the unit in an area
providing good ventilation. The air conditioner
must not be blocked by any obstacles affecting the
airflow near the air inlet and the air outlet.
2. Make sure that you install the unit in an area that
allows good air handling. The installation area
must be able to endure vibration from the unit.
3. Make sure that you install the unit away from heat
or vapor.
4. Make sure that you install the unit in an area
which is cool and has adequate space.
5. Make sure that you install the unit in an area away
from TVs, audio units, cordless phones,
fluorescent lighting fixtures and other electrical
appliances (at least 1 meter clearance).
6. Make sure that you install the unit in an area which
provides easy drainage for condensed water.
7. Make sure that you install the unit in area not
exposed to the rain or direct sunlight.
(Install a separate sunblind if exposed to direct
sunlight).
8. Make sure that you install the unit in an area
allowing good air movement. Do not install it in
a space that would cause noise amplification
of noise.
9. Fix the unit firmly if mounted in a high place.
Caution:
It is harmful to the air conditioner if it is used in the following environments : greasy areas (including areas near
machines), salty areas such as coast areas, areas where sulfuric gas is present (such as hot spring areas), Contact
your dealer for advice.
Samsung Electronics 3-1
3-2 Controls and Components
HI
COOL
HI
FAN
LOW
FAN
LOW
COOL
OFF
6
COOLEST
2
4
8
10
12
Timer indicator
3-2-1 Thermostat
1) Off :
When room temperature is lowered by using the air conditioner, the gas within the thermostat
will contract and cause a break in the electrical contact. The compressor will stop.
After the compressor stops, the room temperature will rise.
2) On :
As the room temperature increases to a selected level, the gas of the thermostat expands
causing electrical contact, which provides source of electric power to the compressor.
the room temperature will fall and the cycle will repeat.
3) Control Operation :
By turning control knob clockwise(toward higher numbers), the temperature will be cooler.
By turning the control knob counterclockwise(toward lower numbers), the temperature will be warmer.
Temperature indicator
Level 1 : Cool air will be supplied above 30~35¡C
Cool air will be ceased below 28~32.5¡C
Level 12 : Cool air will be supplied above 11~17¡C
Cool air will be ceased below 7~13¡C
3-2-2 Operating Switch
¥ Slowly turn the Fan Selector Switch in the following order : to LOW FAN, HIGH FAN, LOW COOL, HIGH COOL.
¥ OFF : All functions will be off.
¥ LOW FAN : The circulation of air is low.
¥ HIGH FAN : The circulation of air is maximum.
¥ LOW COOL : Circulation, cooling, and humidity removal are low(all simultaneousy operated).
¥ HIGH COOL : Circulation, cooling, and humidity removal are maximum(all simultaneously operated).
3-2 Samsung Electronics