Salicru SPS 750 ADV R, SPS 1000 ADV R, SPS 1500 ADV R User manual

0 (0)

USER MANUAL

UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

SPS ADVANCE R & T

0,75.. 1,5 kVA & 0,85.. 3 kVA

2

SALICRU

General index.

1. INTRODUCTION.

1.1.THANK YOU LETTER.

2. SAFETY INFORMATION.

2.1.USING THIS MANUAL.

2.1.1.Conventions and symbols used.

3. QUALITY ASSURANCE AND STANDARDS.

3.1.STATEMENT BY THE MANAGEMENT.

3.2.STANDARDS.

3.3.ENVIRONMENT.

4. PRESENTATION.

4.1.VIEWS.

4.1.1.Views of the device.

4.1.1.1.Views of the SPS ADVANCE R device.

4.1.1.2.Views of the SPS ADVANCE T device.

4.2. DEFINITION OF THE PRODUCT.

4.2.1.Nomenclature.

4.3. OPERATING PRINCIPLE.

4.3.1.Operating diagram

4.3.2.Notable features.

4.4. OPTIONAL EXTRAS.

4.4.1.Isolation transformer:

4.4.2.Communication card.

4.4.2.1.Integration into computer networks using an SNMP adapter.

4.4.3.Extendable guide kits for mounting in a rack cabinet (only in SPS ADVANCE R models).

5. INSTALLATION.

5.1.RECEPTION OF THE DEVICE.

5.1.1.Reception, unpacking and contents.

5.1.2.Storage.

5.1.3.Transport to the site.

5.1.4.Siting, immobilising and considerations.

5.1.4.1.Rack-type mounting in a 19” cabinet (SPS ADVANCE R devices).

5.1.4.2.Preliminary considerations before connection.

5.1.4.3.Preliminary considerations before connection, regarding the batteries and their protections.

5.2. CONNECTIONS.

5.2.1.Connection of the input.

5.2.2.Connection of the IEC output connectors.

5.2.3.Output terminals (only in SPS ADVANCE T 3 KVA models).

5.2.4.Connection to the optional battery module (backup extension).

5.2.5.Terminals for EPO (emergency power off).

5.2.6.Communication port.

5.2.6.1.RS232 and USB port.

5.2.7.Smartslotfortheintegrationofanelectroniccommunication unit (SNMP).

5.2.8.Management and monitoring software.

5.2.9.Considerations before start-up with connected loads.

6. OPERATION.

6.1.STARTUP.

6.1.1.Checks before start-up.

6.2. UPS START-UP AND SHUTDOWN.

6.2.1.UPS start-up with mains voltage.

6.2.2.UPS start-up without mains voltage.

6.2.3.UPS shutdown with mains voltage.

6.2.4.UPS shutdown without mains voltage.

7. CONTROL PANEL WITH LCD DISPLAY.

7.1.COMPOSITION OF THE CONTROL PANEL WITH LCD DISPLAY.

7.2.GENERAL INFORMATION.

7.2.1.Information represented by the display.

7.3.AUDIBLE ALARMS.

7.4.WARNING AND ERROR OR FAULT CODES.

8. MAINTENANCE, WARRANTY AND SERVICE.

8.1.BATTERY MAINTENANCE.

8.1.1.Notes for the installation and replacement of the battery.

8.2.UPS TROUBLESHOOTING GUIDE.

8.3.WARRANTY CONDITIONS.

8.3.1.Terms of the warranty.

8.3.2.Exclusions.

8.4. TECHNICAL SERVICES NETWORK.

9. ANNEXES.

9.1.GENERAL TECHNICAL SPECIFICATIONS.

9.2.GLOSSARY.

USER MANUAL

SPS ADVANCE R & T UNINTERRUPTIBLE POWER SUPPLY (UPS)

3

1. INTRODUCTION.

1.1. THANK YOU LETTER.

We thank you in advance for the trust placed in us in the purchasing of this product. Read this instruction manual carefully in order to familiarize yourself with its content, since the more you know and understand the equipment the greater your satisfaction, level of safety and optimization of its functionalities will be. We remain at your disposal for any additional information or queries that you may wish to make.

Yours sincerely.

SALICRU

The equipment described herein is capable of causing significant physical damage in the event of improper handling. For this reason its installation, maintenance and/or repair must be carried out exclusively by our personnel or by qualified personnel.

