Samsung AQ17HS-IS-NS, AQ19MS-IS-NS-FS Disassemble

3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the AQ17HS/AQ17IS/AQ17NS/AQ19MS/AQ19IS/AQ19NS/AQ19FS monitor.
WARNING: This monitor contains electrostatically sensitive devices. Use with caution when
handling these components.
3-1 Disassembly
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. To remove the Rear Cover, you must use the special opening jig tool.
3-1-1 Before making Disassembly
1. Disconnect or power cord from the monitor.
2. With a pad beneath it, stand the monitor on its front with the screen facing downward and the base close to you.
3-1-2 Cabinet Disassembly
1. Remove the Stand from the monitor. (Refer to Stand manual)
4. Push the Opening jig each groove along the Side of the monitor till it makes a “ttak” sound. (2 grooves : Left and Right, Make sure each snap is disengaged.)
Figure 1
3. Incline the monitor by lifting the rear of the monitor.
Figure 2
Figure 3
5. Pull the Rear Cover up off the monitor.
Figure 4
AQ17HS/AQ17IS/AQ17NS AQ19MS/AQ19IS/AQ19NS/AQ19FS
3-1
3 Disassembly and Reassembly
6. Remove the Shield.(TCO 99)
Figure 5
7. Using pinch-nose pliers or ling-nose pliers, acrefully disconnect the Anode Cap from the CRT.
Warning: Do not touch the Anode contact
on the CRT (High Voltage may remain).
3-1-3 Removing the CRT Socket PCB
1. Complete all previous steps.
2. Lift up the Video Spring and remove the CRT Socket PCB from the CRT.
3-1-4 Removing the Main PCB
1. Complete all previous steps.
2. Disconnect the Degaussing Coil at CN601 on the Main PCB.
3. Disconnect all easily accessible ground wires on the PCB and Bottom Chassis.
4. Disconnect the DY connector at the CN401 connector on the Main .
5. Using the jig, release the snaps (2) connecting the Front Cover and the PCB then lift up the Bottom to separate the two Shield.
Figure 7
Figure 6
3. Disconnect all connectors on the CRT Socket PCB.
4. Using a solder iron, disconnect 5points Ground (GND) on the back of the Video Shield and remove the Shield Cap.
5. Remove the screw on the front of the Shield Socket.
6. Place the Video PCB on a flat, level surface that is protected from static electricity.
6. Disconnect the Tilt connector at the CN409 connector on the Main PCB.
7. Disconnect the Sub PCB connector at the CN204 connector on the Main PCB.
8. Remove the screws on the back and along each side of the Bottom Chassis.
9. Carefully lift the Main PCB Assy and remove the remaining ground wires.
10. Place the Main PCB Assy on a flat, level surface that is protected from static electricity.
3-1-5 CRT Ass’y Disassembly
1. Complete all previous steps.
2. Straighten the Degaussing Coil Assembly coated metal ties and lift the Coil Assy from the CRT.
3. Remove the four corner screws and lift the CRT up and away from the Front Cover Assembly and place it on a padded surface.
Caution: Do not lift the CRT by the neck.
If you will be returning this CRT to the monitor, be sure to place the CRT face downward on a protective pad.
3-2 Reassembly
Reassembly procedures are in the reverse order of Disassembly procedures.
3-2 AQ17HS/AQ17IS/AQ17NS
AQ19MS/AQ19IS/AQ19NS/AQ19FS
Loading...