FIFTH
DISPLAY BOX
LAPTOP
25´ CABLE TO
FIFTH WHEEL -
could be
2-piece cable
(cab end)
DATA DOWNLOAD
CABLE
(shown in gray)
DISPLAY BOX
CONNECTOR
DATA DOWNLOAD
KIT OPERATING
INSTRUCTIONS
WHEELS
Electronic Lock Indicator
RK-10076
12- and 24-volt system
DOWNLOAD SOFTWARE
In order to use the ELI data download software, you must first download the application
program. To obtain the data download software program, contact Holland Hitch
Company at 1-888-396-6501 and request a 3
(1) Data Download Cable
(1)
SET UP
1
/2˝ floppy disk.
Kit Contents for RK-10076 Download Kit
Tools and Supplies Required to Complete a
Successful Download
Laptop Computer
With Windows 95 or later, and a minimum of 2MB RAM.
1. Disconnect the ELI display box connector from
cab end of the 25´ cable (could be a 2-piece
cable).
Connect the data download cable to the display
2.
box connector, the 25´ cable, and the laptop
computer as shown in FIGURE 1.
urn the power on for both the ELI unit and the
T
3.
laptop computer
.
FIGURE 1
XL-FW403-01 Rev A
U.S. Patent #5861802, D442971, 6285278, and other patents pending.
1
RUN DATA DOWNLOAD SOFTWARE
. Double click the executable file (Hitch Report
1
4.2.exe) that was downloaded from the floppy
disk.
2. Select the “Read” button. See FIGURE 2.
FIGURE 2
3. Check the ELI display box to make sure an error
code “1” or “3” is showing. If neither appears,
turn the power to the ELI unit off, then on until
code “1” or “3” is displayed. See FIGURE 3.
FIGURE 3
FLASHING RED
DISPLAY AND COUPLING HISTORY
When the download is complete, a display similar
to the one shown in FIGURE 6 will appear on your
computer screen. The numbers below correspond to
the numbers shown in FIGURE 6.
1
Memory Check.
The memory is automatically checked for
corruption, and the results will appear as “OK”
or “FAILS”.
If “OK” is displayed, the coupling history
appears.
If “FAILS” is displayed, the coupling history may
be inaccurate. Turn the power to the ELI off and
then on. Repeat Steps 2 through 5 in the “Run
Data Download Software” section.
If the memory check continues to fail, the ELI
display box should be replaced.
2
Serial Number.
The serial number displayed in the coupling
history will match the serial tag affixed to the
outside surface of the ELI display box.
4. Once the box is ready, click “Yes.” See FIGURE 4.
FIGURE 4
5. As the software is downloading the data, the
ELI display will simultaneously show a GREEN,
locked padlock icon and a RED, unlocked
padlock icon. See FIGURE 5.
3
Total number (up to 16 million) of coupling
attempts detected by the ELI.
A coupling attempt is counted when the
ELI detects a change from “Ready to Couple”
status to “Proper Couple” status, or when an
error code number occurs.
4
The remainder of the Coupling History report
displays a detailed summary for the indicated
number of the most recent coupling events.
The ELI memory capacity limits the storage
to approximately 250 of the most recent
coupling events.
5
Number of proper couples.
A proper couple is attained when the ELI detects,
first, the kingpin in the lock at the
proper height; and second, the lock mechanism
fully closed in the locked position.
6
Number of total attempts.
FIGURE 5
GREEN RED
2
7
cent pr
Per
The per
oper couples.
centage of total couples that wer
e proper
is calculated using the following formula: Proper
couples (5) ÷ total attempts (6) x 100.
5
6