Although no effort has been spared to ensure that the information in this user manual is complete and accurate, we are not responsible for any errors or omissions that may exist.

The images included in this document are for illustrative purposes and may not represent exactly the parts of the equipment shown, therefore they are not contractual. However, any divergence that may arise will be remedied or solved with the correct labelling on the unit.

Following our policy of constant evolution, we reserve the right to modify the characteristics, operations or actions described in this document without prior notice.

Reproduction, copying, assignment to third parties, modification or total or partial translation of this manual or document, in any form or by any means, without previous written authorization by our firm is prohibited, with the full and exclusive property rights over the same being reserved by our firm.

4

SALICRU

2. SAFETY INFORMATION.

2.1. USING THIS MANUAL.

The documentation of any standard equipment is available to the customer on our website for download (www.salicru.com).

For devices “powered by socket”, this is the website for obtaining the user manual and “Safety Instructions” EK266*08.

For devices with “permanent connection” via terminals, a CD-ROM or pen drive containing all necessary information for connection and start-up, including “Safety Instructions” EK266*08, may be supplied with it.

Before carrying out any action on the device relating to its installation or start-up, change of location, configuration or handling of any kind, carefully read the safety instructions.

The purpose of the user manual is to provide information regarding safety and explanations of the procedures for installation and operation of the equipment. Read them carefully and follow the steps indicated in the order established.

Compliance with the “Safety Instructions” is obligatory, with the user being legally responsible for observing and applying them.

The equipment is delivered properly labelled for the correct identification of each of the parts, which together with the instructions described in this user manual allows the operations of installation and commissioning to be performed in a simple and orderly manner without having any doubts whatsoever.

Finally, once the equipment is installed and operating, it is recommended to save the documentation downloaded from the website, CD-ROM or Pen Drive in a safe and easy-to-access place, for any future queries or doubts that may arise.

The following terms are used interchangeably in the document to refer to:

“SPS ADVANCE R, ADVANCE R, ADV R, R, R device, R unit or R UPS” - Uninterruptible power supply. Depending on the context of the phrase, it can refer either to the actual UPS itself or to the UPS and the batteries, regardless of whether it is all assembled in the same metal casing - box - or not.

“SPS ADVANCE T, ADVANCE T, ADV T, T, T device, T unit or T UPS” - Uninterruptible power supply. Depending on the context of the phrase, it can refer either to the actual UPS itself or to the UPS and the batteries, regardless of whether it is all assembled in the same metal casing - box - or not.

“Batteries or accumulators”.- Group or set of elements that stores the flow of electrons by electrochemical means.

“T.S.S.” - Technical Service and Support.

“Client, installer, operator or user” - These are used interchangeably and by extension to refer to the installer and/or operator who will carry out the corresponding actions, and the same person may be responsible for carrying out the respective actions when acting on behalf of, or in representation of, same.

2.1.1. Conventions and symbols used.

Some symbols may be used and appear on the equipment, batteries and/or in the context of the user manual.

For more information, see section 1.1.1 of document EK266*08 on "Safety instructions".

USER MANUAL

SPS ADVANCE R & T UNINTERRUPTIBLE POWER SUPPLY (UPS)

5

3. QUALITY ASSURANCE AND STANDARDS.

3.1. STATEMENT BY THE MANAGEMENT.

Our goal is customer satisfaction, therefore this Management has decided to establish a Quality and Environment Policy, through the implementation of a Quality and Environmental Management System that will enable us to comply with the requirements demanded in the ISO 9001 and ISO 14001 and also by our Customers and Stakeholders.

Likewise, the management of the company is committed to the development and improvement of the Quality and Environmental Management System, through:

Communication to the entire company of the importance of satisfying both the client's requirements as well as legal and regulatory requirements.

The dissemination of the Quality and Environment Policy and the setting of the Quality and Environment objectives.

Conducting reviews by the Management.

Providing the necessary resources.

3.2. STANDARDS.

The SPS ADVANCE R and SPS ADVANCE T are designed, manufactured and sold in accordance with Quality Management Standard EN ISO 9001. The marking indicates conformity with EC Directives through the application of the following standards:

2014/35/EU. - Low voltage safety.

2014/30/EU. - Electromagnetic Compatibility - EMC-.

2011/65/EU. - Restriction of the use of hazardous substances in electrical and electronic equipment (RoHS).

According to the specifications of the harmonized standards. Reference standards:

EN-IEC 62040-1. Uninterruptible Power Supplies -UPS-. Part 1-1: General and safety requirements for UPS used in user access areas.

EN-IEC 62040-2. Uninterruptible Power Supplies -UPS-. Part 2: EMC requirements.

The manufacturer is not liable in case of modification or intervention on the equipment by the user.

WARNING!:

SPS.ADVANCE R 0.75..1.5 kVA and SPS.ADVANCE T 0.85..3 kVA. These are category C2 UPSs. In residential environments, this product may cause radio interference, in which case the user must take additional measures.

These devices should not be used with basic life support (BLS) applications, where a power failure can render the life support equipment out of service or significantly affect its safety or effectiveness. It is also not recommended in medical applications, commercial transport, nuclear installations, or other applications or loads, where a failure of the product can lead to personal or material damages.

The EC declaration of conformity of the product is available to the customer upon express request to our headquarters.

3.3. ENVIRONMENT.

This product has been designed to respect the environment and manufactured according to ISO 14001.

Recycling of the equipment at the end of its useful life:

Our company undertakes to use the services of authorized and regulatory companies to treat the set of products recovered at the end of their useful life (contact your distributor).

Packaging:

For the recycling of the packaging there must be compliance with the legal requirements in force, according to the specific regulations of the country where the equipment is installed.

Batteries:

Batteries pose a serious danger to health and the environment. The disposal of them shall be carried out in accordance with the laws in force.

6

SALICRU

4. PRESENTATION.

4.1. VIEWS.

4.1.1. Views of the device.

Fig. 1 and Fig. 2 correspond to SPS ADVANCE R devices and Fig. 3 and Fig. 4 to SPS ADVANCE T devices. However, because the product is constantly evolving, discrepancies or slight contradictions may arise. If in any doubt, the labelling on the equipment itself will always prevail.

The nameplate of the device shows all of the values​ relating to its main properties and characteristics. Act accordingly for its installation.

4.1.1.1. Views of the SPS ADVANCE R device.

Control panel with

LCD display

Plastic front trim

Fig. 1. Front view of the SPS ADVANCE R.

IEC AC input

IEC AC output

RS232 COM

For connection to

connector

sockets

port

external EPO

AC input protection

Smart slot

fuse

protective cover

Fig. 2. Rear view of the SPS ADVANCE R.

USER MANUAL

SPS ADVANCE R & T UNINTERRUPTIBLE POWER SUPPLY (UPS)

7

Salicru SPS 750 ADV R, SPS 1000 ADV R, SPS 1500 ADV R User manual

4.1.1.2. Views of the SPS ADVANCE T device.

850 to 2000 VA models.

Batteries modules for 1000 to 2000 VA models.

Control panel

 

with LCD display

 

Plastic front

Plastic front

trim

trim

 

Front view of the device.

Front view of the batteries modules.

3000 VA models.

Battery module for 3000 VA model.

Control panel with LCD display

Plastic front

Plastic front trim

trim

 

Front view of the device. Front view of the battery module.

Fig. 3. Front view of SPS ADVANCE T devices according to power and battery modules.

8

SALICRU

850 to 2000 VA models.

Fan

RS232 COM

USB COM

port

port

 

For connection to

 

external EPO

 

Smart slot

 

protective cover

IEC AC output

AC power

sockets

 

protection breaker

 

IEC AC input

 

connector

Rear view of the standard device.

3000 VA model.

Fans

RS232 COM

USB COM

port

port

Smart slot

protective cover

For connection to

external EPO

IEC AC output

sockets

Output terminal

cover

AC power

protection breaker

IEC AC input

connector

Rear view of the standard device.

Fig. 4. Rear views of devices according to power.

1000 to 2000 VA B1 models.

Fan

RS232 COM

USB COM

port

port

 

 

For connection to

 

 

external EPO

 

 

IEC AC output

 

 

sockets

Battery

 

AC power

 

protection breaker

connector

 

 

IEC AC input

 

 

 

 

connector

 

 

Smart slot

 

 

protective cover

Rear view of the B1 device.

3000 VA B1 model.

Fans

RS232 COM

USB COM

port

port

Smart slot

protective cover

For connection to

external EPO

IEC AC output

sockets

Output terminal

cover

AC power

protection breaker

Battery

connector

IEC AC input

connector

Rear view of the B1 device.

USER MANUAL

SPS ADVANCE R & T UNINTERRUPTIBLE POWER SUPPLY (UPS)

9

Loading...
+ 19 hidden pages